Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 1 About This Manual

Chapter 1 About This Manual


1.1 Purpose of This Manual
This manual describes how to commission the M2000 system, including connecting and commissioning devices related to the M2000 server and client. The commissioning covers the following aspects: O&M network commissioning, NE access, commissioning of remote alarm notification service, commissioning of the alarm box and plate, and commissioning of the dial-up service. For details on installing and commissioning the M2000 server and client, see the following manuals:

iManager M2000 Mobile Element Management System Hardware Installation Manual iManager M2000 Mobile Element Management System Software Installation Manual iManager M2000 Mobile Element Management System HA System Hardware Installation Manual iManager M2000 Mobile Element Management System HA System Software Installation Manual

1.2 Intended Users


This manual is intended for network management engineers. To use this manual, you should know the basics of data communication network and mobile communications network management.

1.3 Organization of This Manual


This manual consists of the following chapters:

Chapter 1 Chapter 2

About This Manual introduces the purpose, intended users, and Overview of Commissioning describes the M2000 system

organization of this manual.

commissioning and the external devices involved.

Chapter 3 Commissioning of O&M Network describes how to commission the O&M network, including how to configure each network device and port. Chapter 4 Access of NEs to M2000 describes how to access NEs to the M2000 system and verify the access. Chapter 5 Commissioning of Remote Alarm Notification Service describes how to commission the remote alarm notification service.
Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 1 About This Manual

Chapter 6 Commissioning of Alarm Box describes how to install and set the alarm box, and how to verify its operation. Chapter 7 Commissioning of Alarm Plate describes how to install and set the alarm plate, and how to verify its operation. Chapter 8 Commissioning of Dial-Up Connection describes how to commission the dial-up connection and verify its operation.

1.4 References
This manual refers to the following documents:

iManager M2000 Mobile Element Management System Hardware Installation Manual iManager M2000 Mobile Element Management System Software Installation Manual iManager M2000 Mobile Element Management System HA System Hardware Installation Manual iManager M2000 Mobile Element Management System HA System Software Installation Manual iManager M2000 Mobile Element Management System Operation Manual

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 2 Overview of Commissioning

Chapter 2 Overview of Commissioning


2.1 About This Chapter
This manual introduces devices connected to the M2000 system and their networks, and describes the procedure for commissioning these external devices.

2.2 Network Connection


The M2000 system consists of an M2000 server and multiple clients. Figure 1.1 shows the connection between the M2000 and the external devices.

Figure 1.1 External devices connected to the M2000 The external devices are connected to the M2000 in two ways:

Through the serial port cable. These devices include the Modem and the alarm box. The devices, the M2000 server and clients compose the M2000 system in a broad sense.

Through the TCP/IP-based O&M network. These devices include NEs and network connection devices managed by network management system (NMS) and M2000, such as the cross multiplex device, LAN switch, router and firewall.

2.3 Commissioning Procedure


The M2000 system commissioning includes the connecting and commissioning of each related device. Table 1.1 shows the procedure in detail.
Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 2 Overview of Commissioning

Table 1.1 M2000 system commissioning procedure No. 1 Step Commission the O&M network. Purpose Construct the O&M network, and ensure that the M2000 communicates with NE devices and the upper NMS through TCP/IP. 2 Cover various NEs into the management of the M2000 system. Install the mediation software for each NE to access the M2000 system, and set up management objects for these NEs to operate on and maintain them through the M2000. 3 Commission Modem and the remote alarm notification function. 4 Commission the alarm box or plate. Ensure that the alarm box or plate gives audio or visual alarm accordingly. Chapter 6 Commissioning of Alarm Box Chapter 7 Commissioning of Alarm Plate 5 Commission the dial-up connection. Ensure that the remote user can use the PSTN network to log in to the M2000 system through dial-up. Chapter 8 Commissioning of Dial-Up Connection Ensure that the alarm information can be sent to users in SMSs and e-mails. Chapter 5 Commissioning of Remote Alarm Notification Service Chapter 4 Access of NEs to M2000 Reference Chapter 3 Commissioning of O&M Network

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Chapter 3 Commissioning of O&M Network


3.1 About This Chapter
This chapter describes the O&M networking mode and the procedure to set each networking device.

3.2 System Networking


3.2.1 Overview of Networking
The M2000 system communicates with NEs through the TCP/IP protocol. The physical layer can use the partial or whole E1/T1, or the DDN/X.25 mode to transmit data. The M2000 supports two networking modes: local area network (LAN) and wide area network (WAN). The networking plan depends on the geographical location of NEs and user requirements. Use the LAN when all the NEs are located in the same network segment. Otherwise, use the WAN.

3.2.2 LAN Networking


I. Networking Diagram
For the LAN networking, the M2000 can connect NEs in both star and bus networking modes. Use the star networking to connect all NEs in the LAN to the M2000 through a LAN Switch or concentrator, as shown in Figure 1.1.

Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Figure 1.1 LAN star networking diagram Figure 1.1 is a general networking diagram. It omits details about connecting some network devices such as the router.

II. Commissioning Procedure


Table 1.1 shows the commissioning procedure for the LAN networking. Table 1.1 Commissioning procedure for the LAN networking No. 1 Operation Use network cables to connect the M2000 server, clients and various NEs to LAN switch A in the public network. 2 Connect devices in the M2000 server system (including the disk array, local console and SC) to LAN switch B through the private network. 3 If there is only one LAN switch, divide VLANs on the switch to distinguish between the public and private networks. see the appropriate manual for details on the configuration.

To set up communication channels from the M2000 to NodeB through RNC, you should set routes to the NodeB. Set these routes in two ways:

Through the router. See 3.5Configuring Quidway AR 28-10 Router for setting the router. Through the M2000 server. Configure the default static route or multiple routes

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

on the M2000 server. For details, see M2000 Administrator Guide or M2000 HA System Administrator Guide.

III. Dial-Up Access


The M2000 also supports the dial-up access mode. To use this connection mode, a dial-up server must be installed in the M2000 system. The M2000 client accesses the M2000 dial-up server through the PSTN network, and the dial-up server assigns an IP for this client. In this way, the user logs in to the M2000 system through the M2000 client interface. For details on the dial-up connection, see Chapter 8 Connection. "Commissioning of Dial-Up

3.2.3 WAN Networking


I. Networking Mode
A WAN is composed of multiple LANs. The LANs are connected with each other in different modes. Table 1.1 lists details about the networking mode. Table 1.1 WAN networking mode Networking mode Through partial E1/T1 Description This is a common networking mode. It uses idle timeslots in the existing E1/T1 transmission line to transmit the NMS data. The advantage of this networking mode is that every operator has its own E1/T1 transmission network. In this way, it is convenient to provide transmission channels, assign network addresses and maintain the communication channels based on existing resources. This saves the operators investment to a great extent. Through whole E1/T1 The whole E1/T1 networking does not require timeslot extract and interchange. The whole E1/T1 with the 2 M bandwidth is available for transmitting the NMS data. This mode suits cases with redundant transmission resources and large quantities of data. Through DDN/X.25 This networking mode uses the conventional Digital Data Network (DDN) or X.25 network to transmit the NMS data. It has the advantages of reliable communications over the private line and stable transmission quality, but has the disadvantage of high cost.

Huawei Technologies Proprietary 3

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

II. Partial E1/T1 Networking Mode and the Commissioning Procedure


To use the partial E1/T1 networking mode, you should configure the timeslot cross device Mercury3600, the router and the LAN switch, as shown in Figure 1.1. This networking mode does not require the firewall. If necessary, set the firewall between the M2000 server and NEs or clients.

Figure 1.1 Partial E1/T1 networking mode Table 1.1 shows the commissioning procedure for the partial E1/T1 networking mode. Table 1.1 Commissioning procedure for the partial E1/T1 networking No. 1 Operation Use network cables to connect the M2000 server, clients and various NEs to the LAN switch in the public network. Follow Table 1.1 to connect and configure devices in the M2000 system in the private network, such as the disk array, local console and SC. 2 Configure the LAN switch. User manual of the LAN switch 3 Configure the router at the NE side. 3.5Configuring Quidway AR 28-10 Router 4 Configure the router at the M2000 server side.
Huawei Technologies Proprietary 4

Reference None

3.6Configuring Quidway 3640 Router

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

No. 5

Operation Configure the timeslot cross device Mercury3600.

Reference 3.4Configuring Timeslot Cross Device Mercury 3600 3.3Setting Firewall Port

Set the firewall if any in the network.

III. Whole E1/T1 Networking Mode and the Commissioning Procedure


To use the whole E1/T1 networking mode, you should configure the router and LAN switch, as shown in Figure 1.1. This networking mode does not require the firewall. If necessary, set the firewall between the M2000 server and NEs or clients.

Figure 1.1 Whole E1/T1 networking mode Table 1.1shows the commissioning procedure for the whole E1/T1 networking mode. Table 1.1 Commissioning procedure for the whole E1/T1 networking No. 1 Operation Use network cables to connect the M2000 server, clients and various NEs to the LAN switch in the public network. Follow Table 1.1 to connect and configure devices in the M2000 system in the private network, such as the disk array, local console and SC. 2 Configure the LAN switch. User manual of the LAN switch
Huawei Technologies Proprietary 5

Reference None

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

No. 3

Operation Configure the router at the NE side.

Reference 3.5Configuring Quidway AR 28-10 Router

Configure the router at the M2000 server side.

3.6Configuring Quidway 3640 Router

Set the firewall if any in the network.

3.3Setting Firewall Port

IV. DDN/X.25 Networking Mode and the Commissioning Procedure


The network devices and commissioning procedure for the DDN/X.25 networking mode are the same as those for the whole E1/T1 networking mode. The only difference lies in that the E1/T1 networking use the E1/T1 cable while the DDN/X.25 networking uses the DDN or X.25 private cable.

3.3 Setting Firewall Port


3.3.1 Introduction to Firewall
The firewall function is to filter the traffic and to protect the system from network attack. A firewall device is required between two different security areas.

I. Filtering Traffic
The firewall filters traffic through a set of security check rules. It allows only network data that meets set conditions to pass Thus it ensures the network security. In the O&M network, the device type, quantity and the type of traffic between device nodes are limited and specific. This makes it possible to set the firewall to filter invalid traffic. In the O&M network, the valid traffics include:

Data stream between the M2000 server and various NEs Data stream between the M2000 server and various clients Data stream between the M2000 server and the NMS Data stream between LMT and devices Data stream for updating virus codes

II. Protecting Against Network Attack


When configuring the firewall, ensure to enable the following functions:

Protecting against the IP fraudulence attack Protecting against the Land attack Protecting against the Smurf attack
Huawei Technologies Proprietary 6

Commissioning Guide iManager M2000 Mobile Element Management System


Chapter 3 Commissioning of O&M Network

Protecting against the Fraggle attack Protecting against the WinNuke attack Protecting against the SYN Flood attack Protecting against the ICMP Flood attack Protecting against the UDP Flood attack Controlling ICMP redirection packets Controlling ICMP destination unreachable packets Protecting against the address scan attack Protecting against the port scan attack Controlling IP packets with the source site option Controlling IP packets with the route record option Enabling the Tracert packet control Protecting against the Ping of Death attack Protecting against the Teardrop attack Checking validity of TCP packets Checking IP fragmentation packets Controlling oversize ICMP packets

3.3.2 Configuring Firewall


The M2000 server communicates with NEs, clients and the NMS through the TCP/UDP protocol. The firewall security policies work with the IP address and TCP/UDP port number to filter the data traffic. The TCP/UDP port number ranges from 0 to 65535. The range is divided into three segments:

Port numbers 0-1023 are for identifying some standard services, such as FTP, Telnet, SMTP and TFTP. Port numbers 1024-49151 are for Internet Assigned Number Authority (IANA) to assign to registered applications. Port numbers 49152-65535 are private and can be assigned dynamically to any applications.

According to various networking security requirements, you can set the firewall:

Between the M2000 server and various NEs. For details on setting the firewall port, see 3.3.3Setting Ports Between M2000 Server and NEs. Between the M2000 server and clients. For details on setting the firewall port, see 3.3.4Setting Ports Between M2000 Server and Clients. Between the M2000 server and the NMS. For details on setting the firewall port, see 3.3.5Setting Ports Between M2000 Server and NMS.

Huawei Technologies Proprietary 7

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

3.3.3 Setting Ports Between M2000 Server and NEs


To install the firewall between the M2000 server and NEs, Open the ports at the NE side and the M2000 server side according to the following requirements:

Open some ports at the NE side to any port at the M2000 server side, so that any port at the server side can access ports at the NE side behind the firewall. Open some ports at the M2000 server side to any port at the NE side, so that any port at the NE side can access ports at the server side behind the firewall.

Table 1.1 lists the ports to open at the NE side. Table 1.1 Port numbers used by NE services NE type RNC 123 UDP port TCP port 20, 21, 23, 6000, 6001, 6002, 6007, 6021, 6022, 6088, 6099, 6100 and 16002 CG 123 20, 21, 23, 6000, 6001, 6002, 6007, 6010, 6099, 6100 and 16002 HLR 123 20, 21, 23, 6000, 6001, 6002, 6005, 6006, 6007, 6008, 6009, 6099 and 16002 MGW 123 20, 21, 23, 6000, 6001, 6002, 6006, 6007, 6010, 6099, 6100 and 16002 GGSN 123 20, 21, 23, 6000, 6001, 6006, 6099, 6100 and 16002 SGSN 123, 161 and 162 20, 21, 23, 5000, 6000, 6001, 6002, 6006, 6099, 6100, 6101 and 16002 NodeB IWF 123 123 20, 21, 23, 6000, 6001, 6006 and 6007 20, 21, 23, 7000, 7001, 7005, 7007, 7011, 7021, 7099 and 16002 MSC Server IP device BSC GT800 BSC MSC 8888
Huawei Technologies Proprietary 8

123

20, 21, 23, 6000, 6001, 6002, 6004, 6005, 6006, 6007, 6008, 6009, 6099 and 16002

161 and 162 -

8888 8888

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

NE type HLR36 PCU/PC U33 CHLR iMSC tMSC CBSC CMSC AAA HA CHLR98 20 PDSN RAC MSCe 123 123 161

UDP port 8888 8888

TCP port

8888 6000, 6001 and 6002 6000, 6001 and 6002 21, 6000, 6001, 6002 and 6009 6000, 6001 and 6002 1888, 6000 21, 6000, 6001, 6002, 16002 20, 21, 23, 6000, 6001, 6002, 6005, 6006, 6007, 6008, 6009, 6099, 16002 21, 6000, 6001, 6002 and 16002 21, 6000, 6001, 6002 and 6009 20, 21, 23, 6000, 6001, 6002, 6004, 6005, 6006, 6007, 6008, 6009, 6099 and 16002

POC GLMS

21, 6000 and 6001 21, 6000 and 6001

Table 1.2 describes the use of each port. Table 1.2 Use of ports used by NE services Port type TCP Port No. 20 and 21 Use For loading NE software, and uploading and downloading software and logs 23 6000 For maintaining the Telnet service For the M2000 to deliver maintenance commands and for the NE to respond 6001 For the NE to report alarm data
Huawei Technologies Proprietary 9

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Port type

Port No. 6002 6099 16002

Use For the NE to report performance data For the NE to report configuration data For the NE to report performance data covering all counters

8888 Other ports

For communication with BAM For the alarm box, commissioning and binary packets, depending on the NE type

UDP

123 161 162

For synchronizing the NTP time SNMP AGENT SNMP TRAP

Table 1.3 lists the ports to open at the M2000 server side and their use. Table 1.3 Number and use of ports used by services on the M2000 server for connecting NEs Port type TCP Port No. 20 21 UDP 123 For FTP control For FTP data For synchronizing the NTP time Use

3.3.4 Setting Ports Between M2000 Server and Clients


To install the firewall between the M2000 server and clients, open ports according to the following requirements:

Open some ports at the M2000 server side to any port at the M2000 client side, so that any port at the client side can access ports at the server side behind the firewall.

