NINGBO MINGHAN ELECTRIC CO.,LTD.

Add: No.436 Yunlong Town, Yinzhou District, Ningbo City, China Tel: 86-0574-88448888-8028 Fax: 86-0574-83018666

Website: www.meehaa.net

Fiber Optic frame Test Report


ITEM: MH-GPX.A NAME:FIBER OPTIC FRAME TEST REF.NO.: 12-11-RGS147 TEST STANDARD:TLC & YD/T 778-2006 NO. Testing items Grade( B or C type) result 1 Appearance C Type PASS 2 Function B Type PASS 3 Insertion Ross B Type PASS 4 Return Ross B Type PASS 5 Pressing B Type PASS 6 Insulation B Type PASS 7 Low Temperature test B Type PASS 8 High Temperature test B Type PASS 9 Damp & Hot test B Type PASS 10 Convulse test B Type PASS 11 Salt- atmosphere test B Type PASS 12 Tensile test B Type PASS 13 Compatibility test B Type PASS 14 Withstand Voltage B Type PASS 15 Fire resistance test B Type PASS Result: All test can reach YD/T 778-2006 Communication standard and TLC(VE.9) standard. Time:26th July,2011

Fiber Optic frame Test Report (Appearance)


ITEM: MH-GPX.A NAME:FIBER OPTIC FRAME TEST REF.NO.: 12-11-RGS147 TEST STANDARD:TLC & YD/T 778-2006 Testing asking Testing result Conclusion Frame be open or half-open or closed PASS PASS Frame Height: 2600mm or 2200mm or PASS PASS A 2000mm.Width:300mm or 450mm or P 600mm.All size is the same, changeable P +/-2mm. E The angle of doors is more than 110 degree. PASS PASS A All adjustable parts be open easily. R All parts be firmed and steady, not loose. PASS PASS A All angle be safety, not harmful to person PASS PASS N All inner fiber cables, the Min radius of PASS PASS C curvature is 30mm or 15tims of cable. E The appearance of cabinet is smooth and PASS PASS good. Stop bad adhesion, Impacting, Flattening powder praying on cabinet. And the Tensile of powder coating must reach GB/T 9286-1998 standard.

Fiber Optic frame Test Report (Function)


ITEM: MH-GPX.A TEST REF.NO.: 12-11-RGS147 NAME:FIBER OPTIC FRAME TEST STANDARD:TLC & YD/T 778-2006 Testing asking Testing result Conclusion F Fiber cable a) having some fixing parts PASS PASS U protecting b)Cable be insulation to frame N Fiber cable Having suitable welding PASS PASS C welding function to protect fiber cable T or fiber pigtails. I Fiber It be suitable for SC,FC, ST.. PASS PASS O connecting adapters. N Capacity It can hold large capacity with PASS PASS and storing enough storing room.

Fiber Optic frame Test Report (Adapters)


ITEM: MH-GPX.A NAME:FIBER OPTIC FRAME TEST REF.NO.: 12-11-RGS147 TEST STANDARD:TLC & YD/T 778-2006 I Testing items Standard Testing result result n Normal 1# -10# PC,UPC 0.35,APC 1310nm:0.06-0.3,1 PASS s 0.45 550nm:0.05-0.24 e Durability 9# PC,UPC0.5,APC0.6 1310nm:0.13 PASS r 1550nm:0.11 t Changeable 1#-5# PC,UPC0.5,APC0.6 1310nm:0.12-0.26, PASS i 1550nm:0.09-0.24 o High temperature PC,UPC0.5,APC0.6 1310nm:0.10-0.32, PASS n sample:3#-4# 1550nm:0.09-0.28 l Low temperature PC,UPC0.5,APC0.6 1310nm:0.10-0.34, PASS o sample:1#-2# 1550nm:0.09-0.32 s Damp and hot 7#-8# APC0.6 1310nm:0.16-0.26, PASS s 1550nm:0.12-0.22 PC,UPC0.5,APC0.6 Shaking sample 1# 1310nm:0.16-0.29, PASS 1550nm:0.12-0.24 Salt spray sample5#-6# PC,UPC0.5,APC0.6 1310nm:0.16-0.3 PASS 1550nm:0.14-0.26 Flattening sample PC,UPC0.5,APC0.6 1310nm:0.10-0.18, PASS 9#-10# 1550nm:0.09-0.14

Fiber Optic frame Test Report (Adapters)


ITEM: MH-GPX.A NAME:FIBER OPTIC FRAME TEST REF.NO.: 12-11-RGS147 TEST STANDARD:TLC & YD/T 778-2006 R Testing items Standard Testing result result E Normal 1# -10# PC 45,UPC 50 1310nm:50-54, PASS T APC 60 1550nm:51-55 U Durability 9# PC 43,UPC 48 1310nm:51 PASS R APC 58 1550nm:52 N Changeable 1#-5# PC 43,UPC 48 1310nm:52-53, PASS APC 58 1550nm:53-54 L High temperature PC 43,UPC 48 1310nm:50-51, PASS O sample:3#-4# APC 58 1550nm:51-53 S Low PC 43,UPC 48 temperature 1310nm:50-52, PASS S sample:1#-2# APC 58 1550nm:51-53 PC 43,UPC 48 Damp and hot 7#-8# 1310nm:50-52, PASS APC 58 1550nm:51-54 PC 43,UPC 48 Shaking sample 1# 1310nm:52-52, PASS APC 58 1550nm:53-54

Salt spray sample5#-6# PC 43,UPC 48 APC 58 Flattening sample PC 43,UPC 48 APC 58 9#-10#

1310nm:50-53 1550nm:51-54 1310nm:51-52, 1550nm:51-54

PASS PASS

Fiber Optic frame Test Report ( Impacting )


ITEM: MH-GPX.A NAME:FIBER OPTIC FRAME TEST REF.NO.: 12-11-RGS147 TEST STANDARD:TLC & YD/T 778-2006 Item Testing asking Testing result Conclusion i Flattenting Pressure: 3000V/1 min No cracking PASS m testing p a Insulation resistance 1000ohm PASS PASS c Insulation t resistance i n g