Вы находитесь на странице: 1из 74

PROYECTO DE NORMAS DE DISEO DE INSTALACIONES INTERIORES PARA LA CIUDAD DE SALTILLO, COAHUILA, MXICO

YAMIL MELO VISAIRO

TESIS

Presentada como requisito parcial para obtener el Grado de

Maestro en Ciencias en GESTIN INTEGRAL DEL AGUA UNIVERSIDAD AUTNOMA DE COAHUILA U. A. de C. FACULTAD DE INGENIERA

Saltillo, Coah. junio de 2005

60

NDICE
CAPTULO PGINA

Resumen .....1 I II Introduccin ....3 Breves Antecedentes Generales .5 2.1 2.2 2.3 2.4 2.5 III Ubicacin Geogrfica .6 Clima ....7 Orografa ..8 Poblacin .....9 Situacin Actual y Hbitos de Consumo ..10

Planteamiento de la Investigacin .13 3.1 3.2 3.3 3.4 Objetivo ...13 Justificacin .......14 Marco Terico .......14 Fundamentos Tericos ........19

IV

Diseo de la Investigacin ..60 4.1 4.2 4.3 4.4 Planteamiento del Problema ....60 Interrogante General de la Investigacin ...60 Desarrollo de la Investigacin .....60 Aforo ....71

Resultados .73 5.1 5.2 Comparativo de Clculos y Aforos .73 Otras Consideraciones .76

61

VI

Conclusiones .78 6.1 6.2 6.3 6.4 Interrogante General de la Investigacin ...78 Propuesta ....78 Objetivo .......79 Justificacin ....79

VII VIII

Discusin ....83 Propuesta y Recomendaciones .....90 Bibliografa .....98 Currculum Vitae ......101 Anexos ...102

62

RESUMEN

Universidad Autnoma de Coahuila Facultad de Ingeniera Maestra en Gestin Integral del Agua Nombre Melo Visairo Yamil Titulo PROYECTO DE NORMAS DE DISEO DE INSTALACIONES INTERIORES PARA LA CIUDAD DE SALTILLO, COAH. MXICO. Palabras clave: Instalaciones Interiores, Normas y Mtodos Asesor Principal: Dr. Manuel Gerardo Garca Cardona En esta investigacin se presenta un proyecto de Norma para el diseo de Instalaciones Interiores en edificaciones, derivada del Estudio de Diferentes Normas de Diseo y Mtodos para Instalaciones Interiores, aplicadas en pases de Amrica Latina incluido Mxico y Espaa, consideradas ellas por su similitud en cuanto a usos y costumbres sobre el recurso agua. La informacin de la investigacin, se bas tambin en la utilizacin de dos mtodos de diseo; uno propuesto y difundido extensamente en el mundo desarrollado por Hunter, que considera como gastos de diseo las Unidades de Consumo que utiliza cada mueble sanitario, otro mtodo, derivado del anterior y propuesto en su obra por el Ingeniero Rafael Prez Carmona, en el que la diferencia estriba en que ste considera un coeficiente de simultaneidad en la operacin de los muebles que componen el sistema que se analiza, y adicionalmente se propuso uno mas, basado en la experiencia del sustentante en el que se tomaron los gastos directos que cada mueble sanitario requiere y no las unidades de consumo, utilizndose los grficos de Hunter para el clculo de dimetros y prdidas por friccin y accesorios y los coeficientes de simultaneidad propuestos por Prez Carmona. Se asienta tambin que estos mtodos fueron revisados utilizando la frmula de Manning a fin de verificar cada uno de los mtodos propuestos y tambin, se propuso un sistema hidrulico tpico de nuestro medio, el cual fue construido en una casa habitacin y del que se obtuvieron mediciones de los gastos brindados por cada mueble y se compararon estos gastos con los seis clculos efectuados, obtenindose as, una informacin precisa que sirvi para tomar una decisin sobre la mejor opcin de diseo de las instalaciones interiores a efecto de ser presentada como una propuesta para la realizacin de una norma sobre el particular. Derivado del estudio de las diferentes Normas y de los resultados obtenidos en clculo y de los aforos, se estableci una propuesta de Norma para el Diseo de Instalaciones Interiores para las viviendas de la ciudad de Saltillo, Coahuila, la cual toma en consideracin la limitante del recurso agua as como tambin la forma en que son abastecidas las viviendas y el tipo de suministro a los muebles sanitarios que es tpico en nuestra localidad.

63

Esta propuesta presentada, no pudo ser confrontada con las normas estudiadas, puesto que a excepcin de la Normativa Espaola, que establece parmetros de diseo precisos para sistemas trabajando a presin y no por gravedad, las dems normas no contemplan en absoluto ningn parmetro de diseo, por lo cual, la propuesta fue obtenida directamente de los estudios de los diferentes mtodos utilizados y de la experiencia personal del sustentante sobre el tema.

64

INTRODUCCIN

En el presente captulo, se hace una breve descripcin del contenido de cada uno de los captulos que forman esta tesis. Captulo II Trata de los ms breves antecedentes relacionados con las

instalaciones interiores en edificaciones, conteniendo datos histricos desde la fundacin de Saltillo, su ubicacin geogrfica, datos climticos, orografa, datos poblacionales y la situacin actual y hbitos de consumo de la poblacin. Captulo III Trata sobre el planteamiento de la investigacin, as como el marco

terico y los fundamentos tericos sobre los que se cimientan el diseo de instalaciones interiores en diversos pases, incluido el nuestro. Se incluye tambin el objetivo, justificacin y la literatura consultada. Captulo IV Diseo de la investigacin, inicia desde el planteamiento del problema, interrogante general de la investigacin y el desarrollo de la misma, a travs del diseo de una red domstica tpica de nuestro medio, realizado el clculo con los mtodos de Hunter, Prez Carmona y el propuesto por esta investigacin, se incluye tambin una comparativa del clculo utilizando la frmula de Manning. Captulo V Resultados de la investigacin, se presenta una comparativa de los

clculos efectuados por los mtodos propuestos, mismos que se correlacionan con los aforos realizados al sistema construido y adems, se incluye una consideracin extra sobre la dotacin de agua por persona y por da que se debe normar en Saltillo, Coah.. Captulo VI Conclusiones, este apartado presenta en forma resumida las

conclusiones obtenidas, dando respuesta a la interrogante de la investigacin, a la propuesta presentada, al objetivo de la misma y a la justificacin de la investigacin,

65

con un breve resumen sobre el impacto del ahorro del agua y los costos que se generan. Captulo VII Discusin, se presenta un anlisis sobre los mtodos y normativas estudiadas, as como su grado de utilizacin o no en la presente investigacin. Captulo VIII Propuesta, este apartado contiene las recomendaciones sobre los parmetros de diseo que se requiere en nuestra ciudad, as como algunas consideraciones sobre la calidad de materiales, pruebas del sistema, la forma en que el diseo debe realizarse y adems, algunos aspectos constructivos y normativos propios de la autoridad competente, que a juicio del sustentante deben incluirse en la reglamentacin respectiva.

66

II

BREVES ANTECEDENTES GENERALES

De acuerdo a los documentos existentes en el Archivo Municipal de Saltillo, (de aqu en adelante AMS-1975), la ciudad fue fundada en el ao 1577 por tropas espaolas comandadas por el capitn Alberto del Canto, dndosele el nombre de Villa de San Esteban de la Nueva Tlaxcala; posteriormente se trajeron a indgenas de Tlaxcala para poblar esta regin de Mxico debido a que las tribus asentadas en el valle, denominados Guachichiles y tambin llamados Chichimecas eran muy belicosos y por lo mismo no fueron fcilmente conquistados; la fundacin de Saltillo obedeci precisamente a que el valle estaba abastecido por infinidad de manantiales, mismos que fueron utilizados para riego de parcelas y para uso domstico durante un poco mas de 300 aos, lo que provoc que en poco tiempo el valle fuera prspero. En 1898 se celebra el contrato para la instalacin de las tuberas de Agua y Drenaje de la ciudad, siendo terminadas en 1903 y que abarc solamente la parte cntrica de la ciudad, naciendo a la par las instalaciones interiores de las edificaciones; para esta fecha el agua del manantial Ojo de Agua utilizado para abastecimiento era ya considerado insuficiente para dotar a toda la poblacin del suministro de agua. En 1906 debido al desperdicio del agua que la poblacin realizaba, se oblig al municipio a instalar medidores para controlar el consumo. En 1926 debido la red de abastecimiento, la cual pas a ser propiedad de la ciudad en 1951. Para 1947 los servicios eran psimos, ello debido a la antigedad del sistema y al tipo de materiales empleados. Para finales del perodo de Gral. Fenecio Lpez Padilla se empezaron a eliminar las caeras de 1903 y se instalaron colectores y una nueva red de mayor capacidad, as como tambin se perforaron varios pozos profundos para incrementar el caudal de abastecimiento a la poblacin. En 1963 y debido a la demanda existente, se decide perforar en la zona de Loma Alta nuevos pozos habindose obtenido un buen caudal, por lo cual se construyeron las lneas de alimentacin necesarias para su conduccin en los sectores no al incremento de la poblacin, el Sr. Jos de Len obtuvo una concesin para extender

67

abastecidos. Durante estos 72 aos al igual que hoy, la solucin que se ha

venido

aplicando, es la de buscar nuevas fuentes de abastecimiento para hacer frente a la demanda de la poblacin, ya que al carecerse de ros, presas o lagunas, la bsqueda se enfoca directamente hacia el agua subterrnea.

2.1

UBICACIN GEOGRFICA El Estado de Coahuila colinda al norte con los Estados Unidos de Amrica, al

oriente con el Estado de Nuevo Len, al poniente con los Estados de Durango y Chihuahua y al sur con los Estados de Durango, Zacatecas y San Lus Potos. La ciudad de Saltillo se encuentra en una localizacin entre los 243213 y 261926 de latitud norte y 1001212 y 1024024 de longitud oeste, estando a una altura media de 1,460 metros sobre el nivel medio del mar. (Surez S. 1994)

Est ado sU n id os d

eA m r ic a

Coahuila

Saltillo

Fig. 1

Ubicacin geogrfica de Saltillo

68

en la Repblica Mexicana

2.2

CLIMA Al sur del municipio se registran subtipos de climas secos semiclidos; al

suroeste subtipos semisecos templados y grupos de climas secos y semifros, en la parte sureste y noreste; la temperatura promedio anual es de los 20 a los 8.1 C, con temperaturas extremas de 38 y -5 C en verano e invierno respectivamente; la precipitacin promedio anual en el sur del municipio es de 300 a 400 mm; al centro tiene un rango de 400 a 500 mm y al norte de 300 a 400; con un rgimen de lluvias en los meses de Abril, Mayo, Junio, Julio, Agosto, Septiembre, Octubre y escasas en Noviembre, Diciembre, Enero, Febrero y Marzo; los vientos prevalecientes tienen una direccin noreste con velocidades medias de 22.5 Km/hr; la frecuencia anual de heladas es de 20 a 40 das en la parte norte-noreste y suroeste; en la parte sureste, noroeste, suroeste, sureste, noreste y este de 40 y 60 das, y granizadas de 0 a 1 das en el norte, noreste y suroeste, y en la parte sureste 1 a 2 das. (Comisin Nacional del Agua, de aqu en adelante CNA-1984)

69

Fig. 2

Distribucin de climas en el Municipio de Saltillo

2.3

OROGRAFA El valle de Saltillo se encuentra rodeado en su mayor parte por un nudo

montaoso que se desprende de la Sierra Madre Oriental; algunas de las sierras principales son, Playa Madero, la Sierra El Laurel, la Sierra Zapalinam y la Sierra Hermosa, donde se pueden encontrar picos de hasta 3,140 metros sobre el nivel medio del mar, lo cual le otorga caractersticas especiales en cuanto al tipo de vegetacin y clima; esta situacin hace que el valle cuente con pendiente predominantes hacia el norte, y cuando existen precipitaciones (normalmente de corta duracin y copiosas), propicie que el agua de escorrenta sea enviada con excesiva velocidad fuera del rea urbana, no permitiendo que existan infiltraciones que pudieran alimentar los acuferos dentro de la zona del valle. (CNA-1984)

70

Fig. 3

Orografa del Municipio de Saltillo

2.4

POBLACIN De acuerdo a los censos realizados por el Instituto Nacional de Estadstica y

Geografa (INEGI 2000), la ciudad ha sufrido a partir de los ochentas un crecimiento exponencial, siendo la tasa de la ciudad de Saltillo mayor a la del resto del estado, sta es de 2.22 % en la ciudad y de 1.5 % en el resto del estado. El grfico siguiente muestra el crecimiento de la poblacin, en el cual se puede observar el que ha tenido la ciudad a partir de 1980, ello es debido a que a partir de ese ao, se han instalado diversas maquiladoras y fbricas de la industria automotriz. Este crecimiento ha repercutido tambin en la demanda de viviendas y por lo mismo, en la demanda de agua. Por otra parte, se asienta que debido a la inmigracin de trabajadores hacia la ciudad de Saltillo, los usos y costumbres de la poblacin han sufrido algunas transformaciones al inicio de la inmigracin, pero se ha observado tambin que, despus de un cierto tiempo, los llegados a la ciudad se adaptan a los usos y costumbres de la poblacin nativa.

600,000 500,000 Habitantes 400,000 300,000 200,000 100,000 0 1900 1926 1947 1950 1960 1970 1980 1990 1995 2000 Aos

71

Fig. 4

Crecimiento Poblacional de la Ciudad de Saltillo, Coah.

