Вы находитесь на странице: 1из 15

Stack dia (throat) Bosh dia Hearth dia Stack Height Bosh Height Hearth Height

7300mm 10900mm 9750mm 2300mm 3000mm 3800mm

Total overall Full Height Useful Height Total useful Volume No. of Tuyers No. of tapping hole No. of hot Stove

30350mm 29700mm 2000mm3 24 2 4

Fe2O3 to Fe3O4 ~ 25 % expansion Fe3O4 to FeO ~ 5 % expansion FeO to Fe ~ 7 % contraction

Gas & Burden expands in front of tuyere

Hot Metal Analysis C Si Mn S P 4.5% 0.5% 0.6% 0.02% 0.06%

Slag Analysis

BF Gas Analysis

SiO2
Al2O3 CaO MgO

38%
9% 42% 10%

CO
CO2 H2 N2

23%
21% 2.5% 53.5%

1.3%

RECEIVING HOPPER

Charging Equipment mainly includes: Fixed receiving hopper, upper & lower sealing valve, hoppers, discharging material box, gear box and distributing chute.

Charging valve Upper sealing Valve


HOPPER

Regulating Valve Lower Sealing Valve

Gear box Rotating Chute

10

12

Hot metal Iron Carbon Silicon Fe C Si

Typical 94.5% 4.5% 0.40%

Slag CaO MgO SiO2 Al2O3

Typical 40% 10% 36% 10%

Range 34-42% 6-12% 28-38% 8-20%

Manganese Sulphur Phosphorous

Mn S P

0.30% 0.03% 0.07% Sum Sulphur 96% 1%

Вам также может понравиться