4.5 Drilled panes
8 Retention points
The diameter of drilled holes in panes shall be not less than
Depending on the production process used by the manufac
their thickness.
turer,lt may stili be possible to see where glass has been held
in position. These points of retention shall preferably be
Ja6le 4. Hole diameter
located on one of the shorter sides.
.
,-
Nominal diameter
.
...
Umit deviations
4 to 20 1
..
'lip-to ''',00
-
2
Over'1oo Manufacturer to be consulted.
s Texture
In cast glass with a linear texture, the lines shall be parallel to
the long edge of the glass unless otherwise agreed.
10 Anisotropy
if, under certain conditions, toughened glass is looked at in
,
polarized. light, polarization fields may be visible, the pattern
5 Designation , they produce on the glass'being characteristic of toughened
Designation of toughened glass (ESG}, 1600 mm wide and
2800 mm long, and with a nominal thtckness of 6 mm:
Toughened glass DIN1249-ESG-6-1600-2800
6 Work on glass
6.1 Edges
i i
I i
Panesshall, as a minimum, have no sharp edges (cf. DIN1249
Part 11).
J ..........
6.2 Drilling holes and cutting out
Drilling holes and cutting out is only permitted prior to the
glass being prestressed.
i
6.2.1 Holes
The minimum distance of a hole edge from the glass edges
and from other hole edges shall be twice the glass thickness.
If there' more than four holes in any configuration,
the manufai:turer shall be consulted regarding minimum
distances. If ahole is drilled in the corner-of a pane so that a .
hole edge is 'less than 35 mm from the glass edge. the cor
responding distance from the other edge shall be at least
5 mm greater.
The limit deviations on distances shall be on the lines of
table 2.
1
,I
6.2.2 Cutting out
, I
The many possibilities of cutting out cannot be dealt with
here. The extent and location of cutting out shall be subject to
agreement with the manufacturer.
. 7' sample panes
Given the wide. variety of glass and pane types, the size of
sample,panes shall be subject to agreement with the manu
facturer.
- -- _._-_ -.-..-_ _ __ .
1
I
'I
Table.S;: Num.ber and size of fragments In DIN 52349 test
I
,
glass.
11 Physical requirements
11.1 Resistance to fracture
If toughened glass is tested as'specified in DIN 52349. the
number, size and length of fragments shall be not more than
given in table
11.2 Bending strength
When tested as specified in DIN 52303, toughened glass
shall be found to have a minimum bending strength as given in
table 6. '
j ....
Table 6. Minimum bending strength
or c- r,.I'
".
type
Clear f1oaUpolished plate
Cast, sheet and other types
Surface-coated
(clear f1oaUpolished plate,
with coating on surface
and in tension zone)
Surface-coated
(clear floaUpolished plate,
with coating on surface
and in compression zone}
Minirrfum
Nomlnal,c;
bending
thickness
as in table f.
.strength-).
4 to 15
4 to 15
ln N/mm
2
,
..
120
90
'75
6to 15
I
120
*} Defined here as the minimum bendlnq-stress result
ing in a probability of failure of 5 % for a % con-.
fidence level.
r
..J.
- \.J'
"
Minimum number
'\
Maximum area Nominal
of fragments.
of largest fragment, thickness . type
(over 10 cm X 10.cm
in cm
z
as In table 1
test area)
"
Clear float/polished plate .
15 25 .4 and 5
Clear float/polished plate "',,
30 15. 6 to 15
Cast, Sheet and other types 15 25 4 to 15
SUrface coated.
30 6 to 15 . 15
Maximum length
of longest fragment,
incm.
..
:18
12
18
12
:
'j
"
c
I
i
-;r;r""
..
I
.!:;"
.':'--'I l
, .
..-!i' ;
. 1249 Part 12
Marking
Each pane of toughened glass shall be indelibly marked with at least the following:
DIN 1249-ESG
The marking shall be visible on installed panes uncer normal conditions.
....'
'.
. referred to ,
DIN 1249' Pail 'f-Glass.for use in building construction; sheet glass; dimensions
, DIN, 1249 Part 3 Glaes'for us-e in building construetlon: clear float and polished plate, glass; dimensions
DIN 1249 Part 4 Glass for use in bUilding construction; cast glass; dimensions
. DIN '1249 Part 11 Glass for use in building construction; work on giass edges
,
DIN 1259 Part 2 Glass products; terminology
DIN 52303 Part 1 Methods of testing flat glass for use in building construction; determination of bending strength with speci
mens suppo:ted ..t two points
DIN 52 349 Testing of glass for use in building construction; fracture pattern
International Patent Classification
i,(') 03 B 27/00
,-c. 06 B 3/00
E 04 C 2/54
G"01 821/00
..'
(
,\
"
I