2.5

SITUACIN ACTUAL Y HBITOS DE CONSUMO La ciudad de Saltillo, capital del Estado de Coahuila de Zaragoza, cuenta con

una poblacin de 578,046 habitantes, distribuidos en 520 colonias, de las cuales el 90 % cuentan con los servicios de drenaje y agua potable (Aguas de Saltillo, informacin directa del Ing. Francisco Redondo Castro, Gerente de Planeacin de aqu en adelante AGSAL-2004), estando preparadas estas edificaciones con redes interiores de distribucin, las cuales en su mayora son abastecidas por medio de tinacos colocados en las partes superiores de sus viviendas. Estas redes de agua potable interiores sobre todo en las zonas que circundan la ciudad y en especial las colonias con asentamientos irregulares, han sido construidas sin que mediara algn tipo de clculo, mas bien obedecen a lo que los ocupantes creen necesario instalar para hacer funcionar sus aparatos sanitarios y tambin en muchos de los casos, a los recursos de que dispongan para tal efecto; se indica adems, que a la fecha no existe ningn procedimiento oficial que les norme los dimetros mnimos a considerar, as como las condiciones que se deben de cumplir para que sus sistemas operen satisfactoriamente. Se asienta tambin que, las edificaciones del rea urbana que forman la ciudad de Saltillo, han sido construidas utilizando procedimientos y mtodos de acuerdo al conocimiento y criterio del proyectista, sin que la normatividad existente pueda realizar alguna observacin al respecto, ya que como se indic anteriormente, no existe y por lo mismo, las instalaciones as proyectadas pueden estar sobredimensionadas o subdimensionadas. La ciudad de Saltillo, actualmente es abastecida por 62 pozos profundos (el total que existe para operar es de 110 pozos), los cuales suministran a la poblacin un caudal de 1,400 lts/seg; considerando la poblacin de 578,046 habitantes, nos arroja que la dotacin por habitante y por da es de 209.26 litros en promedio. El servicio que proporciona la red es por tandeo, aunque a la fecha existe una zona de la ciudad donde el suministro es diario pero no continuo y en el resto de la ciudad es terciado. (AGSAL)

72

Segn estudio realizados en la ciudad (AGSAL), el mximo consumo de agua se localiza en la utilizacin del sanitario, el cual llega a consumir el 40 % de la dotacin total, ya que a pesar de que actualmente se encuentran en el mercado sanitarios que operan con un tanque bajo de capacidad de 6 litros, tambin es cierto que las edificaciones antiguas con tal de conservar al inmueble en condiciones originales, se sigue en muchos de ellos utilizndose sanitarios de una capacidad de 12 a 19 litros. Otros lugares de las viviendas que absorben bastante de la dotacin suministrada es en el bao diario y el lavado de ropa, ya que en la ciudad se utiliza en viviendas de nivel medio y superior lavadoras elctricas, que aunque es una ayuda para el ama de casa, es tambin cierto que utiliza mas agua que cuando el lavado se realiza a mano. Es conveniente asentar tambin que en verano, debido a las altas temperaturas predominantes, la utilizacin de agua es mxima, sin embargo y tambin debido a la falta de lluvias, los niveles de los acuferos sufren severos decaimientos, mismos que a la fecha no se han podido recuperar y se llega al grado del desabasto de agua a la poblacin. La siguiente tabla proporciona la distribucin media del agua en los hogares de la ciudad de Saltillo. (AGSAL)

Sanitario Regadera Lavado de ropa Cocina Preparacin de alimentos Varios

40 % 30 % 15 % 6% 5% 4%

Tab. 1 Distribucin de agua por servicios en las viviendas De la ciudad de Saltillo

73

Actualmente, la Direccin de Desarrollo Urbano, dependiente del Ayuntamiento de Saltillo, Coah., es la instancia encargada de revisar, autorizar y otorgar el permiso correspondiente a la construccin de edificaciones; su marco normativo es el Reglamento de Construccin para el Estado de Coahuila y la Ley para los Servicios de Agua Potable, Drenaje y Alcantarillado en los Municipios del Estado de Coahuila, documentos que sern analizados en captulos posteriores.

74

III

PLANTEAMIENTO DE LA INVESTIGACIN

Dentro del rea urbana de la ciudad de Saltillo, se han realizado construcciones que si bien es cierto que en espacios responden a las necesidades de sus ocupantes, es tambin cierto que los diseos de las redes interiores de agua potable han sido diseados de acuerdo al criterio propio del proyectista, criterios que son variados en la utilizacin de mtodos no propios de la regin, lo que trae consigo que los sistemas as proyectados puedan tener un sobredimensionamiento o subdimensionamiento, ello segn el mtodo utilizado, lo cuales responden a los criterios de otros pases y no al propio. Para el diseo de redes interiores existen en el mundo diversas normas, mismas que han sido desarrollados para satisfacer las necesidades de la poblacin donde se generaron, tomando en cuenta sus propios factores como disponibilidad del agua y hbitos de consumo de la poblacin. En Saltillo, se utiliza la Ley para los Servicios de Agua Potable, Drenaje y Alcantarillado en los Municipios del Estado de Coahuila (Gob. De Coah. 2001), el cual es una copia del Reglamento del Servicio de Agua y Drenaje para el Distrito Federal y que no est normado en base a la tipologa de la poblacin ni a la disponibilidad del agua, por lo cual es necesario estudiar diferentes normas de diseo para que en base a estas, obtener una que se adecue a las necesidades de nuestra poblacin. A la fecha se utiliza comnmente como mtodo de diseo el propuesto por Hunter, el cual toma en cuenta como parte principal del diseo las Unidades de Consumo, equivaliendo cada unidad de consumo a unos 25 litros por minuto.

3.1

OBJETIVO Estando asentada la ciudad de Saltillo sobre una zona donde el agua es

escasa, es menester contar con un reglamento de diseo de redes interiores

75

adecuado a nuestro medio, el cual garantice de una manera ptima la operacin del sistema, toda vez que permita disear stas con parmetros propios y confiables.

3.2

JUSTIFICACIN Siendo Saltillo una ciudad en expansin constante, se requiere de la

regulacin en el mbito de las instalaciones interiores, lo que se traducir en unificar criterios diversos de diseo, instalaciones interiores eficientes acordes a nuestra disponibilidad del agua, ahorro en costos de instalaciones, ahorro en pagos de servicio y sobre todo, ahorro del vital lquido para futuras generaciones.

3.3

MARCO TERICO

Hidrulica Parte de la Fsica que estudia las leyes que rigen el comportamiento de los lquidos y particularmente el del agua. Trueba C. (1998) Hidrodinmica - Parte de la Hidrulica que estudia las propiedades que tiene el agua cuando est en movimiento. Trueba C. (1998) Tubo se considera que un conducto cerrado est trabajando como tubo cuando dentro de l se tiene un lquido que llena completamente el conducto y por lo cual ejerce cierta presin sobre las paredes del conducto. Trueba C. (1998) Si consideramos una seccin transversal del conducto que trabaja como tubo, por el cual pasa una cantidad de agua, se tendr El volumen de agua que pasa por esa seccin recta en la unidad de tiempo se llama GASTO y se designa comnmente con la letra Q; a la velocidad con la que est pasando el agua por esa seccin se designa con la letra v. El gasto entonces se puede calcular con la expresin:

76

Q=S.v

donde S es la seccin transversal del conducto

Si consideramos que la seccin del tubo es circular, podemos tener la expresin anterior en funcin del dimetro del mismo. Trueba C. (1998)

Q=

2 d v 4

Cuando el rgimen es permanente y el conducto tiene dimetro variable (o en general seccin variable), la velocidad es diferente para cada seccin e inversamente proporcional a ella, de tal manera que:

Q = S1v1 = S2v2 = S3v3 = = Snvn A esta relacin se le llama Ecuacin de Continuidad Partiendo de la ecuacin de continuidad y bajo ciertas consideraciones, se llega al Teorema de Bernoull, y casi todas las consideraciones de las que se parten en hidrulica estn basadas en este principio. Si consideramos la figura siguiente, la cual se tiene como referencia un plano horizontal P para medir las cotas de las dos secciones, Trueba C. (1998), se tiene: h1 = cota de la seccin 1 h2 = cota de la seccin 2 v1 = velocidad en la seccin 1 v2 = velocidad en la seccin 2 p1 = presin del lquido en la seccin 1 p2 = presin del lquido en la seccin 2

77

S1

dl1
v1

h1 h2
S2 v2 P

dl2

Fig. 5

Diagrama de desalojo de una masa lquida

Para considerar el principio mecnico de la igualdad de trabajo y de la variacin de la fuerza viva es necesario considerar un desalojamiento de la masa lquida, tenindose al final la siguiente expresin: v12 p1 v2 p + = h2 + 2 + 2 2g w 2g w

h1 +

sta es la expresin matemtica del Teorema de Bernoull y se interpreta diciendo que: Si no hay prdidas de carga entre dos secciones de la circulacin de un lquido en rgimen permanente, la suma de las cargas de altura o posicin, de velocidad y de presin es constante en cualquier seccin del lquido Si se considera que el lquido circula por un conducto cualquiera, se tiene que se produce una prdida por frotamiento entre el lquido y la superficie del conducto, por lo cual la igualdad entre los dos miembros de la expresin anterior no se establece y es necesario agregar un trmino que represente las prdidas para poder establecer dicha igualdad, representndose el nuevo trmino de prdidas por Hf v12 p1 v2 p + = h2 + 2 + 2 + H f 2g w 2g w

h1 +

78

Cuando existe circulacin de un lquido dentro de un tubo, las partculas del lquido pueden moverse bajo dos consideraciones: una, que la direccin que sigan sea paralelo al eje del tubo, y otra, que sigan un movimiento indefinido. Cuando sucede el primer caso, se dice que el lquido est dentro de un rgimen laminar o tranquilo; en el segundo caso se dice que el lquido est dentro de un rgimen turbulento o turbillonario. Cuando el lquido inicia el movimiento dentro del tubo, si la velocidad es pequea el rgimen ser laminar y en la medida que se aumenta esta velocidad, se pasa al rgimen turbulento. Al paso de un rgimen a otro, existe una velocidad crtica, conocidas como crtica alta cuando pasa de laminar a turbulento y a la inversa se conoce como velocidad crtica baja. Estas velocidades crticas han sido verificadas por Osborne Reynolds (1883), obtenindose estos valores por medio de la ecuacin: Trueba C. (1998) vDp u

R=

donde v, p, y U son la velocidad, densidad y viscosidad del lquido y D es el dimetro del conducto. A travs de numerosos experimentos se ha llegado a definir que cuando en un escurrimiento se tiene un nmero de Reynolds menor de 2000 el rgimen es laminar o tranquilo y cuando este nmero es mayor de 3000 Trueba C (1998) el escurrimiento es turbulento, siendo ste rango como de transicin. Existe otro criterio al respecto; la Compaa Inteltech (2005) que se dedica a la difusin de la tecnologa en el mbito educativo, restringe el rango a 2300 como nmero crtico de Reynolds, indicando que un nmero menor a ste corresponde a un rgimen laminar, y arriba de l, el rgimen es turbulento. Frmulas para el clculo de tuberas.

79

Cuando un lquido circula por un tubo, sufre prdidas en su energa; estas prdidas se deben a las siguientes causas Trueba C. (1998): a) Prdidas por frotamiento b) Prdidas por entrada c) Prdidas por salida d) Prdidas por sbito ensanchamiento del tubo e) Prdidas por sbita contraccin del tubo f) Prdidas por obstruccin en el tubo (vlvulas) g) Prdidas por cambio de direccin (codos, tees, etc.) Generalmente la prdida ms importante es debida a la friccin, aunque en ciertos casos algunas de las otras pueden ser de mayor importancia y en otros incluso no existir. En cada caso particular, las que tienen mayor valor se les llama prdidas principales y a las de valores pequeos, prdidas secundarias. La frmula mas usada para el clculo de tuberas es la Frmula de Chezy modificada por Darcy, la cual es emprica, resultado de la experiencia y por lo tanto no puede demostrarse. Esta frmula considera que las prdidas por friccin dependen del material y del estado de la tubera (coeficiente f), adems de la longitud de la tubera, el dimetro del conducto y la velocidad a la que circula el lquido. Trueba C (1998) L v2 d 2g

Hf = f

Otra magnitud que es conveniente considerar en el estudio de los tubos es el Gradiente Hidrulico, el cual se define como la pendiente hidrulica de la tubera y est en estrecha relacin con el nmero de Reynolds, pues se ve afectada por la mayor o menor turbulencia del lquido y es de vital importancia en el estudio del escurrimiento del agua en tuberas, ya que conforme un lquido se desplaza por un tubo, la energa disponible se reducir conforme avance dentro de l.

80

Piezmetros

Gradiente Hidrulico

H L

Fig. 6

Gradiente Hidrulico

Cabe aclarar que para el clculo de redes interiores, se debe conocer el Caudal Mximo Probable, esto es, el gasto que se deber suministrar en horas pico a los muebles, el cual se evala de acuerdo al nmero de muebles instalados, el nmero de ellos que puedan operar simultneamente y el gasto que utilizarn.

3.4

FUNDAMENTOS TERICOS Tradicionalmente el mtodo utilizado para disear redes interiores de agua

potable ha sido el denominado Mtodo de Hunter, el cual consiste en evaluar los caudales que requieren los aparatos durante un minuto, tomando el autor un gasto unitario llamado Unidad de Consumo, misma que equivale a unos 25 litros por minuto segn lo marca el apartado 3 del Captulo III Proyecto de un suministro de agua. Proteccin contra los incendios del libro analizado. (Instalaciones en los Edificios Gay.Fawcett.McGuinnes.Stein, 1999 de aqu en adelante Gay.Fawcett) Existe tambin otro mtodo que se utiliza con menor frecuencia, el cual est basado en el Mtodo Hunter, tomndose para diseo las mismas unidades de consumo que propone el Dr. Hunter en su libro, la diferencia estriba en que en este mtodo se toma en cuenta el nmero de salidas que tiene cada aparato para con ello, 81

proporcionar un coeficiente de simultaneidad, ya que el autor que expone el tema, el Ing. Rafael Prez Carmona, (El Agua Tomo I-1988), indica que en un sistema con dos o tres aparatos instalados, es concebible que todos funcionen al mismo tiempo, pero en un sistema con doscientos aparatos instalados, no es concebible que funcionen todos a la vez. Este coeficiente que introduce Prez Carmona, permite que las tuberas sean dimensionadas con un menor gasto y por lo consiguiente, se obtienen menores dimetros en el sistema. Siendo la regadera el elemento que presenta mayor problemtica dentro de las instalaciones interiores, se utilizar para analizar el Mtodo propuesto en la investigacin, los gastos que proporciona la Comisin Nacional del Agua dentro de su Norma Oficial Mexicana NOM-008-CNA-1998, Regaderas Empleadas en el Aseo Corporal - Especificaciones y Mtodos de Prueba, marcando en sus apartados lo siguiente: 5. CLASIFICACIN Las regaderas objeto de esta norma se clasifican de acuerdo a su intervalo de presin esttica de operacin para la cual estn diseadas, segn se indica en la siguiente tabla.