Open some ports at the M2000 client side to any port at the M2000 server side, so that any port at the server side can access ports at the client side behind the firewall.

Table 1.1 lists the ports to open at the M2000 server side and their use.

Huawei Technologies Proprietary 10

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Table 1.1 Number and use of ports used by services on the M2000 server for connecting clients Port type TCP Port No. 20 and 21 23 6050 7100 7777 8088 and 9088 9025 9990 9999 10119 19999 51001-51016 and 51213-51219 53000 UDP 123 For the M2000 monitoring process For synchronizing the NTP time Use For FTP control and data For maintaining the Telnet service For Xserver For the Sun font service For the M2000 log service For the report server For the M2000 audit service For the Kernel monitoring For the TAO CORBA name service For the diagnosis tool For the TAO notification service For application processes of each M2000 service

Table 1.2 lists the ports to open at the M2000 client side and their use. Table 1.2 Number and use of ports used by M2000 clients for connecting the M2000 server Port type TCP Port No. 6000 53100 UDP 123 Use For the server to connect when the client runs Winaxe For delivering CORBA events For synchronizing the NTP time

Huawei Technologies Proprietary 11

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

3.3.5 Setting Ports Between M2000 Server and NMS


To install the firewall between the M2000 server and the NMS, open ports according to the following requirements: Open some ports at the M2000 server side to any port at the NMS side, so that any port at the NMS side can access ports at the server side behind the firewall. Table 1.1 lists the ports to open at the M2000 server side and their use. Table 1.1 Number and use of ports used by services on the M2000 server for connecting the NMS Port type TCP Port No. 51210 Use For connecting the CORBA interface of the NMS for the M2000 northbound service 8765 4100 UDP 8001 and 10163 For forwarding M2000 alarms to the NMS For the Sybase database service For the M2000 SNMP service

3.4 Configuring Timeslot Cross Device Mercury 3600


3.4.1 Introduction to Mercury 3600
I. Overview
Mercury 3600 is a digital cross connection device (DACS) produced by TAINET. It supports multiple interface standards and has powerful timeslot cross capability. Mercury 3600 has five general slots for holding 4-channel E1 and 2-channel V.35 interface modules (or the DATA module). It provides up to 16 E1 channels, and supports cross connection of any timeslot between any two ports. Any port supports the performance monitoring and system maintenance with the local or remote loop.

II. Front View


TAINET MEACURY 3600

Figure 1.1 Front view of the Mercury 3600

Huawei Technologies Proprietary 12

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

As shown in Figure 1.1, the Mercury 3600 has 20 LEDs, one fluorescent 16x2 liquid crystal display (LCD), four buttons and one terminal interface on its front panel. The LEDs on the front panel reflects the major or minor alarm and the system status, including the number of modules, version, and the current date and time.

III. Rear View

4-E1

4-E1

4-E1

4-E1

4-E1

Figure 1.1 Rear view of the Mercury 3600 The back panel of the Mercury 3600 has five slots for holding interface modules, such as the 4-channel E1 and 2-channel V.35 interface modules. As shown in Figure 1.1, all the five slots of the Mercury 3600 hold 4-channel E1 interface modules. The Mercury 3600 uses the AC power supply. It can also use the DC power supply. Figure 1.2 shows an interface module.

Figure 1.2 Interface module plug-in Different interface modules provide different types of interfaces. Select the type of modules according to the actual need. Insert the module in the back panel of the Mercury 3600 and fix it. Ensure to change the module, when the power is switched off. Insert the new module into the slot, screw the module, and then switch on the equipment.

Huawei Technologies Proprietary 13

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

IV. Performance
Table 1.1 Basic performance of the Mercury 3600 Item Features Description Provide five slots and support up to 16 E1s. Support five access modes: E1, T1, V.35, IDSL and IP. Can be used as CSU/DSU, E1-T1 converter, multi-channel CSU or DACS. Can provide 512x512 timeslots for interchange. Can use the terminal settings. Can use AC or DC power supply. Network interface (E1) Line rate: 2.048 Mbit/s 50 ppm Line code: AMI/HDB3 Input signal: up to ITU-T G.703 Jitter tolerance: up to ITU-T G.823 User equipment interface (V.35/RS530/X.21/RS-449) Clock control Support the E1/T1 port as the master clock source. Support the E1/T1 port as the slave clock source. Provide an internal clock. Provide the clock holdover mode. Support automatic clock mode selection. Power supply AC or DC power supply DC: from -36 V to -72 V AC: 90 VAC to 240 VAC and 50/60 Hz Physical characteristics Dimension: 43 cm W x 33 cm H x 4.4 cm D [16.93 in. W x 12.99 in. H x 1.73 in. D] Temperature: 0C [32F] to 50C [122F] Humidity: 0-95% (congelation) Installation: on the 19 rack (for the desktop) Weight: 3 Kg [6.615 lb] Data rate: Nx64 kbit/s (N = 1-31)

Huawei Technologies Proprietary 14

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

V. Interface Cable Numbering


The five interface slots on the back panel of the Mercury 3600 are numbered from 1 to 5 from right to left. Each interface module plug-in card corresponds to several interfaces, A, B, C and D respectively. Table 1.1 lists the interface module and cable marks for the BNC interface of the 4channel E1. Table 1.1 Marks of interface cables for the 4-channel E1 interface module on the Mercury 3600 Interface A B C D Red Green Blue Black TX Orange Yellow Purple Grey RX

Note: Table 1.1 does not apply to the case when the interface cables connecting the 4channel E1 interface modules are marked by TX and RX.

For example:

If you insert a 4-channel E1 interface module in slot 1, 4 channels of E1 links can be accessed, with the interfaces numbered as 1A, 1B, 1C and 1D. If you insert a 2-channel V.35 interface module in slot 2, 2 channels of V.35 links can be accessed, with the interfaces numbered as 2A and 2B.

Caution: Slot 5 shares the same interface resources as slot 4. Set the interfaces to 4A or 4B. Slot 5 is not used if idle interfaces exist.

VI. Introduction to RJ48


If the impedance of the E1 transmission equipment for the network connection is 120

Huawei Technologies Proprietary 15

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

ohm, use the interface module and cables matching this impedance on the Mercury 3600, and use the balanced cable (4-core twisted pair) as the transmission cable. In this case, the interface uses the RJ48 interface standard. Table 1.1 defines the interface. Table 1.1 RJ48 interface cable sequence Pin 1 2 3 4 5 6 7 8 Receiver Receiver + Transmit Transmit + Description

This interface can also use the RJ45 connecter. The cable sequence is the same as that described in Table 1.1.

3.4.2 Mercury 3600 LEDs and Common Commissioning Commands


I. LEDs on Front Panel
After you switch on the Mercury 3600, the indicators on the front panel that correspond to the port with a plug-in turn on. In addition, there are also three general indicators on the front panel. Table 1.1 describes the meaning of each indicator. Table 1.1 Description of indicators on the front panel of the Mercury 3600 Indicator Indicators corresponding to the port with a plug-in Red Yellow Green Three general indicators Red Meaning Indicates that the link is faulty. Indicates that one end is faulty. Indicates that the link is normal. Indicates that faulty links exist in the

Huawei Technologies Proprietary 16

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Indicator

Meaning network system. Yellow Indicates that one end of the network system is faulty. Green Indicates that all physical links in the network system are normal.

II. Common Commands for Commissioning Mercury 3600


Table 1.1 lists the common commands for commissioning Mercury3600. Table 1.1 Common commands for commissioning the Mercury 3600 Command ALM BOOT CLK PortID Use To view alarm information. To reset the equipment. To define the port to extract the clock. You can only extract the clock from ports A and C. When PortID is INT, it means to extract the internal clock. STAT PortID XC Port1ID Port2ID XV Port1 TSa Port2 TSb Count V35 PortID Count1 Count2 LINK PortID RCRC:X TCRC:X To view the port state. To interchange all timeslots at ports 1 and 2. To interchange Count timeslots, with TSa at port 1 and TSb at port 2 as the start timeslots. To define that Count2 timeslots from timeslot Count1 at this port are for the V.35 interface module. To define that links at port PortID go through CRC at data receiving and transmitting. X = 0 means no CRC, and X = 1 means to adopt the CRC. LOGL LOGB LOGE N Filename LOGI N Reboot To view Profile. To define the start of a Profile. To define the end of a Profile. To define that the system invokes automatically No. N Profile on reboot.

Huawei Technologies Proprietary 17

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Command LOGR N LOGV N CLS DATE TIME

Use To invoke No. N Profile manually. To view No. N Profile. To clear the screen. To set the date and time.

3.4.3 Before Configuration


This section uses an instance to introduce the scheme planning and commissioning procedure.

I. Planning Scheme
Figure 1.1 shows the timeslot cross scheme for the Mercury 3600.

Figure 1.1 Mercury 3600 timeslot cross scheme

Use idle timeslots in the E1 line from the switch to transmit NMS information. Connect the E1 line with idle timeslots to port 1A on the E1 interface module on the Mercury 3600.

Connect the cable from the router to port 2A on the V.35 interface module. Interchange all timeslots at ports 1A and 2A to port 1B. In this way, port 1B integrates all information on ports 1A and 2A. Connect port 1B to the remote E1 network.

II. Installing and Connecting Hardware


Install the Mercury 3600 according to Mercury 3600 Installation Manual. Figure 1.1 shows how to connect Mercury3600 with peripheral devices.
Huawei Technologies Proprietary 18

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Figure 1.1 Mercury 3600 engineering connecting diagram The connection is described as follows:

Insert a 4-channel E1 interface module in slot 1 on the back panel of the Mercury 3600. The switch extends a pair of E1 cables with idle timeslots to connect a pair of terminals on the DDF rack in the transmission equipment room. This pair of E1 cables then jumps to port 1A on the E1 interface module. In this way, the Mercury 3600 is connected to the switch through port 1A and the corresponding E1 port on the switch. Connect port 1B on this E1 interface module to the transmission equipment, and then connect it to the remote end in the WAN (the E1 network).

Interchange all timeslots at port 1A to port 1B. Insert a 2-channel V.35 interface module in slot 2 on the back panel of Mercury 3600. Connect port 2A on this module to port S (the WAN network port) on the router. The Mercury 3600 defines some timeslots at port 2A as channels for transmitting NMS messages, and interchanges these timeslots to port 1B to extend them to the remote end. In this way, port 1B integrates information on both ports 1A and 2A.

At the other end of the network, the Mercury 3600 extracts the timeslots for transmitting NMS messages in the same way, and communicates with the corresponding LAN through the router.

3.4.4 Procedure
According to 3.4.3IPlanning Scheme, configure the Mercury 3600 as follows:

Huawei Technologies Proprietary 19

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

I. Configuring HyperTerminal
1) A serial port cable with 9-pin connectors at both ends is delivered with the Mercury 3600. Use the cable to connect the terminal port on the front panel of the Mercury 3600 and the serial port on the PC. 2) Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the communications parameters as: 19200 bit/s, eight data bits, no check bit, one stop bit, flow control as Xon/Xoff. 3) Switch on the Mercury 3600, and HyperTerminal displays information about Mercury 3600. Now the Mercury 3600 enters the inquiry state.

Note: You can use any type of emulation terminal programs, such as the HyperTerminal of Windows 2000.

II. Logging in to Mercury 3600


To modify the parameters of the Mercury 3600, execute the following command to log in to the Mercury 3600: Mercury>Login _parameter 1 _parameter 2 Parameter 1: username, with the default setting as TAINET. Parameter 2: password, with the default setting as 3600. Execute HELP commands to query the method and syntax for using each specific command.

III. Configuring Mercury 3600 at One Side


1) Define the start of a new Profile.

MERCURY> LOGB 2) Extract the clock from port 1A. //Ensure to extract the clock on the two Mercury 3600s in the

MERCURY> CLK 1A same way. 3)

Define that the links at port 1A do not go through CRC.

MERCURY> LINK 1A RCRC:0 TCRC:0 4) Define that the links at port 1B do not go through CRC.

MERCURY> LINK 1B RCRC:0 TCRC:0 5) Interchange all timeslots at port 1A to port 1B.

Huawei Technologies Proprietary 20

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

MERCURY> XC 1A 1B 6) Define timeslots.

MERCURY> DATA 2A 4 TYPE:4 //For the 2P-DATA module, define that port 2A is a V.35 interface and the bandwidth is 4 timeslots. Or MERCURY> V35 2A 1 2 //For the 2P-V35, define that the two timeslots from the first timeslot at port 2A form the bandwidth, and that port 2A is a V.35 interface and is connected to the WAN network port on the router. 7) Interchange timeslots.

MERCURY> XT 2A 0 1B 1 2 //For the 2P-DATA module, interchange timeslot 0 on port 2A and timeslot 1 on port 1B. Altogether interchange two timeslots. Or MERCURY> XT 2A 1 1B 1 2 //For the 2P-V35 module, interchange timeslot 1 on port 2A and timeslot 1 on port 1B. Altogether two timeslots are interchanged and transmitted to the remote end through port 1B as channels for NMS messages. 8) Save all the above commands into the first Profile. //HEXI1 is the file name. It is definable.

MERCURY> LOGE 1 HEXI1 MERCURY> LOGI 1 boot. 9)

//The system invokes the first Profile automatically on

Exit HyperTerminal, and reset the Mercury 3600.

The configuration of the Mercury 3600 at one side of the network is complete.

IV. Configuring Mercury 3600 at the Other Side


Configure the Mercury 3600 at the other side of the network in the same way. Note to use the actual port number and timeslots to interchange. The procedure is as follows: 1) Define the start of Profile.

MERCURY>LOGB 2) Extract the clock from port 1A. //Extract the clock from the peer-end Mercury 3600 as the

MERCURY>CLK 1A 3)

master clock, so that the two Mercury 3600s use the same clock. Define that the links at port 1B do not go through CRC.

MERCURY> LINK 1B RCRC:0 TCRC:0 4) Define that the links at port 1A do not go through CRC.

MERCURY> LINK 1A RCRC:0 TCRC:0 5) Exchange all timeslots on port 1B to port 1A.

MERCURY> XC 1B 1A
Huawei Technologies Proprietary 21

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

6)

Define that one timeslot from timeslot 1 on port 2A uses the V.35 interface standard and is connected to the WAN port on the router.

