Академический Документы
Профессиональный Документы
Культура Документы
Model:
SL200SPrimary SL200Standard SL200MMortise SL200TTtype SL220SPrimary SL220Standard SL220TTtype SL200DSPrimary SL200DStandard SL200DTTtype SL220DSPrimary SL220DStandard SL200DTTtype
250X42X25(mm)
190X38X26(mm)
267X66X40(mm)
500X42X25(mm)
534X66X40(mm)
ElectromagneticLockSpecification:
SL200Series SL220Series Notation DC12V/DC24V DC12V/DC24V Powersupply 400mA/12VDC 500mA/12VDC Operationcurrent 200mA/24VDC 250mA/24VDC NO&NC(OnlyforStandardandTtypemodel) HallEffectSensor Doorsensor Operationdelaytime 0Sec./3Sec./5Sec./9Sec.(OnlyforTtypemodel) OutswingdoorandInswingdoor Application Holdingforces 600lbs(250Kg) 1200lbs(500Kg) Operationtemperature 355(Iinsideairtemperature30) Thewarrantyis2yearsfornormalusing Warranty 2kg 5kg Weight
Electromagneticlockaccessoriesdiagram:
Accessories:
Modeltype
Type
SL200 SL220
Quantity
Notations
Body
A r m a tu r e ( M i n i)
6. 4 m m x 12 .5 m m (1 /4 " x 1 / 2 " )
8 .0 m m ( 5 / 1 6 " )
6 . 4 m m x 1 2 . 5 m m (1 / 4 " x 1 / 2 " )
Magnet(Mini)
3.2 mm(1/8") 8mm(5/16") 3.2 mm(1/8" )
Alignment sticker
SexnutBolt Doorspacer Screw4X25mm Screw4X15mm Screw5X32mm Screw5X25mm Rubberwasher Washer Allen keys3mm Hexgon keys 5mm Guidepins
1 1 6 3 X X 2 3 1 1 2
1 1 X 1 4 2 2 3 X 1 2
Page1
Installationinstructions:
Wheninstallingmagneticlockusershouldbesureofthetypeofdoorused.Magnetic lockisspecificallyfortheuseofoutswingdoor.Abracketisusedtoinstallwith magneticdoorforinswingdoor.
Armature Armature Screw ZBracket LBracket Indoor L Bracket Door Frame
Outdoor Doorleaf
[Outswingdoor]
[Inswingdoor]
[L.Z.Bracket]
[Installation ]
(Smoothsurfacefacesup)
[1]
Drillan8mm(516) holethroughdoor
[2]
mustbeloose slightly
Page2
Step4: Selectthecorrectvoltageanddelaytime
VoltageSelectionJumper Body
+V PowerInput V
Armature
PrimaryStandard
TimeDelaySwitch
V+ V S2
Ex it Bu tton
BladeStop
Door
Frame
Power Supply
0 .0sec
2.5 sec
0.0SEC
2.5SEC
ON
1 2
5 .0sec
9.0 sec
MountingPlate
5.0SEC 1 2 ON 9.0SEC
Voltag eSelec t
12V
24V
Body
Ttype
AutolockDelay TimeSettings
[Installationdiagram]
Outdoor
Indoor
(Settingofvoltage,pleaserefertooutswingdoorStep4)
Page3
Armature
L Bracket
Outdoor
LBracket Indoor
Doorleaf
[Installationdiagramforbracketandmagneticlock]
Attentions:
(1)Regardlessthetypeofdoorused,thelockmustbeinstalledormountedindoors. (2)Thearmaturemustbelooseslightlytocompensatethedoor misalignment. (3)Doorspacerisusedtopreventanydamagetothehollowdoorwhenitistightened. (4)EB/SBseriesofarmaturebracketsareusedwheninstallingoutswing.
wooden door wooden door glass door
TobeusedwithEBorSB bracket
[EB200/220] Armatureplatehousing
[SB200/220] Armatureplatebracket
[UB200/220] Glassholder
Question&answer
Doorisnotlightlylocked? 1.Checkifthevoltageiscorrect2.Checkifthesettingofvoltageiscorrect3.Checkifthemagneticlockandarmatureareengagedlightly. Indicatorlightisunabletoshowgreenlightwhendoorclosed? 1.Checkifthearmatureismountedtothecorrectposition. 2.Checkifthevoltageissetcorrectly.Anydustorrustwillaffecttheoperationofthelock. Maintenanceofthemagneticlock? 1.Anydustorrustshouldberemovedregularly. 2.Lubricantshouldbeapplyonthemagneticlocktoavoidanyrustdependingontheenvironmentitisinstalled(suchasseaside).
02.8.V10.E
Page4