Академический Документы
Профессиональный Документы
Культура Документы
1- Connect DUS Splitter to LMT port in the DUS 2- Connect a serial to USB cable from Port LMT A at the splitter to client usb port. 3- Open a hyper terminal (Eg: TerraTerm) 4-Put the DUS in backup mode: $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set 5-Format both drive D and C2 $ formathd /d All data on volume will be destroyed. Continue? y/n (n):y Formatting Hard Disk... $ $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1
Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set $ formathd /c2 All data on volume will be destroyed. Continue? y/n (n):y Formatting Hard Disk... $ $ reload -OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes Stop due to remain in basic/backup set 6- Set IP $ ifconfig le0 169.254.1.10 netmask 255.255.0.0 $ ifconfig le0: inet 169.254.1.10 netmask 255.255.0.0 broadcast 169.254.255.255 $ ----------------------------------------------------------------------------------------------------------Connect Ethernet cable to Port LMT B at the splitter to Ethernet Port at client Turn of anti-virus/Symantec Change laptop IP to the following:
7- FTP Basic Package Connect to DUS using FTP and transfer directory /c2 and /d of the basic package CXP9021502%16_R21CK to directory /c2 and /d of the DUS. Do ensure your transfer mode set to Binary
8- Activate Basic Package $ reload OSE Delta PowerPC/BL410393 Welcome to OSE Shell ose5.5. Start of @(#)CXC1731599 R2A13 2012-02-17 09:46:41 GMT $ Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: Fallback (own)
Copying new boot image to flash.. Image copied su OSE Delta PowerPC/BL410512 username: Start of @(#)CXC1731602 R79X10 2012-06-18 07:54:20 GMT Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: NormalActive (own), Undefined (peer), peer supa=0xffffffff Component rtrdb (V08.05.0000 (PATCH-A)/OSE-powerpc EMBEDDED) Copyright (C) 1994-2012 by Enea Software AB Constructing Database rtrdb RTRDB: Default persistence is transient Loading '/gzip//d/configuration/cv/basic_cv/db.dat' Ready All programs loaded and started All configured PIUs started on node Login Server Ready --------------activate basic package done. Reconnect to DUS using hyperterminal-----username: rbs password: Welcome to OSE Shell ose5.5. $ $ $ cv ls Please wait for list.... Name: basic_cv Date: Sat Aug 25 22:29:19 2012 Id: no value (cv product id) Type: other Package upgrade: CXP102051/16_R21CK Operator: no value (operators name) Comment: no value (operators comments) Status: ok
Number of CVs = 1 (Max 50) $ $ vols volume total used free frw device unit / 0K 0K 100% 0K 100% FR/null 0K 0K 100% 0K 100% FRW /gzip 1K 1K 100% 0K 0% -RW none /mole 1K 1K 100% 0K 0% -RW none /erpdout 1K 1K 100% 0K 0% -RW none /ffs 1K 1K 100% 0K 0% -RW none /rmd 1014K 22K 2% 992K 98% FRW ram_disk 0 <4-2031> /h 1014K 14K 1% 1000K 99% FRW ram_disk 1 <4-2031> /d 976M 123M 13% 852M 87% FRW usbdd 0 <4-1999999> /zip 1K 1K 100% 0K 0% -RW none /c 5859M 257M 4% 5602M 96% FRW usbdd 0 <2000000-13999999> /j 5859M 257M 4% 5602M 96% FRW /c 0 <2000000-13999999> $ 9- Upgrade Package Ftp L12B ICP4 CXP102051%16_R25AK Upgrade package folder to directory /c/tmp in DUS
10- Once upgrade package transferred, connect to hyperterminal and reload $ reload OSE Delta PowerPC/BL410512 username: Start of @(#)CXC1731602 R79X10 2012-06-18 07:54:20 GMT
Plug-in Unit Product Name: DUS4101 Plug-in Unit Product No: KDU137624/1 Plug-in Unit Product rev: R3C Plug-in Unit Product Date: 20120903 Plug-in Unit Product Serial: C826325559 Ethernet MAC_address 0: 0x9055AE526F8D RAM size: 2048 Mbytes BoardMgr: Starting Configuration Version: basic_cv CM State: NormalActive (own), Undefined (peer), peer supa=0xffffffff All programs loaded and started Component rtrdb (V08.05.0000 (PATCH-A)/OSE-powerpc EMBEDDED) Copyright (C) 1994-2012 by Enea Software AB Constructing Database rtrdb RTRDB: Default persistence is transient Loading '/gzip//d/configuration/cv/basic_cv/db.dat' Ready All configured PIUs started on node Login Server Ready
Click on Create UP button and fill up the following and click create package button.
Create CV
Upgrade SW done.