MERCURY> V35 2A 1 2 7) Interchange two timeslots from timeslot 1 at ports 2A and 1A as channels for NMS messages. MERCURY> XT 2A 1 1A 1 2 8) Save all the above commands into the first Profile. //The file name is WGZX. //The system invokes the first Profile automatically on

MERCURY> LOGE 1 WGZX MERCURY> LOGI 1 boot. 9)

Exit HyperTerminal, and reset the Mercury 3600.

Now, the two Mercury 3600s at both sides of the network are configured ready. When the physical links work properly, the indicator on the front panel of the Mercury 3600 for the connected port turns green.

3.5 Configuring Quidway AR 28-10 Router


3.5.1 Introduction to Quidway AR 28-10
I. Overview
Quidway AR 28-10 works as the router for NE devices in the M2000 remote networking.

Note: The content described in this section applies only to the common networking. For more information, see related technical documents about Quidway AR 28-10.

II. Back Panel


Figure 1.1 shows the back panel of Quidway AR 28-10.

Huawei Technologies Proprietary 22

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

1) Power switch 3) Grounding screw 5) Console port (CON) 7) Fixed Ethernet interface (LAN0) 9) SIC slot 1

2) Power socket 4) Fixed interface (WAN) 6) Auxiliary port (AUX) 8) MIM slot 0 10) SIC slot 2

Figure 1.1 Back panel of Quidway AR 28-10

III. Components and Performance


Table 1.1 lists components and main indices of the Quidway AR 28-10 router. Table 1.1 Components and main indices of the Quidway AR 28-10 router. Item Slot Description 2 SIC slots (Up to 2 SICs can be configured as needed.) 1 MIM slot (Up to 1 MIM can be configured as needed.) Fixed interface 1 10/100Mbps Ethernet interface 1 WAN interface 1 AUX port 1 console port CPU Boot ROM SDRAM Flash memory Dimensions (W x H x D) Weight 6kg MPC8241 512 KB 64 MB (can be extended to 128MB) 8MB 442mm x 44.4mm x 300mm (including the rubber feet)

Huawei Technologies Proprietary 23

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Item Input voltage

Description Rated voltage range: 100-240V a.c.; 50/60Hz Maximum voltage range: 90-264V a.c.; 50/60Hz Rated voltage range: -48- -60V d.c. Maximum voltage range: -36- -72V d.c. 3.3V d.c., 5V d.c., 12V d.c.

Maximum Power Operating temperature Operating relative humidity

60W 0 to 40oC

10%-90% (non-condensing)

Note: Router program operates in SDRAM (Synchronous Dynamic Random Access Memory). Flash memory is used to save router program files, configuration files and so on. Boot ROM is used to save boot and initialization programs of the router.

IV. Fixed Interfaces


Quidway AR 28-10 Router provides 1 fixed console port, 1 AUX port, Ethernet interface(s), and 1 synchronous/asynchronous interface. Their attributes are introduced below. 1) Console port (CON)

Table 1.1 Attributes of the console port Attribute Connector Interface standard Baud rate 9600bps to 115200 bps 9600bps by default RJ45 RS232 Description

Huawei Technologies Proprietary 24

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Attribute Services supported

Description Connecting with character terminal Connecting with the serial interface of the local PC and operating the terminal emulator on the PC Command line interface

2)

AUX port (AUX)

Table 1.1 Attributes of the AUX port Attribute Connector Interface standard Baud rate Services supported 300 to 115.2kbps Modem dial-up Backup Operating as the console port when the CON fails Protocols supported PPP SLIP MP RJ45 RS232 Description

3)

Fixed Ethernet interface (LAN)

Table 1.1 Attributes of the Ethernet interface Attribute Connector Interface Frame format supported RJ45 MDI Ethernet_II Ethernet_SNAP IEEE 802.2 IEEE 802.3 Operating 10/100Mbps autosensing
Huawei Technologies Proprietary 25

Description

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Attribute mode Full duplex/half duplex Network protocol supported IP Novell IPX

Description

Note: Ethernet MDI (Media Dependent Interface) is the typical Ethernet interface on ordinary network cards. MDIX is crossover media-dependent interface, which is generally used on Hubs or LAN switches.

4)

Fixed Wide Area Network interface (WAN)

Table 1.1 Attributes of the WAN interface Attribute Description Synchronous Connector Interface standard and operating mode Minimum baud rate (bps) Maximum baud rate (bps) 64k 4.096M 2.048M 115.2k 1200 1200 1200 300 DTE, DCE DTE DCE V.24 (RS232) DB50 V.35 V.24 (RS232) Asynchronous

Huawei Technologies Proprietary 26

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Attribute

Description Synchronous Asynchronous Modem dial-up Asynchronous leased line Terminal access Backup

Services supported

DDN leased line Backup Terminal access

Protocols supported

PPP MP LAPB HDLC SDLC X.25 (ITU-T X series recommendations ) Frame Relay

PPP SLIP MP

3.5.2 QuidwayAR 28-10 Command View


The command line of the Quidway AR 28-10 router adopts the hierarchical protection to avoid intrusion of unauthorized users. Different commands should be executed on the corresponding command views. Table 1.1 lists functional features of the common command views and commands for entering each view. Table 1.1 Common command views of Quidway AR 28-10 Command view User view Display basic information about operation and statistics System view Configure system parameters [Quidway] Key in system-view in user view quit returns to user view <Quidway> Function Prompter Entry command Enter right after connecting to the router quit disconnects from the router Exit command

Huawei Technologies Proprietary 27

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Command view User interface view

Function

Prompter

Entry command

Exit command

Manage the asynchronous and logical interfaces on the router

[Quidwayui0]

Key in userinterface 0 in system view

quit returns to system view

Synchronou s/ asynchrono us serial interface view Asynchrono us serial interface view Ethernet interface view

Configure synchronous/a synchronous serial interface parameters

[QuidwaySerial0/0]

Key in Interface serial 0/0 in system view

quit returns to system view

Configure asynchronous serial interface parameters Configure Ethernet interface parameters

[Quidwayasync 0/0]

Key in Interface async 0/0 in system view

quit returns to system view quit returns to system view quit returns to system view

[QuidwayEthernet0/0]

Key in Interface ethernet 0/0 in system view

AUX interface view

Configure AUX interface parameters

[Quidwayaux0]

Key in interface aux 0 in system view

3.5.3 Before Configuration


I. Overview of Scheme Planning
Before configuring the router, plan the following information according to the actual networking:

IP address and subnet mask of port Ethernet0/0 in the local Ethernet network IP address and subnet mask of port Serial0/0 in the WAN Destination network segment, subnet mask and next hop IP address for the wide-used static route Encapsulated protocols for the WAN Clock at the WAN port
Huawei Technologies Proprietary 28

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

II. Routes
The route table contains two types of routes:

Static routes. You can set the route in the route table manually. Static routes are commonly used in networking to realize access to the remote network. Dynamic routes. Dynamic routes in the route table are addressed by the bound dynamic routing protocols, such as OSPF, RIP, IGRP and BGP. With these protocols, the router can discover the corresponding routes dynamically in the network. The route priority varies according to the corresponding protocol.

III. Encapsulated Protocols for WAN


For smooth communications, communications protocols encapsulated on the WAN port on the local router must conform to those for the WAN port on the peer-end router. The common communications protocols are as follows:

HDLC PPP X.25 SLIP Frame Relay LAPB

IV. Clock at the WAN Port


When using the partial E1/T1 networking mode, the WAN port on the Quidway AR 2810 router works as a synchronous serial port. The synchronous serial port can work as a DTE and DCE. Therefore, you should select the clock accordingly.

If as a DCE, it needs to provide clock for the peer-end DET. In this case, select DCEclk. If as a DTE, it receives clock from the peer-end DCE. For the synchronous equipment, the receiving and transmitting clocks are mutually independent. Therefore, you can select the receiving or transmitting clock of the DCE as the receiving clock of the DTE. It is the same case with the DTE transmitting clock. In this way, four combinations are available. That is, the clock at the DTE side has four choices, as shown in Table 1.1.

Table 1.1 Clock selection for the synchronous serial port at the DTE side Selection DTEclk1 DTEclk2 Meaning TxClk = TxClk, RxClk = RxClk TxClk = TxClk, RxClk = TxClk

Huawei Technologies Proprietary 29

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Selection DTEclk3 DTEclk4

Meaning TxClk = RxClk, RxClk = TxClk TxClk = RxClk, RxClk = RxClk

In this table, TxClk is the transmitting clock and RxClk the receiving clock. The clock in front of = is the DTE-side clock, while that behind = is the DCE-side clock. In the partial E1/T1 networking, the router is a DTE, and the Mercury 3600 is a DCE. Therefore, the Mercury 3600 provides the clock for the router.

V. Instance
This section uses an instance to introduce the scheme planning and commissioning procedure.

Plan the IP address of port Ethernet0/0 in the local Ethernet network as 129.9.0.1 and the subnet mask as 255.255.0.0. Plan the IP address of port Serial0/0 in the WAN as 129.8.0.1 and the subnet mask as 255.255.0.0. Plan the destination network segment of the static route as 129.10.0.0, subnet mask as 255.255.0.0 and next hop IP address as 129.8.0.2. Plan the encapsulated protocol for the WAN as PPP. Plan the clock at the WAN port as DTEclk2.

VI. Installing and Connecting Hardware


Install the router according to Quidway AR 28-10/28-11 Routers Installation Manual. Figure 1.1 shows how to connect Quidway AR 28-10 with peripheral devices.

Figure 1.1 Connecting Quidway AR 28-10

3.5.4 Procedure
According to the planning in 3.5.3VInstance, configure Quidway AR 28-10 as follows:

Huawei Technologies Proprietary 30

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

I. Configuring HyperTerminal
1) 2) Use the configuration cable delivered with Quidway AR 28-10 to connect console port (CON) on it and the serial port on the PC. Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the baud rate to 9600, data bit to 8, no parity check, stop bit to 1, flow control to none. 3) Switch on Quidway AR 28-10, and HyperTerminal displays the self-check information about Quidway AR 28-10. When the self-check is complete, the system prompts you to press Enter. 4) Press Enter, and the system enters the <Quidway> state.

II. Configuring Router


This section describes how to use the command line to configure the router. The detailed procedure for configuring Quidway AR 28-10 is as follows: 1) Log in the router.

Switch on the router, and the system carries out the self-check. When the self-check is complete, the system enters the user view, namely, the <Quidway> state. 2) Enters the system view

<Quidway> system-view 3) Execute the following command to check the router configuration data:

[Quidway] display current-configuration The system displays the router configuration. 4) Set the system name as the prompter.

[Quidway] sysname 5) Set the IP address and subnet mask for the Ethernet port.

If the set IP address and mask do not meet the actual requirements, execute the corresponding commands to modify them. For example, to modify the IP of Ethernet0/0, execute the following commands: [Quidway] interface Ethernet0/0. [Quidway-Ethernet0/0] undo ip address xxx.xxx.xxx.xxx 255.xxx.xxx.xxx //Delete the IP address previously configured for this port. [Quidway-Ethernet0/0] ip address 129.9.0.1 and mask for this port. [Quidway-Ethernet0/0] quit 6) Set the static route. //Go back to the prompter [Quidway]. 255.255.0.0 //Reset the IP address

ethernet 0/0

//Enter the environment for setting port

Huawei Technologies Proprietary 31

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

If the set static route does not meet the actual requirements, execute the following corresponding commands to modify it: [Quidway] undo ip route-static ip-address (destination IP) mask (subnet mask) ip-

address (next hop IP)


route. 7)

//Delete the previously set static route. 255.255.0.0 129.8.0.2 //Reset the static

[Quidway] ip route-static 129.10.0.0

Set the IP address and subnet mask for the WAN port. //WAN port. Define serial 0/0 according to the //Delete

[Quidway] interface serial 0/0 actual connection.

[Quidway-Serial0/0] undo ip address xxx.xxx.xxx.xxx 255.xxx.xxx.xxx the IP address previously configured for this port.

[Quidway-Serial0/0] ip address 129.8.0.1 255.255.0.0 //Reset the IP address and mask for this port. [Quidway-Serial0/0] quit 8) //Go back to the prompter [Quidway].

Encapsulate protocols for the WAN port.

The WAN port on the Quidway AR 28-10 router is encapsulated with the PPP protocol by default. To modify the encapsulated communications protocol, execute the following commands: [Quidway] interface serial 0/0 Serial0/0. [Quidway-Serial0/0] link-protocol ppp [Quidway-Serial0/0] quit 9) //Encapsulate PPP. //Enter the configuration mode for the WAN port

//Go back to the prompter [Quidway].

Set the clock for the WAN port.

The Quidway AR 28-10 router works by default as a DTE in the network. It uses the clock in the DTEclk1 mode. To modify the clock mode, execute the following command: [Quidway] clock DTEclk2 //Set the clock mode to DTEclk2.

10) Save the configured data into Flash Memory. [Quidway] save 11) Reboot the router. [Quidway] reboot
This command will reboot the system. The current configuration has not been saved and will be lost if you continue. Continue? [Y/N]

The interface definition and static route configuration are complete. When the router is restarted, enter the user view, and check and modify the configured data.

Huawei Technologies Proprietary 32

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

III. Checking Configuration and Debugging Systemand debugging


When the router configuration at both sides of the network is complete, carry out the system debugging as follows: 1) Display the status of Serial0/0.

When the router configuration is complete at both sides of the network, execute the following command on any router to display the Serial0/0 status: [Quidway] display interface serial 0/0
Serial0/0 is up, line protocol is up physical layer is synchronous interface is DTE, clock is DTECLK1, cable type is V35 Encapsulation is PPP LCP opened, IPCP opened, IPXCP initial 5 minutes input rate 0.00 bytes/sec, 0.00 packets/sec 5 minutes output rate 1.19 bytes/sec, 0.06 packets/sec Input queue is 0/75/0 (current/max/drops)

Queueing strategy: FIFO Output Queue :(size/max/drops)0/75/0 6 packets input, 88 bytes, 0 no buffers

27 packets output, 466 bytes, 0 no buffers 0 input errors, 0 CRC, 0 frame errors 0 overrunners, 0 aborted sequences, 0 input no buffers DCD=UP DTR=UP DSR=UP RTS=UP CTS=UP

If the above information contains the following, it shows that the whole link layer is configured:
Serial0/0 is up, line protocol is up.. LCP opened, IPCP opened DTR=UP DSR=UP RTS=UP CTS=UP DCD=UP

2)

Check the remote network.

Execute ping to check whether the remote network is connected. [Quidway] ping xxx.xxx.xxx.xxx (IP of E0 on the peer-end router)

If the system displays the following information, it shows that the WAN port is not activated:

Serial0/0 is down

In this case, execute the following commands to activate the WAN port: [Quidway] interface serial 0/0 [Quidway-Serial0/0] undo shutdown If still failed, check the cable connection to ensure that all the cables are connected correctly and tightly.

Huawei Technologies Proprietary 33

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

If the system displays:

Serial0/0 is up, line protocol is down......

