Вы находитесь на странице: 1из 8

, 2013, 4, 1, .

18



539.1.074.88


 400
2013 . , . . , . .

29.03.2012 .


400

GEANT4. .

. , ,

. ,

3,

. .
7.94 107 13.73 ,

. ,

, .
:

400, ,

.
DOI: 10.1134/S2079562913010089


400

,
:

0 15

,
(

) [2].

, ,
.
4004000

. ,

,
1012 .

, ,

.
, ,

,
C4,

.


400


400

, ,

..,

,
,

, ,


,
,

[1].
1.


400



400
(. . 1) [1],

.
AC

AC

1 X
25 layers W0.04 X + Si(x,y) ( 0.1 )
1 Si

1100

1, 2
Si(x,y)
1 ()

3, 4
1 (3X)
4 Csl 0.75 X + Si(x,y) ( 0.5 )

3000

1100

2
BGO (21 Xo) 2.24 2.24 23 3 400 4

1200
500

800

4 10 120 2

400

2 ()

700

600

. 1.
400.



GEANT4 [3].

.
C4

, /
400
350
300
250
200
150
100
50
0
0.10
0.01
1.00
10.00
,
. 2. .

104 . ,


(100 )

C4 ,
GEANT4, . 2.
,

.
2.


(. 3)

,
80 80 ,

5 .
0.5 ,
.

2013



.
. 4 [4]


(n, ) . ,
(n, )
0.4 , 2500 ,

, (n, )

, .

1
.
,

,


,

.

0.01 9 . . 5

2.5 .

(

) 5 .

80 80 5
.
. 6.

0.005 0.01 0.05 . ,

. ,
. 6 ,

1% 2%

0.1%.



( 1, 2, 3,
4 ).

. 1.

C4
1

. 3. . 1

, 2 . 4
1.5 .

,
106
104
102
1
102
1010
105
1
,
. 4. (n, )
.


2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0

3 4 5 6 7 8 9 10
,

. 5.

1 ,

,

2013

.
,
0.0220
0.0210
0.0200
0.0190
0.0180
0.0170
0.0160
0.01 0.02 0.03 0.04 0.05 0.06
0
,

,
0.25
0.20
0.15
0.10
0.05
0
4 5 6 7 8 9 10 11 12 13 14 15
,

. 6.
.

. 7.
.


1% 2%
0.1%.


,
,
(n, ) ,

0.01 9 (. . 5),



2.5 , ,

. , ,
,
, , ,


.
. 7.

3.

15


20%.

3.1.
,

, ,

. (. 8, 9).

10B + n 7Li* + + 2310 (n, )
[5].

,
,
,
.

1 /2,

.
8
9

80 80 .
0.02 , 0.02 ,
3 ,

0.5 .

5 .

, .


(n, ) ,

1

(%)

.
: 2

).
: 3

).
: 4

).

1.9%
1.7%
1.6%
1.2%

2013

C4
Cd
B

C4

. 8.

. 4

1.5 .

. 9.

. 4
1.5 .

[5].

7Li* (478 )


50 ( 500 ).


. 2.
. 2

,
. 10 11 ( 4 5, )

. 3.
, . 3,

,
,

4 5 ,
2 3.
, 25

, ,
.

,
. 12.
,

+ ).

.
,

, 5%


10 80%. . 12

3.2. ,

,

, ,
5%

[6].

,
. 10, 11 12.

, ,
B
10 80%.

.
, ,
80 80 .

0.02 ,

3 ,
0.5 .

5 .

2 (. . 8)
3 (. . 9)
2013


(%)
31
21

C4
Cd

. 10.

,
. 4
1.5 .

C4

. 11.

. 4

1.5 .

C4


2

2

. 12. ,
.

1 .

3 . 7 .
2 .
. 13 . 14

2 .
,
,
.

. 6 ,
15%
, 24%
, .
3

4 (. . 10)
5 (. . 11)


(%)
11 1
12 1

, . 12 (
).

. 15.
. 16

80%.
,


. ,
,

, ,

7Li*,

34 ,

11%

2013



, %
30
25
20
15
10
5


, %
30
25
20
15
10
5
0

6
4
8
10
12
,

. 13.

, .

8
10
12
6
,

. 14.

, .

, %
20
18
16
14
12
10
8
6
4
2

, %
18
16
14
12
10
8
6
4
2
0

6
8
10

,

5 6 7 8 9 10

,
4

. 15.

. 16.

14%

2030 .

,
,

4.


5 .

3

, , ..
2.5 ( Y).

.
323
18.5 , 320 32 .

.
. 17.

: n + 3He 3H + 1H + 0.764 .
18.5

84 , 32 48 .
,

C4

. 17.
.
2013

30 .

,
( )
, .
. 4

3%.

, .

,
.

18.5 323

32 320

16%

9%

10%

5%

..

,
100
.

1. .., .., ., 6
., ., .., .., 6
., .., .., .., 6
.., ., .., ..,
.., ., .., 6
.., .., .., ..

400. 31
. . . 2010.
2. .. .
2. .
3. http://geant4.web.cern.ch/geant4/UserDocumentation/
UsersGuides/ForApplicationDeveloper.
4. http://t2.lanl.gov/data/data.html
5. 6 .., .., ..,
..

. . . 1990
6. .., .., .. .

.
2004
9. . 2004. 22 . 13 .

.: 33.

Computer Simulation of the Efficiency of the Detection by the Neutron Detector


of the GAMMA400 GammaRay Telescope
Tant Zin, V. V. Kadilin, and G. L. Dedenko
National Research Nuclear University MEPhI, Kashirskoe sh. 31, Moscow, 115409 Russia
e6mail: tantzin83@gmail.com
Received March 29, 2012

The neutron detector of the GAMMA


400 gamma
ray telescope has been simulated using the GEANT4
toolkit. Three variants of the detector have been used in the simulations. In the first variant, the detector con

sists of alternating layers of a plastic scintillator and cadmium sheets. In the second variant, the detector in

cludes cadmium, boron, plastic scintillator, and polyethylene layers. In the third variant, polyethylene in

cluding gas
discharge counters that are based on gaseous helium
3 and have the shape of cylinders of a given
size is used as a moderator. The neutron detector has been irradiated by a planeparallel neutron flux. The
incident neutron spectrum ranges from 7.94 107 GeV to 13.73 GeV. The efficiencies of the detecting of neu

trons have been calculated for three models of the detector. The most efficient model of the detector has been
chosen by comparing the calculation results.
Keywords: GAMMA
400 gamma
ray telescope, neutron spectrum, simulation of the efficiency.

2013

Вам также может понравиться