Вы находитесь на странице: 1из 3

Cluster configuration

Device: Juniper SRX5600 Operative system: JunOS 12.1R3.5

Abstract:
This is a step-by-step procedure to come up a SRX 5600 cluster. Hardware Description
node0: -------------------------------------------------------------------------Hardware inventory: Item Version Part number Serial number Description Chassis XXXXXXXXXXXX SRX 5600 Midplane REV 01 710-024804 XXXXXXXX SRX 5600 Midplane FPM Board REV 01 710-024631 XXXXXX Front Panel Display PEM 0 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in PEM 1 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in PEM 2 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in PEM 3 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in Routing Engine 0 REV 06 740-023530 XXXXXXXXXXX SRX5k RE-13-20 CB 0 REV 05 710-024802 XXXXXX SRX5k SCB FPC 4 REV 17 750-027945 XXXXXXXX SRX5k FIOC CPU REV 04 710-024633 XXXXXXXX SRX5k DPC PMB PIC 0 REV 09 750-027491 XXXXXX 16x 1GE TX PIC 1 REV 07 750-021378 XXXXXX 4x 10GE XFP Xcvr 0 NON-JNPR XXXXXXXXX XFP-10G-SR Xcvr 1 NON-JNPR XXXXXXXXX XFP-10G-SR Xcvr 2 NON-JNPR XXXXXXXXX XFP-10G-SR Xcvr 3 NON-JNPR XXXXXXXXX XFP-10G-SR FPC 5 REV 18 750-023996 XXXXXXXX SRX5k SPC CPU REV 04 710-024633 XXXXXXXX SRX5k DPC PMB PIC 0 BUILTIN BUILTIN SPU Cp-Flow PIC 1 BUILTIN BUILTIN SPU Flow Fan Tray Left Fan Tray node1: -------------------------------------------------------------------------Hardware inventory: Item Version Part number Serial number Description Chassis XXXXXXXXXXXX SRX 5600 Midplane REV 01 710-024804 XXXXXXXX SRX 5600 Midplane FPM Board REV 01 710-024631 XXXXXX Front Panel Display PEM 0 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in PEM 1 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in PEM 2 Rev 03 740-023485 XXXXXXXXXXX PS 1.2-1.7kW; 100-240V AC in

PEM 3 Rev 03 AC in Routing Engine 0 REV 06 CB 0 REV 05 FPC 4 REV 09 CPU REV 03 PIC 0 REV 07 PIC 1 REV 11 Xcvr 0 Xcvr 1 Xcvr 2 Xcvr 3 FPC 5 REV 18 CPU REV 04 PIC 0 PIC 1 Fan Tray

740-023485 740-023530 710-024802 750-027945 710-024633 750-027491 750-021378 NON-JNPR NON-JNPR NON-JNPR NON-JNPR 750-023996 710-024633 BUILTIN BUILTIN

XXXXXXXXXXX XXXXXXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX XXXXXXX BUILTIN BUILTIN

PS 1.2-1.7kW; 100-240V SRX5k RE-13-20 SRX5k SCB SRX5k FIOC SRX5k DPC PMB 16x 1GE TX 4x 10GE XFP XFP-10G-SR XFP-10G-SR XFP-10G-SR XFP-10G-SR SRX5k SPC SRX5k DPC PMB SPU Cp-Flow SPU Flow Left Fan Tray

Procedure
# # # # # Cluster in SRX5600 requires four steps: - License the node - Cluster activation in both nodes - Definition of fabric links ( - interface rethx configuration

# Execute this process in master node and later in secondary node. # You must guarantee that NTP is all the time available to come up with the cluster # licensing already done. # in operational mode user@host> set chassis cluster cluster-id 1 node 0 reboot # after reboot in configuration mode # configure management interfaces from the console port # node 0 - primary set groups node0 system host-name node0-router set groups node0 interfaces fxp0 unit 0 family inet address 192.168.2.21/26 set groups node0 system host-name SRX5800-1 set chassis cluster reth-count 3 set chassis cluster control-ports fpc 5 port 0 set interfaces fab0 fabric-options member-interfaces xe-4/1/0 # in operational mode user@host> set chassis cluster cluster-id 1 node 1 reboot # after reboot in configuration mode # node 1 - secondary set groups node1 system host-name node1-router set groups node1 interfaces fxp0 unit 0 family inet address 192.168.2.22/26 set groups node1 system host-name SRX5800-2 set chassis cluster reth-count 3

set chassis cluster control-ports fpc 11 port 0 set interfaces fab1 fabric-options member-interfaces xe-10/1/0 set set set set set set chassis chassis chassis chassis chassis chassis cluster cluster cluster cluster cluster cluster redundancy-group redundancy-group redundancy-group redundancy-group redundancy-group redundancy-group 0 0 1 1 1 1 node 0 priority 100 node 1 priority 1 node 0 priority 100 node 1 priority 1 preempt gratuitous-arp-count 4

set chassis weight 255 set chassis weight 255 set chassis weight 255 set chassis weight 255

cluster redundancy-group 1 interface-monitor xe-4/1/2 cluster redundancy-group 1 interface-monitor xe-4/1/3 cluster redundancy-group 1 interface-monitor xe-10/1/2 cluster redundancy-group 1 interface-monitor xe-10/1/3

{primary:node0}[edit] admin# set apply-groups node0 {primary:node0}[edit] admin# set apply-groups node1

# - reth interfaces # reth0 - Internal interface set interfaces xe-4/1/2 gigether-options redundant-parent reth0 set interfaces xe-10/1/2 gigether-options redundant-parent reth0 # reth1 - External interface set interfaces xe-4/1/3 gigether-options redundant-parent reth1 set interfaces xe-10/1/3 gigether-options redundant-parent reth1 verification command show chassis cluster ? Possible completions: interfaces Display chassis-cluster interfaces statistics Display chassis-cluster traffic statistics status Display chassis-cluster status