Вы находитесь на странице: 1из 9

FIRE FIGHTING EXAMPLE

Fire Sprinkler Reports

for

AHMED RASHAD
EGYPT

Prepared By:
AHMED RASHAD ABD EL AZIZ
EEG
EGYPT

July 23, 2010

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 2

General Project Data Report


General Data
Project Title:
Designed By:
Code Reference:
Client Name:
Address:
Company Name:
Company Address:
Phone:
Building Name:
Contact at Building:
Address Of Building:

Fire Fighting Example


AHMED RASHAD ABD EL AZIZ
NFPA - 13
AHMED RASHAD
EGYPT
EEG
EGYPT

Project File Name:


Date:
Approving Agency:
Phone:
City, State Zip Code:
Representative:
City And State:

AHMED.fiw
July 23, 2010
Civil Defence

Example
EEG
MIDAN LEBNAN

Building Owner:
Phone at Building:
City, State Zip Code:

ANY

Ahmed Rashad Abd El Aziz

Project Data
Description Of Hazard:
Design Area Of Water Application:
Default Sprinkler K-Factor:
Inside Hose Stream Allowance:
In Rack Sprinkler Allowance:
Sprinkler Specifications
Make:
Size:

Ordinary 1
120
5.65
250.00
0.00

ft
K
gpm
gpm

VIKING
1/2"

Sprinkler System Type:


Wet
Maximum Area Per Sprinkler:
130 ft
Default Pipe Material:
SCHED 40 WET STEEL
Outside Hose Stream Allowance:
0.00 gpm

Model:
Temperature Rating:

VK
155 F

Water Supply Test Data


Source Of Information:
Test Hydrant ID:

GOVERNMENT

Hydrant Elevation:
Test Flow Rate:
Calculated System Flow Rate:

38
0 ft
0.00 gpm
260.69 gpm

Date Of Test:

20 JUL, 2010

Static Pressure:
Test Residual Pressure:
Calculated Inflow Residual Pressure:

0.00 psi
0.00 psi
69.04 psi

Calculation Project Data


Calculation Mode:
HMD Minimum Residual Pressure:
Number Of Active Nodes:
Number Of Active Pipes:
Number Of Active Sprinklers:

Demand
7.50 psi
13
12
6

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Minimum Desired Flow Density:


Number Of Inactive Pipes:
Number Of Inactive Sprinklers:

0.15 gpm/ft
0
0

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 3

Fire Sprinkler Input Data


Node Input Data
Area Group
Branch Dia.
(in)

Sprinkler
KFactor (K)
Branch Len.
(ft)

Pressure
Estimate (psi)
Branch Stnd
Fittings

Node Elev (ft)


Branch NonStnd Fittings
(ft)

Non-Sprinkler
Flow (gpm)
Branch Sprk
KFactor (K)

Sprinkler
----

---0.000

5.65
0.0

11.91
----

15.00
0.0

0.00
0.00

Sprinkler
----

---0.000

5.65
0.0

13.53
----

15.00
0.0

0.00
0.00

Sprinkler
----

---0.000

5.65
0.0

15.15
----

15.00
0.0

0.00
0.00

Sprinkler
----

---0.000

5.65
0.0

16.87
----

15.00
0.0

0.00
0.00

No Discharge
----

---0.000

N/A
0.0

25.53
----

15.00
0.0

0.00
0.00

10

Sprinkler
----

---0.000

16.96
0.0

26.23
----

15.00
0.0

0.00
0.00

15

Sprinkler
----

---0.000

16.96
0.0

27.31
----

15.00
0.0

0.00
0.00

16

No Discharge
----

---0.000

N/A
0.0

43.62
----

15.00
0.0

0.00
0.00

17

No Discharge
----

---0.000

N/A
0.0

52.43
----

15.00
0.0

0.00
0.00

18

No Discharge
----

---0.000

N/A
0.0

61.43
----

0.00
0.0

0.00
0.00

19

No Discharge
----

---0.000

N/A
0.0

64.00
----

0.00
0.0

0.00
0.00

20

No Discharge
----

---0.000

N/A
0.0

66.00
----

0.00
0.0

0.00
0.00

21

No Discharge
----

---0.000

N/A
0.0

69.04
----

0.00
0.0

0.00
0.00

Node
No.

