Vibration report for the vapor compressor of desalination unit B (59ML04B-MJ01)

Vibration survey done for the vapor compressor of desalination unit B Tag n#:59ML04B-MJ01. The compressor have deep grove ball bearing FAG 6228M-C3 for drive end side and non-drive end side. Vapor compressor bearing housing Average temp. 35 C The last 2 lubrication PM were cancelled (the last time the lubricant oil changed about one year ago.) Unusual vibration behavior was noted through the survey in the compressor bearing housing, this behavior related to the drive end bearing fault frequencies. Outer Race defect frequency or Inner Race defect frequency or a multiple of either defect frequency found in the vibration spectrum On Inboard Bearing. In the report: Vibration velocity spectrums of the compressor drive end Vibration velocity time waveforms of the compressor drive end Vibration Spike Energy spectrum of the compressor drive end Vibration Spike Energy trend of the compressor drive end Vibration velocity spectrum Comparison between the compressor of Desalination A and compressor of desalination B at the same position and direction. Vibration velocity time waveform Comparison between the compressor of Desalination A and compressor of desalination B at the same position and direction.

Vibration velocity spectrum of the compressor drive end in the vertical direction

B*BPOR: Bearing Outer Ring Pass frequency Vibration velocity time waveforms of the compressor drive end

Vibration Spike Energy spectrum and trend of the compressor drive end

B*BPIR: Bearing Inner Ring Pass frequency

Vibration velocity spectrum Comparison between the compressor of Desalination A and compressor of desalination B at comp. drive end side

Vibration velocity

time waveform Comparison between the compressor of Desalination A and compressor of desalination B at comp.drive end side

Вам также может понравиться