Regadera Tipo Baja Presin Media Presin Alta Presin

Rango de Presin de Trabajo kPa (kgf/cm ) 20 a 98 (0.2 a 1.0) 98 a 294 (1.0 a 3.0) 294 a 588 (3.0 a 6.0)
2

Niveles de Edificacin 1a4 De 4 a 12 o equipo hidroneumtico Mas de 12 o equipo hidroneumtico

Fig. 7

Rangos de operacin de regaderas

8.- DETERMINACIN DEL GASTO

82

REGADERA TIPO Baja Presin Med. Presin Alta Presin 1 kPa = 0.0102 kgf/cm2

LMITE INFERIOR PRESIN GASTO MNIMO kPa (kgf/cm2) l/min 20 (0.2) 4.0 98 (1.0) 4.0 294 (3.0) 4.0

LMITE SUPERIOR PRESIN GASTO MXIMO kPa (kgf/cm2) l/min 98 (1.0) 10.0 294 (3.0) 10.0 588 (6.0) 10.0

Fig. 8

Gastos y presiones recomendadas en regaderas

Para llevar a cabo la presente investigacin se revisaron los siguientes Mtodos y Normativas, que se presentan a continuacin. a) MTODOS ANALIZADOS. MTODO HUNTER PARA INSTALACIONES INTERIORES

INSTALACIONES EN LOS EDIFICIOS 1999) Segn el Dr. Hunter, los aparatos requieren de las siguientes unidades de consumo segn el uso que se d, pblico o particular.
APARATO O GRUPO DE APARATO Water closet Water closet Lavabo Baera Ducha Fregadero Cuarto de bao completo Cuarto de bao completo Lavadero USO PBLICO 10 5 2 4 4 4 USO PARTICULAR 6 3 1 2 2 2 8 6 3 FORMA DE INSTALACIN Vlvula de descarga Tanque de descarga Grifo Grifo Vlvula mezcladora Grifo Vlvula de descarga para el WC Tanque de descarga para el WC Grifo

Tab. 2 Tabla de aparatos sanitarios, consumos y forma de instalacin.

As tambin, el texto mencionado presenta una tabla en la que se marcan los caudales y presiones para distintos aparatos sanitarios.

PRESIONES Y CAUDALES REQUERIDOS PARA LOS DISTINTOS APARATOS

83

APARATO Lavabo Grifo de cierre automtico Lavabo pblico Fregadero Baera Lavadero Ducha Sanitario con tanque de descarga Sanitario con vlvula de descarga Migitorio con vlvula de descarga Manguera de jardn de 15 metros

TUBO PULGADAS 3/8 1/2 3/8 1/2 1/2 1/2 1/2 3/8 1 1 1/2

EN

PRESIN KG/CM2 0.58 0.87 0.73 0.36 0.36 0.36 0.58 0.58 0.73 1.46 1.09 2.19

EN

CAUDAL LPM 12 10 15 15 25 20 20 12

EN

75 150 60 20

Tab. 3 Presiones y caudales requeridos para diferentes aparatos sanitarios.

El Dr. Hunter, de acuerdo a ensayos y experiencia ha preparado curvas que permiten obtener el consumo probable mximo en litros por minuto, segn sea el nmero de unidades de consumo instaladas, consumos probables que se dice se presentan a ciertos momentos del da y que permitirn calcular el dimetro del tubo que se requiere instalar. Las curvas siguientes permiten evaluar el Mximo Consumo Probable con el solo dato de las Unidades de Consumo en el tramo. Las curvas presentan dos consideraciones; una para donde predominan en el sistema los aparatos que utilizan vlvulas de descarga o fluxmetros, y el otro para donde predominan los WC de tanque bajo.

84

Fig. 9

Curvas de Hunter para evaluar el Mximo Consumo Probable

Fig. 10 Detalle de Curva de Fig. 10 a mayor escala

Otra consideracin que el autor propone es, la utilizacin de una tabla de equivalencias de prdidas de carga por accesorios convertidas en metros de tubo recto, misma que se presenta a continuacin:

85

en Pulg. 3/8 1 1 1 2 2 3 3 4 5 6

Codo de 90 0.30 0.60 0.75 0.90 1.20 1.50 2.15 2.45 3.05 3.65 4.25 5.20 6.10

Codo de 45 0.20 0.40 0.45 0.55 0.80 0.90 1.20 1.50 1.80 2.15 2.45 3.05 3.65

Tee Giro 0.45 0.90 1.20 1.50 1.80 2.15 3.05 3.65 4.60 5.50 6.40 7.60 9.15

Tee Paso Recto 0.10 0.20 0.25 0.27 0.40 0.45 0.60 0.75 0.90 1.10 1.20 1.50 1.80

Vlvula Compuerta 0.06 0.12 0.15 0.20 0.25 0.30 0.40 0.50 0.60 0.70 0.80 1.00 1.20

Vlvula de Plato 2.45 4.60 6.10 7.60 10.50 13.50 16.50 19.50 24.50 30.00 37.50 42.50 50.00

Vlvula de Angulo 1.20 2.45 3.65 4.60 5.50 6.70 8.50 10.50 12.20 15.00 16.50 21.00 24.50

Tab. 4 Tabla de equivalencias de accesorios en tramos de tubera recta

Los grficos que se presentan a continuacin son tomados del libro de Instalaciones en los Edificios de Hunter, y sirven para obtener dimetros, velocidades y prdidas por 100 metros de tubera recta.

Fig. 11 Grfico para evaluar prdidas en tuberas galvanizadas segn Hunter.

86

Fig. 12

Grfico para evaluar prdidas en tuberas de cobre o plstico, segn Hunter.

Se asienta as mismo que, el libro en mencin solamente hace referencia a que en funcin de las unidades de consumo se obtiene en las curvas el mximo consumo probable, sin que para ello obre un coeficiente de simultaneidad, el cual se entiende (dado que no lo menciona), va implcito dentro las consideraciones que el autor ha tenido en cuenta para el diseo de las curvas utilizadas; se asienta as mismo que es conveniente que la velocidad mxima no supere los 3 mts/seg, ya que de hacerlo, el ruido que provoca el agua al circular, en ocasiones es molesto para los ocupantes de la edificacin.

b)

MTODO PROPUESTO POR ING. RAFAEL PREZ CARMONA EN SU LIBRO EL AGUA (TOMO I 1998)

87

El autor propone la utilizacin del Mtodo Hunter para el clculo de los caudales en instalaciones interiores; la diferencia estriba en la utilizacin de un coeficiente de simultaneidad denominado K, el cual esta en funcin del nmero de salidas del sistema de proyecto y que adems no podr ser nunca menor de 0.20 Prez Carmona incluye en su obra dos tablas que facilitan la labor del proyectista, siendo stas las que se presentan a continuacin.
APARATOS Bao Bao-cocinaservicio Dos baos Dos cocinas Tres baos Tres baos FUNCIONANDO SIMULTANEAMENTE Ducha, lavamanos e inodoro Ducha, lavaplatos e inodoro Dos duchas y un lavamanos Un lavaplatos y un inodoro de servicio Dos duchas, dos lavamanos Dos duchas, un lavamanos, lavaplatos y un inodoro un CAUDAL EN Lts/seg 0.19 0.25 0.25 0.25 0.32 0.44

Tab. 5 Tabla de caudales por servicio

APARATOS Inodoro con fluxmetro Inodoro de tanque bajo Orinal con fluxmetro Orinal de tanque Lavamanos de llave Tina de llave Ducha con mezcladora Fregadero uso oficial de llave Fregadero de cocina en hotel restaurant de llave Bidet de llave Lavaplatos Lavadero de 1 a 3 compartimientos de llave Lavadora

USO PBLICO
UNIDAD CAUDAL Lts/seg.

USO PRIVADO
UNIDAD CAUDAL Lts/seg.

10 5 10 3 2 4 4 3 4

0.50 0.25 0.50 0.19 0.13 0.22 0.22 0.19 0.22

6 1 1 2 2

0.32 0.06 0.06 0.13 0.13

1 2 1 3

0.06 0.13 0.06 0.19

Tab. 6 Tabla de caudales por aparato y segn el tipo de servicio

Para obtener el gasto mximo instantneo gasto mximo probable, el autor propone la utilizacin de un coeficiente de simultaneidad, el cual est en funcin del nmero de salidas de cada mueble o aparato y del nmero de ellos que pueden estar en uso simultneo, para lo cual propone lo siguiente: 88

NMERO DE APARATOS INSTALADOS Tres (3) De 4 a 15 Ms de 16

EN FUNCIONAMIENTO Uno (1) Dos (2) Tres (3)

Tab. 7 Nmero de aparatos instalados y probabilidad de funcionamiento

La tabla siguiente proporciona los coeficientes de simultaneidad en funcin del nmero de salidas, este coeficiente lo denomina con la letra K.

NO. SALIDAS 1 2 3 4 5 6 7 8

VALOR DE K 1.00 1.00 0.70 0.57 0.50 0.45 0.40 0.37

NO. SALIDAS 9 10 11 12 13 14 15 16

VALOR DE K 0.35 0.33 0.32 0.30 0.29 0.28 0.26 0.25

NO. SALIDAS 17 18 19 20 21 22 23 24

VALOR DE K 0.24 0.24 0.23 0.23 0.22 0.22 0.21 0.21

Tab. 8 Coeficiente de simultaneidad segn Prez Carmona

El Ing. Prez Carmona ha concluido tambin a travs de varias investigaciones que las curvas del Dr. Roy Hunter estan significativamente sobre-estimadas, mas sin embargo se asienta tambin que ninguna conclusin ha sido sustentada por las revisiones del modelo de Hunter. Considera tambin que tres unidades de consumo que se dan al inodoro son muchas, ya que de 16 litros del depsito se debe bajar a seis con un rediseo del sifn que contiene. (Actualmente se utilizan depsitos de 9 y 6 litros).

89

Por otra parte, el autor ha elaborado tambin una tabla de equivalencias de accesorios en metros de tubera recta, la cual difiere de las estimaciones que realiza el Dr. Hunter en su libro, siendo esta:

EN Pulgadas 1 1 1 2 2 3 4 5 6 8 10 12

Codo de 90 0.50 0.70 0.80 1.10 1.30 1.70 2.00 2.50 3.40 4.20 4.90 6.40 7.90 9.50

Codo de 45 0.20 0.30 0.40 0.50 0.60 0.80 0.90 1.20 1.50 1.90 2.30 3.00 3.80 4.60

Tee Giro 1.00 1.40 1.70 2.30 2.80 3.50 4.30 5.20 6.70 8.40 10.00 13.00 16.00 19.00

Tee Paso Recto 0.30 0.40 0.50 0.70 0.90 1.10 1.30 1.60 2.10 2.70 3.40 4.30 5.50 6.10

Vlvula de Compuerta 0.10 0.10 0.20 0.20 0.30 0.40 0.40 0.50 0.70 0.90 1.10 1.40 1.70 2.00

Vlvula de Plato 4.90 6.70 8.20 11.30 13.40 17.40 21.00 26.00 34.00 43.00 51.00 67.00 85.00 102.00

Vlvula de Angulo 2.60 3.60 4.60 5.60 6.70 8.50 10.00 13.00 17.00 21.00 26.00 34.00 43.00 51.00

14

10.50

5.30

22.00

7.50

2.10

120.00

60.00

Tab.9 Tabla de equivalencias de accesorios en tramos de tubera recta

El Ing. Prez Carmona utiliza los mismos grficos de Hunter para calcular el dimetro de tubera que se analiza, as como la prdida de tubera por cien metros de desarrollo. Otra consideracin que hace el Ing. Prez Carmona es en base a clculos realizados por l, que un bao completo puede trabajar considerando 3 unidades de consumo, y que es recomendable que el dimetro mnimo de distribucin sea tubera de dimetro de y las derivaciones a los aparatos de dimetro de , sobre todo cuando se utiliza un depsito elevado y con mayor utilidad en viviendas donde la altura a que se coloca el depsito elevado no es suficiente como para proporcionar la presin mnima recomendada a los aparatos, sin embargo, el proporcionar un caudal mayor de agua se traduce en que un aparato no le restar agua a otro que se est utilizando al mismo tiempo y ello permitir una eficiencia mayor en el sistema; as tambin, Prez Carmona propone que las velocidades de proyecto se manejen entre

90

1.2 y 1.5 mts/seg., velocidades que son consideradas por otros autores como las idneas para que el dimetro as encontrado sea el ms econmico.

c)

MTODO PROPUESTO POR FREDERICK S. MERRITT MANUAL DEL INGENIERO CIVIL VOLUMEN II 1985) Este mtodo toma en consideracin lo establecido por la normativa de la Nacional Plumbing Code, ANSI Standard A40.8 (American Society of Mechanical Engineers) para normar la presin y flujo que requieren los diferentes muebles sanitarios, las cuales son:
ACCESORIO Llave ordinaria de lavamanos Llave autocerrante de lavamanos Llave de fregadero de 3/8 de pulgada Llave de fregadero de pulgada Llave de tina Llave de tina de lavandera de pulgada Regadera Llave de bola para inodoro Llave de flujo para inodoro Llave de flujo para mingitorio Manguera de jardn, 50 pies y llave
Tab. 10