Node Description
Branch Description

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 4

Fire Sprinkler Input Data


Pipe Input Data
Nominal
Diameter
(inch)

Type
Group

Nominal
Length
(feet)

Fitting
Length
(feet)

SCHED 40 WET STEEL

1.000

13.00

0.00

13.00

120

SCHED 40 WET STEEL

1.250

13.00

0.00

13.00

120

SCHED 40 WET STEEL

1.500

13.00

0.00

13.00

120

SCHED 40 WET STEEL

1.500

20.50

16.00

36.50

120

10

SCHED 40 WET STEEL

2.000

10.00

0.00

10.00

120

10

15

SCHED 40 WET STEEL

2.500

10.00

0.00

10.00

120

15

16

SCHED 40 WET STEEL

2.500

70.00

0.00

70.00

120

16

17

SCHED 40 WET STEEL

3.000

104.00

5.00

109.00

120

17

18

SCHED 40 WET STEEL

3.000

15.00

16.00

31.00

120

18

19

TYPE M COPPER TUBE

3.000

20.00

7.60

27.60

120

19

20

TYPE M COPPER TUBE

3.000

20.00

1.50

21.50

120

20

21

TYPE M COPPER TUBE

3.000

10.00

22.70

32.70

120

Beg.
Node

End.
Node

Pipe Description

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Fitting
Data

2T

Total
CFactor
Length (gpm/inch(feet)
psi)

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 5

Fire Sprinkler Output Data


Overall Node Groupings Output Data
Pipe Segment
Beg.
End.
Node
Node

Pipe
Type
Group

Pipe
Flow Rate
(gpm)

Sprinkler Flow
At Beg. Node
(gpm)

Non-Sprinkler Flow
Out (+)
In (-)
(gpm)
(gpm)

Beg. Node
Residual
Pressure (psi)

Imbalance
Flow At Beg.
Node (gpm)

-19.50

19.50

0.00

0.00

11.91

2
2

1
3

0
0

19.50
-40.27

20.78

0.00

0.00

13.53

0.00625

3
3

2
4

0
0

40.27
-62.25

21.99

0.00

0.00

15.15

0.01182

4
4

3
5

0
0

62.25
-85.44

23.20

0.00

0.00

16.87

0.01666

5
5

4
10

0
0

85.44
-85.44

0.00

0.00

0.00

25.53

-0.00062

10
10

5
15

0
0

85.44
-172.18

86.86

0.00

0.00

26.23

0.11685

15
15

10
16

0
0

172.18
-260.69

88.63

0.00

0.00

27.31

0.12975

16
16

15
17

0
0

260.69
-260.69

0.00

0.00

0.00

43.62

-0.00037

17
17

16
18

0
0

260.69
-260.69

0.00

0.00

0.00

52.43

-0.00079

18
18

17
19

0
0

260.69
-260.69

0.00

0.00

0.00

61.43

0.00001

19
19

18
20

0
0

260.69
-260.69

0.00

0.00

0.00

64.00

-0.00016

20
20

19
21

0
0

260.69
-260.69

0.00

0.00

0.00

66.00

0.00027

21

20

260.69

0.00

0.00

-260.69

69.04

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 6

Fire Sprinkler Output Data


Overall Pipe Output Data
Beg.
End.
Node

Nodal
KFactor
(K)

Spk/Hose
Elevation
Discharge
(feet)
(gpm)

Nom. Dia.
Residual
Inside Dia.
Pressure
C-Value
(psi)

q (gpm)
Q (gpm)
Velocity
(fps)

F. L./ft
(psi/ft)
Fittings
Type-Grp

Pipe-Len.
Fit-Len.
Tot-Len.
(ft)

PF-(psi)
PE-(psi)
PT-(psi)

