Вы находитесь на странице: 1из 1

Description: Missing neighbours.

Possible Cause:
Human negligence. Poor NB planning. Street canyon effect that requires more than 2 tier NB planning etc.

Description:
UE did not perform any Measurement Reporting after last successful ASU + ASUC + Measurement Control sent, although the reporting criteria has been reached to perform MR e1a, e1b or e1cPossible

Possible Cause: Since Soft Handover (Soft & Softer) is MEHO (Mobile Evaluated Handover), the decision
to send MR is completely relying on UE when reporting criteria has been reached. Could only suggest that it is UE related problem.

Description:
MR e1x (a/b/c) with No ASU Response from Network

Possible Cause:
Do no always assume that this is Network related. It could be due to radio or UE related, even Missing Neighbour could cause this : 1) Network / BTS related: Network / BTS related: 2) UE related: UE did not perform optimum SHO in the earlier MR+ASU+ASUC+MC, thus subsequent MRs could be non optimum. 3) Radio related: Due to non dominance etc. Could be improved by optimizing L1 coverage of that stretch. Or due to rapid changing radio environment, AS Ec/No degraded rapidly (should verify with both UE traces to confirm), should use AdjsEcNoOffset to advance SHO or mutually make more favorable for SHO. SO

CAD 2 FMT Tools problem (Incomplete setup procedure) CAD 1 RF Related :Dropped due to High BLER CAD 3 Network Issue (forced to terminate the call), Network Related
Network forced to terminate the call by sending RRC_Connection_Release to UE. CAD 4 Network Issue (No ASU + ASUC), RF Related No ASU + ASUC after MR e1a due to RF. CAD 5 Network Issue (No MC), RF Related: No MC after last successful ASC+ASUC due to poor coverage. CAD 6 Weak Coverage, RF related: Drop due to Weak Coverage CAD 10 Network Issue (Cell being removed from the Neighbor List), 17233 (SC204) was removed from the NB list that sending MC to UE. CAF 4 Network problem (Call Setup Failed), This call setup is failed due to incomplete call setting up procedure.There is no Radio Setup Procedure after Call_Proceeding. CAF 5 RF Issue (4x RRC Connection Request), did not reselect to best cells due to missing neighbours.