PRESIN Libras/pulg2 8.00 12.00 10.00 5.00 5.00 5.00 12.00 15.00 10.00-20.00 15.00 30.00

VELOCIDAD galones/minuto 3.00 2.50 4.50 4.50 6.00 5.00 5.00 3.00 15.00-40.00 15.00 5.00

Tabla de presiones y velocidad de circulacin por aparato

El Manual indica tambin que se deben tomar en cuenta las prdidas de presin en la tubera y las conexiones entre la fuente de suministro y los accesorios, para que se tengan presiones adecuadas en los muebles. Si es necesario pueden emplearse bombas reforzadoras o tanques de gravedad y de presin para poder mantener la presin. Indica tambin que las tuberas para distribuir el agua pueden utilizarse de cobre, bronce, plomo, hierro fundido, hierro forjado, acero o plstico. Se asienta tambin que, el plomo no es apto para utilizarse en sistemas hidrulicos, ya que es un elemento txico y pude ocasionar en grado extremo hasta la muerte al ser humano, por lo cual, su uso se restringe a los drenajes sanitarios, al igual que el 91

hierro sin recubrimiento (no galvanizadas), tiende a oxidarse en presencia de agua y ocasiona que el sta al circular por este tipo de tuberas, presente una coloracin ocre y un sabor desagradable. Por lo anterior, solamente se sugiere utilizar tuberas de cobre, galvanizadas y de plstico, tomando en cuenta que de acuerdo a la presin por manejar, se deber escoger el tipo de ellas que resista dicha presin. El flujo requerido en los muebles sanitarios lo mide por medio de las curvas de Hunter, as como tambin las unidades de consumo y dimetros mnimos estn en funcin de las normas de la Nacional Plumbing Code, mismas que utiliza el libro de Gay.Fawcett mencionado prrafos arriba. Se asienta tambin que, el Manual del Ingeniero Civil no establece la forma en que deba calcularse el dimetro y prdidas de las tuberas; solamente se deduce que al utilizar los parmetros de Hunter, el clculo deba realizarse en la forma en que el libro de Instalaciones en los Edificios establece. As mismo, el Manual marca los dimetros mnimos a considerar en la alimentacin de los muebles sanitarios, mismos que coinciden con lo establecido por Hunter y Prez Carmona, siendo estos:

TIPO DE MUEBLE Tinas Combinacin fregadero y batea Bebedero Lavadora domstica Fregadero de cocina residencial Fregadero de cocina comercial Lavamanos Batea de lavandera 1, 2 3 compartimientos
Tab. 11

en pulgs
3/8

TIPO DE MUEBLE Regadera (cabeza sencilla) Fregaderos (servicios y desperdicios) Fregaderos de flujo por el borde Urinario de tanque lavador Urinario de vlvula de flujo Inodoro de tanque Inodoro de vlvula de flujo Llave de manguera

en pulgs
3/8 1


3/8

Tabla de tubera de alimentacin para diferentes aparatos

92

IV

DISEO DE LA INVESTIGACIN

4.1

PLANTEAMIENTO DEL PROBLEMA La ciudad de Saltillo, Coah. debido a sus usos y costumbres y a la escasez del

vital lquido, ha conservado la forma de abastecer de agua las viviendas, realizndose esta forma por medio de tinacos, sistema que si bien es cierto funciona cuando se dimensiona y construye adecuadamente, es tambin cierto que cuando no se realiza en forma adecuada, brinda una serie problemtica a los ocupantes de la vivienda, como es el uso deficiente de la red cuando funcionan varios aparatos en forma simultnea; ello es debido a que no se cuenta con una reglamentacin 93

adecuada a nuestro medio, sino que se utilizan criterios y mtodos diversos en los cuales las autoridades competentes en el ramo no pueden objetar ni discriminar por no contar con un reglamentacin que les permita hacerlo y es posible encontrar viviendas que bajo el sistema de autoconstruccin, los ocupantes colocan las instalaciones interiores bajo el esquema de ver como se encuentra la vivienda vecina y hacer lo mismo en la suya, por lo cual repito, la eficiencia del sistema no es buena.

4.2

INTERROGANTE GENERAL DE LA INVESTIGACIN Es posible adecuar las normas y mtodos de diseo de instalaciones

interiores que existen en el mundo a las necesidades de Saltillo, Coah. Mxico?

4.3

DESARROLLO DE LA INVESTIGACIN Con el fin de analizar los diferentes mtodos existentes, as como las

normativas antes citadas, se propone realizar el estudio de la red interior de la casa marcada con el nmero 1461-4 de la calle de Francisco Zarco, Zona Centro en la ciudad de Saltillo; la cual consta de una edificacin de una sola planta en la que se localizan tres recmaras, cocina, sala comedor, un estudio y un bao. Los muebles instalados son: un lavabo, un sanitario de tanque bajo, una regadera, un fregadero, un lavadero y una lavadora, mismos que son abastecidos por medio de un tinaco elevado de capacidad 1,100 litros, colocado a 2.20 mts. por encima del nivel de la cebolleta, considerando esta distancia al nivel de salida del tinaco; para el suministro se utiliza tubera de cobre tipo M, y el nmero de ocupantes de la vivienda es de 3 personas. Gay.Fawcett.Mcguinness.Stein y Rafael Prez Carmona propone la utilizacin de lo que ellos llaman unidades de consumo, por lo cual el clculo se realiza siguiendo el criterio que ellos marcan; se incluye tambin un tercer clculo en el que no se utilizan unidades de consumo sino que se hace directamente con los gastos que cada

94

mueble debe recibir y considerando adems que cuando un mueble recibe agua fra y caliente, las unidades de consumo o gasto no se tomar el 100 % de l, sino el 75 %. Como medio de comparacin de los mtodos utilizados, se incluyen tres clculos mas, en los cuales se utilizan los gastos obtenidos de acuerdo a cada autor arriba mencionados, pero el desarrollo de stos se realiza utilizando la frmula de Manning y no los grficos del Dr. Hunter. La tabla siguiente proporciona la informacin que se utiliza para realizar los clculos del sistema.
Aparato Gay Fawcett
(Unidades de consumo)

Prez Carmona
(Unidades de consumo)

100% WC de tanque bajo Regadera Lavabo Fregadero Lavadora Lavadero 3 2 1 2 3 3

75% 3 1.50 0.75 1.50 2.25 2.25

100% 1 2 1 3 3 1

75% 1 1.50 0.75 2.25 2.25 0.75

Propuesto en Invest. (Gasto LPM) 100% 75% 3.60 7.80 3.60 11.40 11.40 3.60 5.85 2.70 8.55 8.55 2.70

Tab. 12 Caudales propuestos para clculo

El dibujo siguiente muestra la isometra de la red que se analiza, haciendo la aclaracin que el tipo de tubera propuesta es de cobre tipo M y que se respeta la consideracin de los diversos autores respecto a que el dimetro de salida para cada aparato ser de pulgada como mnimo. Por otra parte, se considera que en el punto A donde inicia el sistema, existe una carga sobre l que es equivalente a la altura mxima de agua que contiene el depsito cuando est lleno, la cual es de 1.2 mts., y por lo tanto, la presin considerada es de 0.12 Kg/cm2 equivalente a 0.117 Bar.

95

1.20

0.25

0.3

R E G A D E R A

0.87

3.09

0.6 L
LA V A B O

0.89

J S
0.65

.30

0.1

0.2

B O IL E RD R B O IL E R

0.2 H

0.85

B
.150.2

0.95

0.9

K
S A N IT A R I O

N
5 0.35

C
0.74 0.2

O E
0.19

LA V A D E RO

0.95

0.16

FR E G A D E R O

0.71

F
0.2 P 0.78

0.5 G

0.1

LA V A D O R A

0.1

Fig. 13

Isometra de la red interior por analizar

96

CLCULO DE RED SEGN MTODO DEL DR. HUNTER Presin en A = 0.12 Kg/cm2

Tamo U C A-B 19.5 B-C 14.3 C-D 8.25 C-E 6 E-F 3.75 F-G 2.25 B-H 5.25 H-I 1.5 H-J 3.75 J-K 3 J-L 0.75 M-N N-O O-P P-Q N-R R-I R-S 8.25 6 3.75 2.25 2.25 1.5 0.75

Perd. x Long. Long. Perd. x Carga Carga Perd. Q V 100 m tubo Accs. equiv. tramo estat. (-) estat. (+) parc. Presin (lpm) (pulg) (m/seg) (Kg/cm2) (m) (m) (m) (Kg/cm2) (Kg/cm2) (Kg/cm2) (Kg/cm2) (Kg/cm2) 50 1 1/4 1.6 1.1 3.24 3.25 6.49 0.07139 0.309 +0.238 0.338 40 1 1.1 0.73 0.6 1.5 2.1 0.01533 -0.015 0.323 28 3/4 1.5 1.5 1.25 1.5 2.75 0.04125 0.095 -0.136 0.187 22 3/4 1.3 1.2 0.94 1.2 2.14 0.02568 -0.026 0.297 20 3/4 1.1 1.1 0.91 2.7 3.61 0.03971 -0.040 0.257 20 3/4 1.1 1.1 0.98 0.75 1.73 0.01903 -0.019 0.238 21 3/4 1.2 1.2 1.1 1.2 2.3 0.0276 -0.028 0.31 20 3/4 1.1 1.1 1.09 2.85 3.94 0.04334 0.109 -0.152 0.158 20 3/4 1.1 1.1 0.65 1.2 1.85 0.02035 -0.020 0.29 20 3/4 1.1 1.1 0.95 0.75 1.7 0.0187 0.095 +0.076 0.366 20 3/4 1.1 1.1 1.37 1.5 2.87 0.03157 0.05 +0.018 0.308 28 22 20 20 20 20 20 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1.5 1.3 1.1 1.1 1.1 1.1 1.1 1.5 1.2 1.1 1.1 1.1 1.1 1.1 1.15 1.09 1.31 0.78 1.15 0.99 2.32 2.7 1.2 2.7 0.75 1.2 2.85 1.5 3.85 2.29 4.01 1.53 2.35 3.84 3.82 0.05775 0.02748 0.04411 0.01683 0.02585 0.04224 0.04202 0.085 +0.027 -0.027 -0.044 -0.017 -0.026 -0.132 0.05 +0.008 0.214 0.187 0.143 0.126 0.188 0.056 0.196

RED A. CALIENTE

RED AGUA FRA

0.099

97

CLCULO DE RED SEGN MTODO DEL ING. RAFAEL PREZ CARMONA Presin en A = 0.12 Kg/cm Carga Perd. x Carga estat. tramo estat. (-) (+) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) 0.05984 0.309 0.022 0.02915 0.095 0.02574 0.04081 0.01848 0.0275 0.04389 0.109 0.02255 0.01815 0.095 0.03047 0.05 0.04345 0.02739 0.04521 0.01628 0.02805 0.04279 0.04092
2

Tramo U C A-B 16 B-C 12.8 C-D 7.5 C-E 5.25 E-F 4.5 F-G 2.25 B-H 3.25 H-I 1.5 H-J 1.75 J-K 1 J-L 0.75 M-N N-O O-P P-Q N-R R-I R-S 7.5 5.25 4.5 2.25 2.25 1.5 0.75

No. salidas 11 8 5 3 2 1 3 1 2 1 1

K 0.3 0.4 0.5 0.7 1 1 0.7 1 1 1 1

Perd. x Long. Long. 100 m tubo (U C) Q V Accs. equiv. xK (lpm) (pulg) (m/seg) (Kg/cm 2) (m) (m) (m) 5.12 20 3/4 1.1 1.1 3.24 2.2 5.44 4.72 20 3/4 1.1 1.1 0.6 1.4 2 3.75 20 3/4 1.1 1.1 1.25 1.4 2.65 3.68 20 3/4 1.1 1.1 0.94 1.4 2.34 4.5 20 3/4 1.1 1.1 0.91 2.8 3.71 2.25 20 3/4 1.1 1.1 0.98 0.7 1.68 2.28 20 3/4 1.1 1.1 1.1 1.4 2.5 1.5 20 3/4 1.1 1.1 1.09 2.9 3.99 1.75 20 3/4 1.1 1.1 0.65 1.4 2.05 1 20 3/4 1.1 1.1 0.95 0.7 1.65 0.75 20 3/4 1.1 1.1 1.37 1.4 2.77 3.75 3.68 4.5 2.25 2.25 1.5 0.75 20 20 20 20 20 20 20 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.15 1.09 1.31 0.78 1.15 0.99 2.32 2.8 1.4 2.8 0.7 1.4 2.9 1.4 3.95 2.49 4.11 1.48 2.55 3.89 3.72

Perd. parc. Presin (Kg/cm 2) (Kg/cm 2) +0.249 0.369 -0.022 0.347 -0.124 0.223 -0.026 0.321 -0.041 0.28 -0.018 0.262 -0.028 0.341 -0.153 0.188 -0.023 0.318 +0.077 0.395 +0.02 0.338 0.265 0.238 0.193 0.177 0.232 0.09 0.241

RED A. CALIENTE

RED AGUA FRA

5 0.5 3 0.7 2 1 1 1 2 1 1 1 1 1

0.099

0.085 +0.042 -0.027 -0.045 -0.016 -0.028 -0.142 0.05 +0.009

98

CLCULO DE RED PROPUESTO DE LA INVESTIGACIN Presin en A = 0.12 Kg/cm


2

Q No. Tramo (lps) Salidas K A-B 0.996 11 0.32 B-C 0.793 8 0.37 C-D 0.468 5 0.5 C-E 0.325 3 0.7 E-F 0.28 2 1 F-G 0.14 1 1 B-H 0.203 3 0.7 H-I 0.098 1 1 H-J 0.105 2 1 J-K 0.06 1 1 J-L 0.045 1 1 M-N N-O O-P P-Q N-R R-I R-S 0.468 0.325 0.28 0.14 0.143 0.098 0.045 5 3 2 1 2 1 1 0.5 0.7 1 1 1 1 1

