Regulating structure
Qstruc
Qstruc is a function of Q or h
Qstruc f J 2 J 1
Qstruc Q t
Qstruc
H2
J Qstruc f H Q J2 1 2 dummy
Where J2 = H2
H 1
Qdummy 1
Where J1 = Qdummy
MIKE 11 implementation
Specification Specify and Location of location f(J2). of type: Linear control points interpolation type of and Function of used control at points time intermediate values Function of water level and/or discharge in control point Overview of regulating structures
Pumps
Internal outlet: The flow is applied at the Qpoint
Q-points
External outlet: The flow is applied at the Hpoint. Water leaves the system
Qpump
Qpump
H-points
Pumps
Control parameters: Start level - Water level at which the pump initiates Stop level - Water level at which the pump stops
Start-up period: Warm up period - linear variation in Q Close down period: Shut down period - linear variation in Q X-sec
positive chainage
Pumps
Pump data: Const discharge - Pump operates at constant rate Q/DH - Pumping according to characteristics
DH
DH= Hup-max(Hdown,Houtlet)
External: Hdown=Houtlet
X-sec
positive chainage
Pumps- GUI
Location: Internal: not at an H-point External: at an H-point
Control parameters: Start/stop levels, Start and stop periods Pump data: internal/external, Type, Q/dh table
Tabulated structure
hus
Qstruc
hds
The flow is governed by a relation Q=f(hus, hds) which is tabulated by the user. Note that due to the interpolation methods used a minimum of 4 rows and 4 columns MUST be present
Implementing in MIKE 11
Actual Table tablulated function Specify location by parameters river/branch name No of columns and chainage. Give No structure of rows an ID The structure ID only Water level Important for identifying datum post simulation results Discharge Calculation mode factor - the water level (up/down) may also Overview of all tabulated structures in beset-up tabulated