Вы находитесь на странице: 1из 1

Common procedure of DT data analyse

1. Check if the DT KPIs meet the requirement. If not, capture the figure. 2. (Load the log data to Probe to preview the events. Capture the failed events.) 3. Check the Ec/Io distribution from UE and Scanner, check if the points that miss the KPI requirement are related to any poor Ec/Io? If Ec/Io from UE is poor, then check Ec/Io from Scanner at the same place. 4. Check the RSCP from UE and Scanner, and check if it is related to the poor Ec/Io? Also compare the result from UE and scanner to see if they are similar. 5. If the Ec/Io or RSCP distribution from UE and Scanner are quite different, there must be something wrong. Analyse it and try to find the reason. 6. (If new cluster) Check the distribution of each PSC, pay attention to the crossed antennas. 7. Analyze the points that miss the KPIs point by point. 8. Capture any abnormal phenomena, and give the file a good name. 9. Integrate all the captured figures, then well get the solution.

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Confidential

Page 1