Q x K (lps) 0.32 0.29 0.23 0.23 0.28 0.14 0.14 0.1 0.11 0.06 0.05 0.23 0.23 0.28 0.14 0.14 0.1 0.05

Carga Perd. x Long. estat. Perd. Q de Long. Perd. x Carga 100 m tubo estat. (-) (+) parc. Presin diseo Ajuste V Accs equiv. tramo 2 2 2 2 2 (lpm) de Q (pulg) (m/seg) (Kg/cm ) (m) . (m) (m) (Kg/cm ) (Kg/cm ) (Kg/cm ) (Kg/cm ) (Kg/cm 2) 19.123 19.12 3/4 0.9 0.58 3.24 2.2 5.44 0.03155 0.309 0.277 0.397 17.605 17.6 3/4 0.8 0.5 0.6 1.4 2 0.01 -0.01 0.387 14.04 16.8 3/4 0.7 0.45 1.25 1.4 2.65 0.01193 0.095 -0.107 0.28 13.65 16.8 3/4 0.7 0.45 0.94 1.4 2.34 0.01053 -0.011 0.376 16.8 16.8 3/4 0.7 0.45 0.91 2.8 3.71 0.0167 -0.017 0.359 8.4 8.4 1/2 0.75 0.8 0.98 0.7 1.68 0.01344 -0.013 0.346 8.526 8.53 3/4 0.4 0.15 1.1 1.4 2.5 0.00375 -0.004 0.393 5.88 5.88 1/2 0.6 0.47 1.09 2.9 3.99 0.01875 0.109 -0.128 0.265 6.3 6.3 3/4 0.3 0.1 0.65 1.4 2.05 0.00205 -0.002 0.391 3.6 3.6 1/2 0.4 0.2 0.95 0.7 1.65 0.0033 0.095 0.092 0.483 2.7 2.7 1/2 0.28 0.13 1.37 1.4 2.77 0.0036 0.05 0.046 0.437 14.04 13.65 16.8 8.4 8.58 5.88 2.7 16.8 16.8 16.8 8.4 8.58 5.88 2.7 3/4 3/4 3/4 1/2 3/4 1/2 1/2 0.7 0.7 0.7 0.75 0.4 0.6 0.28 0.45 0.45 0.45 0.8 0.15 0.47 0.13 1.15 1.09 1.31 0.78 1.15 0.99 2.32 2.8 1.4 2.8 0.7 1.4 2.9 1.4 3.95 2.49 4.11 1.48 2.55 3.89 3.72 0.01778 0.01121 0.0185 0.01184 0.00383 0.01828 0.00484 0.085 0.067 -0.011 -0.018 -0.012 -0.004 -0.117 0.045 0.347 0.336 0.318 0.306 0.343 0.226 0.388

RED A. CALIENTE

RED AGUA FRA

0.099 0.05

99

Con el fin de verificar los rangos de operacin y establecer con claridad cual es el procedimiento que se acerca en mayor grado a lo proyectado, se realiza el clculo del sistema utilizando la frmula de Manning, considerando los gastos obtenidos por cada uno de los mtodos, as como las longitudes equivalentes calculadas, analizndose la red por los tres mtodos expuestos. Para llevar a cabo lo anterior se utiliza la frmula de Manning: H f = K L Q2 Donde: Hf K L Q son las prdidas de carga por friccin en metros es un coeficiente adimensional que depende del material y del dimetro del tubo es la longitud de la tubera en metros es el gasto que circula por el tubo medido en m3/segundo depende tambin del coeficiente de rugosidad del

El coeficiente adimensional K expresin. 10.2936 n 2 D


16 3

material, as como del dimetro del mismo, calculndose ste con la siguiente

K=

Considerando que la tubera a usar vara entre 1 y pulgadas de dimetro y que es de cobre tipo M, se usa el valor de n = 0.009, por lo que los valores de K para esos dimetros son: Tubo de Tubo de Tubo de 1 Tubo de 1 K = 10816,808.03 K = 1244,359.14 K= K= 268,290.82 81,611.70

100

Tubo de 1 Tubo de 2

K= K=

30,864.02 6,654.46

Por otra parte, la velocidad de circulacin del agua en la tubera se calcula con la ecuacin de continuidad. Q=V.A V=Q/A Donde: Q = gasto que circula medido en m3/segundo V = velocidad de circulacin en m/segundo A = rea de la tubera en m2 Las reas para las tuberas consideradas son: Tubo de Tubo de Tubo de 1 Tubo de 1 Tubo de 1 Tubo de 2 A = 0.0001266 m2 A = 0.0002850 m2 A = 0.0005066 m2 A = 0.0007916 m2 A = 0.0011400 m2 A = 0.0020268 m2 despejando a V queda:

Dado que en los clculos anteriores se obtuvieron los gastos, longitudes equivalentes y dimetros de tuberas, se utilizarn los mismos para el clculo usando la frmula de Manning

101

CLCULO DE RED CON PARMETROS DE HUNTER UTILIZANDO LA FRMULA DE MANNING Presin en A= 0.12 Kg/cm

Q Tramo (lpm) A-B 50 B-C 40 C-D 28 C-E 22 E-F 20 F-G 20 B-H 21 H-I 20 H-J 20 J-K 20 J-L 20 M-N N-O O-P P-Q N-R R-I R-S 28 22 20 20 20 20 20

V Q2 (m 3/seg) 2 (pulg) Area (m 2) (m/seg) 0.0000006944 1 1/4 0.000792 1.05 0.0000004444 1 0.000507 1.32 0.0000002178 3/4 0.000285 1.64 0.0000001344 3/4 0.000285 1.29 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001225 3/4 0.000285 1.23 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000002178 0.0000001344 0.0000001111 0.0000001111 0.0000001111 0.0000001111 0.0000001111 3/4 3/4 3/4 3/4 3/4 3/4 3/4 0.000285 0.000285 0.000285 0.000285 0.000285 0.000285 0.000285 1.64 1.29 1.17 1.17 1.17 1.17 1.17

Carga Carga Long. Perd. estat. (-) estat. (+) Presin equiv. Perd. (m) K (m) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) 6.49 81611.7 0.368 0.0368 0.309 0.392 2.1 268290.82 0.25 0.025 0.367 2.75 1244359.14 0.745 0.0745 0.095 0.197 2.14 1244359.14 0.358 0.0358 0.331 3.61 1244359.14 0.499 0.0499 0.281 1.73 1244359.14 0.239 0.0239 0.257 2.3 1244359.14 0.351 0.0351 0.357 3.94 1244359.14 0.545 0.0545 0.109 0.193 1.85 1244359.14 0.256 0.0256 0.331 1.7 1244359.14 0.235 0.0235 0.095 0.402 2.87 1244359.14 0.397 0.0397 0.05 0.341 3.85 2.29 4.01 1.53 2.35 3.84 3.82 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 1.043 0.383 0.554 0.212 0.325 0.531 0.528 0.1043 0.0383 0.0554 0.0212 0.0325 0.0531 0.0528 0.085 0.178 0.14 0.085 0.064 0.146 -0.006 0.143

RED A. CALIENTE

RED AGUA FRA

0.099 0.05

102

CLCULO DE RED CON PARMETROS DE PREZ CARMONA UTILIZANDO LA FRMULA DE MANNING Presin en A= 0.12 Kg/cm
2

Q Tramo (lpm) A-B 20 B-C 20 C-D 20 C-E 20 E-F 20 F-G 20 B-H 20 H-I 20 H-J 20 J-K 20 J-L 20 M-N N-O O-P P-Q N-R R-I R-S 20 20 20 20 20 20 20

V Q2 (m 3/seg) 2 (pulg) Area (m 2) (m/seg) 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 3/4 0.000285 1.17 0.0000001111 0.0000001111 0.0000001111 0.0000001111 0.0000001111 0.0000001111 0.0000001111 3/4 3/4 3/4 3/4 3/4 3/4 3/4 0.000285 0.000285 0.000285 0.000285 0.000285 0.000285 0.000285 1.17 1.17 1.17 1.17 1.17 1.17 1.17

Long. equiv. (m) 5.44 2 2.65 2.34 3.71 1.68 2.5 3.99 2.05 1.65 2.77 3.95 2.49 4.11 1.48 2.55 3.89 3.72

Perd. K (m) 1244359.14 0.752 1244359.14 0.277 1244359.14 0.366 1244359.14 0.324 1244359.14 0.513 1244359.14 0.232 1244359.14 0.346 1244359.14 0.552 1244359.14 0.283 1244359.14 0.228 1244359.14 0.383 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 1244359.14 0.546 0.344 0.568 0.205 0.353 0.538 0.514

Carga Carga Perd. estat. (-) estat. (+) Presin (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) 0.0752 0.309 0.354 0.0277 0.326 0.0366 0.095 0.194 0.0324 0.294 0.0513 0.243 0.0232 0.22 0.0346 0.319 0.0552 0.109 0.155 0.0283 0.291 0.0228 0.095 0.363 0.0383 0.05 0.303 0.0546 0.0344 0.0568 0.0205 0.0353 0.0538 0.0514 0.085 0.224 0.19 0.133 0.113 0.189 0.036 0.188

RED A. CALIENTE

RED AGUA FRA

0.099 0.05

103

CLCULO DE RED CON PARMETROS DE MTODO PROPUESTO EN LA INVESTIGACIN UTILIZANDO LA FRMULA DE MANNING

Presin en A= 0.12 Kg/cm

Q ajustado Tramo (lpm) A-B 19.12 B-C 17.6 C-D 16.8 C-E 16.8 E-F 16.8 F-G 8.4 B-H 8.53 H-I 5.88 H-J 6.3 J-K 3.6 J-L 2.7 M-N N-O O-P P-Q N-R R-I R-S 16.8 16.8 16.8 8.4 8.58 5.88 2.7

Q2 (m 3/seg) 2 0.0000001515 0.0000000860 0.0000000784 0.0000000784 0.0000000784 0.0000000196 0.0000000202 0.0000000096 0.0000000110 0.0000000036 0.0000000020 0.0000000784 0.0000000784 0.0000000784 0.0000000196 0.0000000204 0.0000000096 0.0000000020

Carga Carga Long. estat. (-) estat. (+) Presin V equiv. Perd. Perd. (pulg) Area (m 2) (m/seg) (m) K (m) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) (Kg/cm 2) 3/4 0.000285 1.12 5.44 1244359.14 0.687 0.0687 0.309 0.360 3/4 0.000285 1.03 2 1244359.14 0.214 0.0214 0.339 3/4 0.000285 0.98 2.65 1244359.14 0.259 0.0259 0.095 0.218 3/4 0.000285 0.98 2.34 1244359.14 0.228 0.0228 0.376 3/4 0.000285 0.98 3.71 1244359.14 0.362 0.0362 0.340 1/2 0.000127 1.11 1.68 10816808 0.356 0.0356 0.304 3/4 0.000285 0.5 2.5 1244359.14 0.063 0.0063 0.354 1/2 0.000127 0.77 3.99 10816808 0.414 0.0414 0.109 0.204 3/4 0.000285 0.37 2.05 1244359.14 0.028 0.0028 0.351 1/2 0.000127 0.47 1.65 10816808 0.064 0.0064 0.095 0.440 1/2 0.000127 0.36 2.77 10816808 0.061 0.0061 0.05 0.395 3/4 3/4 3/4 1/2 3/4 1/2 1/2 0.000285 0.000285 0.000285 0.000127 0.000285 0.000127 0.000127 0.98 0.98 0.98 1.11 0.5 0.77 0.36 3.95 2.49 4.11 1.48 2.55 3.89 3.72 1244359.14 1244359.14 1244359.14 10816808 1244359.14 10816808 10816808 0.385 0.243 0.401 0.314 0.065 0.404 0.081 0.0385 0.0243 0.0401 0.0314 0.0065 0.0404 0.0081 0.085 0.264 0.240 0.200 0.169 0.258 0.119 0.300

RED A. CALIENTE

RED AGUA FRA

0.099 0.05

104

4.4

AFORO A manera de comparativa, se establece un procedimiento para ver si los

gastos propuestos coinciden con los gastos reales, debindose realizar un aforo en la instalacin, para lo cual se propone lo siguiente: 1.- El nivel del tinaco se verifica que est a su mximo nivel para brindar la carga esttica que se supone en el anlisis de la red. 2.- Se aforan cada una de las salidas de los muebles instalados, primero por separado trabajando individualmente y despus en forma combinada, esto es, abriendo las dos vlvulas al mismo tiempo. 3.- Se retiran de la vlvula de salida el aditamento que contienen, siendo este aditamento el filtro, ello con la finalidad de evitar obstrucciones que repercutan en el aforo. 4.- Se toman la lectura de la temperatura ambiente, dentro y fuera de la edificacin, as como el mes, da y hora en que se lleva a cabo el aforo. 5.- Se utiliza un matraz de vidrio de capacidad de un litro para recolectar el agua en el proceso de aforo. 6.- Se utiliza un cronmetro marca Casio modelo DBX-112 con aproximacin de centsimas de segundo. 7.- Se realiza el aforo con dos personas, una que maneje el cronmetro y otra que realice la apertura y cierre de las vlvulas al llenar el matraz.

105

8.- El llenado del matraz se realiza primero abriendo la vlvula a aforar y se introduce el matraz al mismo tiempo que inicia a correr el tiempo, debindose retirar el matraz y detener el cronmetro al tiempo que el agua alcance la marca de un litro. 9.- Se anotan las lecturas correspondientes en una bitcora, realizndose el proceso de aforo y lecturas por cinco ocasiones, y al final se toman el tiempo medio de stas. 10.- Se tabulan los resultados obtenidos.

106

RESULTADOS

Siendo las 11:30 horas del da 11 de septiembre de 2004, se procede a realizar los aforos, tenindose una temperatura al exterior de 22o C y en el interior de la vivienda de 19o. Se verifica el nivel mximo del tinaco y se retiran los filtros de las vlvulas que lo contienen. Las lecturas obtenidas son anotadas en una bitcora con el fin de ordenarlas; el aforo es realizado por dos personas, una que abre las vlvulas respectivas y llena el depsito y otra que opera el cronmetro y anota los tiempos de llenado.