If you fail to ping the local Serial0/0 and the WAN port and E0 corresponding to the peer-end router, it shows that the connection is not working. In this case, ensure that all the cables are connected correctly and tightly. You can use the self-loop to check if the communications problem is caused by faulty links. Check further the router configuration, including the IP address, mask, static route, protocol encapsulated on the WAN port, the corresponding timeslot, and the extracted clock. Locate the problem, and ensure that you can ping the peer-end LAN successfully.

3.6 Configuring Quidway 3640 Router


3.6.1 Introduction to Quidway 3640
I. Overview
Quidway 3640 is a modularized router of Huawei R2600/3600 series. It works as the network-side router in the M2000 remote network. Note: The content described in this section applies only to the common networking. For more information, see the related technical documents about Quidway 3640.

II. Rear View


Figure 1.1shows the rear view of Quidway 3640.

Figure 1.1 Rear view of Quidway 3640

III. Interfaces
Quidway 3640 provides up to four slots for network interfaces. You can configure up to four interface modules according to the actual need. This section describes the Ethernet module and WAN module used in the M2000 system network. There are two types of Ethernet modules:

1-port 10Base-T/100Base-TX Fast Ethernet interface module (1FE)

Huawei Technologies Proprietary 34

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

2-port 10Base-T/100Base-TX Fast Ethernet interface module (2FE)

The 1FE module provides one 10/100 Mbps Ethernet RJ-45 interface, while the 2FE module provides two. Ethernet ports on Quidway 3640 are numbered from Ethernet 0. For example, if you insert the 1FE module in slot 1 and the 2FE module in slot 2, the Ethernet port for slot 1 is numbered Ethernet 0, and those for slot 2 are numbered Ethernet 1 and Ethernet 2. There are four types of WAN modules:

1-port channelized cE1/PRI module (1E1) 2-port channelized cE1/PRI module (2E1) 4-port channelized cE1/PRI module (4E1) 2SA/4SA fast synchronous/asynchronous serial port module

Each cE1 interface is a Controller E1. The Controller E1 ports are numbered as follows:

The first Controller E1 port is numbered Controller E1 0. From slot 0, the Controller E1 ports are numbered increasingly by degrees. The first Controller E1 port on the module in the following slot is numbered as the number of the last Controller E1 port on the module in the current slot plus one.

On the same interface module, the Controller E1 ports are numbered the same as the numbers marked on the module panel.

For example, if you insert a 4E1 module in slot 1 and a 2E1 module in slot 3 on Quidway 3640, the four cE1/PRI ports on the module in slot 1 are numbered from Controller E1 0 to Controller E1 3, and the two on the module in slot 3 are numbered Controller E1 4 and Controller E1 5.

3.6.2 Quidway 3640 Command View


The command line of the Quidway routers adopts the hierarchical protection to avoid intrusion of unauthorized users. Different commands need to be executed on the corresponding command views. Table 1.1 lists functional features of the common command views and the commands for entering each view. Table 1.1 Command views of Quidway 3640 Name Function Prompter Entry command System view For setting system parameters [Router] Enter this view by logging on the router. Exit command Exit this view by logging off

Huawei Technologies Proprietary 35

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Name

Function

Prompter

Entry command

Exit command the router.

View for the synchronou s serial port

For setting parameters for the synchronous serial port

[Router-Serial0]

Type interface serial 0 on any view to enter this view.

Type quit to go back to the system view.

View for the asynchrono us serial port

For setting parameters for the asynchronou s serial port

[Router-Async0]

Type interface async 0 on any view to enter this view.

Type quit to go back to the system view.

View for port AUX

For setting parameters for port AUX

[Router-Aux0]

Type interface aux 0 on any view to enter this view.

Type quit to go back to the system view. Type quit to go back to the system view. Type quit to go back to the system view. Type quit to go back to the system view.

View for port AM

For setting parameters for port AM

[Router-AM0]

Type interface am 0 on any view to enter this view.

View for port Ethernet

For setting parameters for port Ethernet

[Router-Ethernet0]

Type interface ethernet 0 on any view to enter this view.

View for port CE1

For setting the timeslot binding mode and physical layer parameters for port CE1

[Router-E1-0]

Type controller e1 0 on any view to enter this view.

View for port CT1

For setting the timeslot binding mode and

[Router-T1-0]

Type controller t1 0 on any view to enter this

Type quit to go back to the system view.

Huawei Technologies Proprietary 36

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Name

Function

Prompter

Entry command

Exit command

physical layer parameters for port CT1

view.

3.6.3 Before Configuration


I. Overview of Scheme Planning
Before configuring the router, plan the following information according to the actual networking:

IP address and subnet mask of port E0 in the local Ethernet network IP address and subnet mask of port S0 in the WAN Destination network segment, subnet mask and next hop IP address for the wide-used static route Type of the WAN port, and the communications protocol to bind to interfaces, such as X.25, Frame Relay and HDLC Network protocol to use, such as AppleTalk, IP and IPX (usually IP selected)

II. WAN Port Working Mode


The WAN cE1/PRI port works in two modes: E1 and cE1/PRI.

When working in the E1 mode, it is an interface with a bandwidth as 2 Mbit/s and with no timeslot division. It has the same logical characteristics as the synchronous serial port. It supports link layer protocols such as PPP, Frame Relay, LAPB and X.25, and supports network protocols such as IP and IPX.

When working in the cE1/PRI mode, it is divided into 32 timeslots physically. These timeslots are numbered from 0 to 31. When working as a cE1 interface, it divides randomly all timeslots except timeslot 0 into several groups. The timeslots in each group are bound and work as a channel-group interface. This bound interface supports link layer protocols such as PPP, Frame Relay, LAPB and X.25, and supports network protocols such as IP and IPX.

Huawei Technologies Proprietary 37

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Note: In the partial E1/T1 networking, Quidway 3640 works as the router in the Network Management Center (NMC). It communicates directly with various NE-side routers through port E1. The communication process is as this: the Mercury 3600, a timeslot cross equipment, aggregates NMS information of various managed NEs to one E1 port, and then transmits the aggregated information to port E1 on the router. Therefore, it is important to configure port E1 on Quidway 3640.

III. Instance
This section uses an instance to introduce the scheme planning and commissioning procedure.

Plan the IP address of the Ethernet port in the local Ethernet network as 10.11.100.1 and the subnet mask as 255.255.255.0. Plan the IP address of the WAN port as 133.133.133.1 and the subnet mask as 255.255.255.252. Plan the destination network segment of the static route as 10.11.1.0, subnet mask as 255.255.255.0 and next hop IP address as 133.133.133.2.

IV. Installing and Connecting Hardware


Install the router according to Quidway 3640 Installation Manual. Figure 1.1shows how to connect Quidway 3640 with peripheral devices.

Figure 1.1 Connecting Quidway 3640

3.6.4 Procedure
According to the planning in 3.6.3IIIInstance, configure Quidway 3640 as follows:

I. Configuring HyperTerminaling
1) 2) Use the configuration cable delivered with Quidway 3640 to connect port CONSOLE on it and the serial port on the PC. Run the HyperTerminal program, and set up a connection. Use the serial port connection, and set the communications parameters as: 9600 bit/s, no parity
Huawei Technologies Proprietary 38

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

check, one stop bit, flow control as Xon/Xoff. 3) Switch on Quidway 3640, and HyperTerminal displays the self-check information about Quidway 3640. When the self-check is complete, the system prompts you to press Enter. 4) Press Enter, and the system enters the Router state.

II. Configuring Routering


You can configure the Quidway 3640 series routers in two ways:

The setup mode The command line mode

This section describes how to use the command line to configure the router.

Note: The system prompts to configure the router in the setup mode on the first boot. You can also execute the command setup to enter the setup mode, as follows: [Quidway] setup

The detailed procedure for configuring Quidway 3640 is as follows: 1) Log in to the router.

Switch on the router, and the system carries out the self-check. When the self-check is complete, the system enters the system view, namely, the Router state. 2) Set the system name as the prompter.

[Quidway] sysname 3) Set the IP address and subnet mask for the Ethernet port. //Enter the mode for configuring the specified

[Router] interface ethernet 0 Ethernet port E0.

[Router-Ethernet0] ip address 10.11.100.1 255.255.255.0 //Reset the IP address and mask for E0. 4) Set the WAN port cE1/PRI. //Set the E1 port with the number as 0.

[Router] controller e1 0

[Router-E1-0] code ami | hdb3 //Set the line code format to AMI or HDB3. The system default setting is HDB3. [Router-E1-0] using e1|ce1 //The cE1/PRI port works in the E1 or cE1/PRI mode. The system default setting is the cE1 mode. [Router-E1-0] frame-format crc4 // Set the frame check mode of the cE1/PRI port to the 4-byte CRC. You can also set not to use the CRC.
Huawei Technologies Proprietary 39

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

Note: Set whether to use the CRC according to the specific network communications requirements. If the Mercury 3600 that communicates with the router uses the CRC, set the CRC for the router; otherwise, do not.

[Router-E1-0] channel-set 1 timeslot-list 1-4 //Define that channel set 1 binds timeslots 1, 2, 3 and 4.

Note: Timeslot 0 is usually not involved in the channel definition. It is used for synchronizing the clock during the line communications. Therefore, the timeslot binding starts from timeslot 1.

5)

Set the virtual serial port.

[Router-E1-0] interface serial 0:1 [Router-Serial0:1] ip address 133.133.133.1 255.255.255.252 [Router-Serial0:1] link-protocol ppp [Router-Serial0:1] quit 6) Set the static route.

If the set static route does not meet the actual requirements, execute the following corresponding commands to modify it: [Router] ip route-static 10.11.1.0 255.255.255.0 133.133.133.2 route. 7) Save the setting and check the configuration. //Reset the static

Press Ctrl+Z to go back to the prompter Router. [Router] save //Save the configuration into the flash memory. [Router] display cur //Display the configuration.

III. Checking Configuration and Debugging Systemand debugging


When the router configuration at both sides of the network is complete, carry out the system debugging as follows: 1) Display the status of the WAN port serial 0.

When the router configuration is complete at both sides of the network, execute the
Huawei Technologies Proprietary 40

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 3 Commissioning of O&M Network

following command on any router to display the S0 status: [Router] display interface serial 0 The displayed port information includes:

Physical status of the port and protocol status Physical characteristics of the port, such as synchronous/asynchronous, DTE/DCE, selected clock, baud rate and external cables IP address of the port Link layer protocols encapsulated on the port and their running status and statistics Input/output message statistics. Check the remote network.

2)

Execute ping to check whether the remote network is connected. [Router] ping xxx.xxx.xxx.xxx (IP of Ethernet0/0 on the peer-end router) If you can ping the port, it shows that the configuration is correct and the network is usable. Otherwise, check the configuration and the network connection. You can use the self-loop to check if the communication problem is caused by faulty links. Check further the router configuration, including the IP address, mask, static route, protocol encapsulated on the WAN port, the corresponding timeslot, and the extracted clock. Locate the problem, and ensure that you can ping the peer-end LAN successfully.

Huawei Technologies Proprietary 41

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Chapter 4 Access of NEs to M2000


4.1 About This Manual
To access NEs to the M2000 means to access NEs to the M2000 O&M system. In this way, you can operate on and maintain all the NEs through the M2000. Before giving NEs access to the M2000, the NEs are debugged and they work properly. This chapter introduces the order to access various NEs into the M2000 system, and describes how to install the NE mediation software, create NEs and verify functions of each interface.

4.2 Before Access


Before accessing NEs to the M2000: 1) Check if the connection between the M2000 system and the NEs to access is normal. Execute the following command on the M2000 server:

ping <NE IP>


If the connection is normal, the NE responds to the ping command. 2) Prepare the mediation installation package for these NEs.

For example, the mediation installation package for the M2000V200R002C02B006 UMG is iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar. 3) Check the running status of M2000 services.

Log in to the M2000 server as root, and then execute the following command: # svc_adm -cmd status In normal circumstances, the information returned by the system contains [Not Runing : 0 ]. This shows that all the M2000 services are started. 4) Check the running status of the high availability (HA) system, if any.

Log in to any of the two M2000 servers as root, and then execute the following command: # scstat In normal circumstances, the system returns the following information:

Cluster Nodes: Both two nodes are online. Cluster Transport Paths: There are two transport paths, and both are online. Quorum Votes by Node: Both nodes are online.
Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System


Chapter 4 Access of NEs to M2000

Quorum Votes by Device: The device is online. Device Group Servers: The active server configured by the device group ossdg is the active node, and the standby server is the standby node. Device Group Status: The device group ossdg is online. Resource Groups and Resources: The resource group oss_rg contains resources such as osssvr, ossdg_rs, sybase_rs and ossapp_rs. Resource Groups: oss_rg is online on the active node and offline on the standby node. Resources: All resources are online on the active node and offline on the standby node. If the system is installed with two tape drives, rmt/1 and rmt/2 are displayed, both in offline status.

4.3 Access Procedure


Table 1.1 shows the procedure for accessing an NE to the M2000 system. Table 1.1 NE access procedure Step 1 Action Install the mediation software of the NE on the M2000 server. 2 Create the NE in the topology tree on the M2000 client. 3 Check the alarm management interface between the M2000 and the NE. 4 Check the performance management interface between the M2000 and the NE. 4.6Checking Alarm Data Reporting 4.7Checking Performance Data Reporting 5 Check the backup interface between the M2000 and the NE. 6 Check the log management interface between the M2000 and the NE. 7 Create an NE user for the NE on the M2000 client. 8 Check the MML command interface between the M2000 and the NE. 4.11Checking MML Command Delivery 4.8Checking NE Data Backing Up 4.9Checking NE Log Uploading 4.10Adding NE Users Reference 4.4Installing NE Mediation Software 4.5Creating an NE

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Step 9

Action Check the LMT interface between the M2000 and the NE.

Reference 4.12Checking LMT

4.4 Installing NE Mediation Software


4.4.1 Introduction to NE Mediation Software
The M2000 software includes the common software and the mediation software. The common software provides basic M2000 functions, and the mediation software mediates various types of NEs to cover them in the M2000 system for uniform management. Install the mediation software separately after the M2000 common software is installed and starts working properly. The mediation software installation package is provided based on the NE version. Execute the installation package on the M2000 server. When the mediation software is installed, start the M2000 client, and the system automatically downloads relevant information to the client from the M2000 server. The installation of the different type NE mediation is the same.

4.4.2 Preparing Installation Files


Download the mediation software installation package for the NE to be accessed from the website, and then upload it to the M2000 server as follows: 1) Create the installation package directory /export/home/mediation.

Log in to the M2000 server as user root, and then execute the following command: # mkdir -p /export/home/mediation 2) Upload the installation package in the bin mode to /export/home/mediation through FTP. For example, copy the mediation software installation package for the UMG iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar to the M2000 client, and then upload it in the bin mode to /export/home/mediation on the M2000 server through FTP.

4.4.3 Stopping M2000 Services and Collector


Before installing the mediation software, ensure to stop the M2000 services and Collector. The stopping procedure in the single server system is different from that in the high availability (HA) system, as described in the following.
Huawei Technologies Proprietary 3

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

I. In Signle Server System


Log in to the M2000 server as root, and then execute the following command: 1) Set the work environment for the M2000 system.

