Вы находитесь на странице: 1из 44

SSP-PRC008-EN

Split System
Heat Pump Product
& Performance Data
XB10
2TWB0012-060A
1 5 Tons

PUB. NO. 22-1744-01-1102 (EN)

General
Features

Split System Heat Pump Units . . .


The Evolution Continues
2TWB0 split systems represent a product
that is not only an engineers dream, it's
also a customers dream. The design
teams mission and accomplishment is
enhanced performance and efficiency,
improved reliability and durability, and
improved installability and serviceability.
Tranes experienced design team applied
six sigma principles, the latest computer

2002 American Standard Inc. All Rights Reserved

technology, and customer research to


develop the next generation of leadership
products.
Couple the Trane reputation for reliability
and durability with the above mentioned
mission and accomplishments and you
continue to have systems that prove
Its Hard to Stop a Trane.

22-1744-01-1102 (EN)

Contents

General Features

Features and Benefits

Optional Equipment
Low Outdoor Ambient Cooling
A.R.I. Standard Capacity Rating Conditions

Selection Procedure
Model Number Nomenclature

General Data
2TWB0012A1000A
2TWB0018A1000A
2TWB0024A1000A
2TWB0030A1000A
2TWB0036A1000A
2TWB0042A1000A
2TWB0048A1000A
2TWB0060A1000A

6
6

7
7
8
9
11
13
15
17
19

Ratings with Auxiliary Devices

21

Performance Data Cooling

24

2TWB0012A1
2TWB0018A1
2TWB0024A1
2TWB0030A1
2TWB0036A1
2TWB0042A1
2TWB0048A1
2TWB0060A1

Performance Data Heating

22-1744-01-1102 (EN)

5
5
5

24
25
26
27
28
29
30
31

32

2TWB0012A1
2TWB0018A1
2TWB0024A1
2TWB0030A1
2TWB0036A1
2TWB0042A1
2TWB0048A1
2TWB0060A1

32
33
34
35
36
37
38
39

Electrical Data

40

Dimensions

42

Mechanical Specification Options

43

Features and
Benefits

Climatuff compressor

Easy top & fan removal

All aluminum Spine Fin coil

Full length control cover

DuraTuff base, fast complete drain,


weather proof

HCFC-22 refrigerant

New cabinet with polystate gray


cabinet
Quick-Sess cabinet, service access
and refrigerant connections with full coil
protection
Corrosion resistant finish and fastners
Internal high/low pressure & temperature protection
Liquid line filter-drier
Easy single side service
Multi-use liquid and suction line service
valves

5-year limited warranty on


compressor, coil, and 5 years on
parts (Residential use)
Extended warranties available
S.E.E.T. design testing
100% line run test
Low ambient cooling to 55F as
shipped
Low ambient to 40F with
EDC accessory AY28X084
Low ambient cooling to 30F with
EDC accessory AY28X084 and TXV

22-1744-01-1102 (EN)

Features and
Benefits

Optional Equipment
] indicates accessories included).
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [
Indoor Thermostats Elec. Setback Thermostat .................................................................................................. TAYSTAT500C [
Prog., 5/2 Day, Manual ........................................................................................................ TAYSTAT540 [
Electronic, 2 Htg./1 Clg. (Non Prog.) .................................................................................... TAYSTAT570 [
Automatic Heat/Cool (Two Stage Heating) ........................................................................... BAY28X138A [
Manual Seasonal Selector Heat/Cool (Two Stage Heating) .............................................. BAYSTAT239A [
Locking Thermostat Cover ......................................................................................................................................... BAY28X190 [
Humidistat ............................................................................................................................................................... BAYSTAT253 [
Outdoor Thermostats 46F. to 10F. (Adjustable) ................................................................................................ TAYSTAT250B [
Evaporator Defrost Control Kit ..................................................................................................................................... AY28X084 [
Indoor Fan Delay Relay ............................................................................................................................................. BAY24X045 [
5 Minute Delay Relay 1 ....................................................................................................................................... TAYASCT501A [
Outdoor Temperature Sensor (TAYSTAT500C) ..................................................................................................... TAYSENS100A [
Snow Legs Base and Cap 4" High ....................................................................................................................... BAYLEGS002 [
Snow Legs addition 4" extension (used with BAYLEGS002) ................................................................................ BAYLEGS003 [
Start Kit (1-5 ton models) ........................................................................................................................................ BAYKSKT257 [
Extreme Conditions Mounting Kit ........................................................................................................................... BAYECMT001 [
Seacoast Kit ........................................................................................................................................................... BAYSEAC001 [
Isolators .................................................................................................................................................................... BAYISLT101 [
Low Ambient Kit ..................................................................................................................................................... BAYLOAM103 [

]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]

1 Do not use with programmable thermostats

BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)
5/8" ODM (90 bend, one end), 5/8" and 1/4" tubing ............................................................................................ TAYREFLN1__* [ ]
3/4" ODM (90 bend, one end), 3/4" and 5/16" tubing .......................................................................................... TAYREFLN2__* [ ]
7/8" ODM (90 bend, one end), 7/8" and 3/8" tubing ............................................................................................ TAYREFLN3__* [ ]
3/4" ODM (90 bend, one end), 1-1/8" and 3/8" tubing ......................................................................................... TAYREFLN4__* [ ]
* Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number.
Example: TAYREFLN220

Low Outdoor Ambient Cooling


Low Ambient
Cooling
FCCV Accutron
Thermal Expansion Valve (TXV)

As
Manufactured

Evaporator
Defrost Control

55F
55F

40F
30F

A.R.I. Standard Capacity Rating Conditions


A.R.I. STANDARD 210/240 RATING CONDITIONS (A) Cooling 80F. D.B., 67F. W.B. air entering indoor coil, 95F. D.B. air
entering outdoor coil. (B) High Temperature Heating 47F. D.B., 43F. W.B. air entering outdoor coil, 70F. D.B. air entering indoor
coil. (C) Low Temperature Heating 17F. D.B., 15F. W.B. air entering outdoor coil, 70F. D.B. air entering indoor coil. (D) Rated
indoor airflow for heating is the same as for cooling.
A.R.I. STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95F. outdoor air.

22-1744-01-1102 (EN)

Selection
Procedure

Model Number Nomenclature


1

10

11

12

13

14

15

Refrigerant Type
2 = R-22
4 = R-410A

Unit Parts
Identifier

TRANE

Minor Design
Modifications

Product Type
W = Split Heat Pump
T = Split Cooling

Secondary
Function

Product Family
Z = LEADERSHIP - 2 STAGE
X = LEADERSHIP
R = REPLACEMENT / RETAIL
B = BASIC
A = LIGHT COMMERCIAL
Family SEER
0 = 10 2 = 12
1 = 11 3 = 13

Power Supply
1 = 200 - 230 / 1 / 60 or 208 - 230 / 1 / 60
3 = 200 - 230 / 3 / 60
4 = 460 / 3 / 60
Major Design Modifications

4 = 14
6 = 16

8 = 18

Nominal Capacity in 000s of BTUs


Split System Connections 1 - 6 Tons
0 = Brazed

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0012A1000A
79
200/230/1/60
10
15
15
CLIMATUFF
1-1
200/230/1/60
7.5 - 42

2TWB0012A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
19 - 1
DIRECT - 1
1575
1 - 1/15
825
200/230/1/60
0.6
SPINE FIN
1 - 24
9.72
3/8
EXPANSION VALVE
R-22
4/09-LB/OZ
YES
5/8
1/4

SPLIT SYSTEM

0.047
H X W X D
30.1 X 26.7 X 30.2
SEE OUTLINE DWG.
169
150

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TXA018C4
CHG TO 47

TXA024C4
CHG TO 47

TXC018C4
CHG TO 47

TXC024C4
CHG TO 47

TXC024D4
CHG TO 47

TXH025A4
CHG TO 47

14100
9300
450
1.44
9.80/10.00

14500
9500
450
1.46
9.95/10.00

14100
9300
450
1.44
9.80/10.00

14500
9500
450
1.46
9.95/10.00

14500
9500
450
1.46
9.95/10.00

14600
9500
450
1.46
10.00/10.00

14200
1.49
2.80
6.80

14400
1.44
2.92
7.00

14200
1.49
2.80
6.80

14400
1.44
2.92
7.00

14400
1.44
2.92
7.00

14400
1.44
2.94
7.00

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TVF018A14
CHG TO 47

TVF024A14
CHG TO 47

TVF025A14
CHG TO 47

TWE018C14
CHG TO 47

TWG018A14
CHG TO 47

TWG025A14
CHG TO 47

15300
10300
450
1.45
10.55/10.00

15000
9900
450
1.54
9.75/10.00

15200
10100
450
1.51
10.05/10.00

14400
9000
400
1.36
10.55/10.00

14600
9800
450
1.42
10.25/10.00

14900
9900
450
1.46
10.20/10.00

14600
1.37
3.12
7.25

14900
1.46
2.98
7.05

14800
1.44
3.02
7.10

14400
1.44
2.92
7.00

14200
1.43
2.90
7.00

14400
1.43
2.96
7.05

page 21 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
MIN. (AMPS)
PROT. RTG.
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0018A1000A
79
200/230/1/60
10
15
15
CLIMATUFF
1-1
200/230/1/60
7.3 - 42

2TWB0018A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
19 - 1
DIRECT - 1
1575
1 - 1/15
825
200/230/1/60
0.6
SPINE FIN
1 - 24
9.72
3/8
EXPANSION VALVE
R-22
4/05-LB/OZ
YES
5/8
1/4

SPLIT SYSTEM

0.049
H X W X D
30.1 X 26.7 X 30.2
SEE OUTLINE DWG.
169
150

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TVF018A14
FACT INS 49

TVF024A14
CHG TO 49

TWE018C14
FACT INS 49

TWE024C14
CHG TO 49

TWG018A14
FACT INS 49

TWG025A14
CHG TO 49

19200
14100
600
1.78
10.80/10.00

19300
14800
675
1.86
10.40/10.00

18400
13300
600
1.70
10.80/10.00

18200
13300
675
1.81
10.05/10.00

18200
13400
600
1.75
10.40/10.00

19000
14500
675
1.81
10.50/10.00

16400
1.48
3.24
7.15

16800
1.54
3.20
7.05

16300
1.51
3.16
6.90

16400
1.59
3.02
6.80

16100
1.55
3.04
6.80

16500
1.54
3.14
7.00

See page 21 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0024A1000A
79
200/230/1/60
15
25
20
CLIMATUFF
1-1
200/230/1/60
10.9 - 60

2TWB0024A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
19 - 1
DIRECT - 1
2175
1 - 1/8
1075
200/230/1/60
0.9
SPINE FIN
1 - 24
9.72
3/8
EXPANSION VALVE
R-22
4/08-LB/OZ
YES
3/4
5/16