5.1

COMPARATIVO DE CLCULO Y AFOROS Siendo las 12:55 horas del da mencionado en el prrafo anterior, se termina

de realizar el aforo, obtenindose la informacin respectiva, la cual se ordena para presentarla. Las siguientes tablas contienen las lecturas del tiempo de llenado del matraz del aforo, aclarando que el sanitario debido a que utiliza solamente agua fra, no se tiene lectura de agua caliente y que dentro de la propuesta de agua fra, se us el cien por ciento del caudal que utiliza.

AFORO DE AGUA FRA Lecturas en seg. Mueble 1a Lec 2a Lec 3a Lec 4a Lec WC 25.87 25.90 25.86 25.91 Lavabo 15.15 14.93 14.92 15.10 Regadera 5.50 5.52 5.40 5.51 Fregadero 15.20 15.15 15.21 15.30 Lavadero 4.99 5.01 5.01 5.00 Lavadora 7.50 7.45 7.43 7.48

5a Lec 25.91 14.92 5.59 15.60 4.99 7.65

Suma 129.45 75.02 27.52 76.46 25.00 37.51

Promedio 25.89 15.00 5.50 15.29 5.00 7.50

Tab. 13 Lecturas de aforo en salidas de agua fra

107

AFORO DE AGUA CALIENTE Mueble 1 Lec 2 Lec WC Lavabo 18.33 18.10 Regadera 5.63 5.67 Fregadero 16.02 16.30 Lavadero 5.01 5.00 Lavadora 7.66 7.62

Lecturas en Seg. 3 Lec 4 Lec 5 Lec 18.21 5.71 16.70 4.98 7.67 18.12 5.69 16.11 5.01 7.66 18.15 5.61 16.03 5.01 7.64

Suma 90.91 28.31 81.16 25.01 38.25

Promedio 18.18 5.66 16.23 5.00 7.65

Tab. 14 Lecturas de aforo en salidas de agua caliente

AFORO COMBINADO Mueble 1a Lec WC Lavabo 13.07 Regadera 4.99 Fregadero 14.76 Lavadero 4.69 Lavadora 7.26

Lecturas en seg. 2a Lec 3a Lec 4a Lec 13.05 4.98 14.91 4.72 7.28 13.06 4.99 15.01 4.81 7.31 13.03 4.51 14.78 4.81 7.16

5a Lec 13.01 5.52 15.02 4.75 7.14

Suma 65.22 24.99 74.48 23.78 36.15

Promedio 13.04 5.00 14.90 4.76 7.23

Tab. 15

Lecturas de aforo en salidas combinadas

Con el fin de establecer una correlacin entre los parmetros utilizados en los clculos efectuados para el dimensionamiento de la red propuesta y los obtenidos en la realidad, se presenta a continuacin la informacin en forma comparativa. La tabla siguiente muestra los gastos de proyecto (3/4 del establecido cuando usan agua fra y caliente) y los obtenidos en los aforos.

COMPARATIVO DE CAUDALES CAUDAL EN LTS/MIN HUNTER Y PROPUESTO PREZ C. AFORO EN LTS/MIN A. CALIENTE COMBINADO

MUEBLE

A. FRIA

108

WC Lavabo Regadera Fregadero Lavadero Lavadora

20.00 15.00 15.00 15.00 15.00 15.00 Tab. 16

3.60 2.70 5.85 8.55 2.70 8.55

3.86 3.30 10.90 3.92 12.00 8.00

0.00 4.60 10.60 3.70 12.00 7.80

3.86 4.60 12.00 4.03 13.20 8.30

Tabla comparativa de gastos de proyecto y aforo

Como se observa en el aforo, los gastos medidos en el sanitario, lavabo, fregadero y lavadora se encuentran dentro de un rango cercano a lo proyectado de acuerdo al mtodo propuesto en la investigacin; no as el del lavadero y regadero, los cuales son mayores a los de proyecto. En el lavadero se entiende que es posible que debido a que se encuentra cercano a la bajada principal, la carga no est demasiado afectada por perdidas de friccin y ello repercute en un mayor gasto; sin embargo, la regadera es un aparato que debera obtenerse un gasto menor al medido, aclarando tambin que an y cuando se tienen instaladas vlvulas de esfera, es posible que debido a ello las prdidas por friccin sean menores a las cuantificadas. Otro mueble que se encuentra con un caudal diferente al proyectado es el fregadero, el cual el gasto medido es significativamente menor al establecido para el clculo; se deduce tambin que el mismo resulta menor quiz debido al tipo de mezcladora instalada, ya que se trata de una vlvula de un solo mbolo y los tubos que tiene de fbrica para instalar los alimentadores son tubos de 1/4 de dimetro, los cuales ofrecen una mayor prdida por friccin y por lo mismo, el gasto que entra y sale de la vlvula es menor al proyectado. A continuacin se presenta un grfico en el que se puede observar las diferencias significativas que presenta el aforo realizado contra los caudales propuestos en los clculos efectuados.

109

GRAFICO COMPARATIVO DE CAUDALES


25.00 20.00
CAUDALES
HUNTER Y PREZ C.

15.00 10.00 5.00 0.00


WC

PROPUESTO A. FRA A. CALIENTE COMBINADO

Lavabo

Lavadero

MUEBLES

Fig. 14

Grfico de comparativo de caudales

Se asienta tambin que los caudales propuestos en la investigacin son parmetros propuestos por Prez Carmona para cada aparato en particular; sin embargo cuando se manejan unidades de consumo estos caudales difieren en gran medida, ya que al utilizar el grfico del Dr. Hunter (Fig. 10), ste inicia con 5 unidades de consumo que equivalen a 20 litros/minuto, lo que hace que las tuberas as dimensionadas resulten con dimetros mayores a los que se obtienen si se calcula con los caudales que cada aparato requiere.

5.2

OTRAS CONSIDERACIONES A continuacin se presenta un grfico que es parte del recibo de cobro

mensual de la empresa AGSAL, el cual contiene la informacin de los consumos mensuales durante el 2004 en la vivienda estudiada, en el cual se observa que el promedio diario del consumo es de 0.36 m3, lo que equivale a un promedio mensual de 10.8 m3 en la vivienda analizada. 110

Fregadero

Regadera

Lavadora

Fig. 15

Copia de recibo de agua

Como dato extraordinario, se asienta que la vivienda analizada cuenta tambin con un equipo central de aire lavado tipo Master Cool modelo AP017994, el cual en los tiempos de verano ocasiona un consumo extra de agua como se observa en el recibo correspondiente. Los consumos por habitante y por da se observa en el recibo que son menores a los que se manejan comnmente, mismos que oscilan entre 200 y 250 litros por habitante y por da, siendo que en la realidad con el sistema diseado, este consumo es de 120 litros por habitante y por da, con lo cual, se demuestra que una vivienda puede funcionar perfectamente con una menor dotacin por habitante y por da, lo cual se traduce en menores costos por la instalacin, por el servicio y lo ms importante, se evita el dispendio de agua, y tambin, contribuimos a la conservacin del vital lquido para futuras generaciones.

111

VI

CONCLUSIONES

6.1

INTERROGANTE DE LA INVESTIGACIN Es posible adecuar las normas y mtodos de diseo de instalaciones

interiores que existen en el mundo a las necesidades de Saltillo, Coah. Mxico? La presente investigacin ha tenido por objeto el obtener una normativa sobre instalaciones interiores, basando en las normativas existentes en diversas partes del mundo; sin embargo, se encontr que las normativas existentes si bien es cierto en algunas de ellas se encuentran datos o parmetros que deben tomarse en cuenta para el diseo, tambin es cierto que no se pueden adaptar a la ciudad de Saltillo, Coah. Mxico. Con respecto a los mtodos que se utilizan, puede observarse que es uno solo y que a pesar de tener variantes en el proceso de clculo, ste no responde a las expectativas esperadas, ni toma en cuenta la limitante del recurso agua, por lo cual, es menester sealar que debe establecerse un mtodo propio para el diseo de instalaciones interiores, el cual debe contener los parmetros que se asientan en la propuesta realizada en el presente documento.

6.2

PROPUESTA Se ha cumplido el propsito de contar con un marco normativo en cuanto a

instalaciones interiores, toda vez que de la investigacin realizada se han obtenido parmetros de diseo y un criterio especfico sobre como deben ser diseadas las redes interiores de agua en las viviendas de la ciudad de Saltillo, Coah.

112

6.3

OBJETIVO Estando asentada la ciudad de Saltillo sobre una zona donde el agua es

escasa, es menester contar con un reglamento de diseo de redes interiores adecuado a nuestro medio, el cual garantice de una manera ptima la operacin del sistema, toda vez que permita disear stas con parmetros propios y confiables. Se ha cumplido el propsito de establecer parmetros para normar el diseo de instalaciones interiores, toda vez que a travs de los resultados obtenidos confrontados con la realidad de la operacin del sistema propuesto, se ha llegado a establecer que stos deben ser tomados en cuenta por las autoridades competentes para establecer una reglamentacin sobre el particular. La propuesta presentada, no pretende ser una normativa legal, sino son datos que a juicio del sustentante, deben contener la legislacin que pudieran realizar las autoridades del Ayuntamiento de Saltillo y la Cmara de Diputados locales, lo que permitira que la Direccin de Desarrollo Urbano del Municipio de Saltillo, contara con una norma que obligue a los constructores a ofrecer las mejores opciones de confort sobre el recurso agua a los ocupantes de las viviendas. Esta propuesta de norma, permitir que no solo se garantice la operacin eficiente de las instalaciones interiores, sino que tambin permitir una mejor administracin del agua en la ciudad y tambin, ayudar a que las futuras generaciones de saltillenses puedan contar con una vivienda confortable y disponer del recurso agua al menos con un 40 % ms en tiempo del que las instancias que manejan este vital lquido tienen contemplado actualmente.

6.4

JUSTIFICACIN La ciudad de Saltillo, Coah. se ubica en un rea semidesrtica, donde el recurso

agua es escaso, por lo cual, se presenta a continuacin la informacin pertinente que justifica por s misma la presente investigacin.

113

El Censo General de Poblacin y Vivienda realizado por el Instituto Nacional de Geografa y Estadstica para el Estado de Coahuila y sus Municipios (2000), asienta que el nmero total de viviendas del tipo casa habitacin es de 121,063 como se muestra en la tabla siguiente.

05 05004 05011 05024 05027 05030

XII CENSO GENERAL DE POBLACIN Y VIVIENDA 2000 Total de Total de viviendas viviendas habitada tipo casa habitadas independiente 2000 2000 Coahuila de 544322 506833 Zaragoza Arteaga 4595 4083 General 2668 2604 Cepeda Parras 9865 9511 Ramos 9421 8446 Arizpe Saltillo 132845 121063
Tab. 17 Censo de Vivienda de INEGI 2000

Por otra parte, la Direccin de Catastro Municipal de Saltillo (2005) tiene registrados los datos de viviendas que se muestran en la tabla siguiente; como puede observarse difieren en gran medida por los proporcionados por INEGI, sin embargo, los datos de Catastro fueron proporcionados por el rea que se encarga de la Recaudacin de Rentas Municipal, por lo tanto, para realizar un anlisis de costos y caudales, deben ser datos reales, por lo que se toman stos por estar actualizados y de mayor confianza.

TIPO DE VIVIENDA

NMERO

ACUMULADO

PORCIENTO

PORC. ACUM.

114

Diversas Zona Suburbana Popular Inters Social Bsica Inters Social Actual Residencial Media Residencial de 1 Residencial de lujo SUMAS
Tab. 18

9,241 68,514 18,290 50,555 39,616 12,952 12,952 212,120

9,241 77,755 96,045 146,600 186,216 199,168 199,168.00

4.36 32.30 8.62 23.83 18.68 6.11 6.11 100.00

4.36 36.66 45.28 69.11 87.79 93.89 93.89

Censo de vivienda Catastro Municipal 2005

Si se considera una media de 3 personas por vivienda, el nmero total de habitantes sera 597,504 personas, para lo cual solo se requerira dotar a la ciudad de 829.87 litros por segundo, los cuales comparados con la informacin proporcionada por AGASAL (1,400 litros por segundo), arroja que se pueden ahorrar 570.13 litros por segundo, los cuales pueden ser suficientes para abastecer 136,831 viviendas adicionales; por otra parte, los costos por este servicio disminuiran en un 40.72 %. Este gasto ahorrado traducido en dinero (sin impuesto), arroja la cantidad de $ 1.68 cada segundo, lo que hace un monto horario de $ 6,048.00, un importe diario de $ 145,152.00 y un monto anual de $ 52,980,480.00 Se asienta tambin que, el resto de las viviendas que no encuadran dentro de la investigacin, son viviendas del tipo residencial de lujo (12,952), en las cuales y debido a la economa de sus propietarios, cuentan con sistemas hidroneumticos para abastecer los diferentes aparatos sanitarios, sin embargo, tambin es posible que estas puedan ser calculadas para ser abastecidas por medio de tinacos, considerando en este clculo un mayor volumen de agua, debido a que este tipo de viviendas cuentan con amplios jardines y espacios mayores que atender. Por otra parte, es menester sealar que de acuerdo a la investigacin realizada en la ciudad de Saltillo, Coah. por Salazar de Len S. y Silva B. Ma. C. (2000) de la Facultad de Sistemas de la U. A. de C., se ha podido constatar que el proporcionar un mayor caudal a las viviendas es contraproducente, ya que las personas al tener una mayor cantidad de agua, tienden al dispendio, lo que se traduce en derroches de 115

energa, dinero y lo mas grave, del abatimiento acelerado de las fuentes de aprovisionamiento del agua, lo que en un futuro cercano provocara la escasez de ste vital lquido, por lo cual, se hace necesario que la dotacin de agua que se brinde a los pobladores, sea adecuada a sus necesidades y no mayor a ella.

