Вы находитесь на странице: 1из 2

D1 D1 D2 D2 p1 p1 p1 - p2 p1 - p2 p2 ni mi rho kappa

Orifice calculation sheet Service fluid Input Values Line ID Line ID


Bore Diameter Bore Diameter Upstream pressure upstream pressure pressure drop through orifice pressure drop through orifice downstream pressure kinematic viscosity dynamic viscosity upstream density isentropic coefficient Intermediate value

Oxygen Units 154.1 mm 0.1541 m 91.422 mm 0.091422 m 17.5 kg/cm2 g 1817580.345 pa 2500.000 mm WC 24516.625 Pa 1793063.72 pa 1.98456E-06 m2/s 0.000018 Pas 9.07 kg/m3 1.32

Note 1 Note 2

Based on the calculation met http://www.flowmeterdirecto

Corner taps are assumed. Valid for gases, steam, and va

V1 V2 ReD e C beta E Q G G

upstream velocity throat velocity upstream Reynolds number expansion coefficient coefficient of discharge diameter relation D2/D1 Area constant Final Values volumetric flow rate mass flow rate mass flow rate

16.65181619 m/s 47.3113619 m/s 1293001.501 0.995367306 0.605093944 0.593264114 1.068359891 0.310568044 m3/s 2.81685216 kg/s 10140.66778 kg/hr

Values need to provided by user in highlighted cells Iterative calculations should be enabled in Excel Based on the calculation method at: http://www.flowmeterdirectory.com/flowmeter_orifice_calc.html Corner taps are assumed. Valid for gases, steam, and vapors