General information nformation / preparation

Setting up the network c configuration onfiguration and parameters

Quick Guide to
CPX-FB13 FB13 Profibus Profibus-DP connected to various PLC like: S7-300

GSD available at www.festo.com/fieldbus GSD with parameters for CPX modules and valve terminals Documentations with detailed descriptions available at www.festo.com (Automation -> Documentation) Search for: CPX-FB13 (Profibus-DP manual): EN - 526428 CPX-SYS (CPX system manual): EN - 526446

1
Busaddress 1 125

Start-up hardware settings ettings


Operating Mode: Remote I/O No function, reserved

Using STEP7 for Profibus Hardware configuration

binary coded

3
1. 2. 3.

Configuration with STEP7

Using LEDs for the identification dentification of device status

Profibus Profibus-DP network status


Copy the GSD of the valve terminal into the directory ...\STEP7 STEP7\S7Data\GSD on your PC/programmer. Copy the icon files for the CPX terminal into directory ...\STEP7 STEP7\S7DATA\NSBMP on your PC or programmer. Insert a DP master system: - Righthand mouse click on "DP "under "CPU".

Bus Failure

Ok Field bus connection isnt ok

4. Open the following folder in the hardware catalogue: "\PROFIBUS PROFIBUSDP\Additional Field devices\Valves". Valves". Pull the station type "FESTO CPXTerminal" Terminal" onto the line of f the DP master system system. The dialogue window "Properties Properties _ PROFIBUS interface" will be displayed. 5. 6. 7. Select the PROFIBUS address identical to the selected setting on the DIL switch. switch Open the module "FESTO FESTO CPX CPXTerminal"(folder\PROFIBUS PROFIBUSDP\Additional Field Devices\Valves\...) in the hardw hardware catalogue. hand) module of your CPX terminal onto line 0 in the Pull the first (lefthand) configuration table. Repeat this step with further modules of your CPX terminal. terminal

CPX hardware status System failure OK Information Diagnostic Hardware defect Power OK Outside tolerance OK Saved parameters Force active

Power system / load Modify status

See manual CPX-FB13 FB13 chapter Commissioning Commissioning for more details
Festo AG & Co KG Quick Guide to CPX-FB13 FB13/Various PLC

Version A2 A

Tip

Mapping

Tip

Alternative diagnose

The Status bits are 8 major signals which can be considered inside the PLC program. They are accessed via the optional Strobed connection Bit Diagnostic information Description ---------------------------------------------------------------------------------------------0 Fault at valve Module type on which 1 Fault at output a fault has occurred 2 Fault at input 3 Fault on analogue/function module ---------------------------------------------------------------------------------------------4 Under voltage Type of fault 5 Short circuit/overload 6 Wire fracture/open load 7 Other faults ---------------------------------------------------------------------------------------------Additional and advanced diagnostics can be read out with: - Online-Mode of S7 - Handheld unit CPX-MMI - USB adapter/ Ethernet with CPX-FMT software See manual CPX-FB13 chapter Diagnosis for more details

Location Module

DP identifier Siemens 0 Field bus node (FB13) 64 1 Digital 8-input module 8DI 2 Digital 8-input module 8DI 3 Digital 4-output module 4DO 4 Digital multi I/O module 8DX 5 Digital 4-output module 4 DO 6 CPA pneumatic Interface 16DO *) Identifiers can be grouped together

Input address 42 43 44 45 -

Output address 42 43 (42)* 44

See manual CPX-FB13 chapter Commissioning for more details

Tip

Installation
Screening - Correct screening at each connector - The cable screen should be connected to ground at both ends of the cable

Tip

Changing GSD size

The GSD file size is around 220KB. Some PLC memory cards have in total only 256KB. It could happen that the size of the GSD file is too big. In order to decrease the size proceed according follow steps. 1. Open GSD file e.g. CPX_059.GSD with an Editor 2. Scroll down to Modultypen

Potential equalization The cross-section of the potential equalization cable should be chosen with regard to the maximum potential equalization currents which can flow.

3. Mark the modules which are not needed (e.g. CPI modules)

Note: A good Installation is necessary for a trouble-free operation

4. Delete and save the file

Tip

IDLE and Fault Mode

Tip
Diagnostics

Diagnostic integration

FAULT mode: Defines the status of output signals during a network failure when connected to a running PLC The default setup defines all output signals to the OFF state during one of the modes An optional channel based setup can be made: Value to OFF (default) Value to ON Hold Last State

-Diagnostic data and parameters are usually also integrated into the GSD files and are read out in online mode of configuration tools like Step7 or can be interpreted by PLCs. -16 pre-defined failure types. -Advanced diagnostics may be Integrated into the PLC with the use of OB82 and OB86 function blocks. Diagnostic information is structured in - Device oriented diagnostic - Module oriented diagnostic - Channel oriented diagnostic See manual CPX-FB13 chapter Diagnosis for more details

Festo AG & Co KG

Quick Guide to CPX-FB13/Various PLC

Version A2