VII

DISCUSIN

A continuacin, se presenta una crtica sobre la documentacin que fue utilizada en la investigacin, la cual es la siguiente:

116

MTODO

HUNTER

PARA

INSTALACIONES

INTERIORES

INSTALACIONES EN LOS EDIFICIOS 1999) El mtodo del Dr. Hunter est diseado para las costumbres, consumos y tipos de muebles que se utilizan en la Unin Americana, mismos que difieren en gran medida de lo que se requiere y demanda en nuestra poblacin de Saltillo, por lo cual, y en funcin de lo anterior, se establece que este mtodo no es adecuado para ser utilizado en el clculo de nuestros sistemas de redes interiores, ya que al considerar estos parmetros, las redes as dimensionadas, se obtienen dimetros de tuberas por dems exagerados para los requerimientos de nuestra poblacin, repercutiendo ello en altos costos por la instalacin; adems, los consumos de agua en las viviendas que se disean con este mtodo, repercuten tambin en la economa familiar y lo mas grave, en el abatimiento de los acuferos que suministran agua a la poblacin.

MTODO PROPUESTO POR ING. RAFAEL PREZ CARMONA EN SU LIBRO EL AGUA (TOMO I 1998) El mtodo del Ing. Prez Carmona, si bien brinda resultados mas cercanos acorde a lo requerido por nuestra poblacin, es tambin cierto que al tomar las unidades de consumo como indica el Dr. Hunter, los resultados an y cuando se utiliza el coeficiente K de simultaneidad, difieren en las presiones y caudales obtenidos por la frmula de Manning, sin embargo, resulta mas adecuado si se toman los caudales proporcionados por l en la Tabla 6.

MTODO PROPUESTO POR FREDERICK S. MERRITT MANUAL DEL INGENIERO CIVIL VOLUMEN II 1985)

117

Este mtodo no brinda ninguna informacin sobre cmo deben calcularse las instalaciones interiores, sin embargo se asienta que al igual que el mtodo del Dr. Hunter, fueron diseados para satisfacer las necesidades de la poblacin en los Estados Unidos de Amrica y no a nuestra poblacin, por lo cual, tampoco los parmetros que indica son adecuados para nuestro medio.

NORMAS TCNICAS PARA INSTALACIONES DE SUMINISTRO DE

AGUA

VIGENTES EN LAS PROVINCIAS DE BARCELONA, MLAGA, SEVILLA, VALENCIA, ALICANTE, CRDOBA, NAVARRA, CASTELLN, GERONA, VIZCAYA Y LA CORUA EN ESPAA. (GOBIERNO DE ESPAA-1975) La normatividad espaola establece claramente los gastos a considerar en funcin del tipo de edificacin, as como tambin los dimetros mnimos, teniendo su normativa informacin clara y precisa sobre las instalaciones interiores, pero no establece la forma en que deba realizarse el clculo, el cual se deduce por los gastos que menciona que el clculo deba realizarse por el mtodo de Hunter adecuado a sus necesidades, ya que en ningn caso se mencionan unidades de consumo que permitan suponer la utilizacin del mtodo americano tal y como el autor del mtodo lo propone; por otra parte, la normativa est diseada para un suministro de agua a presin, esto es, considerando un sistema de bombeo y no de tinaco como se utiliza en nuestro medio, por lo cual, no es viable la utilizacin de esta normativa en el rea de Saltillo, a excepcin de que los caudales que se indican para los diferentes aparatos, no difieren mayormente de los propuestos en la investigacin presente.

118

NORMATIVA PARA LA PRESTACIN DE LOS SERVICIOS PBLICOS DOMICILIARIOS DE ACUEDUCTO Y ALCANTARILLADO EN LA REPBLICA DE COLOMBIA. (GOBIERNO DE COLOMBIA 2000)

Esta normativa no indica en absoluto la metodologa a seguir, solamente indica que las instalaciones debern ajustarse a las normas y especificaciones previstas en el Reglamento Tcnico del Sector de Agua Potable y Saneamiento Bsico, por lo cual, tampoco es posible adecuarlo a nuestra entidad. Resulta por dems extrao que siendo el Ing. Rafael Prez Carmona un profesional colombiano que trata ampliamente sobre en tema en su libro, no exista en su pas una normativa sobre ella.

REGLAMENTO PARA LA PRESTACIN DE SERVICIOS DE AGUA POTABLE Y ALCANTARILLADO SANITARIO EN ZONAS CONCESIBLES DE BOLIVIA. (GOBIERNO DE BOLIVIA 2000) Este Reglamento tampoco indica la forma del diseo de las instalaciones interiores, sin embargo, dentro de sus apartados indica que deber anexarse copia del plano sanitario de la red interna, tanto de suministro de agua potable como de las instalaciones de alcantarillado, firmado por un profesional del sector, debidamente inscrito en la Sociedad de Ingenieros de Bolivia, quin aplicar las normas vigentes respectivas, mismas que no establecen parmetros de diseo y clculo. As tambin, la Normativa Boliviana marca en el Artculo 25, que el dimensionamiento y clculos hidrulicos se realizarn con estricto apego al Reglamento Tcnico de Diseo para Sistemas de Agua Potable y para Alcantarillado; sin embargo, dichos reglamentos se refieren a sistemas de abasto y alcantarillado urbano y no precisamente a instalaciones interiores, por lo tanto, no es posible adecuarlo a nuestro medio.

119

6
CHILE

TEXTO DECRETO CON FUERZA DE LEY NO. 382-1989 MINISTERIO DE OBRAS PBLICAS, SUBSECRETARA DE OBRAS PBLICAS, REPBLICA DE

(GOBIERNO DE CHILE 2003) El documento no indica parmetros de diseo ni clculo, solamente establece las obligaciones de los usuarios, marcando en uno de sus apartados lo siguiente: El mantenimiento de las instalaciones interiores domiciliarias de agua potable y de alcantarillado es de exclusiva responsabilidad y cargo del propietario del inmueble. Por lo anterior, tampoco es adaptable a nuestra poblacin.

MARCO REGULADOR PARA LA PRESTACIN DE SERVICIOS PBLICOS DE AGUA POTABLE Y DESAGES CLOACALES EN LA PROVINCIA DE CRDOBA, ARGENTINA. (AYUNTAMIENTO DE CRDOBA, ARGENTINA 1994) El Marco Regulador de Crdoba, Argentina al igual que el de Chile, solamente establece la obligatoriedad del usuario, pero no contempla parmetros de clculo ni metodologa, solamente establece que el usuario es responsable de acondicionar las instalaciones interiores respetando las normas vigentes, as como del mantenimiento de stas. La Normativa Argentina presentada hace referencia al Artculo 59 como aquel que dicta las normas de caudal y presiones requeridas, sin embargo el documento estudiado solamente consta de 30 artculos, por lo cual no es posible ubicar en forma definida el artculo referido. Por lo anterior, no es aceptable adecuarlo a Saltillo, Coah.

REGLAMENTO DE PRESTACIN DE SERVICIOS DE AGUA POTABLE AREQUIPA S.A. - SEDAPAR S.A.

ALCANTARILLADO DEL SERVICIO DE AGUA POTABLE Y ALCANTARILLADO DE

120

(AYUNTAMIENTO DE AREQUIPA, PER 1998) Este Reglamento solamente indica la forma y calidad de la prestacin del servicio por parte del organismo responsable y tambin, indica que los usuarios tienen la responsabilidad de mantener el correcto funcionamiento de sus instalaciones interiores de agua y alcantarillado, hacer un uso racional de estos servicios y cumplir con su pago oportuno, por lo cual, no tiene establecido la forma de clculo ni los caudales y presiones dentro de las instalaciones interiores. Esta normativa no es adecuable a la ciudad de Saltillo, Coah.

REGLAMENTO DEL SERVICIO DE AGUA Y DRENAJE PARA EL DISTRITO FEDERAL, MXICO. (GOBIERNO DEL DISTRITO FEDERAL, MXICO 1997) El Reglamento del Distrito Federal si bien estable los caudales mximos que deben descargar algunos muebles sanitarios, no establece la forma de clculo ni las presiones recomendadas con que deban disearse las instalaciones, sin embargo, en el Artculo 16 indica que deber presentarse memoria de clculo de dichas instalaciones, por lo cual se deduce que el mtodo empleado en el diseo es a criterio del proyectista y no bajo normatividad alguna; esta normativa no ofrece ningn aporte a lo requerido en Saltillo, Coah.

11

REGLAMENTO PARA LAS CONSTRUCCIONES EN EL MUNICIPIO DE MONTERREY. (AYUNTAMIENTO DE MONTERREY, N. L. MXICO 2002) Este Reglamento si bien es cierto que brinda una informacin clara y precisa

sobre el procedimiento constructivo de las instalaciones interiores, as como los tipos de materiales a usar y que deben colocarse vlvulas individuales en los baos y

121

sanitarios, adems de la prueba hidrosttica a que debern someterse las instalaciones, tampoco brinda informacin sobre los caudales ni el mtodo a utilizar para hacer cumplir la eficiencia del servicio interior como lo marca en su Artculo 100 del Captulo XIII de Instalaciones, por lo cual no es aplicable a nuestra ciudad de Saltillo, Coah. a excepcin de algunas consideraciones constructivas.

12

LEY

PARA

LOS

SERVICIOS

DE

AGUA

POTABLE,

DRENAJE

ALCANTARILLADO EN LOS MUNICIPIOS DEL ESTADO DE COAHUILA DE ZARAGOZA. (GOBIERNO DEL ESTADO DE COAHUILA, MXICO 2001) La Ley para los Servicios de Agua Potable, Drenaje y Alcantarillado en los Municipios del Estado de Coahuila es una copia casi exacta del Reglamento de Servicio de Agua y Drenaje del Distrito Federal, y por consecuencia, no establece los criterios de diseo de redes interiores, inclusive, no especifica en lo absoluto los caudales de los aparatos, solamente indica el lugar donde debe instalarse el medidor.

13

LEY DE PRESTACIN DE LOS SERVICIOS DE AGUA POTABLE, DRENAJE Y ALCANTARILLADO DEL ESTADO DE TABASCO (GOBIERNO DEL ESTADO DE TABASCO, MXICO 1980) La Ley de Prestacin de los Servicios de Agua Potable, Drenaje y Alcantarillado del Estado de Tabasco, no brinda en sus apartados ninguna informacin sobre como deba realizarse el clculo de las instalaciones interiores, por lo cual, se entiende que se deja a criterio del proyectista la forma en que quiera realizarlo. En su Artculo 30 indica la forma en que debe ser abastecido el tinaco dentro de la edificacin, por lo que nos encontramos que el tipo de suministro a la vivienda es igual al utilizado en nuestra ciudad, sin embargo ante la falta de

122

informacin sobre el rea que nos ocupa, tampoco es posible la utilizacin o adecuacin de esta Ley a Saltillo, Coah.

VIII

PROPUESTA Y RECOMENDACIONES

123

Las Instalaciones Interiores son el conjunto de tuberas y accesorios que integran el sistema de distribucin de agua dentro de una edificacin, por lo cual, es vital que sean diseadas e instaladas en forma adecuada, ya que el confort de los ocupantes de la edificacin depende directamente de ellas, por lo tanto, se proponen las siguientes recomendaciones para que sean tomados en cuenta en la legislacin correspondiente.

DISEO Y PERMISOS: 1.- El diseo de las instalaciones interiores, debe ser efectuado por un profesional en la materia, el cual deber estar debidamente acreditado ante las instancias que otorgan los permisos de construccin. 2.- La construccin de la instalacin interior ser la que se indique en el proyecto y debern garantizar la eficiencia de la misma, as como la seguridad de la edificacin, trabajadores y usuarios, por lo cual, deber ejecutar la obra un instalador competente, supervisado por el profesional que efectu el diseo y los clculos. 3.- Las autoridades otorgantes del permiso de construccin, debern solicitar la memoria de clculo, planos de la edificacin e isometras del mismo.

SUMINISTRO: 4.- La compaa que suministra el servicio de agua (AGSAL), ser la encargada de solicitar se cumpla con sus normas en cuanto a la forma y ubicacin de la estructura que alojar el contador de agua, considerndose que inmediatamente despus de ste, inicia la instalacin interior y el mantenimiento de sta estar a cargo del usuario de la edificacin.

124

5.- El tramo de tubera en el que se instale el contador de agua, deber formar parte de una U para que en ese tramo se soporte el golpe de ariete. Las tuberas antes descritas al inicio de las redes debern contar con una vlvula de compuerta antes del medidor y una vlvula check despus del medidor.

DEPSITOS: 6.- Los depsitos para almacenamiento de agua (tinacos), debern instalarse en la parte mas alta de la edificacin y su nivel mnimo de agua deber estar por lo menos 2 metros arriba del nivel de la cebolleta de la regadera. 7.- Los depsitos sern preferentemente de plstico y con tapa que garantice un sellado efectivo; as como tambin debern contar con una vlvula con flotador para asegurar el llenado del mismo. 8.- Es recomendable que en el caso de viviendas que tengan un solo bao, el tinaco se ubique arriba de ste a fin de evitar recorridos grandes de tubera que ocasionen altas prdidas por friccin. 9.- En el caso de viviendas con dos o ms baos, se preferir ubicar el depsito en un rea equidistante de ellos, o en su defecto, colocarlo sobre el bao de mayor importancia en la edificacin. 10.- La capacidad del depsito (tinaco), ser la que resulte de multiplicar la dotacin por persona y por da por el nmero de ocupantes de la vivienda; se considera dentro de sta capacidad, el nmero de das transcurridos que deba abastecer. En el caso que la capacidad rebase los 1,100 litros, se deber instalar una cisterna, la cual contendr el 60 al 80 % del volumen necesario y un tinaco abastecido por bombeo que pueda contener del 40 al 20 % del volumen total calculado.

125

DOTACIN DE AGUA: 11.- La dotacin de agua se considerar para efectos de clculo de los depsitos a razn de 120 litros por habitante y por da para viviendas residenciales, salvo que dentro del proyecto se establezca alguna circunstancia en especial que justifique una mayor dotacin, en cuyo caso, las autoridades debern valorar la situacin.