SPLIT SYSTEM

0.057
H X W X D
30.1 X 26.7 X 30.2
SEE OUTLINE DWG.
177
158

OUTDOOR UNIT WITH HEAT PUMP COILS


TXA018C4
CHG TO 57

TXA024C4
FACT INS 57

TXA025C4
FACT INS 57

TXA030C4
CHG TO 57

TXC018C4
CHG TO 57

TXC024C4
FACT INS 57

TXC024D4
FACT INS 57

23000
15600
675
2.49
9.25/10.00

24400
17200
800
2.58
9.45/10.00

25000
17800
800
2.62
9.55/10.00

25600
18800
900
2.68
9.55/10.00

23000
15600
675
2.49
9.25/10.00

24400
17200
800
2.58
9.45/10.00

24400
17200
800
2.58
9.45/10.00

21800
2.37
2.70
7.00

22600
2.32
2.86
7.15

23000
2.23
3.02
7.40

23200
2.27
3.00
7.40

21800
2.37
2.70
7.00

22600
2.32
2.86
7.15

22600
2.32
2.86
7.15

TXC025C4
FACT INS 57

TXC025D4
FACT INS 57

TXC030C4
CHG TO 57

TXC030D4
CHG TO 57

TXH025A4
FACT INS 57

TXH033A4
FACT INS 57

25000
17800
800
2.62
9.55/10.00

25000
17800
800
2.62
9.55/10.00

25600
18800
900
2.68
9.55/10.00

25600
18800
900
2.68
9.55/10.00

24600
17400
800
2.60
9.45/10.00

26000
19700
900
2.69
9.65/10.00

23000
2.23
3.02
7.40

23000
2.23
3.02
7.40

23200
2.27
3.00
7.40

23200
2.27
3.00
7.40

22600
2.30
2.88
7.20

23400
2.21
3.10
7.55

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

page 21 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

General
Data

2TWB0024A1000A

OUTDOOR UNIT WITH AIR HANDLERS


TVF018A14
CHG TO 57

TVF024A14
CHG TO 57

TVF025A14
CHG TO 57

TVF030A14
CHG TO 57

TWE018C14
CHG TO 57

TWE024C14
CHG TO 57

TWE030C14
CHG TO 57

25000
17300
675
2.56
9.75/10.00

25400
18200
775
2.62
9.70/10.00

25800
18700
800
2.61
9.90/10.00

26600
20100
900
2.69
9.90/10.00

23800
16100
675
2.48
9.60/10.00

24000
16700
800
2.51
9.55/10.00

25400
18700
900
2.63
9.65/10.00

22600
2.22
2.98
7.50

23000
2.22
3.04
7.55

22800
2.17
3.08
7.60

23400
2.17
3.16
7.70

21800
2.28
2.80
7.15

22800
2.29
2.92
7.25

23000
2.22
3.04
7.50

TWG018A14
CHG TO 57

TWG025A14
CHG TO 57

TWG030A14
CHG TO 57

23200
16200
675
2.46
9.45/10.00

25200
18300
800
2.56
9.85/10.00

25400
19000
900
2.65
9.60/10.00

22000
2.30
2.80
7.20

22600
2.24
2.96
7.40

23000
2.26
2.98
7.40

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

page 21 for combinations with Auxiliary Devices.

10

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0030A1000A
81
200/230/1/60
17
25
20
CLIMATUFF
1-1
200/230/1/60
12.6 - 71

2TWB0030A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
19 - 1
DIRECT - 1
2475
1 - 1/4
1075
200/230/1/60
1.3
SPINE FIN
1 - 24
13.75
3/8
EXPANSION VALVE
R-22
4/11-LB/OZ
YES
3/4
5/16

SPLIT SYSTEM

0.067
H X W X D
33.2 X 26.7 X 30.2
SEE OUTLINE DWG.
187
167

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TXA024C4
CHG TO 67

TXA025C4
CHG TO 67

TXA030C4
FACT INS 67

TXA031C4
FACT INS 67

TXA035C4
CHG TO 67

TXA036C4
CHG TO 67

TXC024C4
CHG TO 67

28000
19600
900
2.98
9.40/10.00

28600
20100
900
2.99
9.55/10.00

29400
21200
1000
3.06
9.60/10.00

29600
21500
1000
3.07
9.65/10.00

29800
22200
1100
3.12
9.55/10.00

30800
23100
1125
3.16
9.75/10.00

28000
19600
900
2.98
9.40/10.00

26400
2.78
2.78
7.35

27000
2.69
2.94
7.65

27200
2.71
2.94
7.55

27600
2.64
3.06
7.75

27400
2.71
2.96
7.60

28000
2.61
3.14
7.90

26400
2.78
2.78
7.35

TXC024D4
CHG TO 67

TXC025C4
CHG TO 67

TXC025D4
CHG TO 67

TXC030C4
FACT INS 67

TXC030D4
FACT INS 67

TXC031C4
FACT INS 67

TXC031D4
FACT INS 67

28000
19600
900
2.98
9.40/10.00

28600
20100
900
2.99
9.55/10.00

28600
20100
900
2.99
9.55/10.00

29400
21200
1000
3.06
9.60/10.00

29400
21200
1000
3.06
9.60/10.00

29600
21500
1000
3.07
9.65/10.00

29600
21500
1000
3.07
9.65/10.00

26400
2.78
2.78
7.35

27000
2.69
2.94
7.65

27000
2.69
2.94
7.65

27200
2.71
2.94
7.55

27200
2.71
2.94
7.55

27600
2.64
3.06
7.75

27600
2.64
3.06
7.75

pages 21 and 22 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

11

General
Data

2TWB0030A1000A

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TXC035C4
CHG TO 67

TXC035D4
CHG TO 67

TXC036C4
CHG TO 67

TXC036D4
CHG TO 67

TXH025A4
CHG TO 67

TXH033A4
CHG TO 67

TXH041A4
FACT INS 67

29800
22200
1100
3.12
9.55/10.00

29800
22200
1100
3.12
9.55/10.00

30800
23100
1125
3.16
9.75/10.00

30800
23100
1125
3.16
9.75/10.00

28000
19600
900
2.98
9.40/10.00

29600
22100
1000
3.07
9.65/10.00

31600
24100
1125
3.19
9.90/10.25

27400
2.71
2.96
7.60

27400
2.71
2.96
7.60

28000
2.61
3.14
7.90

28000
2.61
3.14
7.90

26400
2.76
2.80
7.40

27400
2.64
3.04
7.70

28000
2.61
3.14
7.90

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TVF024A14
CHG TO 67

TVF025A14
CHG TO 67

TVF030A14
FACT INS 67

TVF036A14
CHG TO 67

TWE024C14
CHG TO 67

TWE030C14
FACT INS 67

TWE036C14
CHG TO 67

28600
19600
775
2.95
9.70/10.00

29400
21100
900
3.03
9.70/10.00

30400
22600
1000
3.07
9.90/10.00

31400
24200
1125
3.20
9.80/10.00

27400
18900
900
2.91
9.40/10.00

29200
21200
1000
3.01
9.70/10.00

30600
23500
1125
3.14
9.75/10.00

26800
2.67
2.94
7.65

27200
2.67
2.98
7.65

27600
2.59
3.12
7.90

28200
2.63
3.14
7.95

26200
2.76
2.78
7.40

27600
2.68
3.02
7.60

27600
2.66
3.04
7.75

TWG025A14
CHG TO 67

TWG030A14
CHG TO 67

TWG036A14
CHG TO 67

28600
20600
900
2.93
9.75/10.00

29200
21500
1000
3.03
9.65/10.00

30200
23100
1125
3.11
9.70/10.00

26400
2.67
2.90
7.65

26800
2.69
2.92
7.65

27400
2.66
3.02
7.70

pages 21 and 22 for combinations with Auxiliary Devices.

12

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0036A1000A
81
200/230/1/60
20
30
30
CLIMATUFF
1-1
200/230/1/60
14.7 - 87

2TWB0036A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
19 - 1
DIRECT - 1
2475
1 - 1/4
1075
200/230/1/60
1.3
SPINE FIN
1 - 24
11.32
3/8
EXPANSION VALVE
R-22
5/15-LB/OZ
YES
7/8
3/8

SPLIT SYSTEM

0.067
H X W X D
33.2 X 26.7 X 30.2
SEE OUTLINE DWG.
189
169

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TXA031C4
FACT INS 67

TXA036C4
CHG TO 67

TXA037C4
CHG TO 67

TXA042C4
CHG TO 67

TXC031C4
FACT INS 67

TXC031D4
FACT INS 67

TXC036C4
CHG TO 67

32400
23600
1100
3.52
9.20/10.00

33600
25000
1200
3.61
9.30/10.00

33600
25000
1200
3.61
9.30/10.00

33800
25100
1200
3.61
9.35/10.00

32400
23600
1100
3.52
9.20/10.00

32400
23600
1100
3.52
9.20/10.00

33600
25000
1200
3.61
9.30/10.00

31600
3.13
2.96
6.90

32200
3.10
3.04
7.00

32200
3.10
3.04
7.00

32200
3.08
3.06
7.00

31600
3.13
2.96
6.90

31600
3.13
2.96
6.90

32200
3.10
3.04
7.00

TXC036D4
CHG TO 67

TXC037C4
CHG TO 67

TXC042C4
CHG TO 67

TXH033A4
CHG TO 67

TXH041A4
FACT INS 67

33600
25000
1200
3.61
9.30/10.00

33600
25000
1200
3.61
9.30/10.00

33800
25100
1200
3.61
9.35/10.00

32400
24500
1125
3.52
9.20/10.00

35000
27600
1310
3.74
9.35/10.00

32200
3.10
3.04
7.00

32200
3.10
3.04
7.00

32200
3.08
3.06
7.00

31800
3.15
2.96
6.90

32600
3.10
3.08
7.05

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

page 22 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

13

General
Data

2TWB0036A1000A

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TVF030A14
FACT INS 67

TVF036A14
CHG TO 67

TWE030C14
FACT INS 67

TWE036C14
CHG TO 67

TWE042C14
CHG TO 67

TWG030A14
CHG TO 67

TWG036A14
CHG TO 67

33200
24900
1125
3.59
9.25/10.00

34200
26100
1200
3.68
9.30/10.00

31200
21600
945
3.37
9.25/10.00

34000
25700
1200
3.66
9.30/10.00

34400
27100
1290
3.72
9.25/10.00

31800
23400
1100
3.44
9.25/10.00

32600
24300
1150
3.62
9.00/10.00

32000
3.15
2.98
7.00

32400
3.12
3.04
7.05

30600
3.18
2.82
6.80

32400
3.14
3.02
7.00

32200
3.14
3.00
7.00

31000
3.24
2.80
6.80

31800
3.28
2.84
6.80

TWG037A14
CHG TO 67

TWG042A14
CHG TO 67

33000
25000
1200
3.55
9.30/10.00

33000
25400
1235
3.59
9.20/10.00

31400
3.17
2.90
6.90

31800
3.15
2.96
7.00

page 22 for combinations with Auxiliary Devices.

