Вы находитесь на странице: 1из 1

Polaris

GENERAL DATA PUMPS AND MOTORS

Q M P V n Dp

US gpm (l/min) lbf in (Nm) HP (kW) in3/rev (cm3/rev) min -1 psi (bar)

Flow Torque Power Displacement Speed Pressure

Efficiencies
Pumps hv= hv (V,Dp, n) hm= hm (V,Dp, n) ht = hv hm Volumetric efficiency Mechanical efficiency Overall efficiency ( 0,97) ( 0,88) ( 0,85) Motors ( 0,96) ( 0,85) ( 0,82)

DESIGN CALCULATIONS FOR PUMP Q= V(cm 3 /rev) h v n 10 -3 [l/min]

DESIGN CALCULATIONS FOR MOTOR V (cm 3 /rev) n 10 -3 hv D p (bar) V (cm 3 /rev) h m 62,83

Q=

[l/min]

M=

D p (bar) V (cm 3 /rev) 62,83 h m D p (bar) V (cm 3 /rev) n 600 1000 h t

[Nm] M=

[Nm]

P=

600 1000

[kW]

Note: Diagrams providing approximate selection data will be found on subsequent pages.

002

DCAT033-003

01/10.03

P=

[kW]

D p (bar) V (cm 3 /rev) n h t

Вам также может понравиться