Вы находитесь на странице: 1из 18

Calculation of Furnace

Losses

Furnace Heat Losses


Conductive heat losses Convection heat losses Cooling losses Sting outs

Conduction Through an Insulated Wall


Calculate the heat loss through a 4 x 8 ft wall First layer 9 Greenlite 3000 2nd layer 4.5 B & W delta 3rd layer 4.5 Greenlite 28 4th layer 1 JM Superex 1600*F Hotside is 2400 degF Coldside is 75degF

Go To Furnace Losses
Click on furnace losses

Miscellaneous Walls
Click on Misc walls Show bricks by clicking on arrow to the right of the name Select a brick from list

Enter data
Click on Depth to Enter a Value Enter Hot and Cold Side Temperatures

Calculate Heat Loss


Click on calc Calculated heat loss through wall is 6304 MBU/hr Notice that hotside temperature for B&W delta exceeds max workable temperature (1900 degF)

More Bricks
This is great but what if my bricks are not shown in the database ?
Then you have to add your bricks to the database. Ill show you how.

Adding Bricks
From Menu Select Edit Bricks Click on Name Type in your new Name

Adding New Bricks


Select type of brick Enter conductivity for at least one temperature Enter max working temperature

Add New Bricks


Click on add

Add new bricks


and there it is !
Thats all there is to it !

Sting Outs

Sting Outs Are Heat Losses Through Openings in the Wall

Sting Outs
Select sting outs from menu Enter opening size Enter hotside and coldside temperatures Click on calc

Water Cooling

Calculates Heat Losses From Cooling Water

Water Cooling
Select cooling from top menu Enter inlet and outlet temperatures Enter cooling water flow rate Click on calc

Help Menus

Furnace Losses
Click here to see calculations

Вам также может понравиться