14

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0042A1000A
79
200/230/1/60
23
40
40
CLIMATUFF
1-1
200/230/1/60
17.3 - 92

2TWB0042A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
NO
YES
PROPELLER
23 - 1
DIRECT - 1
3325
1 - 1/6
825
200/230/1/60
1.4
SPINE FIN
1 - 24
15.18
3/8
EXPANSION VALVE
R-22
6/08-LB/OZ
YES
7/8
3/8

SPLIT SYSTEM

0.075
H X W X D
30.1 X 30.1 X 33.8
SEE OUTLINE DWG.
247
220

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TXA035C4
CHG TO 75

TXA036C4
CHG TO 75

TXA037C4
CHG TO 75

TXA042C4
CHG TO 75

TXA043C4
CHG TO 75

TXA048C4
CHG TO 75

TXC036C4
CHG TO 75

36400
25100
1100
3.77
9.65/10.00

38500
27100
1200
3.91
9.85/10.00

39000
28500
1350
3.96
9.85/10.00

38500
27000
1200
3.87
9.95/10.00

39500
29200
1400
4.01
9.85/10.00

40000
29200
1350
4.00
10.00/10.00

38500
27100
1200
3.91
9.85/10.00

36400
3.70
2.88
7.25

38000
3.55
3.14
7.65

38500
3.53
3.20
7.70

38000
3.50
3.18
7.70

39000
3.51
3.26
7.80

39000
3.44
3.32
7.90

38000
3.55
3.14
7.65

TXC036D4
CHG TO 75

TXC037C4
CHG TO 75

TXC042C4
CHG TO 75

TXC043C4
CHG TO 75

TXC048C4
CHG TO 75

TXH041A4
CHG TO 75

TXH054A4
CHG TO 75

38500
27100
1200
3.91
9.85/10.00

39000
28500
1350
3.96
9.85/10.00

38500
27000
1200
3.87
9.95/10.00

39500
29200
1400
4.01
9.85/10.00

40000
29200
1350
4.00
10.00/10.00

40500
30400
1400
4.05
10.00/10.00

42500
33800
1575
4.21
10.10/10.00

38000
3.55
3.14
7.65

38500
3.53
3.20
7.70

38000
3.50
3.18
7.70

39000
3.51
3.26
7.80

39000
3.44
3.32
7.90

39000
3.51
3.26
7.80

40000
3.41
3.44
8.10

See page 22 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

15

General
Data

2TWB0042A1000A

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TVF036A14
CHG TO 75

TWE036C14
CHG TO 75

TWE042C14
CHG TO 75

TWE048C14
CHG TO 75

TWE060A
TXV-B

TWG037A14
CHG TO 75

TWG042A14
CHG TO 75

39500
29600
1350
4.09
9.65/10.00

38500
28600
1350
3.99
9.65/10.00

40500
30400
1400
4.07
9.95/10.00

41000
32200
1535
4.16
9.85/10.00

40500
31000
1515
3.91
10.35/10.50

37600
27600
1275
3.88
9.70/10.00

38000
28000
1400
3.90
9.75/10.00

39000
3.59
3.18
7.75

38000
3.66
3.04
7.50

39000
3.53
3.24
7.70

39500
3.53
3.28
7.85

39000
3.38
3.38
8.05

37200
3.66
2.98
7.40

38000
3.59
3.10
7.60

TWG048A14
CHG TO 75
41000
32100
1535
4.12
9.95/10.00
39000
3.51
3.26
7.90

page 22 for combinations with Auxiliary Devices.

16

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0048A1000A
80
200/230/1/60
26
40
40
CLIMATUFF
1-1
200/230/1/60
19.0 - 105

2TWB0048A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
YES
YES
PROPELLER
23 - 1
DIRECT - 1
3675
1 - 1/4
825
200/230/1/60
1.9
SPINE FIN
1 - 24
15.18
3/8
EXPANSION VALVE
R-22
8/04-LB/OZ
YES
1-1/8
3/8

SPLIT SYSTEM

0.083
H X W X D
30.1 X 30.1 X 33.8
SEE OUTLINE DWG.
255
228

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TXA042C4
CHG TO 83

TXA043C4
CHG TO 83

TXA048C4
FACT INS 83

TXA049C4
FACT INS 83

TXA050C4
FACT INS 83

TXA060C5
TXV-B

TXA061C5
TXV-B

42000
28600
1200
4.31
9.75/10.00

44000
32600
1575
4.54
9.70/10.00

43500
30700
1350
4.42
9.85/10.00

45000
33500
1600
4.59
9.80/10.00

45000
33500
1600
4.59
9.80/10.00

46000
34500
1700
4.67
9.85/10.25

47000
36600
1760
4.75
9.90/10.50

42000
4.02
3.06
7.20

43500
4.03
3.16
7.35

43000
3.96
3.18
7.35

43500
3.93
3.24
7.50

43500
3.93
3.24
7.50

44000
3.91
3.30
7.50

44500
3.95
3.30
7.35

TXC042C4
CHG TO 83

TXC043C4
CHG TO 83

TXC048C4
FACT INS 83

TXC049C4
FACT INS 83

TXC050C4
FACT INS 83

TXC060C5
TXV-B

TXC061C5
TXV-B

42000
28600
1200
4.31
9.75/10.00

44000
32600
1575
4.54
9.70/10.00

43500
30700
1350
4.42
9.85/10.00

45000
33500
1600
4.59
9.80/10.00

45000
33500
1600
4.59
9.80/10.00

46000
34500
1700
4.67
9.85/10.25

47000
36600
1760
4.75
9.90/10.50

42000
4.02
3.06
7.20

43500
4.03
3.16
7.35

43000
3.96
3.18
7.35

43500
3.93
3.24
7.50

43500
3.93
3.24
7.50

44000
3.91
3.30
7.50

44500
3.95
3.30
7.35

pages 22 and 23 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

17

General
Data

2TWB0048A1000A

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TXH041A4
CHG TO 83

TXH054A4
FACT INS 83

45000
33800
1575
4.57
9.85/10.00

48000
37500
1700
4.78
10.05/10.25

43500
4.03
3.16
7.35

44500
3.90
3.34
7.35

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TWE042C14
CHG TO 83

TWE048C14
FACT INS 83

TWE060A
TXV-B

TWE060C/D15
TXV-B

TWG048A14
FACT INS 83

TWG060A15
TXV-B

44000
33000
1575
4.63
9.50/10.00

45500
34400
1600
4.69
9.70/10.00

46000
35200
1725
4.53
10.15/10.50

46500
36000
1740
4.95
9.40/10.00

45000
33900
1600
4.62
9.75/10.00

46500
36000
1740
4.84
9.60/10.25

43000
4.14
3.04
7.20

44500
4.02
3.24
7.35

43000
3.84
3.28
7.50

44500
4.13
3.16
7.20

43500
4.06
3.14
7.30

44500
4.05
3.22
7.25

pages 22 and 23 for combinations with Auxiliary Devices.

18

22-1744-01-1102 (EN)

General
Data
OUTDOOR UNIT 12
SOUND RATING (DECIBELS) 2
POWER CONNS. V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR.
MAX. (AMPS)
PROT. RTG.
MIN. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN TYPE
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP.
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
(O.D. UNIT) NP CHRG. 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
FCCV
RESTRICTOR ORIFICE SIZE
DIMENSIONS
OUTDOOR UNIT CRATED (IN.)
UNCRATED
WEIGHT
SHIPPING (LBS.)
NET (LBS.)

2TWB0060A1000A
81
200/230/1/60
34
50
50
CLIMATUFF
1-1
200/230/1/60
25.9 - 141

2TWB0060A1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARY


HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM WHICH IS
BASED ON A.R.I. STANDARD 210/240.
2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.
ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4 STANDARD AIR - DRY COIL - OUTDOOR
5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT
NAMEPLATE AND SERVICE INSTRUCTION.
6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID
60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING
SOFTWARE PUB. NO. 32-3312-01.
7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT
NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO
COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM
FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT
SELECTION CURRENT.
8 NO MEANS NO START COMPONENTS
YES MEANS QUICK START KIT COMPONENTS
PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

NO
YES
YES
PROPELLER
27.6 - 1
DIRECT - 1
4400
1 - 1/6
825
200/230/1/60
1.4
SPINE FIN
1 - 24
21.99
3/8
EXPANSION VALVE
R-22
9/08-LB/OZ
YES
1-1/8
3/8

SPLIT SYSTEM

0.095
H X W X D
38.4 X 35.1 X 38.7
SEE OUTLINE DWG.
291
259

OUTDOOR UNIT WITH HEAT PUMP COILS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)
See

TXA048C4
CHG TO 95

TXA049C4
CHG TO 95

TXA050C4
CHG TO 95

TXA060C5
TXV-B

TXA061C5
TXV-B

TXC048C4
CHG TO 95

TXC049C4
CHG TO 95

54000
35400
1350
5.74
9.40/10.00

56500
39100
1675
5.95
9.50/10.00

56500
39100
1675
5.95
9.50/10.00

58000
39700
1700
6.01
9.65/10.50

59500
41900
1800
6.10
9.75/10.50

54000
35400
1350
5.74
9.40/10.00

56500
39100
1675
5.95
9.50/10.00

53000
5.25
2.96
7.55

54500
5.22
3.06
7.60

54500
5.22
3.06
7.60

55000
5.17
3.12
7.65

55000
5.13
3.14
7.70

53000
5.25
2.96
7.55

54500
5.22
3.06
7.60

TXC050C4
CHG TO 95

TXC060C5
TXV-B

TXC061C5
TXV-B

TXH041A4
CHG TO 95

TXH054A4
CHG TO 95

56500
39100
1675
5.95
9.50/10.00

58000
39700
1700
6.01
9.65/10.50

59500
41900
1800
6.10
9.75/10.50

56500
38800
1575
5.92
9.55/10.00

60500
42700
1700
6.11
9.90/10.25

54500
5.22
3.06
7.60

55000
5.17
3.12
7.65

55000
5.13
3.14
7.70

53500
5.26
2.98
7.55

55000
5.13
3.14
7.75

page 23 for combinations with Auxiliary Devices.

22-1744-01-1102 (EN)

19

General
Data

2TWB0060A1000A

OUTDOOR UNIT WITH AIR HANDLERS

EXPANSION TYPE
RATINGS (COOLING) 1
BTUH (TOTAL)
BTUH (SENSIBLE)
INDOOR AIRFLOW (CFM)
SYSTEM POWER (KW)
EER/SEER (BTU/WATT-HR.)
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH
SYSTEM POWER (KW)
COP
HSPF (BTU/WATT-HR.)

TWE042C14
CHG TO 95

TWE048C14
CHG TO 95

TWE060A
TXV-B

TWE060C/D15
TXV-B

TWG048A14
CHG TO 95

TWG060A15
TXV-B

55000
37800
1575
5.91
9.30/10.00

58500
41600
1800
6.19
9.45/10.00

59000
42400
2000
5.99
9.85/10.50

59000
42500
1945
6.38
9.25/10.00

56500
39100
1625
5.95
9.50/10.00

60000
43600
2000
6.38
9.40/10.25

53000
5.47
2.84
7.35

55000
5.37
3.00
7.50

54500
5.09
3.14
7.70

57000
5.39
3.10
7.55

53500
5.33
2.94
7.50

56000
5.33
3.08
7.65

See page 23 for combinations with Auxiliary Devices.

