HAZARD AND OPERABILITY REVIEW

Project name: Process : Section : Item Distillati on column (T-300)

Advance Process Control and Distillation Column Unit Distillation unit (figure.) Distillation Study node Overhea d condens er (E404) unit (figure) Process Deviation parameters s Flow Other flow Possible causes Leakage into the condenser (cooling into the system)

Date :

Page :

Reference drawing : Possible consequences Cooling water leaks into the condenser potentially damaging the reflux drum

Action i.Ensure that FT water is correctly dosed to maintained corrosion. ii.Regularly maintenance and inspection Automatic controller protection is required to be installed in order to protect the condenser ? tba

Temperature High Water spray failure Lack of water spray can allow steam to reach very high temperature and after short period of time, will eventually damaged Condenser will be trip and not functioning and can cause economic consequences Potentially damage to condenser

Pressure Low Loss pressure control due to failure of dump valve

High Loss of cooling water to condenser

Leave the condenser operate at lower acceptable pressure and release some pressure by controlling PT