# cd /opt/OMC # . ./svc_profile.sh 2) Stop all M2000 services.

# stop_svc 3) Check over the M2000 services to ensure that all the services are stopped.

# svc_ps If there is an output for this command, execute kill_svc to stop all the services forcibly. Repeat these operations until there is no output after you execute svc_ps. 4) Stop Collector.

# /opt/OMC/bin/stop_collector

II. In HA System
Log in to the active node as root, and then execute the following command: 1) Set the work environment for the M2000 system.

# cd /opt/OMC # . ./svc_profile.sh 2) Stop all M2000 services.

# scswitch -n -j ossapp_rs 3) Check over the M2000 services to ensure that all the services are stopped.

# svc_ps If there is an output for this command, execute kill_svc to stop all the services forcibly. Repeat these operations until there is no output after you execute svc_ps. 4) Stop Collector.

# /opt/OMC/bin/stop_collector

4.4.4 Installing Mediation Software


The installation of the mediation software varies according to the type of the NE. This section takes the installation of iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar for the MGW as an example to describe the installation procedure. For other versions of MGW's or other types of NEs, the only difference lies in the name of the mediation software installation package.

Huawei Technologies Proprietary 4

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Log in to the active node as root, and then carry out the following operations: 1) Set the work environment for the M2000 system.

# cd /opt/OMC # . ./svc_profile.sh 2) Decompress the mediation software installation package.

# cd /export/home/mediation # tar xf iManagerM2000_UMG_MATCH_ENG_V200R002C02B006.tar The system generates a directory named install mediation automatically. 3) Install the mediation software.

# cd /export/home/mediation/installmediation # ./install.sh The following information is displayed for you to confirm:


the Install NE Type is : MGWNE the Install NE Version is : UMG8900V200R003C01B053 the Install Match Version is : iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 Environment variable M2K_ROOT is : /opt/OMC

Are you sure to continue? [y/n]

Enter y to start the installation, and enter any other character to exit the installation. 4) If this version of mediation software is installed for the first time, the installer completes the whole installation. If already installed, the installer prompts you to decide whether to overwrite the existing version.
The MGWNE iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 mediation has been created! Do you want to overwrite it? [y/n]

In this case, enter "y" to uninstall the existing version, and then reinstall this version of mediation software. Enter any other character to exit the installation. Note to check words such as "error" or fail in the output returned by the system. If displayed, contact Huawei. Logs for the installation process are recorded into the file /var/med_install.sh.

4.4.5 Displaying Mediation Software Version


After installing the mediation software, carry out the following operations to display the mediation software version and to check the whole system. Log in to the active node as root, and then carry out the following operations:
Huawei Technologies Proprietary 5

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

1)

Set the work environment for the M2000 system.

# cd /opt/OMC # . ./svc_profile.sh 2) Display the version information.

Take the MGW for example. # displayVersion -ne MGW // Check the output for the following information:
<MGW> Match Version : iManagerM2000_UMG_MATCH_ENG_V200R002C02B006 NE Version : UMG8900V200R003C01B053

If the screen displays the above information, it shows that the mediation version is copied correctly. In this case, you can restart the M2000 client to create NEs . If it is not contained in the output, you should reinstall the mediation software. Check the following path to ensure that it is the correct installation for the M2000:
Environment variable M2K_ROOT is /opt/OMC.

If the installation path is correct, and if you still fail to install the mediation software, contact Huawei.

4.4.6 Restarting M2000 Services and Collector


Before installing the mediation software, you should stop M2000 services and Collector. Restart them when the installation is complete. The startup procedure in the single server system is different from that in the HA system, as described in the following.

I. In Single Server System


Log in to the M2000 server as root, and then execute the following command: 1) Start M2000 services.

# start_svc You can open a Telnet window to log in to the server when the M2000 services are starting. To monitor the startup process, execute the following command: # tail -f /opt/OMC/startsvc.log When all the M2000 services are started about 10 minutes later, close this Telnet window. 2) Start Collector.

# /opt/OMC/bin/start_collector

Huawei Technologies Proprietary 6

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

II. In HA System
Log in to the active node as root, and then carry out the following operations: 1) Start M2000 services.

# scswitch -e -j ossapp_rs 2) Start Collector.

# /opt/OMC/bin/start_collector

4.5 Creating an NE
4.5.1 Creating a UMTS NE
I. Description
Create a UMTS NE in the topology tree on the M2000 client. After the NE is created, the M2000 generates management objects for this NE. Through the automatic synchronization with the NE, the M2000 obtains the NE configuration, and then saves it into the M2000 database. In addition, maintenance channels are established between the M2000 and the UMTS NE to enable the M2000 server to manage the UMTS NE.

II. Prerequisites
Before creating the UMTS NE, ensure that:

The connection between the M2000 system and the UMTS NE is normal. M2000 services are working properly. The mediation software for the UMTS NE is installed successfully on the server. The UMTS & GSM option is selected during the installation of the M2000 client. The M2000 is authorized to manage the UMTS and GSM NEs.

III. Procedure
All UMTS NEs except Node B are created on the M2000 client in the same procedure. Take the RNC creation for example, and the procedure is as follows: 1) Select the subnet.

Plan the location of the RNC in the topology tree and the subnet it belongs to.

If the subnet with the NE does not exist in the topology tree, you should create the subnet. Right-click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose the subnet in the topology tree.

If the subnet with the NE already exists, choose the subnet in the topology tree. Create the RNC.

2)

Huawei Technologies Proprietary 7

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Right-click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select Access Network Series as the category and RNC as the NE type, and then click Next. Enter the name and IP address of the NE, and then click Finish. Figure 2.1 shows the process for creating the RNC.

Figure 2.1 Creating RNC 3) Carry out the automatic synchronization.

After creating the NE, a corresponding icon is displayed on the topology tree for the NE. If both the physical and logical connection between the NE and the M2000 works properly, the M2000 synchronizes data with the NE to obtain the NE configuration. The synchronization status is displayed in the topology tree. 4) Set the file server.

Choose Software > File Server Setting, and then select the NE type in the navigation tree in the left part of the displayed window. In this example, select RNC. In the right part window, select the created NE and the name of its file server. You can select the OMC or the RNC itself as the file server for the created RNC NE (OMC refers to the M2000). If there is a firewall between the RNC and the OMC, you must select OMC as the file server. It is the same case with other NEs. Now, the creation of the UMTS NE is complete. The M2000 can obtain automatically the default performance data, alarm and log information of the NE.

4.5.2 Creating a GSM NE


I. Description
Create a GSM NE in the topology tree on the M2000 client.

Huawei Technologies Proprietary 8

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

The M2000 generates a management object for the UMTS NE, gets the configuration information by synchronization with the NE, and saves it in the M2000 database. In addition, the M2000 sets up maintenance channels with the NE and has it managed.

II. Prerequisites
Before creating a GSM NE, ensure that:

The physical and logical connections between the M2000 system and NEs work properly. M2000 services are working properly. The mediation software for the NE is installed successfully on the server. The UMTS & GSM option is selected during the installation of the M2000 client. The user account with the required privileges is created on the NE BAM.

Note: Access the NE from the M2000 client with the user account to obtain the NE data. While creating the NE on the M2000 client, you should also enter the username and password. Ensure that they are the same as those set on the NE. See the NE user manual to create the user account on the NE BAM.

III. Procedure
All GMS NEs are created on the M2000 client in the same procedure. Take the BSC creation for example, the procedure is as follows: 1) Select the subnet.

Plan the location of the BSC in the topology tree and the subnet it belongs to.

If the subnet with the NE does not exist in the topology tree, you should create the subnet. Right-click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose this subnet in the topology tree.

If the subnet with the NE already exists, choose this subnet in the topology tree. Create the BSC.

2)

Right-click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select Access Network Series as the category and BSC as the NE type, and then click Next. Enter the name and IP address of the NE, and the username and password of the account created on the NE BAM, as shown in Figure 2.1. Click Finish.

Huawei Technologies Proprietary 9

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Figure 2.1 Creating BSC (1) Figure 2.2 shows the process for creating the BSC.

Figure 2.2 Creating BSC (2) 3) Carry out the automatic synchronization.

After creating the NE, a corresponding icon is displayed on the topology tree for the NE. If both the physical and logical connection between the NE and the M2000 works properly, the M2000 synchronizes data with the NE to obtain the NE configuration. Meanwhile, the synchronization status is displayed in the topology tree. Now, the creation of the GSM NE is complete. The M2000 can obtain automatically
Huawei Technologies Proprietary 10

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

the default performance data, alarm and log information of the NE.

4.5.3 Creating a CDMA NE


I. Description
Create a CDMA NE in the topology tree on the M2000 client. After the NE is created, the M2000 generates management objects for this NE. Through the automatic synchronization with the NE, the M2000 obtains the NE configuration, and then saves it into the M2000 database. In addition, the M2000 sets up maintenance channels with the NE and has it managed.

II. Prerequisites
Before creating the CDMA NE, ensure that:

The connection between the M2000 system and NEs is normal. M2000 services are working properly. The mediation software for the NE is installed successfully on the server. The CDMA option is selected during the installation of the M2000 client. The user account with the required privileges is created on the NE BAM.

Note: Access the NE from the M2000 client with the user account to obtain the NE data. While creating the NE on the M2000 client, you should also enter the username and password. Ensure that they are the same as those set on the NE. See the NE user manual to create the user account on the NE BAM.

III. Procedure
All CDMA NEs are created on the M2000 client in the same procedure. Take the CMSC creation for example, and the procedure is as follows: 1) Select the subnet.

Plan the location of the CMSC in the topology tree and the subnet it belongs to.

If the subnet with the NE does not exist in the topology tree, you should create the subnet. Right-click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose the subnet in the topology tree.

If the subnet with this NE already exists, choose the subnet in the topology tree. Create the CMSC.

2)

Right-click on the topology tree, and select Create NE on the displayed menu. In the
Huawei Technologies Proprietary 11

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

displayed dialog box, select Core Network Series as the category and CMSC as the NE type, and then click Next. Enter the name and IP address of the NE and the username and password of the account created on the NE BAM, as shown in Figure 2.1. Click Finish.

Figure 2.1 Creating CMSC (1) Figure 2.2 shows the process for creating the CMSC.

Figure 2.2 Creating CMSC (2) 3) Carry out the automatic synchronization.

After creating the NE, a corresponding icon is displayed on the topology tree for the
Huawei Technologies Proprietary 12

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

NE. If both the physical and logical connection between the NE and the M2000 works properly, the M2000 synchronizes data with the NE to obtain the NE configuration. Meanwhile, the synchronization status is displayed in the topology tree. Now, the creation of the CDMA NE is complete. The M2000 can obtain automatically the default performance data, alarm and log information of the NE.

4.5.4 Creating an IP Device


I. Description
Create an IP device in the topology tree on the M2000 client. After the IP device is created, the M2000 generates management objects for the IP device, and saves them into the M2000 database. In addition, the M2000 sets up maintenance channels with the IP device and has it managed.

II. Prerequisites
Before creating an IP device, ensure that:

The connection between the M2000 system and the IP device is normal. M2000 services are working properly. The M2000 authorizes the required privileges for the IP device.

III. Procedure
1) Select the subnet.

Plan the location of the IP device in the topology tree and the subnet it belongs to.

If the subnet with the NE does not exist in the topology tree, you should create the subnet. Right-click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose the subnet in the topology tree.

If the subnet with the NE already exists, choose the subnet in the topology tree. Create the IP device.

2)

Right-click on the topology tree, and select Create NE on the displayed menu. In the displayed dialog box, select IP Device Series as the category and IP Device as the NE type, and then click Next. Enter the name and IP address of the NE, and then click Finish. Now, the creation of the IP device is complete. The M2000 can obtain automatically alarm information of the IP device.

4.5.5 Creating RAN


I. Description
Create a UMTS RAN in the topology tree on the M2000 client.
Huawei Technologies Proprietary 13

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

An RAN contains an RNC and multiple NodeBs in the RNC. After the RAN is created, the M2000 generates management objects for these NEs. Through the automatic synchronization with these NEs, the M2000 obtains the NE configuration, and then saves it into the M2000 database. In addition, the M2000 sets up maintenance channels with the NE and has it managed.

II. Prerequisites
Before creating the RAN, ensure that:

The connection between the M2000 system and NEs in the UMTS RAN is normal. M2000 services are working properly. The mediation software for each NE is installed successfully on the server. Physical channels are set up between the RNC and NodeBs, and the interface data is configured. The UMTS/GSM option is selected during the installation of the M2000 client. The required privileges are obtained.

III. Procedure
An RAN contains an RNC and multiple NodeBs hosted in the RNC. Create the RNC first, and then each NodeB. See 4.5.1IIIProcedure to create the RNC. Creat the NodeBs one by one in the same way as that for the RNC; or create them all at once, as follows: 1) Select the RNC.

Select the RNC with all the NodeBs in the topology tree. 2) Search automatically and create the NodeBs.

Right-click the RNC node and select Search. The system performs the following operations automatically:

sSearchesing all the NodeBs hosted in the RNC, c reates Creating topological objects forall the searched NodeBs Displaying the topology in the topology view them in the topology tree, and then synchronizes Synchronizing data with these NodeBs. Set the file server.

3)

Choose Software > File Server Setting. Select any NodeB node in the navigation tree in the left part of the displayed window, and the created NodeB NEs are displayed in the right part window. Select the file server for each of them. You can select the OMC or the corresponding RNC as the file server for the created NodeB NE. (The OMC refers to the M2000.) If there is a firewall between the RNC and the OMC, you must select the OMC as the file server.
Huawei Technologies Proprietary 14

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Now, the creation of the UMTS RAN is complete. The M2000 can obtain automatically the default performance data, alarm and log information of the RAN.

4.5.6 Creating NEs in Batches


I. Description
Create multiple NEs in batches in the topology tree on the M2000 client. After these NEs are created, the M2000 generates management objects for these NEs. Through the automatic synchronization with these NEs, the M2000 obtains the NE configuration, and then saves it into the M2000 database. In addition, the M2000 sets up maintenance channels with the NE and has it managed. This applies only to the UMTS NEs, but not the GSM or CDMA NEs.

II. Prerequisites
Before creating NEs in batches, ensure that:

The connection between the M2000 system and NEs is normal. M2000 services are working properly. The mediation software for each NE is installed successfully on the server. The UMTS/GSM option is selection during the installation of the M2000 client. The required privileges are obtained.

III. Procedure
Create multiple NEs in batches on the M2000 client as follows: 1) Edit the file for creating NEs in batches.

Create a CSV template for creating NEs in batches. Open the template, enter the NE information, and then save the file. For specifications on the NE template, see M2000 Operation Manual. 2) Select the subnet.

Plan the location of these NEs in the topology tree and the subnets they belong to.

If the subnet with the NE does not exist in the topology tree, you should create the subnet. Right-click on the topology tree, and then select Create Physical Subnet. In the displayed dialog box, enter the subnet name, and then choose the subnet in the topology tree.

If the subnet with this NE already exists, choose the subnet in the topology tree. Import the file for creating NEs in batches.

