Вы находитесь на странице: 1из 10

CFD REPORT: INPUT:

cooling water at 300 m3/hr


Goal Name Water Inlet Average Static Pressure Water Outlet Average Static Pressure Average Static Pressure Drop of Tip Water Inlet Average temperature Water Outlet Average temperature Average outside Surface temperature Average Velocity Throughout Tip Value 7.0 6.21 0.79 20.05 20.20 27.3 4.9 Unit Bar Bar Bar C C C m/s

Image 1: Inlet Boundary Condition

Image2: Outlet Boundary Condition

Image 3: Solid Temp Cut Plot Front Section

Image 4: Velocity Plot Front Section

Image 5: Velocity Plot Top Section

Image 6: Solid Temp Cut Plot Top Section 1

Image 7: Solid Temp Cut Plot Top Section 2

Image 8: Solid Temp Outer Surface Bottom View

Image 9: Solid Temp Outer Surface Left Side View

Image 10: Solid Temp Outer Surface Front View