Вы находитесь на странице: 1из 4

flange thk.

250
Griplength 500.11811
B7
Sallowable
ce
C
F
Et
Ce
strain
S exp
remain

500.1181102 500.11811 500.11811


25
25
25
300
400
500
28.5
27.9
27.5
1.9
2.8
3.7
0.001583333 0.0023333 0.0030833
45125.0
65100.0
84791.7
4875
-15100 -34791.667

-0.0009

500.1181 500.1181 500.1181 500.1181 500.1181


25
25
21
20.5
4.5
600
700
800
900
1000
26.9
26.3
25.5
24.8
23.9
4.7
5.7
6.8
1.1
9
0.003917 0.00475 0.005667 0.000917
0.0075
105358.3 124925.0 144500.0 22733.3 179250.0
-55358.33
-74925
-94500 27266.7 -129250
27.26667

10" SS Flange leak investigation

Data
Temp.-Press. Rating at 530C =2958 psi
Allowable Stress of bolt@ 530C = 11000 psi
Design pressure = 1995 psi,Operating 1799 psi
Linear thermal exp. Of bolt @ 530C = 0.0075in/in
Linear thermal exp. Of flange @ 530C = 0.64in/in
Grip length = 19.68 in.
Ef = 25.4x1000000 psi
Assumption
Min.bolt stress @ Design temp. = (1995/2958)*11000 =
Min.bolt stress @ Operat. temp. =(1799/2958)*11000 =

7418.864 psi
6689.993 psi

Investigation
Stress reduce due to different thermal expansion between bolt and flange
= 25.4x1000000x(0.0075-0.0064) =
27940 psi
Minimum preload of bolt require for design temp. = 7418.87+27940 =
Minimum preload of bolt require for operat. temp. = 6689.99+27940 =
If Torque to 55000 psi at design temp. will remain =
If Torque to 55000 psi at operat. temp. will remain =

27060 psi
27060 psi

35358.87
34629.99

0.006417

psi
psi

0.642889
0.629636