3)

Right-click on the topology tree and select Create Physical NEs in batches . In the displayed dialog box, select a CSV file containing information of NEs to be created in batches. Click OK, and the system creates automatically all NEs defined in the file. After the creation of multiple NEs in batches is complete, the M2000 obtains the
Huawei Technologies Proprietary 15

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

default performance data, alarm and log information of these NEs automatically.

4.6 Checking Alarm Data Reporting


I. Description
Once created, the NE reports the alarm information to the M2000, so that you can browse the information on the M2000 client. You cannot view the NE alarm information if the NE access fails or the M2000 and the NE do not match in the alarm interface. Checking the alarm data reporting means to ensure that the NE is accessed correctly, the alarm interface between the M2000 and the NE works properly, and that the software version matches.

II. Prerequisites
Before checking the function, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.

III. Procedure
Log in to the M2000 client and the NE LMT, and then carry out the following operations: 1) Open the M2000 alarm browser.

On the M2000 client, choose Fault > Current Fault Alarm Browser to display Alarm Browse, Query and Statistics. 2) View the current alarm.

Select the NE and click Apply, and the system displays the alarm information in a dialog box as shown in Figure 2.1.

Huawei Technologies Proprietary 16

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Figure 2.1 Displaying alarm information 3) Generate an alarm on the NE.

Pull out a trunk cable, and the LMT for the NE displays the trunk alarm. 4) Ensure that you can view the alarm on the M2000.

Open the window for displaying the alarm information. In normal circumstances, it shows the alarm information on the NE.

4.7 Checking Performance Data Reporting


I. Description
After an NE is created, the NE reports the default performance data to the M2000, so that you can browse it on the M2000 client. You cannot view the performance data on the M2000 client if the NE access fails or the M2000 and the NE do not match in the performance interface. Checking the performance data reporting means to ensure that the NE is accessed correctly, the performance interface between the M2000 and the NE works properly, and that the software version matches.

II. Prerequisites
Before checking the function, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.

Huawei Technologies Proprietary 17

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

III. Procedure
Log in the M2000 client as admin, and then carry out the following operations: 1) Open the M2000 performance query window.

On the M2000 client, choose Performance > Query Result to display Query Result. 2) Set query conditions.

Click New Query to display Query. In the navigation tree on the left, select the NE and the involved measurement sets; in the right part window, select objects (limited to only available objects in the system), counters and measurement period. Click Query. The queried results are shown in Figure 2.1

Figure 2.1 Querying performance information 3) Ensure that you can view the performance data on the M2000 client.

In normal circumstances, the system displays the performance data in Query Result after you define the measurement period.

4.8 Checking NE Data Backing Up


I. Description
When a UMTS NE is created, the M2000 backs up the NE data through the NE data backup function of the software management interface. If the NE data is backed up successfully, it shows that the NE is accessed correctly, the NE data backup function of the software management interface between the M2000 and the NE works properly, and that the software version matches. At present, the M2000 can back up data of only UMTS NEs instead of GSM and
Huawei Technologies Proprietary 18

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

CDMA NEs.

II. Prerequisites
Before checking the function, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.

III. Procedure
Log in the M2000 client as admin, and then carry out the following operations: 1) Open the M2000 manual backup window.

On the M2000 client, choose Tools > System Backup > Manual Backup to display Manual Backup, as shown in Figure 1.1.

Figure 1.1 Manual backup 2) Select the NE you want to back up.

Select NE, and select the accessed NE, and then click Start. In the displayed dialog box, click Yes, and the system displays Backup Browser. 3) Observe the backup progress.

The lower part of Backup Browser shows the backup progress. In normal circumstances, the progress changes from 0% to 100%. 4) Ensure that the M2000 backs up the NE data.

When the backup progress reaches 100%, select Backup List. In normal circumstances, you can see data files of the backed-up NE.
Huawei Technologies Proprietary 19

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

4.9 Checking NE Log Uploading


I. Description
When a UMTS NE is created, the M2000 obtains the NE logs through the NE log uploading function of the software management interface. If the NE log uploading is successful, it shows that the NE is accessed correctly, the NE log uploading function of the software management interface between the M2000 and the NE works properly, and that the software version matches. At present, only logs of UMTS NEs can be uploaded to the M2000. Logs of GSM and CDMA NEs cannot be uploaded.

II. Prerequisites
Before checking the information, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.

III. Procedure
Log in the M2000 client as admin, and then carry out the following operations: 1) Synchronize NE logs.

On the M2000 client, right-click the NE in the topology tree, and then select Synchronize NE Log. 2) Open Software Browser.

On the M2000 client, choose Software > Browser to display Software Bowser. 3) Observe the upload progress.

The lower part of Software Browser shows the progress for uploading the NE logs. In normal circumstances, the progress changes from 0% to 100%. 4) Check the NE logs on the M2000 client.

When the progress reaches 100%, choose System > Log Management > Log Query and Statistic on the M2000 client. In the displayed Log Management, choose NE Log under Log Query in the navigation tree, and select the NE in Filter Condition, and then click Query, as shown in Figure 4.1

Huawei Technologies Proprietary 20

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Figure 4.1 Querying NE logs In normal circumstances, logs of the NE are displayed in the lower part of Log Management.

4.10 Adding NE Users


I. Description
Adding NE users means to create users for a specified NE and authorize them the authority for MML command groups. In this way, they can execute MML commands of the NE and run the LMT. At present, you can add NE users for UMTS NEs only.

II. Prerequisites
Before adding an NE user, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system.

III. Procedure
Log in the M2000 client as admin, and then carry out the following operations: 1) Open Security Management.

On the M2000 client, choose System > Security Management to display Security Management. 2) Create an NE user.

Right-click the NE in the navigation tree on the left, and then select Add NE User to
Huawei Technologies Proprietary 21

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

display Add NE User. Select the user account from the list, and then click OK. The system binds the M2000 user account to the NE, so that the user becomes NE user. 3) Bind command groups.

In the navigation tree on the left, right-click the created NE user under the node User, and select Bind NE to display Bind User to NE. Select command groups from the list on the right and then click OK, so that the user can execute commands in these command groups, as shown in Figure 3.1.

Figure 3.1 Binding NE user to command groups Now, an NE user is added successfully. Use the user account to log in, and ensure that you can execute MML commands and start the LMT of the NE.

4.11 Checking MML Command Delivery


I. Description
After creating the NE and adding the NE user, deliver MML commands on the NE through the MML command window on the M2000 client. Checking MML command delivery means to ensure that the NE is accessed correctly, the NE user is added successfully, the security management interface between the M2000 and the NE works properly, and that the software version matches.

II. Prerequisites
Before checking this function, ensure that:

The NE is successfully created in the M2000 system.

Huawei Technologies Proprietary 22

Commissioning Guide iManager M2000 Mobile Element Management System


Chapter 4 Access of NEs to M2000

The NE in the topology tree is connected with the M2000 system. Users are added for the NE.

III. Procedure
Log in the M2000 client as the user bound to the NE, and then carry out the following operations: 1) Open MML Command.

Choose Configuration > MML Command to display MML Command, as shown in Figure 1.1.

Figure 1.1 MML command 2) Obtain information about MML commands for the NE.

In the navigation tree in the upper part window, select the NE, and the system obtains MML command file automatically for the NE. 3) Execute MML commands.

In the lower part window in Figure 3.1, enter the MML command, and the system displays the returned information in the upper part window. For example, enter LST EMS for RNC NEs, and the system displays information about the M2000 operator.

Huawei Technologies Proprietary 23

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

Figure 3.1 Responding to MML command In normal circumstances, the NE responds to the delivered MML command.

4.12 Checking LMT


I. Description
After creating the NE and add the NE user, you can start the LMT of the NE on the M2000 client. Checking the LMT means to ensure that the NE is accessed correctly, the NE user is added successfully, the security management interface between the M2000 and the NE works properly, and that the software version matches. At present, you can start the LMT for UMTS NEs only. GSM and CDMA NEs do not support this function.

II. Prerequisites
Before checking the function, ensure that:

The NE is successfully created in the M2000 system. The NE in the topology tree is connected with the M2000 system. Users are added for the NE. The LMT software of the NE is installed on the PC, and the LMT version matches the NE version.

III. Procedure
Log in the M2000 client as the user bound to the NE, and then carry out the following operations:

Huawei Technologies Proprietary 24

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 4 Access of NEs to M2000

1)

Start the LMT.

In the topology tree, right-click the NE and select Maintenance Client to display the local maintenance system of the NE.

Note:

For the non-GSM NE, the LMT provides only one operation menu, namely, For the GSM NE, the LMT provides multiple operation menus, such as Traffic

[Maintenance].

Statistics, Data Management. In addition, the LMT provides different operation menus for different GSM NEs.

2)

Log in the LMT.

Log in the LMT as the NE user. In normal circumstances, you can start and log in to the NE LMT on the M2000 client automatically as the NE user. No extra username or password is necessary.

Huawei Technologies Proprietary 25

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Chapter 5 Commissioning of Remote Alarm Notification Service


5.1 About This Chapter
This chapter introduces the remote alarm notification service and describes how to commission the remote alarm notification service.

5.2 Introduction to Remote Alarm Notification


5.2.1 Introduction to Remote Alarm Notification Service
The M2000 provides the remote alarm notification service. Through this service, the system delivers real time alarm information to you by short messages, over telephone or by e-mails.

5.2.2 Introduction to Alarm-Notification-over-BP/Telephone


Alarm-Notification-over-BP/Telephone is a function based on the remote alarm notification service provided by the M2000. Through this function, you can get the real time alarm information over BP/telephone. That is, when an alarm occurs, your BP beeps and displays the alarm information, or your fixed phone rings. You can set in the system that which alarms trigger your BP or telephone. To use this function, you should connect the M2000 server or client to the PSTN network through a wired Modem.

5.2.3 Introduction to Alarm-Notification-by-Short-Messages


Alarm-Notification-by-Short-Messages is a function based on the remote alarm notification service provided by the M2000. Through this function, you can get the real time alarm information in short messages over your cell phone. That is, when an alarm occurs, you receive a short message on your cell phone showing the alarm information. You can set in the system that information about which alarms is sent to your cell phone in short messages. To use this function, you should connect the M2000 client to the PSTN network through a wireless Modem.

Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

5.2.4 Introduction to Alarm-Notification-by-E-mail


Alarm-Notification-by-e-mail is a function based on the remote alarm notification service provided by the M2000. Through this function, you can get the real time alarm information by e-mails. That is, when an alarm occurs, you receive an e-mail in your e-mail box showing the alarm information. You can set in the system that information about which alarms is sent to your Email box in e-mails. To use this function, you should connect the M2000 system to the SMTP server of the Internet.

5.3 Commissioning Alarm-Notification-over-BP/Telephone


5.3.1 Commissioning Procedure
Figure 1.1 shows the procedure for commissioning Alarm-Notification-overBP/Telephone.

Figure 1.1 Procedure for commissioning Alarm-Notification-over-BP/Telephone Table 1.1 describes this procedure in detail.

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Table 1.1 Description of the procedure for commissioning Alarm-Notification-overBP/Telephone No. 1 Install a wired Modem. Install an internal wired Modem. Step Install an external wired Modem. Reference 5.3.2Installing External Wired Modem 5.3.3Installing Internal Wired Modem Description You can install the Modem on the server or the client. The latter is recommended. The M2000 system needs only one Modem for AlarmNotification-over BP/Telephone. 2 Commission the Modem. Commission the server side Modem. Commission the client side Modem. 3 Configure related parameters. 5.3.4Commission ing Server Side Modem 5.3.5Commission ing Client Side Modem 5.3.6Configuring Parameters for AlarmNotification-overBP/Telephone 4 Check this function. 5.3.7Checking AlarmNotification-overBP/Telephone The server and the client use different operating systems. Accordingly, the procedure for commissioning the Modem varies. Configure parameters for this function on the client.

5.3.2 Installing External Wired Modem


You can install the external wired Modem on the M2000 server (the Sun server) or the client (the PC).

Huawei Technologies Proprietary 3

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

I. Checking Serial Ports

To install the Modem on the server

Serial port A and serial port B on some types of Sun servers refer to the same physical serial port, for example, Sun Fire V880 and Sun Fire V890 servers. Ensure not to connect two devices on these two ports at the same time. For example, avoid connecting wired and wireless Modems at the same time.

To install the Modem on the client

Before installing any hardware, ensure to shut down the M2000 client. Check whether there is an alarm box connected to the client. If so, specify the number of the serial port occupied by the alarm box. Ensure to connect the Modem to an unused serial port. To view the serial port used by the alarm box, check the value of PortName in the file <Installation <PARA name="PortName" directory value="COM1" of For M2000 example, client>\style\defaultstyle\conf\alarmclient\alarmboxconfig.xml . connected on serial port COM1.

/> shows that the alarm box is

Note: If the M2000 client has only one serial port and the port is connected to an alarm box, disconnect the alarm box from the client, and modify the value of PortName to an inexistent serial port, such as COM10, to install the Modem.

If the system is not installed with an alarm box, modify the value of PortName to an inexistent serial port, such as COM10.

II. Installing Modem


Install an external wired Modem as follows: 1) Connect the serial port cable.

Use the serial port cable delivered with the Modem to connect the Modem to the M2000 server or client. One end connects the Modem, and the other connects the serial port on the M2000 server or client.

Huawei Technologies Proprietary 4

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Note: Use a connector if the interface of the serial port cable is different from the serial port on the M2000 server or client.

2)

Connect the power cable.

Use the DC power cable delivered with the Modem. For details on connecting the power cable, see the Specifications delivered with the Modem. 3) Connect the telephone line.

Connect the telephone line to port Line on the Modem. For details, see the Specifications delivered with the Modem. 4) Install the Modem driver.

See the Specifications delivered with the Modem to install the Modem driver.

5.3.3 Installing Internal Wired Modem


You can only install the internal wired Modem on the M2000 client, namely, the PC. Before installing any hardware, ensure to shut down the M2000 client. Install the internal wired Modem as follows: 1) 2) 3) Switch off the PC. Open the PC chassis. Insert the Modem into the PCI slot.

Choose an available PCI slot and open the cover over it. Insert the Modem into the slot, and ensure that the gilded joint part of the Modem is pressed tightly into the PCI slot. Close the cover to fix the Modem in the slot. 4) Connect the telephone line.

Connect the telephone line to port line on the Modem. For details, see the Specifications delivered with the Modem. 5) 6) Close the PC chassis. Install the Modem driver.

See the Specifications delivered with the Modem to install the Modem driver.

5.3.4 Commissioning Server Side Modem


On the server side, you can only install an external Modem. Commission it as follows: 1) 2) Switch on the Modem, and it carries out initialization automatically. Log in to the Solaris operating system of the M2000 server as root.

Huawei Technologies Proprietary 5

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

3)

Enable the serial port, and set the baud rate.

Execute tip -9600 /dev/term/a to enable the serial port and set the baud rate.
connected

In this command, 9600 is the baud rate, and /dev/term/a stands for serial port A. 4) Ensure that the Modem works properly.

Execute the command at to check the Modem.