20

22-1744-01-1102 (EN)

Ratings with
Auxiliary Devices
COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or TXV
kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
OUTDOOR
MODEL
2TWB0012A10 *
2TWB0012A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10 *
2TWB0018A10
2TWB0018A10
2TWB0018A10
2TWB0018A10
2TWB0018A10
2TWB0018A10
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0024A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *

INS
KIT
N
N
N
N
N
N
N
Y
N
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

INDOOR
MODEL
TWE018P13
TWE024P13
TVF018A14
TVF024A14
TWE018C14
TWE018P13
TWE024P13
TWG018A14
TWG025A14
TXA018C4
TXA024C4
TXC018C4
TXC024C4
TXC024D4
TXH025A4
TVF018A14
TVF024A14
TVF025A14
TVF030A14
TWE018P13
TWE024C14
TWE024P13
TWE030C14
TWE030P13
TWE060B
TWG025A14
TWG030A14
TXA024C4
TXA025C4
TXA030C4
TXC024C4
TXC024D4
TXC025C4
TXC025D4
TXC030C4
TXC030D4
TXH025A4
TXH033A4
TVF030A14
TVF036A14
TWE024P13
TWE030C14
TWE030P13
TWE036C14
TWE036P13
TWE060B
TWG030A14
TWG036A14
TXA030C4
FI - FACTORY INSTALLED

22-1744-01-1102 (EN)

FAN
DELAY
KIT
N
N
FI
FI
FI
N
N
FI
FI
N
N
N
N
N
N
FI
FI
FI
FI
N
FI
N
FI
N
Y
FI
FI
N
N
N
N
N
N
N
N
N
N
N
FI
FI
N
FI
N
FI
N
Y
FI
FI
N
B - BLEED TXV

TXV
KIT
NO
NO
NB
NB
NB
NO
NO
NB
NB
NO
NO
NO
NO
NO
NO
NB
NB
NB
NB
NO
NB
NO
NB
NO
NO
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NO
NB
NO
NB
NO
NO
NB
NB
NB

CFM
450
450
600
675
600
600
675
600
675
600
675
600
675
675
675
675
775
800
900
675
800
800
900
900
1800
800
900
800
800
900
800
800
800
800
900
900
800
900
1000
1125
900
1000
940
1125
1125
2000
1000
1125
1000

SEER
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.00
10.00
10.00
10.00
10.00
10.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.85
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50

NB - NON-BLEED TXV

21

COOLING
CAPACITY
15200
15200
19100
19200
18200
19000
19400
18100
18900
17600
18500
17600
18500
18500
18600
24600
25200
25400
26400
24800
23800
25800
25200
26000
50000
24800
25000
24200
24600
25400
24200
24200
24600
24600
25400
25400
24200
25800
30600
31200
29800
29400
30000
30400
30800
58000
29200
30200
29600

HI-TEMP
HEATING
14600
14600
16400
16800
16300
16500
16600
16100
16500
16100
16500
16100
16500
16500
16500
22600
23000
22800
23400
22600
22800
22800
23000
23200
46000
22600
23000
22600
23000
23200
22600
22600
23000
23000
23200
23200
22600
23400
27600
28200
27000
27600
27000
27600
27800
54000
26800
27400
27200

* - START KIT REQUIRED

HSPF
7.10
7.10
7.00
7.00
6.90
7.00
7.05
6.80
6.85
6.80
6.80
6.80
6.80
6.80
6.80
7.35
7.50
7.55
7.65
7.40
7.25
7.55
7.50
7.55
7.50
7.35
7.35
7.15
7.40
7.40
7.15
7.15
7.40
7.40
7.40
7.40
7.20
7.55
7.80
7.80
7.60
7.60
7.70
7.70
7.75
7.70
7.55
7.65
7.55

HI-TEMP
COP
3.12
3.12
3.24
3.20
3.16
3.20
3.28
3.04
3.14
2.92
3.04
2.92
3.04
3.04
3.06
2.98
3.04
3.08
3.16
3.00
2.92
3.10
3.04
3.10
3.00
2.96
2.98
2.86
3.02
3.00
2.86
2.86
3.02
3.02
3.00
3.00
2.88
3.10
3.12
3.14
2.98
3.02
3.02
3.04
3.10
2.94
2.92
3.02
2.94

Ratings with
Auxiliary Devices
COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or TXV
kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
OUTDOOR
MODEL
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10
2TWB0030A10 *
2TWB0030A10 *
2TWB0030A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0036A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0042A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *

INS
KIT
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

INDOOR
MODEL
TXA031C4
TXA036C4
TXC030C4
TXC030D4
TXC031C4
TXC031D4
TXC036C4
TXC036D4
TXC036D4
TXH033A4
TXH041A4
TVF036A14
TWE030P13
TWE036C14
TWE036P13
TWE042C14
TWE042P13
TWG037A14
TWG042A14
TXA036C4
TXA037C4
TXA042C4
TXC036C4
TXC036D4
TXC037C4
TXC042C4
TXH041A4
TWE036P13
TWE042C14
TWE042P13
TWE048C14
TWE090B
TWE120B
TWG048A14
TXA042C4
TXA043C4
TXA048C4
TXC042C4
TXC043C4
TXC048C4
TXH041A4
TXH054A4
TWE042P13
TWE048C14
TWE090B
TWE120B
TWG042A14
TWG048A14
TXA048C4
FI - FACTORY INSTALLED

FAN
DELAY
KIT
N
N
N
N
N
N
N
Y
N
N
N
FI
N
FI
N
FI
N
FI
FI
N
N
N
N
N
N
N
N
N
FI
N
FI
N
N
FI
N
N
N
N
N
N
N
N
N
FI
N
N
FI
FI
N

TXV
KIT
NB
NB
NB
NB
NB
NB
NB
NO
NB
NB
NB
NB
NO
NB
NO
NB
NO
NB
NB
NB
NB
NB
NB
NB
NB
NB
NB
NO
NB
NO
NB
NO
NO
NB
NB
NB
NB
NB
NB
NB
NB
NB
NO
NB
NO
NO
NB
NB
NB

CFM
1000
1125
1000
1000
1000
1000
1125
1125
1125
1000
1125
1200
940
1200
1200
1265
1295
1200
1230
1200
1200
1200
1200
1200
1200
1200
1290
1350
1400
1400
1535
3000
3110
1515
1200
1400
1350
1200
1400
1350
1400
1575
1575
1600
3000
3485
1500
1600
1350

B - BLEED TXV

SEER
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.25
10.50
10.50
10.50
9.75#
9.80#
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
9.60#
9.65#
10.00
10.50
10.50

NB - NON-BLEED TXV

22

COOLING
CAPACITY
29800
30600
29600
29600
29800
29800
30600
30800
30600
29800
31400
33600
32200
33600
33200
33800
34600
32600
32800
33200
33200
33400
33200
33200
33200
33400
34400
39000
40000
40500
41000
80000
83000
40500
38500
39500
40000
38500
39500
40000
40000
42000
45500
45500
88000
93000
42000
45000
44000

HI-TEMP
HEATING
27600
28000
27200
27200
27600
27600
28000
28000
28000
27400
28000
32400
30800
32400
32000
32200
32600
31400
31600
32200
32200
32200
32200
32200
32200
32200
32400
38500
39000
39000
39500
75000
77000
39000
38000
39000
39000
38000
39000
39000
39000
40000
43500
44500
83000
86000
42000
43500
43000

HSPF
7.75
7.90
7.55
7.55
7.75
7.75
7.90
7.95
7.90
7.70
7.90
7.00
6.85
7.00
7.00
6.90
7.00
6.85
6.90
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.00
7.55
7.70
7.75
7.80
8.00
8.15
7.80
7.70
7.80
7.90
7.70
7.80
7.90
7.80
8.10
7.30
7.35
7.40
7.60
7.10
7.25
7.35

HI-TEMP
COP
3.06
3.14
2.94
2.94
3.06
3.06
3.14
3.14
3.14
3.04
3.14
3.04
2.88
3.02
3.00
3.00
3.08
2.90
2.96
3.04
3.04
3.06
3.04
3.04
3.04
3.06
3.08
3.12
3.24
3.26
3.28
3.28
3.42
3.26
3.18
3.26
3.32
3.18
3.26
3.32
3.26
3.44
3.18
3.24
3.10
3.28
2.98
3.14
3.18

* - START KIT REQUIRED

22-1744-01-1102 (EN)

Ratings with
Auxiliary Devices
COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or TXV
kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
OUTDOOR
MODEL
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10 *
2TWB0048A10
2TWB0048A10 *
2TWB0048A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *
2TWB0060A10 *

INS
KIT
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

INDOOR
MODEL
TXA049C4
TXA050C4
TXA060C5
TXC048C4
TXC049C4
TXC050C4
TXC060C5
TXH041A4
TXH054A4
TWE042P13
TWE048P13
TWE060P13
TWE063P13
TWE120B
TXH041A4
TXH054A4
TXH063P3-A
TXH063P3-B

FI - FACTORY INSTALLED

22-1744-01-1102 (EN)

FAN
DELAY
KIT
N
N
Y
N
N
N
Y
N
N
N
N
N
N
N
N
N
N
N

B - BLEED TXV

TXV
KIT
NB
NB
NO
NB
NB
NB
NO
NB
NB
NO
NO
NO
NO
NO
NB
NB
NO
NO

CFM
1600
1600
1700
1350
1600
1600
1700
1575
1700
1575
1800
1800
1800
4000
1575
1700
2000
2000

SEER
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.25
10.50
10.50
10.50
9.45#
10.50
10.50
10.50
10.50

NB - NON-BLEED TXV

23

COOLING
CAPACITY
45000
45000
46000
44000
45000
45000
46000
45500
47500
57000
61500
61500
61500
11800
57000
60000
62500
63000

HI-TEMP
HEATING
43500
43500
44000
43000
43500
43500
44000
43500
44500
53500
55500
55500
56500
108000
53500
55000
56500
56500

* - START KIT REQUIRED

HSPF
7.50
7.50
7.55
7.35
7.50
7.50
7.55
7.35
7.35
7.55
7.80
7.80
7.75
7.75
7.55
7.75
7.90
7.90

HI-TEMP
COP
3.24
3.24
3.30
3.18
3.24
3.24
3.30
3.16
3.34
2.98
3.22
3.22
3.20
3.10
2.98
3.14
3.28
3.28

Performance Data
2TWB0012A1
Cooling
2TWB0012A1 WITH TWE018C14 AT 400 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
12.6
13.7
14.8
16.0

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
9.0
10.0
11.0
11.7
7.8
8.8
9.8
10.4
6.4
7.4
8.4
9.0
4.9
5.9
6.9
7.6

TOTAL
KW
1.23
1.25
1.27
1.29

59
63
67
71

12.4
13.4
14.4
15.5

8.9
7.6
6.2
4.7

9.9
8.7
7.2
5.8

10.9
9.6
8.2
6.7

11.6
10.3
8.9
7.4

1.34
1.35
1.36
1.38

59
63
67
71

11.9
12.8
13.8
14.7

8.7
7.4
6.0
4.5

9.7
8.4
7.0
5.5

10.7
9.4
8.0
6.5

11.4
10.1
8.6
7.1

1.46
1.46
1.47
1.48

59
63
67
71

11.4
12.3
13.1
14.0

8.5
7.2
5.7
4.2

9.5
8.2
6.8
5.3

10.5
9.2
7.7
6.2

11.2
9.8
8.4
6.9

1.57
1.57
1.58
1.58

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE018C14

TWG018A14

TWG025A14

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

400
350
450
450
400
500
450
400
500

1.00
0.97
1.03
1.00
0.97
1.02
1.02
0.99
1.04

1.00
0.94
1.06
1.10
1.05
1.16
1.11
1.05
1.17

1.00
1.02
0.98
1.03
1.04
1.02
1.05
1.06
1.04

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

350
450

0.97
1.03

0.94
1.06

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF018A14
RATED
450
1.05
1.15
1.05
LOW
400
1.02
1.08
1.06
HIGH
500
1.07
1.22
1.04
TVF024A14
RATED
450
1.02
1.12
1.11
LOW
400
1.00
1.05
1.12
HIGH
500
1.05
1.17
1.10
TVF025A14
RATED
450
1.04
1.14
1.09
LOW
400
1.02
1.07
1.10
HIGH
500
1.06
1.20
1.08