1
2

5.65
15.00
19.50
5.65
15.00
20.78
SCHED 40 WET STEEL

11.91
13.53

1.00
1.049
120

19.50
19.50
7.24

0.12417
----0

13.00
0.00
13.00

1.614
0.000
1.614

2
3

5.65
15.00
20.78
5.65
15.00
21.99
SCHED 40 WET STEEL

13.53
15.15

1.25
1.380
120

20.78
40.27
8.64

0.12498
----0

13.00
0.00
13.00

1.625
0.000
1.625

3
4

5.65
15.00
21.99
5.65
15.00
23.20
SCHED 40 WET STEEL

15.15
16.87

1.50
1.610
120

21.99
62.25
9.81

0.13207
----0

13.00
0.00
13.00

1.717
0.000
1.717

4
5

5.65
15.00
23.20
0.00
15.00
0.00
SCHED 40 WET STEEL

16.87
25.53

1.50
1.610
120

23.20
85.44
13.46

0.23726
2T
0

20.50
16.00
36.50

8.660
0.000
8.660

5
10

0.00
15.00
0.00
16.96
15.00
86.86
SCHED 40 WET STEEL

25.53
26.23

2.00
2.067
120

0.00
85.44
8.17

0.07027
----0

10.00
0.00
10.00

0.703
0.000
0.703

10
15

16.96
15.00
86.86
16.96
15.00
88.63
SCHED 40 WET STEEL

26.23
27.31

2.50
2.469
120

86.86
172.18
11.54

0.10813
----0

10.00
0.00
10.00

1.081
0.000
1.081

15
16

16.96
15.00
88.63
0.00
15.00
0.00
SCHED 40 WET STEEL

27.31
43.62

2.50
2.469
120

88.63
260.69
17.47

0.23293
----0

70.00
0.00
70.00

16.305
0.000
16.305

16
17

0.00
15.00
0.00
0.00
15.00
0.00
SCHED 40 WET STEEL

43.62
52.43

3.00
3.068
120

0.00
260.69
11.31

0.08088
L
0

104.00
5.00
109.00

8.815
0.000
8.815

17
18

0.00
15.00
0.00
0.00
0.00
0.00
SCHED 40 WET STEEL

52.43
61.43

3.00
3.068
120

0.00
260.69
11.31

0.08088
C
0

15.00
16.00
31.00

2.507
6.495
9.002

18
19

0.00
0.00
0.00
0.00
0.00
0.00
TYPE M COPPER TUBE

61.43
64.00

3.00
2.981
120

0.00
260.69
11.98

0.09304
L
0

20.00
7.60
27.60

2.568
0.000
2.568

19
20

0.00
0.00
0.00
0.00
0.00
0.00
TYPE M COPPER TUBE

64.00
66.00

3.00
2.981
120

0.00
260.69
11.98

0.09304
G
0

20.00
1.50
21.50

2.000
0.000
2.000

20
21

0.00
0.00
0.00
0.00
0.00
0.00
TYPE M COPPER TUBE

66.00
69.04

3.00
2.981
120

0.00
260.69
11.98

0.09304
T
0

10.00
22.70
32.70

3.042
0.000
3.042

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 7

Fire Sprinkler Output Data


Overall Sprinkler Output Data
Flowing
Sprinkler
Node No.

Area Group
Code

Sprinkler
KFactor (K)

Sprinkler
Elevation
(feet)

Flowing
Density
(gpm/ft)

Sprinkler
Discharge
(gpm)

1
Sub Totals For Non-Group

5.65

15.00

11.91

130.00
130.00

0.150
0.150

19.50
19.50

2
Sub Totals For Non-Group

5.65

15.00

13.53

130.00
130.00

0.160
0.160

20.78
20.78

3
Sub Totals For Non-Group

5.65

15.00

15.15

130.00
130.00

0.169
0.169

21.99
21.99

4
Sub Totals For Non-Group

5.65

15.00

16.87

130.00
130.00

0.178
0.178

23.20
23.20

10
Sub Totals For Non-Group

16.96

15.00

26.23

130.00
130.00

0.668
0.668

86.86
86.86

15
Sub Totals For Non-Group

16.96

15.00

27.31

130.00
130.00

0.682
0.682

88.63
88.63

780.00

0.335

260.97

Totals For All Groups

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

Residual
Flowing Area
Pressure
(ft)
(psi)

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 8

Fire Sprinkler Output Summary


Hydraulically Most Demanding Sprinkler Node
HMD Sprinkler Node Number:
HMD Actual Residual Pressure:
HMD Actual GPM:

1
11.91 psi
19.50 gpm

Sprinkler Summary
Sprinkler System Type:
Specified Area Of Application:
Minimum Desired Density:
Application Average Density:
Application Average Area Per Sprinkler:
Sprinkler Flow:
Average Sprinkler Flow:

Wet
120.00
0.150
2.175
20.00
260.97
43.50

ft
gpm/ft
gpm/ft
ft
gpm
gpm

Flow Velocity And Imbalance Summary


Maximum Flow Velocity ( In Pipe 15 - 16 )
Maximum Velocity Pressure ( In Pipe 15 - 16 )
Allowable Maximum Nodal Pressure Imbalance:
Actual Maximum Nodal Pressure Imbalance:
Actual Average Nodal Pressure Imbalance:
Actual Maximum Nodal Flow Imbalance:
Actual Average Nodal Flow Imbalance:

17.47 ft/sec
2.05 psi
0.1000
0.0838
0.0347
0.1297
0.0218

psi
psi
psi
gpm
gpm

Overall Network Summary


Number Of Unique Pipe Sections:
Number Of Flowing Sprinklers:
Pipe System Water Volume:
Sprinkler Flow:
Non-Sprinkler Flow:
Minimum Required Residual Pressure At System Inflow
Node:
Demand Flow At System Inflow Node:

C:\Program Files\Elite\Firew\PROJECTS\AHMED.fiw

12
6
90.61 gal
260.97 gpm
0.00 gpm
69.04 psi
260.69 gpm

Tuesday, July 27, 2010, 7:57 PM

FIRE - Fire Sprinkler Hydraulics Calculation Program


pReJkEr
Hell

Elite Software Development, Inc.


Fire Fighting Example
Page 9

Fire Sprinkler Output Data


Hydraulic Supply/Demand Graph

100
90
80
69

Pressure psi

70
60
50
40
30
20
10
0
1

10

Flowrate(x100) gpm

Demand Curve Data


Calculated Residual Pressure: 69.04 psi
Calculated Flow Rate: 260.69 gpm
Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 6.50 psi