OK

If the system returns OK, it shows that the Modem is connected properly. 5) Try a number to test the dialing.

Execute atdt88812345 to check the dialing.


OK

If the system returns OK, it shows that the dialing works properly. 6) Stop the dialing.

Execute the command ath to stop the dialing.


OK

7)

Exit the tip command.

Execute ~. to exit tip.


[EOT]

If you fail to exit the tip command after enter ~., press Enter, and then enter ~..

5.3.5 Commissioning Client Side Modem


You can install an external or internal Modem on the M2000 client. Commission the Modem on the client as follows: 1) 2) 3) 4) Switch on the external Modem, and it carries out initialization automatically. If an internal Modem is installed, you do not need to switch on the Modem. Log in the Windows operating system of the M2000 client as administrator. Choose Start > Programs (P) > Accessories > Communications > HyperTerminal to start HyperTerminal. Set up a connection. Enter the connection name, such as modem, as shown in Figure 4.1, and then click OK.

Huawei Technologies Proprietary 6

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Figure 4.1 Setting up a connection 5) Select the serial port for connection. For example, select COM1, as shown in Figure 5.1, and then click OK.

Figure 5.1 Selecting a serial port 6) Set attributes of the serial port according to Figure 6.1, and then click OK.

Huawei Technologies Proprietary 7

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Figure 6.1 Setting serial port attributes 7) In Figure 7.1, enter the command at for commissioning the dialing.

Figure 7.1 Commissioning the dialing


OK

Huawei Technologies Proprietary 8

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

If the system returns OK, it shows that the Modem is connected properly. 8)
OK

Execute atdt88812345 to try a number to test the dialing.

If the system returns OK, it shows that the dialing works properly. 9)
OK

Execute ath to stop the dialing.

10) Shut down HyperTerminal.

5.3.6 Configuring Parameters for Alarm-Notification-over-BP/Telephone


You can install the Modem on the M2000 server or client (the PC). Configure the parameters for Alarm-Notification-over-BP/Telephone only on the client (the PC). Configure the parameters as follows: 1) Log in to the M2000 client as admin or the user that has the authority to set the remote alarm notification.

Huawei Technologies Proprietary 9

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Note: After installing the Modem on the client, log in to the client as admin or a user that has the authority to set the remote alarm notification, and keep this client running. The alarm notification is deactivated if you shut down the client or log in to the client as any other user account. Ensure that the parameter RemoteNotifyEventProcessor in the file <M2000 installation directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml is not commented.

2)

Choose Fault > Fault Service Settings. In Remote Notify, enter the user name and the phone or page number, select the alarms to send, and then click Add to add a record of user information for receiving remote alarm notification.

3) 4)

In the User Information field, click Setting. In the displayed Remote notify detail settings, select Phone pager. Select Activate, and enter parameters such as Serial port and Send point. Click Set.

Note: If you select Send by client as Send point, ensure to select Current client can be used for phone or pager on only one client. Otherwise, the same alarm notification may be sent many times.

5)

Enter the telephone number behind Test phoneNo or pagerNo, such as 862187654321, and then click Test. In the displayed Test, the M2000 drives the wired Modem to dial this number. If everything is normal, the system prompts that the dialing is successful. Otherwise, the system prompts a failure message. In this case, check the configuration.

6)

Click Close to close Remote notify detail settings.

5.3.7 Checking Alarm-Notification-over-BP/Telephone


After installing the Modem, create an alarm manually to check Alarm-Notificationover-BP/Telephone. To create an alarm manually, perform the following steps:: 1) 2) Connect the telephone, and ensure that it works properly. In Remote Notify, select a record of user information, and then set to receive the check alarm. For example, select an alarm with the NE type as OMC, such
Huawei Technologies Proprietary 10

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

as CPUAlarm--1, and then click Modify. 3) 4) Choose Tools > System Monitor > Configurations to display System Monitor Configurations. Modify the CPU and memory used rate. For example, set both the CPU and memory used rate to 2. The system generates an alarm when the CPU and memory used rate exceeds this value. Wait until the alarm board prompts the alarm. In normal cases, the phone rings or the pager beeps with three ringing tones for the system alarm. It displays the calling number if it subscribes to the Caller ID Display (CID) function. When the test is complete, restore the settings. If error occurs, check and ensure that the Modem works properly, that parameters are configured correctly, and that the service RemoteNotifyService is running on the server.

5.4 Commissioning Alarm-Notification-by-Short-Messages


5.4.1 Commissioning Procedure
Figure 1.1 shows the procedure for commissioning Alarm-Notification-by-ShortMessages.
Start

Install wireless modem

Commission wireless modem

Configure related parameters

Check Alarm-Notification-by-Short-Messages

End

Figure 1.1 Procedure for commissioning Alarm-Notification-by-Short-Messages Table 1.1 describes this procedure in detail.

Huawei Technologies Proprietary 11

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Table 1.1 Description of the procedure for commissioning Alarm-Notification-byShort-Messages No. 1 Step Install the wireless Modem. Reference 5.4.2Installing Wireless Modem Description You can install the Modem on the client. The M2000 system needs only one Modem for Alarm-Notification-by Short/Messages. 2 Commission the wireless Modem. 5.4.3Commissioning Wireless Modem None.

Configure related parameters.

5.4.4Configuring Parameters for Alarm-Notificationby-Short-Messages

Configure parameters for this function on the client.

Check this function.

5.4.5Checking Alarm-Notificationby-Short-Messages

None.

5.4.2 Installing Wireless Modem


The 38 Kbps Modem supports the wireless GSM/GPRS. Install the Modem on the M2000 client (the PC).

I. Checking Serial Ports


Before installing any hardware, ensure to shut down the M2000 client. Check whether there is an alarm box connected to the client. If so, specify the number of the serial port occupied by the alarm box. Ensure to connect the Modem to an unused serial port. To view the serial port used by the alarm box, check the value of PortName in the file <Installation <PARA name="PortName" directory value="COM1" of For M2000 example, client>\style\defaultstyle\conf\alarmclient\alarmboxconfig.xml .

/> shows that the alarm box is

Huawei Technologies Proprietary 12

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

connected on serial port COM1. Note: If the M2000 client has only one serial port and the port is connected to an alarm box, disconnect the alarm box from the client, and modify the value of PortName to an inexistent serial port, such as COM10, to install the Modem.

If the system is not installed with an alarm box, modify the value of PortName to an inexistent serial port, such as COM10.

II. Installing Modem


To install the wireless Modem, perform the following steps: 1) Install the SIM card.

Install the subscriber identity module (SIM) card according to the operation guide of the wireless Modem. 2) Disable the PIN check function of the SIM card.

Execute tip to deliver at to the SIM card to disable the personal identity number (PIN) check function of the SIM card. If the PIN in the SIM card is 1234, execute the following two functions:

AT+CPIN=1234 AT+CLCK="SC",0,1234
Execute the first command to submit the PIN to the SIM card for check. Execute the second command to disable the PIN check function of the SIM card. If the SIM card returns error after executing the second command, wait about one minute, and then execute it again.

Note: You can also insert the SIM card into a cell phone, and use the PIN setting in the cell phone to disable the PIN check. The setting interface varies according to the cell phone type. For details, see the instructions delivered with the cell phone.

3)

Connect the serial port cable.

One end of the serial port cable used for installing the Modem is a DB-9 male connector, and is connected to the Modem. The other end is a DB-9 female connector, and is connected to the serial port on the M2000 client.
Huawei Technologies Proprietary 13

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Note: Use a connector if the interface of the serial port cable is different from the serial port on the M2000 client.

4)

Connect the power cable.

Use the DC power cable delivered with the Modem. For details on connecting the power cable, see the specifications delivered with the Modem. 5) Install the Modem driver.

See the specifications delivered with the Modem to install the Modem driver.

5.4.3 Commissioning Wireless Modem


Commission the wireless Modem in the same way as the wired Modem. See 5.3.5Commissioning Client Side Modem to commission the wireless Modem.

5.4.4 Configuring Parameters for Alarm-Notification-by-Short-Messages


Configure the parameters for Alarm-Notification-by-Short-Messages on the client(the PC). To configure the parameters, perform the following steps: 1) Log in to the M2000 client as admin or the user that has the authority to set the remote alarm notification.

Note: After you installing the modem Modem on the client, log into the client as admin or a user account authorized with the authority for setting the alarm notification, and keep this the client running. The alarm notification is deactivated if you shut down the client or log in ton the client as any other user account. Ensure that the parameter RemoteNotifyEventProcessor in the file <M2000 installation directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml is not commented.

2)

Choose Fault > Fault Service Settings. In Remote Notify, enter the user name and the cell phone number, select the alarms to send, and then click Add to add a record of user information for receiving remote alarm notification.
Huawei Technologies Proprietary 14

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

3) 4)

In the User Information field, click Setting. In the displayed Remote notify detail settings, select SMS. Select Activate, and enter parameters such as Serial port. Send point must be Send by client. Click Set.

Note: Ensure to select Current client can be used to send SMS on only one client. Otherwise, the same alarm notification may be sent many times.

5)

In the entry box behind Test NO, enter a cell phone number with the country code; for example, 8613987654321. Click Test to check whether the number is set correctly. If all the settings are correct, the system prompts that the operation is successful, and a short message This is a test is sent to the set cell phone.

6)

Click Close to close Remote notify detail settings.

5.4.5 Checking Alarm-Notification-by-Short-Messages


After installing the Modem, create an alarm manually to check Alarm-Notification-byShort-Messages. To create an alarm manually, perform the following steps: 1) 2) Switch on the cell phone to be set for receiving the short message, and ensure that it works properly. In Remote Notify, select a record of user information, and then set to receive the check alarm. For example, select an alarm with the NE type as OMC, CPUAlarm--1, and click Modify. 3) 4) Choose Tools > System Monitor > Configurations to display System Monitor Configurations. Modify the CPU and memory used rate. For example, set both the CPU and memory used rate to 2. The system generates an alarm when the CPU and memory used rate exceeds this value. Wait until the alarm board prompts the alarm. In normal circumstances, the cell phone receives a SMS after a short while. The period of time from the SMS sending to the receiving depends on the mobile network. The received SMS is in the following format:
+++ MSC id=11 15:42:06 minor restored power system ---

When the test is complete, restore the settings. If error occurs, check and ensure that the Modem works properly, parameters are
Huawei Technologies Proprietary 15

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

configured correctly, and that the service RemoteNotifyService is running on the server.

5.5 Commissioning Alarm-Notification-by-Email


5.5.1 Before Commissioning
Before commissioning the Alarm-Notification-by-e-mail function, ensure that the M2000 system is connected to the SMTP server.

5.5.2 Configuring Parameters for Alarm-Notification-by-Email


To configure the parameters of Alarm-Notification-by-e-mail, perform the following steps: 1) Log in the M2000 client as admin or the user that has the authority to set the remote alarm notification.

Note: If you select Send by client as Send point, ensure that:

You log in to the client as admin or a user account authorized with the The alarm notification is deactivated if you shut down the client or log in to the The parameter RemoteNotifyEventProcessor in the file <M2000 installation is not

authority for setting the alarm notification, and keep the client running.

client as any other user account.

directory>\style\defaultstyle\conf\alarmclient\loadedcell.xml commented.

2)

Choose Fault > Fault Service Settings. In Remote Notify, enter the user name and the email address for receiving the notification alarms, select the alarms to send, and then click Add to add a record of user information.

3) 4)

In the User Information field, click Setting. In the displayed Remote notify detail settings, select Email. Select Activate, and enter parameters such as Hostname or IP of SMTP and Send point. Click Set.

Huawei Technologies Proprietary 16

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Note: If you select Send by client as Send point, ensure to select Current client can be used to send Emails on only one client. Otherwise, the same alarm notification may be sent many times.

5)

In the entry box behind Address of receiver, enter an e-mail address for receiving the notification; for example, abc@def.com.cn. Click Test. An alarm notification e-mail is sent to this e-mail address, with Alarm for test attached indicating that this is a test e-mail.

6)

Click Close to close Remote notify detail settings.

5.5.3 Checking Alarm-Notification-by-Email


To create an alarm manually to check Alarm-Notification-by-e-mail, perform the following steps: 1) 2) Ensure that the SMTP server connected to the M2000 system works properly. In Remote Notify, select a record of user information, and then set to receive the check alarm. For example, select an alarm with the NE type as OMC, CPUAlarm--1, and click Modify. 3) 4) Choose Tools > System Monitor > Configurations to display System Monitor Configurations. Modify the CPU and memory used rate. For example, set both the CPU and memory used rate to 2. The system generates an alarm when the CPU and memory used rate exceeds this value. Wait until the alarm board prompts the alarm. In normal circumstances, the e-mail is sent to the set address after a short while. The period of time from the e-mail sending to the receiving depends on the Internet network. The received e-mail is in the following format:
+++ HuaWei Fault Major Alarm category: Alarm severity: Alarm date: Alarm time: Confirm date: Confirm time: Restore date: Restore time: Product type: Mobile

2004-10-01 12:30:00

Huawei Technologies Proprietary 17

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 5 Commissioning of Remote Alarm Notification Service

Alarm type:

Power system 888 9

Internet serial number: Equipment serial number: NE ID: NE type: Alarm ID: Alarm name: iMAP MSC 2

Alarm name used in the test productid=2 netype=0 alarmid=2 Alarm for test

Attched information: --End

When the test is complete, restore the settings. If error occurs, check and ensure that the SMTP works properly, parameters are configured correctly, and that the service RemoteNotifyService is running on the server.

Huawei Technologies Proprietary 18

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

Chapter 6 Commissioning of Alarm Box


6.1 About This Chapter
This chapter introduces the operations for installing and commissioning the alarm box that are closely related to the M2000 commissioning. For details on the alarm box, see General Alarm Box User Manual.

6.2 Cabling Power Cable and Serial Port Cable


I. Power Cable
Three types of power supply are available for the alarm box: AC 220 V, AC 110 V and DC -48 V. The factory setting is AC 220 V. Choose one of the above power supplies for the alarm box.

II. Fuse
For the AC 110 V power supply, choose the fuse with specifications as F, 2A, H, 250 V; for the AC 220 V power supply, choose the fuse with specifications as F, 1A, H, 250V.

III. Serial Port Cable


Use the RS232 serial port cable delivered with the alarm box. The cable length should not be more than 80 m [314.96 in.]. In case of signal interference, ensure not to cable the serial port and the power cable in parallel in the same tube.

6.3 Installing and Fixing Alarm Box


6.3.1 Introduction to Alarm Box
The M2000 system uses the general alarm box of Huawei, as shown in Figure 1.1. The dimensions of the alarm box are 412 mm x 282 mm x 90 mm [16.22 in. x 11.10 in. x 3.54 in.], with the weight as 2.6 kg [5.733 lb].

Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

Figure 1.1 Appearance of the alarm box On the front of the alarm box, there are mainly the audible and visible alarm information display (such as the four level alarm indicators and speaker) and operation buttons. On the side there are the power supply, interface sockets, etc.. Considering the security of the alarm box, the door of the box is equipped with a lock. Only the personnel with the keys can open the alarm box to perform operations inside the alarm box. All the keys are the same for the convenience of the maintenance personnel. The door of the alarm box is removable for the convenience of installation and maintenance. All the external cables enter the box through the protective cable sheathing at the bottom of the box.