24

22-1744-01-1102 (EN)

Performance Data
2TWB0018A1
Cooling
2TWB0018A1 WITH TWE018C14 AT 600 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
16.0
17.3
18.7
20.2

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
13.5
15.1
16.3*
16.7*
11.4
13.1
14.6
15.7
9.2
10.8
12.4
13.4
6.9
8.5
10.0
11.1

TOTAL
KW
1.53
1.56
1.58
1.61

59
63
67
71

15.7
17.0
18.4
19.8

13.3
11.3
9.0
6.7

14.9
12.9
10.7
8.4

16.0*
14.5
12.2
9.9

16.4*
15.5
13.3
11.0

1.67
1.68
1.70
1.72

59
63
67
71

14.6
15.9
17.2
18.6

12.8
10.8
8.6
6.3

14.3
12.4
10.2
7.9

15.2*
14.0
11.7
9.4

15.6*
15.1
12.8
10.5

1.78
1.79
1.81
1.82

59
63
67
71

13.6
14.8
16.0
17.3

12.3
10.3
8.1
5.8

13.7
12.0
9.7
7.4

14.3*
13.5
11.3
9.0

14.7*
14.6
12.3
10.0

1.90
1.90
1.91
1.91

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE024C14

TWG018A14

TWG025A14

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

525
675

0.98
1.02

0.94
1.05

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF018A14
RATED
600
1.04
1.06
1.04
LOW
525
1.02
1.00
1.05
HIGH
675
1.07
1.13
1.03
TVF024A14
RATED
700
1.05
1.12
1.09
LOW
600
1.03
1.04
1.10
HIGH
800
1.06
1.20
1.08
TWE018C14
RATED
600
1.00
1.00
1.00
LOW
525
0.98
0.94
1.01
HIGH
675
1.02
1.05
0.99

22-1744-01-1102 (EN)

25

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

700
600
800
600
525
675
700
600
800

0.99
0.97
1.00
0.99
0.97
1.01
1.04
1.02
1.05

1.02
0.95
1.08
1.01
0.95
1.06
1.10
1.02
1.16

1.07
1.08
1.06
1.03
1.04
1.02
1.07
1.08
1.06

Performance Data
Cooling
2TWB0024A1
2TWB0024A1 WITH TWE024C14 AT 800 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
20.8
22.5
24.4
26.3

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
17.0
19.0
20.8*
21.4*
14.4
16.5
18.4
19.7
11.6
13.6
15.6
16.9
8.7
10.7
12.7
14.0

TOTAL
KW
2.23
2.28
2.33
2.39

59
63
67
71

20.4
22.2
24.0
25.9

16.8
14.3
11.4
8.5

18.8
16.3
13.5
10.5

20.6*
18.3
15.4
12.5

21.2*
19.6
16.7
13.8

2.42
2.46
2.51
2.56

59
63
67
71

19.1
20.7
22.5
24.2

16.2
13.7
10.8
7.9

18.2
15.7
12.8
9.9

19.5*
17.6
14.8
11.9

20.1*
19.0
16.1
13.2

2.58
2.62
2.66
2.70

59
63
67
71

17.7
19.3
20.9
22.6

15.6
13.0
10.2
7.3

17.4
15.1
12.2
9.3

18.5*
17.0
14.2
11.3

19.0*
18.4
15.5
12.6

2.75
2.78
2.81
2.84

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE018C14

TWE024C14

TWE030C14

TWG018A14

TWG025A14

TWG030A14

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

700
900

0.98
1.02

TXA024C4

0.94
1.05

TXA025C4

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXC024C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF018A14
RATED
700
1.05
1.05
1.03
LOW
600
1.02
0.97
1.04
HIGH
800
1.07
1.11
1.00
TVF024A14
RATED
800
1.06
1.10
1.04
LOW
700
1.04
1.04
1.05
HIGH
900
1.08
1.17
1.03
TVF025A14
RATED
800
1.08
1.11
1.03
LOW
700
1.05
1.05
1.04
HIGH
900
1.10
1.18
1.02
TVF030A14
RATED
900
1.11
1.19
1.06
LOW
775
1.09
1.10
1.08
HIGH
1025
1.12
1.26
1.04

TXC024D4

TXC025C4

TXC025D4

TXH025A4

26

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

700
600
800
800
700
900
900
775
1025
700
600
800
800
700
900
900
775
1025
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900

1.00
0.97
1.02
1.00
0.98
1.02
1.06
1.04
1.08
0.97
0.94
0.99
1.05
1.03
1.07
1.06
1.04
1.07
1.02
0.99
1.04
1.04
1.02
1.06
1.02
0.99
1.04
1.02
0.99
1.04
1.04
1.02
1.06
1.04
1.02
1.06
1.02
1.00
1.04

0.98
0.92
1.04
1.00
0.94
1.05
1.11
1.04
1.18
0.98
0.92
1.04
1.08
1.02
1.14
1.12
1.06
1.19
1.03
0.97
1.08
1.06
0.99
1.11
1.03
0.97
1.08
1.03
0.97
1.08
1.06
0.99
1.11
1.06
0.99
1.11
1.03
0.98
1.08

0.99
1.00
0.97
1.00
1.01
0.99
1.04
1.05
1.03
0.98
0.99
0.96
1.01
1.03
1.00
1.05
1.06
1.04
1.03
1.04
1.01
1.04
1.05
1.03
1.03
1.04
1.01
1.03
1.04
1.01
1.04
1.05
1.03
1.04
1.05
1.03
1.03
1.04
1.02

22-1744-01-1102 (EN)

Performance Data
Cooling
2TWB0030A1
2TWB0030A1 WITH TWE030C14 AT 1000 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
25.4
27.5
29.7
32.0

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
21.5
24.2
25.9*
26.6*
18.1
20.8
23.4
25.2
14.3
17.0
19.6
21.4
10.4
13.1
15.7
17.5

TOTAL
KW
2.68
2.73
2.79
2.84

59
63
67
71

24.9
27.0
29.2
31.5

21.3
17.9
14.1
10.2

24.0
20.6
16.8
12.9

25.6*
23.2
19.4
15.5

26.3*
25.0
21.2
17.3

2.92
2.96
3.01
3.06

59
63
67
71

23.2
25.2
27.2
29.3

20.5
17.1
13.3
9.4

22.9
19.8
16.0
12.1

24.2*
22.4
18.6
14.7

24.8*
24.2
20.4
16.5

3.13
3.16
3.20
3.24

59
63
67
71

21.5
23.3
25.2
27.2

19.8
16.3
12.5
8.6

21.9
19.0
15.2
11.3

22.8*
21.7
17.9
14.0

23.4*
23.4*
19.6
15.7

3.34
3.37
3.40
3.42

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE024C14

TWE030C14

TWE036C14

TWG025A14

TWG030A14

TWG036A14

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

875
1125

0.98
1.02

TXA030C4

0.94
1.05

TXA031C4

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXC030C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF024A14
RATED
800
0.99
0.95
0.99
LOW
700
0.96
0.89
1.00
HIGH
900
1.01
1.00
0.98
TVF025A14
RATED
900
1.01
1.00
1.01
LOW
775
0.98
0.93
1.02
HIGH
1025
1.03
1.06
1.00
TVF030A14
RATED
1000
1.04
1.06
1.02
LOW
875
1.02
1.00
1.03
HIGH
1125
1.06
1.13
1.01
TVF036A14
RATED
1100
1.07
1.12
1.06
LOW
950
1.05
1.04
1.07
HIGH
1250
1.09
1.18
1.05

22-1744-01-1102 (EN)

TXC030D4

TXC031C4

TXC031D4

TXH025A4

TXH033A4

27

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

900
775
1025
1000
875
1125
1100
950
1250
900
775
1025
1000
875
1125
1100
950
1250
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
900
775
1025
1000
875
1125

0.95
0.92
0.97
1.00
0.98
1.02
1.05
1.03
1.06
0.96
0.93
0.98
1.00
0.98
1.01
1.03
1.01
1.04
1.01
0.99
1.03
1.01
0.99
1.03
1.01
0.99
1.03
1.01
0.99
1.03
1.01
0.99
1.03
1.01
0.99
1.03
0.96
0.93
0.98
1.01
0.99
1.03

0.90
0.85
0.96
1.00
0.94
1.05
1.09
1.02
1.15
0.96
0.90
1.02
1.01
0.96
1.06
1.07
1.01
1.13
1.00
0.94
1.05
1.02
0.95
1.07
1.00
0.94
1.05
1.00
0.94
1.05
1.02
0.95
1.07
1.02
0.95
1.07
0.93
0.87
0.98
1.04
0.97
1.09

0.97
0.98
0.96
1.00
1.01
0.99
1.04
1.05
1.03
0.97
0.98
0.96
1.01
1.02
1.00
1.03
1.04
1.02
1.02
1.03
1.01
1.02
1.03
1.01
1.02
1.03
1.01
1.02
1.03
1.01
1.02
1.03
1.01
1.02
1.03
1.01
0.99
1.00
0.98
1.02
1.03
1.01

Performance Data
Cooling
2TWB0036A1
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW

2TWB0036A1 WITH TWE036C14 AT 1200 CFM


O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
29.9
32.2
34.7
37.2

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
26.3
29.4
31.0*
31.7*
22.0
25.3
28.6
30.7
17.3
20.5
23.8
26.0
12.4
15.7
19.0
21.1

TOTAL
KW
3.21
3.29
3.38
3.46

59
63
67
71

29.3
31.6
34.0
36.5

26.0
21.7
17.0
12.1

29.0
25.0
20.3
15.4

30.5*
28.3
23.5
18.7

31.2*
30.5
25.7
20.9

3.49
3.57
3.66
3.74

59
63
67
71

27.3
29.4
31.6
34.0

25.1
20.8
16.0
11.2

27.6
24.1
19.3
14.5

28.7*
27.3
22.6
17.7

29.4*
29.4*
24.8
19.9

3.73
3.81
3.89
3.97

59
63
67
71

25.2
27.2
29.3
31.4

24.1
19.8
15.1
10.3

26.0
23.1
18.4
13.5

27.0*
26.4
21.6
16.8

27.6*
27.6*
23.8
19.0

3.97
4.05
4.12
4.20

TWE036C14

TWE042C14

TWG030A14

TWG036A14

TWG037A14

TWG042A14

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1050
1350

0.98
1.01

TXA036C4

0.95
1.05

TXA037C4

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXC036C4

TXC036D4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF030A14
RATED
1100
0.97
0.96
0.98
LOW
950
0.95
0.90
0.99
HIGH
1250
0.98
1.02
0.97
TVF036A14
RATED
1200
1.00
1.01
1.00
LOW
1050
0.98
0.95
1.01
HIGH
1350
1.02
1.07
0.99
TWE030C14
RATED
900
0.91
0.84
0.92
LOW
775
0.88
0.79
0.93
HIGH
1025
0.93
0.89
0.91

TXC037C4

TXH041A4

28

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1200
1050
1350
1400
1225
1575
1100
950
1250
1200
1050
1350
1200
1050
1350
1400
1225
1575
1200
1050
1350
1200
1050
1350
1200
1050
1350
1200
1050
1350
1200
1050
1350
1400
1225
1575