TIPO DE TUBERAS: 12.- Las tuberas y accesorios para agua potable debern ser de cobre rgido, cloruro de polivinilo, fierro galvanizado o de otros materiales que resistan una presin de columna de agua igual o mayor de la presin que maneja la compaa que suministra el servicio, y adems, que satisfagan las normas de calidad establecidas por la Direccin General de Normas de la Secretara de Comercio y Fomento Industrial, mismas que son las normas estndares que actualmente rigen en el mercado.

PRUEBA HIDROSTTICA: 13.- Antes de tapar o recubrir cualquier instalacin hidrulica, deber someterse a una prueba de hermeticidad dejando la tubera a presin y con control de manmetro 24 horas por lo menos. 14.- La presin de prueba de la instalacin interior se efectuar a una presin constante de 3.00 Kg/cm2 (Norma Oficial Mexicana NOM-008-CNA-1988 Regaderas empleadas en Aseo Corporal a presin media), equivalente a 2.941 Bar. CAUDALES:

126

15.- Los caudales por aparato a utilizar en el dimensionamiento de la instalacin interior sern los siguientes (salvo casos especiales), considerando que cuando un aparato utilice solamente agua fra, se tomar el 100 % del caudal (wc), y cuando utilice agua fra y caliente, los caudales se tomarn al 75 % de dicho caudal.
Aparato WC de tanque bajo Regadera Lavabo Fregadero Lavadora Lavadero
Tab. 19

Gasto (lpm) 100% 75% 3.60 7.80 5.85 3.60 2.70 11.40 8.55 11.40 8.55 3.60 2.70

Gastos por aparato recomendados

DIMENSIONAMIENTO: 16.- El dimensionamiento de la red se deber realizar utilizando los caudales que cada aparato requiere y no las unidades de consumo (mtodo propuesto en la presente investigacin). 17.- Para el clculo de la red, se realizar un seccionamiento de sta, considerando desde la salida del depsito (tinaco) hasta el ltimo tramo de ella. Los seccionamientos se realizarn en todos aquellos puntos donde exista un nodo (tee) y donde se encuentre una salida. 18.- Para efectos de clculo, se deber considerar que cada tramo abastecer a los muebles que se localicen en el tramo siguiente (considerado de acuerdo al flujo del agua), el cual ser afectado por el coeficiente de simultaneidad correspondiente, el cual esta en funcin del nmero de salidas de los muebles por abastecer. 19.- Para el clculo de los gastos por tramo de la red, debern utilizarse los coeficientes de simultaneidad siguientes:

127

No. de Valor de No. de Valor salidas K salidas de K 1 1.00 9 0.35 2 1.00 10 0.33 3 0.70 11 0.32 4 0.57 12 0.30 5 0.50 13 0.29 6 0.45 14 0.28 7 0.40 15 0.26 8 0.37 16 0.25
Tab. 20

No. De Valor de salidas K 17 0.24 18 0.24 19 0.23 20 0.23 21 0.22 22 0.22 23 0.21 24 0.21

Coeficientes de simultaneidad para aparatos

20.- Para calcular las prdidas por accesorios de la red, se utilizar la siguiente tabla de equivalencias en tuberas rectas:

tubo en Pulg. 1 1 1 2 2 3 4 5 6 8 10 12 14

Codo 90 0.50 0.70 0.80 1.10 1.30 1.70 2.00 2.50 3.40 4.20 4.90 6.40 7.90 9.50 10.50

Codo 45 0.20 0.30 0.40 0.50 0.60 0.80 0.90 1.20 1.50 1.90 2.30 3.00 3.80 4.60 5.30

Tee giro 1.00 1.40 1.70 2.30 2.80 3.50 4.30 5.20 6.70 8.40 10.00 13.00 16.00 19.00 22.00

Tee de recto 0.30 0.40 0.50 0.70 0.90 1.10 1.30 1.60 2.10 2.70 3.40 4.30 5.50 6.10 7.50

Vlvula de compuerta 0.10 0.10 0.20 0.20 0.30 0.40 0.40 0.50 0.70 0.90 1.10 1.40 1.70 2.00 2.10

Vlvula de plato 4.90 6.70 8.20 11.30 13.40 17.40 21.00 26.00 34.00 43.00 51.00 67.00 85.00 102.00 120.00

Vlvula de ngulo 2.60 3.60 4.60 5.60 6.70 8.50 10.00 13.00 17.00 21.00 26.00 34.00 43.00 51.00 60.00

Tab. 21

Tabla de equivalencias de accesorios en tubo recto

21.- Para efectos de diseo de la instalacin interior, pueden utilizarse los grficos del Dr. Hunter para encontrar los dimetros de tuberas, as como las prdidas que ocasionan stos en tramos de 100 metros de tubera recta. (Figs. 11 y 12) pginas 24 y 25 del presente documento.

128

22.- Es recomendable tambin realizar el clculo utilizando la frmula de Manning, para lo cual, al presentar la memoria de clculo ante las autoridades respectivas, se deber indicar el mtodo establecido. 23.- Se establece que se deber respetar que el dimetro mnimo de tubera dentro de una instalacin interior domiciliaria, no deber ser menor de 3/4 y que el dimetro mnimo para suministro a un solo aparato ser de tubera de 24.- Se recomienda tambin que el recorrido de la red sea ranurando muros a una altura de 0.55 metros sobre el nivel de piso terminado (altura de alimentacin del lavabo) y no por piso, ya que ello traera consigo un mayor recorrido de la red y por consiguiente mayores prdidas por friccin, adems de un mayor costo del sistema. As mismo, el suministro de agua al sanitario se propone que sea por muro, a una altura de 0.225 cm sobre el nivel del piso terminado y no por el piso como actualmente se realiza en las viviendas. 25.- En la bajada principal del depsito hacia el sistema, se deber instalar una vlvula que permita en caso de realizar una operacin, cerrar el sistema en su totalidad. ACCESORIOS: 26.- Deber contemplarse instalar al inicio de la bajada principal del tinaco, un jarro de aire, el cual ser del mismo dimetro de la bajada y su longitud ser cuando menos 0.30 metros arriba del nivel mximo del tinaco. CALENTADOR DE AGUA: 27.- La ubicacin del calentador de agua deber preferirse instalarlo en la bajada de la tubera y es recomendable que se localice lo mas cerca posible del bao por alimentar, cuidando que ste quede a la intemperie y nunca dentro de una habitacin.

129

28.- A la salida del agua caliente del calentador, se deber instalar tambin un jarro de aire y su longitud ser cuando menos 0.30 metros arriba del nivel mximo del tinaco. 29.- El clculo del calentador de agua se realizar tomando en consideracin el 50 % de la dotacin por persona y por da, la cual, multiplicada por el nmero de ocupantes de la vivienda, cantidad de la que se tomar establecer la capacidad del calentador. (Gay-Fawcett. 1999) APARATOS: 30.- Los sanitarios a instalar sern aquellos cuya capacidad de tanque bajo sea de 6 litros, no permitindose aquellos que sobrepasen esta capacidad. 31.- Las instalaciones hidrulicas de baos y sanitarios debern tener llaves de cierre individual. 32.- Las vlvulas mezcladoras debern preferirse las que sean del tipo globo. 33.- En la regadera se preferir el uso de cebolletas ahorradoras de agua y las del tipo aceleradoras de flujo, cuyo caudal no sobrepase los 10 litros por minuto.. 34.- Finalmente se recomienda que todo lo que se oponga a la presente investigacin, sea desechado. una 1/7 parte para

BIBLIOGRAFA
1 Ayuntamiento de Arequipa (1998)., Reglamento de Prestacin de Servicios de Agua Potable y Alcantarillado de SEDAR de Arequipa S. A., Publicacin Oficial de marzo., Per

130

Ayuntamiento de Crdoba (1994)., Marco Regulador para la Prestacin de Servicios Pblicos de Agua Potable y Desages Cloacales en la Provincia de Crdoba., Publicacin Oficial de marzo., Argentina

Ayuntamiento de Cuenca (1992)., Normas Generales, Captulo 3 de las Normas Urbansticas del Ayuntamiento de Cuenca., Publicacin de Orden del 18 de diciembre., Espaa 4 5 Ayuntamiento de Monterrey, N. L. (2002)., Reglamento Construcciones en el Municipio de Monterrey, N. L., Mxico para las

Comisin Nacional del Agua (2002)., Leyes, Normas y Recomendaciones para los Sistemas de Agua Potable., Publicacin Oficial de la Comisin Nacional del Agua., Mxico Cuellar Valds Pablo M. (1975)., Historia de la ciudad de Saltillo., Edit. Ayuntamiento de Saltillo, Coah., Mxico Departamento de Meteorologa (2002)., Informacin Estadstica Climatolgica en el Municipio de Saltillo, Coahuila., Edit. Universidad Autnoma Agraria Antonio Narro., Mxico Direccin de Catastro (2005)., Archivo de Departamento sobre Informacin de Viviendas en el Municipio de Saltillo, Coah., Mxico Directiva del Consejo (1988)., Higiene, Salud y Medio Ambiente, Documento Interpretativo Requisito Esencial Nmero 3., Publicacin de Orden del 21 de diciembre., Espaa Frederick S. Merritt (1985)., Manual del Ingeniero Civil., Edit. Mc Graw Hill., Mxico Gay.Fawcett.McGuinnes.Stein (1999)., Instalaciones en los Edificios., Edit. Gustavo Gili S. A., Espaa Gobierno de Chile (1989)., Decreto con Fuerza de Ley Nmero 382 de 1988 para Fijar la Ley General de Servicios Sanitarios., Diario Oficial del 21 de junio., Chile Gobierno de Colombia (2000)., Decreto Nmero 302 de 2000 Relativo a la Prestacin de Servicios Pblicos Domiciliarios de Acueducto y Alcantarillado., Publicacin Oficial del 25 de febrero., Colombia Gobierno de Espaa (1975)., Normas Bsicas para las Instalaciones Interiores de Suministro de Agua., Publicacin de Orden del 9 de diciembre., Espaa Gobierno del Distrito Federal (1997)., Reglamento del Servicio de Agua y Drenaje para el Distrito Federal., Peridico Oficial del 21 de octubre., Mxico 131

6 7

8 9

10 11 12

13 14 15

16

Gobierno del Estado de Coahuila (2001)., Ley para los Servicios de Agua Potable, Drenaje y Alcantarillado en los Municipios del Estado de Coahuila., Peridico Oficial del 2 de febrero., Mxico Gobierno del Estado de Tabasco (1980)., Ley de Prestacin de Servicios de Agua Potable y Alcantarillado del Estado de Tabasco., Peridico Oficial del 4 de septiembre., Mxico Gmez Anala (2002)., Instalaciones Sanitarias y Agua Potable en Argentina., Publicado por Arq. Anala Gmez., Argentina Instituto Nacional de Geografa y Estadstica (1988)., Anuario Estadstico del Estado de Coahuila Tomo I., Edit. Gobierno de Coahuila., Mxico Instituto Nacional de Geografa y Estadstica (1994)., Anuario Estadstico del Estado de Coahuila Tomo I., Edit. Gobierno de Coahuila., Mxico Instituto Nacional de Geografa y Estadstica (1990)., Coahuila, Resultados Definitivos Tomos I y II, Tabulados Bsicos XI del Censo General de Poblacin y Vivienda., Edit. Gobierno de Coahuila., Mxico Instituto Nacional de Geografa y Estadstica (1995)., Coahuila, Resultados Definitivos, Tabulados Bsicos, Conteo 95 de Poblacin y Vivienda., Edit. Gobierno de Coahuila., Mxico Instituto Nacional de Geografa y Estadstica (1998)., Cuaderno Estadstico Municipal., Edit. Ayuntamiento de Saltillo., Mxico Instituto Nacional de Geografa y Estadstica (2000)., Censo General de Poblacin y Vivienda de Coahuila y sus Municipios., Edit. INEGI., Mxico Inteltech S. A. de C. V. (2005)., Curso Bsico de Hidrulica Tecnologa Hidrulica., Inteltech, Tecnologa educativa., Mxico Joseph B. Franzini E. John Finnemore (1999)., Mecnica de Fludos., Edit. Mc Graw Hill., Espaa Ministerio de Obras Pblicas de Chile (2003)., Reglamento de Instalaciones Domiciliarias de Agua Potable y de Alcantarillado., Publicado por el Gobierno de la Repblica el 28 de enero., Chile Ministerio de Vivienda y Servicios Bsicos (2000)., Reglamento para la Prestacin de Servicios de Agua Potable y Alcantarillado Sanitario en Zonas Concesibles., Publicacin Oficial de octubre., Bolivia Prez Carmona Rafael (1998)., El Agua., Edit. Escala., Espaa 132

17

18 19 20 21

22

23 24 25 26 27

28

29

30

Salazar de Len Sonia J. y Silva B. Ma. Cristina (2000)., Educacin en el Consumo de Agua, una Visin Sistmica para el Caso Saltillo., Edit. Tesis de la Facultad de Sistemas de la U. A. de C., Mxico SEDAR de Arequipa S. A. (2001)., Gua de Instalaciones Tcnicas Hidrulicas., Publicacin a cargo de SEDAR., Per Servicio Informativo Municipal (2000)., Reglamento Tipo de Alcantarillado, Agua Potable y Saneamiento., Gobierno de la Repblica., Mxico Sotelo Avila Gilberto (1990)., Hidrulica General., Edit. Limusa Noriega S. A. de C. V., Mxico Surez Snchez Jos Mara (1994)., Historia y Geografa del Estado de Coahuila., Edit. Del Valle Crdamo., Mxico Trueba Coronel Samuel (1998)., Hidrulica., Edit. Compaa Editorial Continental S. A., Mxico Valds E. Ral A. (1984)., Meteorologa Climatolgica., Edit. Comisin Nacional del Agua., Mxico

31 32 33 34 35 36

133