6.3.2 Connecting Alarm Box to M2000


You can connect the alarm box to any of the M2000 clients (PCs) or the terminal of the NE LMT. The former is recommended. As shown in Figure 1.1, connect one end of the RS232 serial port cable to port COM2 (recommended) on the alarm box, and the other end to port COM1 (recommended) on the M2000 client. One end of this serial port cable is an RJ-45 connector, which connects the port COM2 (recommended) on the alarm box. The other end is a DB-9 connector, which connects the port COM1 (recommended) on the PC working as the M2000 client.

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

Figure 1.1 Position of the alarm box in the M2000 system

6.3.3 Fixing Alarm Box


Fix the alarm box on a wall near the M2000 client to which the alarm box is connected.

6.4 Configuring Alarm Box


6.4.1 Setting Power Input
I. AC Power
Adjust the red switch 220 V/110 V power selection rocker switch under the transformer on the alarm box. When the switch shows 230, the alarm box uses the AC 220 V power input; when it shows 115, the alarm box uses the AC 110 V power input.

II. DC Power
When the alarm box uses the DC -48 V power supply, move the connector from JT9 to JT6, as shown by the solid arrow in Figure 1.1. Meanwhile, connect the DC -48 V power cable to JT3 on the power board inside the alarm box, as shown by the hollow arrow in Figure 1.1.

Huawei Technologies Proprietary 3

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

Figure 1.1 Layout of interfaces inside the alarm box

6.4.2 Configuring Serial Port


Connect the M2000 client to the RS232 serial port on the alarm box. The M2000 client uses only one RS232 serial. It is recommended to use COM2 (namely, serial port J5) and to disable other serial ports. Figure 1.1 shows the DIP switch in such a case. The position of S2 and S1 on the board is shown in 6.4.1 IIFigure 1.1.

S2
ON OFF 1 2 3 4 5 6 7 8 ON OFF

S1

3 4

6 7 8

Figure 1.1 Setting the DIP switch of the serial port

6.4.3 Setting Alarm Box Volume


Adjust the potentiometers RP1 and RP2 on the board to set the volume of the alarm box. The position of RP1 and RP2 on the board is shown in 6.4.1 IIFigure 1.1. Adjust RP1 to set the volume of the speaker connected on JT9, and adjust RP2 to set the volume of the speaker connected on JT10 or the remote end sound box.
Huawei Technologies Proprietary 4

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

Set the volume as follows:

To turn up the alarm box

Adjust RP1 or RP2 counter clockwise with a Phillips screwdriver, namely, in the direction from 3 to 1 marked on the potentiometer.

To turn down the alarm box

Adjust RP1 or RP2 clockwise with a Phillips screwdriver, namely, in the direction from 1 to 3 marked on the potentiometer.

6.5 Checking Alarm Box


6.5.1 Checking Alarm Box Power-on
I. Checking Before Power-on
Before switching on the alarm box, ensure that you: 1) 2) You fix the alarm box firmly on the wall. You select the correct external power supply, such as the AC 220 V or AC 110 V power supply, or the DC -48 V power supply, and the fuse capacity for connecting the AC 220 V or AC 110 V power supply. 3) 4) 5) You set the DIP switch of S1 and S2 is correctly. You connect the external serial port cable correctly. The power switch shows Off when you connect the power switch cable to JT6 or JT9.

II. Checking Power-on


See General Alarm Box User Manual to check power-on/power-off of the indicator, reset key and alarm sound.

6.5.2 Commissioning Alarm Box with M2000


Connect the alarm box to the PC at the M2000 client, and then start the M2000 client to perform the following tests: 1) Test the audio and visual alarms generated on the alarm box.

Create alarms of various severities on the alarm box, and check whether it gives corresponding audio/visual alarms. The indicator for an alarm severity remains on as long as there are unrestored and unacknowledged alarms of this severity. 2) Test the control of the M2000 over the alarm box.

The M2000 supports the following three operations on the alarm box:

Stopping the alarm sound: This operation equals to pressing the alarm
Huawei Technologies Proprietary 5

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 6 Commissioning of Alarm Box

acknowledgement button on the alarm box.

Resetting the alarm box: This operation equals to pressing the reset button on the main board of the alarm box. Shutting down the alarm box: After this operation, the M2000 clears all alarm information stored in the alarm box and stops the sound and light. In addition, the M2000 does not send any alarm information to the alarm box. However, the communications connection between the M2000 and the alarm box still exists.

If abnormal results occur, check the serial port connection between the M2000 client and the alarm box.

Huawei Technologies Proprietary 6

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 7 Commissioning of Alarm Plate

Chapter 7 Commissioning of Alarm Plate


7.1 About This Chapter
This chapter introduces the operations for installing and commissioning the alarm plate. These operations are closely related to the M2000 commissioning. For more information, see the manual delivered with the alarm plate.

7.2 Installing Alarm Plate


You can install the alarm plate on the wall of the equipment room, or anywhere far away from the equipment room. Use the serial port cable to connect the COM ports on the alarm plate and the M2000 client. According to various types of COM ports, the serial port cable provides two connectors: DB-9 (with nine pins) and DB-25 (with 25 pins). During the installation, ensure that the cable connector matches the COM port.

7.3 Checking Alarm Plate


Connect the alarm plate to the PC at the M2000 client, and then start the M2000 client to perform the following tests: Create alarms of various severities on the alarm plate, and check whether it gives corresponding audio/visual alarms.

Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Chapter 8 Commissioning of Dial-Up Connection


8.1 About This Chapter
PSTN users can access the M2000 system through the dial-up connection. This chapter describes how to set up and check the dial-up connection.

8.2 Introduction to Dial-Up Connection


The dial-up connection means that the M2000 client accesses the PSTN through the Modem dial-up. The dial-up server also accesses the PSTN through the Modem. The TCP/IP connection is set up between the dial-up server and the M2000 server. This connection assigns an IP address to the remote operation terminal, so that you can start the M2000 client program on the M2000 client to log in to the M2000 system, as shown in Figure 1.1.

Figure 1.1 Dial-up connection

8.3 Commissioning Procedure


Figure 1.1 shows how to commission the dial-up connection.

Huawei Technologies Proprietary 1

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 1.1 Procedure for commissioning the dial-up connection Prepare all the required device cables, configure the dial-up server and client, and then check whether the dial-up connection works. After setting up a dial-up connection successfully, connect the terminal to the PSTN through the Modem and telephone line. Configure this terminal as the dial-up client and ensure that this connection works. In this way, you can set up another dial-up connection.

8.4 Connecting Devices


8.4.1 Before Connection
Before connecting the related devices, prepare devices and information as listed in the following table: Device or information PC 2 Use one PC as the dial-up server and the other as the client. Both PCs use the Windows 2000 Professional operating system. Quantity Use

Huawei Technologies Proprietary 2

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Device or information Modem

Quantity

Use

Connect one Modem to the M2000 client and the other to the dial-up server to have them accessing the PSTN. If the PCs are configured with a built-in Modem, external Modems are unnecessary. See the attached manual of the Modem to install the Modem driver.

PSTN number

These two numbers are telephone numbers corresponding to the dial-up server and client in the PSTN.

8.4.2 Methods for Connecting Devices


As shown in 8.2.1 IFigure 1.1, connect the related devices through the serial port cable, the telephone line, or the network cable.

I. Through Serial Port Cable


When using an external Modem, use the serial port to: 1) 2) Connect the Modem and the dial-up server. Connect the Modem and the M2000 client.

II. Through Telephone Line


Use the telephone line to: 1) 2) Connect the Modem on the dial-up server to the PSTN. Connect the Modem on the client to the PSTN.

III. Through Network Cable


Use the network cable to connect the dial-up server to the LAN switch in the M2000 system.

8.5 Configuring Dial-Up Server


8.5.1 Setting IP Address
Assign an IP address to the dial-up server. Ensure that the IP address is in the same network segment as that of the M2000 server.

Huawei Technologies Proprietary 3

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

In the Windows operating system, set the IP address as follows: 1) 2) 3) 4) 5) Choose Start >Settings > Control Panel. Double-click Network and Dial-up Connections. Right-click Local Area Connection, and select Properties to display Local Area Connection Properties. Select Internet Protocol (TCP/IP) and click Properties to display Internet Protocol (TCP/IP) Properties. Select Use the following IP address to display a dialog box as shown in Figure 5.1, and set IP address, Subnet mask and Default gateway. Ensure that the set IP is in the same network segment as the IP of the M2000 server, and then click OK.

Figure 5.1 Setting the IP address of the dial-up server

8.5.2 Configuring Network Connection


Configure network connection for the dial-up server as follows: 1) Choose Start > Settings > Network and Dial-up Connections/Make New Connection to display a dialog box as shown in Figure 1.1.

Huawei Technologies Proprietary 4

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 1.1 New Connection Wizard

Note: If you configure the network and dial-up connections for the first time, the screen displays the dialog box about location information. Click Cancel.

2)

Click Next, and the system displays a dialog box as shown in Figure 2.1.

Huawei Technologies Proprietary 5

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 2.1 Network Connection Type 3) Select Accept Incoming Connections and click Next, and the system displays a dialog box as shown in Figure 3.1.

Figure 3.1 Selecting a connection device 4) Select Modem, and then click Next to display a dialog box as shown in Figure
Huawei Technologies Proprietary 6

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

4.1.

Figure 4.1 Incoming Virtual Private Network (VPN) Connection 5) 6) Select Do not allow virtual private connections, and then click Next to display a dialog box as shown in Figure 6.1. Select an existing user or the user with a new dial-up connection.

Figure 6.1 User permissions

Huawei Technologies Proprietary 7

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

To select an existing user

Select a user from the user list, and then click Next to display a dialog box as shown in Figure 6.3.

To add a user

Click Add to display a dialog box as shown in Figure 6.2. Set the user properties, and then click OK to display a dialog box as shown in Figure 6.3.

Figure 6.2 New User

Figure 6.3 Network software 7) Select all components in the list, and then click Next to display a dialog box as shown in Figure 7.1.

Huawei Technologies Proprietary 8

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 7.1 New connection wizard complete 8) Enter a name for the connection, and then click Finish to complete configuring the dial-up server.

8.5.3 Specifying IP Range of Dial-Up Client


Specify the IP address range of the dial-up client as follows: 1) 2) 3) 4) 5) 6) Choose Start > Settings > Control Panel. Double-click Network and Dial-up Connections. Right-click Incoming Connections, and select Properties to display Incoming Connections Properties. Select Networking to display the network setting window. Select Internet Protocol (TCP/IP) and click Properties to display Incoming TCP/IP Properties. Select Specify TCP/IP addresses in TCP/IP address assignment and enter the IP address range allowed to be allocated automatically to the dial-up client, as shown in Figure 6.1. Click OK. Note:

Normal routes must be available for the dial-up client to access the M2000 server. The IP addresses of the dial-up client must not conflict with the intra-network IP address.

Huawei Technologies Proprietary 9

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 6.1 Setting IP address range for the dial-up client

8.6 Configuring Dial-up Client


8.6.1 Configuring IP Address
When you activate a dial-up connection, the dial-up server assigns an IP address to the dial-up client automatically. Therefore, you should set Obtain an IP address automatically on the dial-up client. In the Windows operating system, set Obtain an IP address automatically as follows: 1) 2) 3) 4) 5) Choose Start >Settings >Control Panel. Double-click Network and Dial-up Connections. Right-click Local Area Connection, and select Properties to display Local Area Connection Properties. Select Internet Protocol (TCP/IP) and click Properties to display Internet Protocol (TCP/IP) Properties. Select Obtain an IP address automatically, as shown in Figure 5.1. Click OK.

Huawei Technologies Proprietary 10

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 5.1 Setting the IP address of the dial-up server

8.6.2 Configuring Network Connection


Configure the dial-up client as follows: 1) 2) Choose Start > Settings > Network and Dial-up Connections >Make New Connection to display New Connection Wizard, as shown in 8.5.2 IFigure 1.1. Click Next, and the system displays a dialog box as shown in Figure 2.1.

Huawei Technologies Proprietary 11

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

Figure 2.1 Network Connection Type 3) Select Dial-up to private network, and then click Next to display a dialog box as shown in Figure 3.1.

Figure 3.1 Phone Number to Dial 4) Enter the telephone number to dial, namely, the number the dial-up server is
Huawei Technologies Proprietary 12

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

connected to, and then click Next to display a dialog box as shown in Figure 4.1.

Figure 4.1 Connection Availability 5) Select Only for myself, and then click Next to display a dialog box as shown in Figure 5.1.

Figure 5.1 New Connection Wizard complete

Huawei Technologies Proprietary 13

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

6)

Enter a name for the connection, and then click Finish to complete configuring the dial-up client.

8.7 Checking Dial-up Connection


Activate the configured dial-up connection, and check it as follows: 1) On the client, choose Start > Settings > Network and Dial-up Connections, and double-click the configured connection to display a dialog box as shown in Figure 1.1.

Figure 1.1 Setting dial-up connection properties 2) Enter the username and password for the dial-up connection. Use the username and password set on the dial-up server. For details, see 8.5.26 Select an existing user or the user with a new dial-up connection.. 3) 4) Enter the phone number to dial, namely, the number the dial-up server is connected to. Click Dial to activate the network connection. If the connection is activated successfully, the commissioning of the dial-up server is complete. In this case, an icon is displayed in the status area in the toolbar to indicate the connection status. Otherwise, check the settings made on the dial-up server and client, especially the IP address of the dial-up server, the user information and the telephone number.

Huawei Technologies Proprietary 14

Commissioning Guide iManager M2000 Mobile Element Management System

Chapter 8 Commissioning of Dial-Up Connection

If the connection has still failed, the problem may be that the dial-in function of the Modem is not activated. See 8.8Activating Modem Dial-in to activate the dial-in function, and then check the connection again as described earlier in this document. 5) On the dial-up client, execute the M2000 client application. Enter the user name, the corresponding password and the IP address of the M2000 server to log in to the M2000 server. If you log in successfully, the client is connected to the M2000 server, and the topology is displayed on the client. If you fail to log in, check if the server is working well.

8.8 Activating Modem Dial-in


The dial-in function of the Modem is activated by default when delivered from the factory. However, some manufacturers do not to activate this function in consideration of security. In this case, the dial-up connection does not work. After installing the Modem and checking all the system settings, activate the dial-in function as follows: 1) Choose Start > Programs > Accessories > Communications > HyperTerminal on the dial-up server. Enter a name for the connection, and set the properties. 2) Execute the following command on HyperTerminal to activate the dial-in function of the Modem: aat The system prompts OK. 3) Execute the following command to set the ring back tone.

ats0=X X indicates dialing in after how many ring back tones are heard. For example, ats0=5 means to dial in after five ring back tones are heard. The system prompts OK. 4) Execute the following command to save the settings.

at&w0 The system prompts OK, and the setting is complete.

Huawei Technologies Proprietary 15