Вы находитесь на странице: 1из 5

Short column With axial loading Note:- Editing can be allow only in yellow cells Loads P 120 kN Fck

= Fy = 25 415 N/mm2 N/mm2

Size of column B D = = 230 230 0.8 mm mm %

% of Steel Assumed

Effective length Ley Lez 2000 2500 mm mm

Ley / B Lez / D

8.70 10.86957

short column in Ley Direction short column in Lez Direction

Capacity of column

Pu = 0.4 Fck Area of concrete + 0.67 Fy Area of steel

Pu =

524.77 Pu =

+
642.4388 kN

117.67 kN

column is safe Area of Steel For Dia of Bar = = 423.2 12 4 mm2 mm Nos.

No. of bar required =

Short column With Biaxial moments Note:- Editing can be allow only in yellow cells Loads Pu Muz Muy 1600 120 90 kN kN-m kN-m Fck = Fy = 15 415 N/mm2 N/mm2 D

Size of column B D = = 400 600 1.2 mm mm %

% of Steel Assumed

Effective length of column Ley Lez Ley / B Lez / D 4.26 4.26 10.65 7.10 m m column is short in Ley Direction column is short in Lez Direction

Minimum Eccentricity e = (Effective length of column/500 +( B or D) / 30 ) OR 2cm whichever is max Ex Ey 2.19 2.85 cm OR cm OR 2 2 Whichever is maximum Whichever is maximum

Moment due to minimum eccentricity

Mz My

34.97 45.63

kN-m kN-m

Actual mmt is max Actual mmt is max

Pu Muz Muy

1600 120.0 90.0

kN kN-m kN-m 25 and Cover 40 mm

Using Dia of Bar =

d' = d' / D d' / B p/Fck = Pu / (Fck x B x D )

52.5 0.088 0.131 0.08 0.44 For major Dierection. For minor Dierection.

Referring chart from SP-16 Page no between 112-147 Considering d' / D , p/Fck , Pu / (Fck x B x D ) Mux1 / (Fck x B x D^2 ) = 0.09

Mux1 = Similarly

194.4

kN-m

Muy1 / (Fck x B^2 x D) =

0.083 Mux1 & Muy1

Muy1 =

119.52

kN-m

Puz = 0.45 Fck Area of concrete + 0.75 Fy Area of steel Puz = Pu / Puz = Alph = 2496.96 0.64 2 kN

Ratio =

Mux Mux1

( )

Muy Muy1

Ratio =

0.948

Less than 1 hence OK.

ex ey

MZ

My

Ultimatemoment carrying capacity of section