1.00
0.98
1.01
1.01
1.00
1.02
0.93
0.92
0.94
0.96
0.94
0.97
0.97
0.95
0.98
0.97
0.96
0.98
0.99
0.97
1.00
0.99
0.97
1.00
0.99
0.97
1.00
0.99
0.97
1.00
0.99
0.97
1.00
1.03
1.02
1.04

1.00
0.95
1.05
1.08
1.01
1.13
0.92
0.86
0.96
0.97
0.92
1.02
0.97
0.92
1.02
1.04
0.97
1.09
0.98
0.92
1.02
0.98
0.92
1.02
0.98
0.92
1.02
0.98
0.92
1.02
0.98
0.92
1.02
1.09
1.02
1.15

1.00
1.01
0.99
1.03
1.04
1.02
0.94
0.95
0.93
1.00
1.01
0.99
0.97
0.98
0.96
1.00
1.01
0.99
0.99
1.00
0.98
0.99
1.00
0.98
0.99
1.00
0.98
0.99
1.00
0.98
0.99
1.00
0.98
1.03
1.04
1.02

22-1744-01-1102 (EN)

Performance Data
Cooling
2TWB0042A1
2TWB0042A1 WITH TWE042C14 AT 1400 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
35.5
38.4
41.4
44.5

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
31.0
34.7
36.7*
37.6*
26.1
29.9
33.7
36.3
20.5
24.4
28.2
30.8
14.9
18.7
22.6
25.1

TOTAL
KW
3.57
3.65
3.74
3.83

59
63
67
71

34.7
37.5
40.5
43.6

30.7
25.7
20.2
14.5

34.2
29.6
24.0
18.4

36.1*
33.4
27.9
22.2

37.0*
36.0
30.4
24.8

3.92
3.99
4.07
4.15

59
63
67
71

32.0
34.7
37.4
40.2

29.4
24.4
18.9
13.3

32.5
28.3
22.8
17.1

33.8*
32.1
26.6
20.9

34.7*
34.7*
29.2
23.5

4.22
4.29
4.35
4.42

59
63
67
71

29.3
31.8
34.3
36.9

28.2
23.2
17.7
12.0

30.3
27.1
21.5
15.9

31.5*
30.9
25.3
19.7

32.3*
32.3*
27.9
22.3

4.53
4.58
4.63
4.68

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE048C14

TWE060A

TWG037A14

TWG042A14

TWG048A14

TXA042C4

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1225
1575

0.98
1.01

TXA043C4

0.94
1.05

TXC042C4

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXC043C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TVF036A14
RATED
1400
0.98
0.99
1.01
LOW
1225
0.96
0.93
1.02
HIGH
1575
0.99
1.05
1.00
TWE036C14
RATED
1400
0.95
0.96
0.99
LOW
1225
0.93
0.91
1.00
HIGH
1575
0.96
1.00
0.98
TWE042C14
RATED
1400
1.00
1.00
1.00
LOW
1225
0.98
0.94
1.01
HIGH
1575
1.01
1.05
0.99

22-1744-01-1102 (EN)

TXH041A4

29

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1600
1400
1800
1600
1400
1800
1300
1125
1475
1400
1225
1575
1600
1400
1800
1200
1050
1350
1400
1225
1575
1200
1050
1350
1400
1225
1575
1400
1225
1575

1.01
0.99
1.02
1.02
1.00
1.03
0.93
0.91
0.95
0.94
0.92
0.95
1.01
0.99
1.02
0.95
0.92
0.97
0.97
0.95
0.98
0.95
0.92
0.97
0.97
0.95
0.98
1.00
0.98
1.01

1.06
1.00
1.11
1.05
0.99
1.11
0.92
0.86
0.96
0.93
0.87
0.97
1.06
1.00
1.11
0.90
0.85
0.95
0.96
0.91
1.01
0.90
0.85
0.95
0.96
0.91
1.01
1.00
0.94
1.05

1.03
1.04
1.02
0.98
0.99
0.97
0.96
0.96
0.95
0.96
0.97
0.95
1.02
1.03
1.01
0.95
0.96
0.94
0.98
0.99
0.97
0.95
0.96
0.94
0.98
0.99
0.97
0.99
1.00
0.98

Performance Data
Cooling
2TWB0048A1
2TWB0048A1 WITH TWE048C14 AT 1600 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
39.8
43.2
46.8
50.4

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
35.0
39.2
41.4*
42.5*
29.4
33.8
38.2
41.2
23.0
27.5
31.9
34.9
16.6
21.0
25.5
28.4

TOTAL
KW
4.11
4.22
4.33
4.45

59
63
67
71

38.8
42.1
45.5
49.1

34.5
28.9
22.5
16.1

38.5
33.3
27.0
20.5

40.5*
37.7
31.4
24.9

41.6*
40.7
34.4
27.9

4.48
4.58
4.69
4.80

59
63
67
71

35.8
38.8
42.0
45.3

33.2
27.5
21.1
14.7

36.5
31.9
25.6
19.1

38.0*
36.3
30.0
23.5

39.0*
39.0*
33.0
26.5

4.82
4.92
5.02
5.12

59
63
67
71

32.8
35.6
38.5
41.5

31.8
26.1
19.7
13.3

33.9
30.5
24.2
17.7

35.4*
34.9
28.6
22.2

36.3*
36.3*
31.6
25.1

5.17
5.25
5.34
5.43

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE060C/D15

TWG042A14+TAYTXV-3

TWG048A14

TWG060A15

TXA048C4

TXA049C4

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1400
1800

0.98
1.01

TXC048C4

0.94
1.05

TXC049C4

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXC050C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE042C14
RATED
1600
0.97
0.97
0.99
LOW
1400
0.95
0.91
1.00
HIGH
1800
0.98
1.02
0.98
TWE048C14
RATED
1600
1.00
1.00
1.00
LOW
1400
0.98
0.94
1.01
HIGH
1800
1.01
1.05
0.99
TWE060A
RATED
1800
1.03
1.05
0.98
LOW
1575
1.01
0.99
0.99
HIGH
2025
1.04
1.10
0.97

TXH054A4

30

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1800
1575
2025
1500
1300
1700
1600
1400
1800
1800
1575
2025
1400
1225
1575
1600
1400
1800
1400
1225
1575
1600
1400
1800
1600
1400
1800
1700
1475
1925

1.04
1.03
1.05
0.94
0.92
0.95
0.99
0.97
1.00
1.04
1.02
1.05
0.97
0.94
0.98
0.99
0.97
1.01
0.97
0.94
0.98
0.99
0.97
1.01
0.99
0.97
1.01
1.06
1.03
1.07

1.07
1.00
1.12
0.90
0.85
0.94
0.99
0.93
1.04
1.07
1.00
1.12
0.92
0.87
0.98
0.98
0.92
1.04
0.92
0.87
0.98
0.98
0.92
1.04
0.98
0.92
1.04
1.08
1.01
1.15

1.06
1.08
1.05
0.95
0.96
0.94
0.98
0.99
0.97
1.04
1.05
1.03
0.95
0.96
0.94
0.98
0.99
0.97
0.95
0.96
0.94
0.98
0.99
0.97
0.98
0.99
0.97
1.02
1.03
1.01

22-1744-01-1102 (EN)

Performance Data
Cooling
2TWB0060A1
2TWB0060A1 WITH TWE060C/D15 AT 1900 CFM
O.D.
D.B.
85

95

105

115

I.D.
W.B.
59
63
67
71

TOT.
CAP.
52.9
57.2
61.6
66.2

SENS. CAP. AT ENTERING D.B. TEMP.


72
75
78
80
43.4
48.7
53.3*
54.7*
36.7
41.9
47.1
50.6
29.1
34.4
39.6
43.1
21.4
26.7
31.9
35.4

TOTAL
KW
5.58
5.72
5.87
6.02

59
63
67
71

50.5
54.6
58.8
63.2

42.3
35.5
28.0
20.3

47.6
40.8
33.3
25.6

51.4*
46.0
38.4
30.7

52.7*
49.4
41.9
34.2

6.07
6.20
6.35
6.49

59
63
67
71

47.4
51.2
55.2
59.3

40.9
34.1
26.6
18.9

46.0
39.3
31.8
24.1

48.9*
44.5
37.0
29.3

50.1*
48.0
40.5
32.8

6.57
6.69
6.82
6.96

59
63
67
71

44.3
47.9
51.6
55.5

39.4
32.6
25.1
17.4

44.0
37.9
30.4
22.7

46.3*
43.1
35.6
27.9

47.4*
46.6
39.0
31.4

7.08
7.19
7.30
7.42

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE060C/D15

TWG048A14

TWG060A15

TXA060C5

TXA061C5

TXC060C5

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1650
2150

0.98
1.01

TXC061C5

0.94
1.05

TXH063P3-A

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

TXH063P3-B

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH MBTUH SYST
INDOOR MODEL
CFM
TOT
SEN
KW
TWE042C14
RATED
1600
0.92
0.90
0.93
LOW
1400
0.89
0.85
0.94
HIGH
1800
0.94
0.94
0.92
TWE048C14
RATED
1800
0.98
0.98
0.97
LOW
1575
0.96
0.93
0.98
HIGH
2025
1.00
1.02
0.96
TWE060A
RATED
2000
1.00
1.01
0.95
LOW
1750
0.98
0.96
0.96
HIGH
2250
1.01
1.06
0.94

22-1744-01-1102 (EN)

31

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1900
1650
2150
1600
1400
1800
2000
1750
2250
1700
1475
1925
1800
1575
2025
1700
1475
1925
1800
1575
2025
2000
1750
2250
2000
1750
2250

1.00
0.98
1.01
0.94
0.91
0.96
1.02
1.00
1.03
0.99
0.96
1.01
1.01
0.99
1.03
0.99
0.96
1.01
1.01
0.99
1.03
1.06
1.04
1.07
1.07
1.05
1.08

1.00
0.94
1.05
0.92
0.87
0.96
1.04
0.98
1.09
0.95
0.89
1.00
1.00
0.95
1.05
0.95
0.89
1.00
1.00
0.95
1.05
1.10
1.03
1.16
1.11
1.04
1.18

1.00
1.01
0.99
0.93
0.94
0.92
1.01
1.02
1.00
0.95
0.96
0.94
0.96
0.97
0.95
0.95
0.96
0.94
0.96
0.97
0.95
0.99
1.00
0.98
1.00
1.01
0.99

Performance Data
Heating
2TWB0012A1
2TWB0012A1 WITH TWE018C14 AT 400 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
4.20
4.14
4.08
5.33
5.26
5.18
6.47
6.37
6.27
7.60
7.49
7.37
8.51
8.38
8.25
9.41
9.27
9.12
10.32
10.16
10.00
11.22
11.05
10.88
12.13
11.94
11.75
14.40
14.18
13.95
15.53
15.29
15.05
16.67
16.41
16.15
17.80
17.52
17.25
18.93
18.64
18.34
20.07
19.75
19.44

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
0.96
0.99
1.01
1.02
1.04
1.06
1.07
1.10
1.12
1.13
1.15
1.18
1.18
1.20
1.23
1.23
1.26
1.29
1.28
1.31
1.34
1.34
1.37
1.40
1.39
1.42
1.45
1.45
1.48
1.51
1.50
1.53
1.57
1.55
1.59
1.63
1.61
1.64
1.68
1.66
1.70
1.74
1.71
1.75
1.79

