Вы находитесь на странице: 1из 4

11.

Minimum bow height and reserve buoyancy (Annex I, regulation 39)


The bow height (Fb), shall be not less than :

Fb = (6075( L / 100) 1875( L / 100) 2 + 200( L / 100) 3 ) x(2.08 + 0.609Cb 1.603C wf 0.0129(L / d1 )
where :
Fb = minimum bow height, in milimetres
L = 150.30
m
B = 27.70
m
d1 = 9.775
m
Cb = 0.843
Cwf = waterplane area coefficient forward of L/2
Awf
C wf =
(L / 2)B
= 1868.680/((150.300/2) x B)
= 0.8977
Awf = waterplane area forward of L/2 at d1
=

1868.680

m2

Then :
Fb =

9130.725
-4235.641875
679.0581054
0.956204931
5330.021333

(6075 x (150.3/100) - 1875 x (150.3/100) ) + 200 x (150.3/100) )


x (2.08 + 0.6090.843-1.603 x 0.898-0.0129 x (150.3/9.775))

Fb =

5330.02

mm

12. Summer freeboard (Annex I, regulation 40)


The minimum freeboard in summer shall be :
Correction for block coeffecient
Correction for depth
Deduction for superstructure and trunk
Correction for Sheer
Minimum freeboard in summer (Fso) =

=
=
=
=

2209.637
373.750
-32.956
542.019
3092.450

Height of Summer freeboard (H)


H = Fso + tFH +hFH
tFH = Sheer height at forward perpendicular
= 0
mm
hFH = Height of forecastle at forward perpendicular
= 3100
mm
H = 3092.450 + 0 + 3100
= 6192.450
mm
Hmin (Fb) = 5330.021
mm
H > Hmin
Freeboard in summer
Fs1 = Fso
= 3092.450
mm
15. Fresh water freeboard (Annex I, regulation 40)
the minimum fresh water shall be obtained :
FW freeboard = Summer Freeboard - /4T
4x
where :
= Displacement at the Summer Load Line
=
23627.090 tonnes
T = TPC at the Summer Load Line
=
37.716 ton/cm
FW freeboard = 309.25-23627.09/(4x37.72)
=
152.633 cm
=
1526.332 mm
16. Result :
The minimum freeboard in
Summer
(S) =
3092.45 mm
Fresh water (FW) = 1526.332 mm
DECK

FW

T
S
W
WNA

603C wf 0.0129(L / d1 )

mm
mm
mm
mm
mm