Minimum Temperature Approach = 10C Hot Stream Data Mass Flow Cp Temp In kg/s kJ/kg/C C 40.00 10.00 12.00 .8000 .8000 1.000 300.0 150.0 200.0 Temp Out C 150.0 50.00 50.00 Stream Enthalpy kW 4800. 800.0 1800. 7400.0 kW Film Heat Transf. Coef W/m2/C 400.0 270.0 530.0

Cumulative Hot Stream Energy Available = Cold Stream Data Mass Flow Cp Temp In kg/s kJ/kg/C C 25.00 40.00 16.00 .8000 .8000 1.000 190.0 90.00 40.00 Temp Out C 290.0 190.0 190.0

Stream Enthalpy kW -2000. -3200. -2400. kW

Film Heat Transf. Coef W/m2/C 100.0 250.0 80.00

Cumulative Cold Stream Energy Available = -7600.0

Data for Generating Temperature Interval Diagram Number of Temperature Intervals = 4 Interval Temperature C 300.0 200.0 150.0 100.0 Range C 200.0 150.0 100.0 50.00 Excess Heat kW 1200. -200.0 -1400. 200.0 Cummulative Q kW 1200. 1000. -400.0 -200.0

A B C D

Pinch Temperature - Hot = 100C Pinch Temperature - Cold = 90C

Hot Utility Requirement = 400 kW Cold Utility Requirement = 200 kW Minimum Number of Exchanger Required to Accomplish Minimum Utility Loads In Special Circumstances the Minimum Required may be Lower than Indicated Below Number Above the Pinch =6 Number Below the Pinch =3 Data for Composite Enthalpy - Temperature Diagram Temperature C 50.00 100.0 150.0 200.0 300.0 Hot Stream Enthalpy kW .0000 1000. 2000. 4200. 7400. Temperature C 40.00 90.00 140.0 190.0 290.0 Cold Stream Enthalpy kW 200.0 1000. 3400. 5800. 7800.

Heat Transfer Area for Process Exchangers in Network = 3154 m2

SYNENSIS CORP

II. Temperature Interval Diagram

III. Cascade Diagram

SYNENSIS CORP

IV. Cumulative Enthalpy

V. Input Range and Data for Plots

SYNENSIS CORP

VI. Relation for Heat Transfer Area & Utilities

VII. Equivalent Annual Operating Cost (EAOC)

SYNENSIS CORP

VIII. Design of Exchanger Network Above the Pinch

Exchanger Report for Above Pinch Minimum Allowable Approach Temperature = 10C Exchanger Number = 1 Exchanger Duty = 400 kW Exchanger Area = 160 m2 Number of Shells = 2 Exchanger Cost = $ 51394 Overall Heat Transfer Coefficient = 129.8 W/m2/C Log Mean Temperature Difference = 24.1C Hot Stream Number = 2 Temperature In = 150C Temperature out = 100C Cold Stream Number = 5 Temperature In = 90C Temperature out = 102.5C Minimum Temperature Approach = 10C Minimum DT Violation = No Exchanger Number = 2 Exchanger Duty = 1200 kW Exchanger Area = 1081.3 m2 Number of Shells = 5 Exchanger Cost = $ 273871 Overall Heat Transfer Coefficient = 69.5 W/m2/C Log Mean Temperature Difference = 20C Hot Stream Number = 3 Temperature In = 200C Temperature out = 100C Cold Stream Number = 6 Temperature In = 90C Temperature out = 165C Minimum Temperature Approach = 10C Minimum DT Violation = No Exchanger Number = 3 This is a Hot Utility Exchanger Exchanger Duty = 400 kW Exchanger Area = 337.5 m2 Exchanger Cost = $ 74981 Overall Heat Transfer Coefficient = 74.1 W/m2/C Log Mean Temperature Difference = 20C Cold Stream Number = 6 Temperature In = 165C Temperature out = 190C

SYNENSIS CORP

Exchanger Number = 4 Exchanger Duty = 2800 kW Exchanger Area = 478.9 m2 Number of Shells = 2 Exchanger Cost = $ 118942 Overall Heat Transfer Coefficient = 153.8 W/m2/C Log Mean Temperature Difference = 47.5C Hot Stream Number = 1 Temperature In = 237.5C Temperature out = 150C Cold Stream Number = 5 Temperature In = 102.5C Temperature out = 190C Minimum Temperature Approach = 47.5C Minimum DT Violation = No Exchanger Number = 5 Exchanger Duty = 2000 kW Exchanger Area = 1298.4 m2 Number of Shells = 4 Exchanger Cost = $ 270712 Overall Heat Transfer Coefficient = 80 W/m2/C Log Mean Temperature Difference = 24.1C Hot Stream Number = 1 Temperature In = 300C Temperature out = 237.5C Cold Stream Number = 4 Temperature In = 190C Temperature out = 290C Minimum Temperature Approach = 10C Minimum DT Violation = No

IX. Design of Exchanger Network Below the Pinch

SYNENSIS CORP
Exchanger Report for Below Pinch Minimum Allowable Approach Temperature = 10C Exchanger Number = 1 Exchanger Duty = 400 kW Exchanger Area = 810.1 m2 Number of Shells = 5 Exchanger Cost = $ 246206 Overall Heat Transfer Coefficient = 61.7 W/m2/C Log Mean Temperature Difference = 10C Hot Stream Number = 2 Temperature In = 100C Temperature out = 50C Cold Stream Number = 6A Temperature In = 40C Temperature out = 90C Minimum Temperature Approach = 10C Minimum DT Violation = No Exchanger Number = 2 Exchanger Duty = 400 kW Exchanger Area = 423.3 m2 Number of Shells = 3 Exchanger Cost = $ 124487 Overall Heat Transfer Coefficient = 69.5 W/m2/C Log Mean Temperature Difference = 17C Hot Stream Number = 3 Temperature In = 100C Temperature out = 66.7C Cold Stream Number = 6B Temperature In = 40C Temperature out = 90C Minimum Temperature Approach = 10C Minimum DT Violation = No Exchanger Number = 3 This is a Hot Utility Exchanger Exchanger Duty = 200 kW Exchanger Area = 39.2 m2 Exchanger Cost = $ 21836 Overall Heat Transfer Coefficient = 318.8 W/m2/C Log Mean Temperature Difference = 20C Hot Stream Number = 3 Temperature In = 66.7C Temperature out = 50C