TWE018C14

TWG018A14

TWG025A14

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

400
350
450
450
400
500
450
400
500

1.00
0.99
1.01
0.99
0.98
1.00
1.00
0.99
1.01

1.00
0.99
1.02
1.00
0.99
1.02
0.99
0.98
1.01

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

350
450

0.99
1.01

1.02
0.99

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF018A14
RATED
450
1.01
0.96
LOW
400
1.00
0.95
HIGH
500
1.03
0.98
TVF024A14
RATED
450
1.04
1.03
LOW
400
1.03
1.02
HIGH
500
1.05
1.05
TVF025A14
RATED
450
1.03
1.01
LOW
400
1.02
1.00
HIGH
500
1.04
1.03

32

22-1744-01-1102 (EN)

Performance Data
Heating
2TWB0018A1
2TWB0018A1 WITH TWE018C14 AT 600 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
5.05
4.98
4.91
6.30
6.21
6.12
7.55
7.44
7.33
8.80
8.67
8.54
9.42
9.28
9.14
10.03
9.88
9.74
10.65
10.49
10.33
11.26
11.10
10.93
11.88
11.70
11.52
16.30
16.06
15.81
17.55
17.29
17.02
18.80
18.52
18.23
20.05
19.75
19.44
21.30
20.98
20.66
22.55
22.21
21.87

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
1.14
1.17
1.20
1.18
1.21
1.24
1.22
1.25
1.28
1.26
1.30
1.33
1.31
1.34
1.38
1.36
1.39
1.43
1.40
1.44
1.48
1.45
1.49
1.52
1.50
1.54
1.57
1.51
1.55
1.59
1.55
1.59
1.63
1.59
1.63
1.68
1.64
1.68
1.72
1.68
1.72
1.76
1.72
1.76
1.81

TWE024C14

TWG018A14

TWG025A14

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)


AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

525
675

0.99
1.01

1.02
0.99

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF018A14
RATED
600
1.01
0.99
LOW
525
1.00
0.98
HIGH
675
1.02
1.01
TVF024A14
RATED
700
1.04
1.03
LOW
600
1.02
1.02
HIGH
800
1.05
1.05
TWE018C14
RATED
600
1.00
1.00
LOW
525
0.99
0.99
HIGH
675
1.01
1.02

22-1744-01-1102 (EN)

33

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

700
600
800
600
525
675
700
600
800

1.02
1.00
1.03
0.99
0.98
1.00
1.02
1.00
1.03

1.06
1.05
1.08
1.03
1.02
1.05
1.03
1.02
1.05

Performance Data
Heating
2TWB0024A1
2TWB0024A1 WITH TWE024C14 AT 800 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
9.75
9.62
9.48
11.20
11.04
10.89
12.65
12.47
12.29
14.10
13.90
13.70
14.51
14.30
14.09
14.91
14.70
14.49
15.32
15.10
14.88
15.73
15.50
15.28
16.13
15.90
15.67
22.80
22.47
22.14
24.25
23.90
23.54
25.70
25.33
24.95
27.15
26.75
26.36
28.60
28.18
27.76
30.05
29.61
29.17

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
1.70
1.74
1.77
1.76
1.80
1.84
1.83
1.87
1.91
1.90
1.94
1.98
1.93
1.97
2.01
1.96
2.01
2.05
2.00
2.04
2.08
2.03
2.07
2.12
2.06
2.11
2.15
2.29
2.34
2.39
2.35
2.41
2.46
2.42
2.47
2.53
2.48
2.54
2.60
2.55
2.61
2.67
2.62
2.68
2.73

TWE018C14

TWE024C14

TWE030C14

TWG018A14

TWG025A14

TWG030A14
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

700
900

0.99
1.01

TXA024C4

1.02
0.99

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXA025C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF018A14
RATED
700
1.00
0.98
LOW
600
0.98
0.96
HIGH
800
1.01
1.00
TVF024A14
RATED
800
1.02
0.98
LOW
700
1.01
0.97
HIGH
900
1.03
1.00
TVF025A14
RATED
800
1.00
0.96
LOW
700
0.99
0.95
HIGH
900
1.01
0.98
TVF030A14
RATED
900
1.03
0.96
LOW
775
1.02
0.95
HIGH
1025
1.04
0.98

TXC024C4

TXC024D4

TXC025C4

TXC025D4

TXH025A4

34

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

700
600
800
800
700
900
900
775
1025
700
600
800
800
700
900
900
775
1025
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900
800
700
900

0.97
0.95
0.98
1.00
0.99
1.01
1.02
0.99
1.03
0.97
0.95
0.98
1.00
0.99
1.01
1.01
0.99
1.02
1.00
0.99
1.01
1.01
1.00
1.02
1.00
0.99
1.01
1.00
0.99
1.01
1.01
1.00
1.02
1.01
1.00
1.02
1.00
0.99
1.01

0.99
0.97
1.01
1.00
0.99
1.02
0.98
0.97
1.00
1.00
0.98
1.02
0.98
0.97
1.00
1.00
0.99
1.02
1.01
1.00
1.03
0.98
0.97
1.00
1.01
1.00
1.03
1.01
1.00
1.03
0.98
0.97
1.00
0.98
0.97
1.00
1.01
1.00
1.03

22-1744-01-1102 (EN)

Performance Data
Heating
2TWB0030A1
2TWB0030A1 WITH TWE030C14 AT 1000 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
12.15
12.02
11.88
13.87
13.71
13.56
15.58
15.41
15.23
17.30
17.10
16.91
18.20
17.99
17.78
19.09
18.88
18.66
19.99
19.76
19.53
20.89
20.65
20.41
21.78
21.53
21.28
27.60
27.28
26.96
29.32
28.98
28.63
31.03
30.67
30.31
32.75
32.37
31.98
34.47
34.06
33.66
36.18
35.76
35.33

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
2.12
2.17
2.22
2.18
2.23
2.28
2.24
2.29
2.35
2.30
2.36
2.41
2.34
2.40
2.45
2.38
2.43
2.49
2.41
2.47
2.53
2.45
2.51
2.57
2.48
2.54
2.60
2.68
2.74
2.81
2.74
2.81
2.87
2.80
2.87
2.94
2.87
2.94
3.01
2.93
3.00
3.07
2.99
3.06
3.14

TWE030C14

TWE036C14

TWG025A14

TWG030A14

TWG036A14

TXA030C4
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

875
1125

0.99
1.01

TXA031C4

1.02
0.98

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXC030C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF024A14
RATED
800
0.98
0.99
LOW
700
0.97
0.97
HIGH
900
0.99
1.01
TVF025A14
RATED
900
0.99
1.00
LOW
775
0.97
0.98
HIGH
1025
1.00
1.02
TVF030A14
RATED
1000
1.00
0.97
LOW
875
0.99
0.96
HIGH
1125
1.01
0.99
TVF036A14
RATED
1100
1.02
0.99
LOW
950
1.01
0.98
HIGH
1250
1.03
1.01
TWE024C14
RATED
900
0.95
1.02
LOW
775
0.93
1.00
HIGH
1025
0.96
1.04

22-1744-01-1102 (EN)

TXC030D4

TXC031C4

TXC031D4

TXH025A4

TXH033A4

35

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1000
875
1125
1100
950
1250
900
775
1025
1000
875
1125
1100
950
1250
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
1000
875
1125
900
775
1025
1000
875
1125

1.00
0.99
1.01
1.00
0.99
1.01
0.96
0.95
0.97
0.97
0.96
0.98
0.99
0.98
1.00
0.99
0.98
1.00
1.00
0.99
1.01
0.99
0.98
1.00
0.99
0.98
1.00
1.00
0.99
1.01
1.00
0.99
1.01
0.96
0.94
0.97
1.00
0.99
1.01

1.00
0.98
1.02
0.99
0.97
1.01
0.99
0.97
1.01
1.00
0.98
1.02
0.99
0.97
1.01
1.01
0.99
1.03
0.99
0.98
1.01
1.01
0.99
1.03
1.01
0.99
1.03
0.99
0.98
1.01
0.99
0.98
1.01
1.02
1.00
1.04
0.99
0.98
1.01

Performance Data
Heating
2TWB0036A1
2TWB0036A1 WITH TWE036C14 AT 1200 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
12.15
12.02
11.89
14.40
14.24
14.09
16.65
16.47
16.28
18.90
18.69
18.48
19.38
19.17
18.95
19.87
19.65
19.42
20.35
20.13
19.90
20.84
20.60
20.37
21.32
21.08
20.84
32.40
32.03
31.65
34.65
34.25
33.85
36.90
36.47
36.04
39.15
38.69
38.24
41.40
40.92
40.43
43.65
43.14
42.63

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
2.35
2.41
2.46
2.44
2.50
2.56
2.52
2.59
2.65
2.61
2.68
2.75
2.67
2.74
2.81
2.73
2.80
2.87
2.78
2.85
2.93
2.84
2.91
2.99
2.90
2.97
3.05
3.14
3.23
3.31
3.23
3.32
3.40
3.32
3.41
3.50
3.41
3.50
3.59
3.50
3.59
3.69
3.59
3.68
3.78

TWE036C14

TWE042C14

TWG030A14

TWG036A14

TWG037A14

TWG042A14
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1050
1350

0.99
1.01

TXA036C4

1.02
0.98

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXA037C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF030A14
RATED
1100
0.99
1.00
LOW
950
0.98
0.98
HIGH
1250
1.00
1.02
TVF036A14
RATED
1200
1.00
1.00
LOW
1050
0.99
0.99
HIGH
1350
1.01
1.02
TWE030C14
RATED
900
0.94
1.00
LOW
775
0.92
0.98
HIGH
1025
0.95
1.02

TXC036C4

TXC036D4

TXC037C4

TXH041A4

36

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1200
1050
1350
1400
1225
1575
1100
950
1250
1200
1050
1350
1200
1050
1350
1400
1225
1575
1200
1050
1350
1200
1050
1350
1200
1050
1350
1200
1050
1350
1200
1050
1350
1400
1225
1575

1.00
0.99
1.01
1.01
1.00
1.02
0.96
0.95
0.97
0.99
0.98
1.00
0.97
0.96
0.98
1.00
0.99
1.01
1.00
0.99
1.01
1.00
0.99
1.01
1.00
0.99
1.01
1.00
0.99
1.01
1.00
0.99
1.01
1.02
1.01
1.03

1.00
0.98
1.02
1.01
1.00
1.03
1.02
1.00
1.04
1.04
1.02
1.06
1.01
0.99
1.03
1.01
1.00
1.03
0.99
0.98
1.01
0.99
0.98
1.01
0.99
0.98
1.01
0.99
0.98
1.01
0.99
0.98
1.01
1.00
0.99
1.02

22-1744-01-1102 (EN)

Performance Data
Heating
2TWB0042A1
2TWB0042A1 WITH TWE042C14 AT 1400 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
15.60
15.38
15.17
18.20
17.94
17.68
20.80
20.50
20.20
23.40
23.06
22.72
24.30
23.95
23.60
25.21
24.84
24.47
26.11
25.73
25.34
27.01
26.62
26.22
27.91
27.50
27.09
39.00
38.42
37.83
41.60
40.97
40.35
44.20
43.53
42.87
46.80
46.09
45.39
49.40
48.65
47.90
52.00
51.21
50.42

