4. Having selected the necessary components for the installation, press the Next button to begin the installation. A progress bar will show the progress of the installation process.
OVERVIEW
This quick guide takes you through the steps to get your Cinegy Air Express software up and running. Cinegy Air Express Control product is used for scheduled playout, commonly described as broadcast automation with video server playout. There are two components to install: Cinegy Air Express Control client and Cinegy Air Express Engine. The client component can be configured via the Cinegy Air Express Configurator, while the Cinegy Air Express Engine is configured separately with its own configurator. There are six stages: STEP ONE: Preparing for Installation STEP TWO: Cinegy Air Express Control Client Installation STEP THREE: Configuring Cinegy Air Express Control STEP FOUR: Cinegy Air Express Engine Installation STEP FIVE: Configuring Cinegy Air Express Engine STEP SIX: Launching the Cinegy Air Express Playout Engine Cinegy Air Express Features
Passive Mode Configuration In the Cinegy Air Express Control tab, choose Passive mode (playlist edit) to prepare your playlist offline before sending material on-Air Express in active mode. No playout stations are connected when using passive mode.
In the User log folder specify the folder location where the user log files will be stored. To do this, use the appropriate button or enter the path via the keyboard.
Page 1
www.cinegy.com
cinegy
STEP FOUR: Cinegy Air Express Engine Installation
The Cinegy Air Express Engine executes the playlist and renders video to Air Express. 1. To begin installation, run the Setup.exe file from the Cinegy Air Express Engine directory of your Cinegy Air Express installation package. The setup wizard will be started 2. Press Next, read and accept the license agreement to proceed. 3. Define the folder where the Cinegy Air Express Engine will be installed.
Select the Split audio option to split all audio channels according to the settings on the playout station; otherwise all audio channels will be mixed into a single stereo audio channel before broadcasting. Define the default target aspect ratio. Select the Enable collaboration option if you want to activate the multiuser synchronous collaboration support for your client using the individual playlist configurations. Active Mode Configuration
Single Channel Mode
After the playlist has been prepared offline, it can be sent on-air. Active mode enables you to broadcast a playlist to a specified channel. To activate this mode, set the Cinegy Air Express Control client to Single channel mode:
4. Press the Next button and begin the installation. A progress bar will show the progress of the installation process. 5. During installation the Cinegy Air Express Engine configurator will be launched. You can leave the default settings without changes and configure your Cinegy Air Express Engine later, or you can specify all the necessary parameters during installation. Details for configuring the Cinegy Air Express Engine can be found in Step Five. 6. Press the Finish button to exit the setup wizard. 7. The Cinegy Air Express Engine icon will appear in the notification area of the taskbar. Tick the Swap control monitors checkbox to swap the position of the control monitors on the playout control panel. Tick the Autoconnect on start checkbox to connect automatically to the playout server on startup. Define the startup protection parameters and assign the users with the privileges to log in to the application by pressing the Security button. In the User log folder specify the folder location where the user log files will be stored. To do this, use the appropriate button or enter the path via the keyboard. Set up the video system, aspect ratio and VU meter parameters. Define the active playlist file location and the playout server(s). If several Cinegy Air Express Engine instances are started on the same server, you need to specify what Engine instance will be used to process the specified playlist in the corresponding # field next to the server IP adress. When both Cinegy Air Express Control client and Cinegy Air Express Engine are installed on the same computer, the . should be specified as the server name. In the Cinegy Type Repository field, specify the folder location where the CG templates are stored. Select the Split audio option to split all audio channels according to the settings on the playout station. Set up the target aspect ratio parameters. If collaboration mode is required, select the Enable collaboration option. Multi-Instance Playout Service Several Cinegy Air Express Engines can be started on the same machine. With the help of Cinegy Air Express Engine configurator you can add/remove Cinegy Air Express Engine instances and configure each of them individually. Cinegy Air Express Engine Configuration dialog is launched during the Cinegy Air Express Engine installation or can be launched from
Start > All Programs > Cinegy > Cinegy Air Express Engine > Cinegy Air Express Engine Configuration.
To configure the specified Engine instance, select it and press the Configure... button. The Configure Instance dialog will appear. Details for configuring the
Page 2
www.cinegy.com
cinegy
This procedure works for Windows XP, Windows 7, Windows Server 2008 and Windows Server 2008 R2.
Cinegy Air Express Engine instances can be found in Step Five. By default, only one instance is created. To add more instances, select any Free instance and configure it by pressing the Configure... button and specifying all the necessary parameters. To remove the specified instance, select it and press the Remove button. A separate license should be acquired for each Cinegy Air Express Engine instance. Automatic Log On To enable the Cinegy Air Express Engine to launch automatically after restarting the PC, you will need to set up the automatic logon for your operational system. If you are a domain user, the checkbox Users must enter a user name and password to use this computer is hidden in the User Accounts dialog. To show this option and be able to configure it, open a command prompt and enter the following line: reg add HKLM\SOFTWARE\Microsoft\Windows NT\ CurrentVersion\Winlogon /v AutoAdminLogon /t REG_SZ /d 1 /f Now you can turn on automatic logon for Windows OS, using the following steps: 1. Go to Start and click Run (or use the Win + R shortcut). 2. In the Run dialog box that opens, enter control userpasswords2 in the given field and press OK. 3. In the User Accounts dialog that appears, deselect the checkbox Users must enter a user name and password to use this computer and press the Apply button.
Select the desired Engine instance and press the Configure... button. In the General tab, specify the license type and whether the Cinegy Type scenes should be sent to playout. Specify the media files that will go on-Air Express if network errors occur and define the remote server for executing external commands.
In the Playback tab, define the basic TV video format system that you want to use for broadcasting; set one or several channels.
4. In the Automatically Log On dialog, enter the user name and password that will be used for automatic logon, press OK to apply your changes.
5. Press OK to apply your automatic log on settings and exit the User Accounts dialog. After restarting your computer, you will be logged on automatically under the account you specified. If your computer is in the domain, you also need to configure the default domain. Enter the following line in the command prompt, specifying your domain name: reg add HKLM\SOFTWARE\Microsoft\ Windows NT\ CurrentVersion\Winlogon /v DefaultDomainName /t REG_SZ /d domain /f Page 3
www.cinegy.com
cinegy
Manual Launch This mode is mainly used for troubleshooting. Cinegy Air Express Engine can be started manually by running the PlayOutExApp.exe file. With this method you will have to restart it manually each time the Cinegy Air Express Engine application is closed. When the Cinegy Air Express Engine is started manually, the following window appears:
In the Logging tab define the settings of the log files creation: logging level, location for the log files, how often the new log files should be created.
Head 0 and Head 1 progress bars represent buffer filling; they vary while playlist items are played back. Head 0 displays buffer filling for the item currently playing and Head 1 shows the next cued item. To close this application, press the Close button. If any problems occur while working with the Cinegy Air Express Engine application, you can create a dump file by pressing the Debug! button and send it to Cinegy support via e-mail. The memory dump file contains register states, descriptions of where the problems originated, plus workflow and other debug data. A dump file is created automatically in the unlikely event of a Cinegy Air Express Engine failure.
The following options are not supported in the Express version of Cinegy Air: MPEG Logging output device, Item proxying and Live switch events
The following Cinegy Air Express Engine Dashboard window will appear:
Here you can see the control monitors of all Cinegy Air Express Engine instances. Each Engine instance can be started/stopped individually. To exit the application, use the Exit command. To launch the Engine again, run the AirPlayer.exe file from your Cinegy Air Express Engine installation folder.