Вы находитесь на странице: 1из 27

AUTOMATIC TANK GAUGING

SUPPLIED BY : M/S SAAB, SWEDEN.

INDIAN REPRESENTATIVE : M/S JOST ENG. PUNE.

CUSTOMER : RELIANCE PETROLEUM LTD. CONSULTANT : BECHTEL LTD.


PRESENTATION PREPARED BY : SETAL KALAVADIA

ATG COVERS

REFINERY TANK FARM RAW-MATERIAL TANKS - 07 INTERMEDIATE STORAGE TANKS - 25 BLEND-COMPONANT TANKS - 09 FINISHED PRODUCT TANKS - 55 MARINE TANK FARM RAW MATERIAL TANKS - 16 FINISHED PRODUCT TANKS - 27 ROAD / RAIL TANK FARM RAW MATERIAL TANKS - 04 FINISHED PRODUCT TANKS - 18 UNIT DAY TANKS AROMATIC TANKS - 04 SULPHUR TANKS - 04 UTILITY / CPP TANKS - 08

WHY SAAB WAS SELECTED


NO MOVING PART PROVEN RADAR TECHNIQUE-CAN BE USED FOR

WHITE & BLACK OILS WITH DIFFERENT GAUGE HEAD. MEETING CUSTODY TRANSFER REQUIREMENTS PROVEN FOR INTERFACING WITH FOXBORO.

SAAB SYSTEM COMPONENTS


RADAR LEVEL GAUGE MULTI SPOT TEMPERATURE PROBE SINGLE SPOT TEMPERATURE PROBE BOTTOM WATER LEVEL PROBE VAPOUR/N2 PRESSURE TRANSMITTER HYDROSTATIC PRESSURE TRANSMITTER DATA ACQUISITION UNIT INDIPENDENT DISPLAY UNIT FIELD COMMUNICATION UNIT FIELD BUS MODEM OPI STATION

RTG MODELS FOR RELIANCE

RTG2920

FOR FIXED ROOF INSTALLATION WITHOUT STILL PIPE

RTG2930
FOR FIXED ROOF INSTALLATION WITHOUT STILL PIPE FOR STICKY AND CONDENSING PRODUCT.

RTG2940

FOR MEASUREMENT IN STILL PIPE

RTG2960

FOR LIQUID GAS, LPG

RTG ELECTRONIC UNIT


WORKING ON FREQUENCY MODULATED CONTINUOUS WAVE (FMCW) FREQUENCY: 9.7 TO 10.3 GHz RESIDE INSIDE TRANSMITTER HEAD SAME ELECTRONICS HEAD IRRESPECTIVE OF ANTENNA TYPE CARDS INSIDE
POWER SUPPLY CARD COMMUNICATION CARD SIGNAL PROCESSING CARD CURRENT LOOP CARD BARRIER UNIT

MULTI SPOT TEMPERATURE PROBE


PT 100 RTD SPOT ELEMENT NUMBER OF SPOT BASED ON TANK HEIGHT

DATA ACQUISITION UNIT 2100


USED TO CONNECT TEMP. SENSORS & COMB. TEMP. & WATER BOTTOM CONNECTED TO RTG VIA BARRIER LCD DISPLAY FOR LOCAL READ OUT

FIELD COMMUNICATION UNIT 2160


DATA CONECENTRATOR FOR RTG DATA DUAL REDUNDANT SIX COMMUNICATION PORT POWER REQUIRE: 110 V AC.

FIELD BUS MODEM 2170


CONVERTER BETWEEN RS-232 & THE TRL/2 BUS. USED FOR CONNECTING PC WITH OPI (COS) TO THE TRL/2. POWER REQUIRED:6-15 V , 10 MA.

SYSTEM INTERFACING

ACCURACY
LEVEL :- +/- 1 mm BOTTOM WATER LEVEL :- +/- 3 % OF FULL

RANGE. TEMPERATURE :- +/- 0.1 deg C HYDROSTATIC PRESSURE:- +/- 0.1 % OF FULL SCALE STATIC PRESSURE:- +/- 0.1 % OF FULL SCALE

PIB HEAVING ATG


PIB-19 PIB-20 PIB-29 PIB-28 PIB-21 PIB-18 PIB-11 PIB-5 MRS OPI FCU TANKS 01 10 55 01 06 41 01 04 23 00 04 19 01 04 22 00 02 09 00 02 05 00 02 08 00 02 04

TYPES OF TANKS AT JAMNAGAR


INTERNAL FLOATING ROOF WITH N2 BLANKET - FOR CUSTODY TRANSFER - 1C INTERNAL FLOATING ROOF WITH N2 BLANKET - NOT FOR CUSTODY TRANSFER - 1N CONE ROOF WITH N2 BLANKET - FOR CUSTODY TRANSFER - 2C CONE ROOF WITH N2 BLANKET - NOT FOR CUSTODY TRANSFER - 2N CONE ROOF-FOR CUSTODY TRANSFER - 3C CONE ROOF-FOR CUSTODY TRANSFER - 3N OPEN FLOATING ROOF -FOR CUSTODY TRANSFER-4C OPEN FLOATING ROOF -FOR CUSTODY TRANSFER-4N SPHERE - SC

INTERNAL FLOATING ROOF WITH N2 BLANKET - FOR CUSTODY TRANSFER - 1C

INTERNAL FLOATING ROOF WITH N2 BLANKET - NOT FOR CUSTODY TRANSFER - 1N

CONE ROOF WITH N2 BLANKET - FOR CUSTODY TRANSFER - 2C

CONE ROOF WITH N2 BLANKET - NOT FOR CUSTODY TRANSFER - 2N

CONE ROOF-FOR CUSTODY TRANSFER - 3C

CONE ROOF-FOR CUSTODY TRANSFER - 3N

OPEN FLOATING ROOF -FOR CUSTODY TRANSFER-4C

OPEN FLOATING ROOF -FOR CUSTODY TRANSFER-4N

SPHERE - SC