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
2.63
2.70
2.77
2.73
2.80
2.87
2.83
2.91
2.98
2.93
3.01
3.09
3.00
3.08
3.16
3.07
3.15
3.23
3.14
3.22
3.31
3.21
3.30
3.38
3.28
3.37
3.46
3.53
3.62
3.72
3.63
3.73
3.83
3.73
3.83
3.93
3.83
3.93
4.04
3.93
4.03
4.14
4.02
4.14
4.25

TWE048C14

TWE060A

TWG037A14

TWG042A14

TWG048A14

TXA042C4
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1225
1575

0.98
1.01

TXA043C4

1.02
0.98

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXC042C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TVF036A14
RATED
1400
1.01
1.02
LOW
1225
0.99
1.00
HIGH
1575
1.02
1.04
TWE036C14
RATED
1400
0.98
1.03
LOW
1225
0.96
1.01
HIGH
1575
0.99
1.05
TWE042C14
RATED
1400
1.00
1.00
LOW
1225
0.98
0.98
HIGH
1575
1.01
1.02

TXC043C4

22-1744-01-1102 (EN)

TXH041A4

37

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1600
1400
1800
1600
1400
1800
1300
1125
1475
1400
1225
1575
1600
1400
1800
1200
1050
1350
1400
1225
1575
1200
1050
1350
1400
1225
1575
1400
1225
1575

1.02
1.01
1.03
1.00
0.99
1.01
0.96
0.94
0.97
0.98
0.96
0.99
1.01
1.00
1.02
0.98
0.97
0.99
1.00
0.99
1.01
0.98
0.97
0.99
1.00
0.99
1.01
1.00
0.99
1.01

1.01
0.99
1.03
0.96
0.94
0.98
1.03
1.01
1.05
1.01
0.99
1.03
1.00
0.98
1.02
0.99
0.97
1.01
1.00
0.98
1.02
0.99
0.97
1.01
1.00
0.98
1.02
0.99
0.97
1.01

Performance Data
Heating
2TWB0048A1
2TWB0048A1 WITH TWE048C14 AT 1600 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
14.05
13.87
13.70
17.43
17.21
16.98
20.82
20.54
20.26
24.20
23.87
23.55
25.13
24.79
24.45
26.06
25.70
25.35
26.99
26.62
26.25
27.92
27.53
27.15
28.84
28.45
28.05
44.50
43.87
43.25
47.88
47.21
46.53
51.27
50.54
49.81
54.65
53.87
53.09
58.03
57.21
56.38
61.42
60.54
59.66

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
2.82
2.89
2.96
2.96
3.03
3.10
3.09
3.17
3.24
3.22
3.30
3.39
3.31
3.40
3.48
3.40
3.49
3.57
3.49
3.58
3.67
3.57
3.67
3.76
3.66
3.76
3.85
4.02
4.13
4.24
4.16
4.27
4.38
4.29
4.41
4.52
4.43
4.54
4.66
4.56
4.68
4.80
4.69
4.82
4.95

TWE060C/D15

TWG042A14+TAYTXV-3

TWG048A14

TWG060A15

TXA048C4

TXA049C4
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1400
1800

0.99
1.01

TXC048C4

1.02
0.98

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXC049C4

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TWE042C14
RATED
1600
0.97
1.03
LOW
1400
0.95
1.01
HIGH
1800
0.98
1.05
TWE048C14
RATED
1600
1.00
1.00
LOW
1400
0.99
0.98
HIGH
1800
1.01
1.02
TWE060A
RATED
1800
0.97
0.96
LOW
1575
0.96
0.95
HIGH
2025
0.98
0.98

TXC050C4

TXH054A4

38

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1800
1575
2025
1500
1300
1700
1600
1400
1800
1800
1575
2025
1400
1225
1575
1600
1400
1800
1400
1225
1575
1600
1400
1800
1600
1400
1800
1700
1475
1925

1.01
0.99
1.02
0.95
0.93
0.96
0.98
0.97
0.99
1.01
0.99
1.02
0.97
0.96
0.98
0.98
0.97
0.99
0.97
0.96
0.98
0.98
0.97
0.99
0.98
0.97
0.99
1.00
0.99
1.01

1.04
1.03
1.06
1.02
0.99
1.04
1.01
0.99
1.03
1.01
1.00
1.03
0.98
0.96
1.00
0.98
0.96
1.00
0.98
0.96
1.00
0.98
0.96
1.00
0.98
0.96
1.00
0.98
0.97
1.00

22-1744-01-1102 (EN)

Performance Data
Heating
2TWB0060A1
2TWB0060A1 WITH TWE060C/D15 AT 1900 CFM
O.D.
TEMP.
F.
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72

HEATING CAPACITY MBH AT


INDOOR DRY BULB TEMP.
70
75
80
22.70
22.47
22.24
26.50
26.22
25.95
30.29
29.98
29.66
34.09
33.73
33.36
35.10
34.72
34.35
36.10
35.72
35.33
37.11
36.71
36.31
38.12
37.71
37.30
39.13
38.70
38.28
56.86
56.23
55.60
60.66
59.98
59.31
64.45
63.73
63.01
68.25
67.48
66.72
72.04
71.23
70.42
75.84
74.98
74.13

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW

TOTAL POWER IN KILOWATTS AT


INDOOR DRY BULB TEMP.
70
75
80
3.72
3.80
3.89
3.90
3.99
4.08
4.09
4.18
4.28
4.27
4.37
4.48
4.42
4.53
4.63
4.57
4.68
4.79
4.72
4.84
4.95
4.87
4.99
5.11
5.02
5.15
5.27
5.38
5.52
5.65
5.57
5.71
5.85
5.75
5.90
6.04
5.94
6.09
6.24
6.12
6.28
6.43
6.31
6.47
6.63

TWE060C/D15

TWG048A14

TWG060A15

TXA060C5

TXA061C5

TXC060C5
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW
TOTAL CAPACITY
SENSIBLE CAPACITY
LOW
HIGH

1650
2150

0.99
1.01

TXC061C5

1.02
0.98

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.

TXH063P3-A

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)


MBTUH SYST
INDOOR MODEL
CFM
TOT
KW
TWE042C14
RATED
1600
0.94
1.00
LOW
1400
0.93
0.98
HIGH
1800
0.95
1.02
TWE048C14
RATED
1800
0.97
0.99
LOW
1575
0.96
0.97
HIGH
2025
0.98
1.01
TWE060A
RATED
2000
0.96
0.94
LOW
1750
0.95
0.92
HIGH
2250
0.97
0.96

TXH063P3-B

22-1744-01-1102 (EN)

39

RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH
RATED
LOW
HIGH

1900
1650
2150
1600
1400
1800
2000
1750
2250
1700
1475
1925
1800
1575
2025
1700
1475
1925
1800
1575
2025
2000
1750
2250
2000
1750
2250

1.00
0.99
1.01
0.94
0.93
0.95
0.99
0.98
1.00
0.97
0.96
0.98
0.97
0.96
0.98
0.97
0.96
0.98
0.97
0.96
0.98
0.99
0.98
1.00
0.99
0.98
1.00

1.00
0.98
1.02
0.98
0.96
1.00
0.99
0.97
1.01
0.95
0.93
0.97
0.95
0.93
0.97
0.95
0.93
0.97
0.95
0.93
0.97
0.94
0.93
0.96
0.94
0.93
0.96

Electrical
Data

SCHEMATIC DIAGRAMS
(SEE LEGEND)

2TWB0012-048A

2TWB0060A

40

22-1744-01-1102 (EN)

Electrical
Data

SCHEMATIC DIAGRAMS
LEGEND

SYMBOL

22-1744-01-1102 (EN)

41

Dimensions
2TWB0 OUTLINE DRAWING
Note: All dimensions are in MM (Inches).

MODELS

BASE FIG.

K
457 (18)

2TWB0012A

651 (25-5/8)

724 (28-1/2)

651 (25-5/8)

5/8

1/4

127 (5)

57 (2-1/4)

181 (7-1/8)

44 (1-3/4)

2TWB0018A

651 (25-5/8)

724 (28-1/2)

651 (25-5/8)

5/8

1/4

127 (5)

57 (2-1/4)

181 (7-1/8)

44 (1-3/4)

457 (18)

2TWB0024A

651 (25-5/8)

724 (28-1/2)

651 (25-5/8)

3/4

5/16

127 (5)

57 (2-1/4)

181 (7-1/8)

44 (1-3/4)

457 (18)

2TWB0030A

730 (28-3/4)

724 (28-1/2)

651 (25-5/8)

3/4

5/16

137 (5-3/8)

65 (2-5/8)

210 (8-1/4)

57 (2-1/4)

457 (18)

2TWB0036A

730 (28-3/4)

724 (28-1/2)

651 (25-5/8)

7/8

3/8

137 (5-3/8)

65 (2-5/8)

210 (8-1/4)

57 (2-1/4)

457 (18)

2TWB0042A

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

7/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

2TWB0048A

832 (32-3/4)

829 (32-5/8)

756 (29-3/4)

1-1/8

3/8

143 (5-5/8)

92 (3-5/8)

210 (8-1/4)

79 (3-1/8)

508 (20)

2TWB0060A

841 (33-1/8)

946 (37-1/4)

870 (34-1/4)

1-1/8

3/8

152 (6)

98 (3-7/8)

219 (8-5/8)

86 (3-3/8)

508 (20)

From Dwg. 21D153074 Rev. 6


42

22-1744-01-1102 (EN)

Mechanical
Specification Options

General
The 2TWB0 is fully charged from the
factory for up to 15 feet of piping. This
unit is designed to operate at outdoor
ambient temperatures as high as 115F.
Cooling capacities are matched with a
wide selection of air handlers and
furnace coils that are A.R.I. certified. The
unit is UL listed. Exterior is designed for
outdoor application.
Casing
Unit casing is constructed of heavy
gauge, G90 galvanized steel and painted
with a weather-resistant powder paint
on all louvers, panels, prepaint on all
other panels. Corrosion and weatherproof CMBP-G30 DuraTuff base.
Refrigerant Controls
Refrigeration system controls include
condenser fan, compressor contactor
and high pressure switch. High and low
pressure controls are inherent to the
compressor. A factory installed liquid line
drier is standard.
Compressor
The Climatuff compressor features a
5 year limited warranty, internal over
temperature and pressure protection
and total dipped hermetic motor. Other
features include: roto lock suction and
discharge refrigerant connections,
centrifugal oil pump and low vibration
and noise.

22-1744-01-1102 (EN)

43

Condenser Coil
The outdoor coil provides low airflow
resistance and efficient heat transfer.
The coil is protected on all four sides by
louvered panels and has a 5 year
limited warranty.
Low Ambient Cooling
As manufactured, this unit has a cooling
capability to 55F. The addition of an
evaporator defrost control permits
operation to 40 F. The addition of an
evaporator defrost control with TXV
permits low ambient cooling to 30 F.
Accessories
Thermostats Cooling only and
heat/cooling (manual and automatic
changeover). Sub-base to match thermostat and locking thermostat cover.
Evaporator Defrost Control See Low
Ambient Cooling.

Trane
A business of
American Standard Companies
www.trane.com

Literature Order Number

SSP-PRC008-EN

File Number

Supersedes

New

Stocking Location

PI Louisville & Webb/Mason-Houston 11/02

Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.

P.I.