Вы находитесь на странице: 1из 1

THE REQUIREMENTS OF THIS ZONING PLAN SHALL HAVE TO BE FULFILLED IN ADDITION TO THE BUILDING REQUIREMENTS CONTAINED IN THE PUNJAB

URBAN PLANNING & DEVELOPMENT AUTHORITY (BUILDING) RULES, 1996 & AMENDMENT MADE FROM TIME TO TIME.

ZONING CLAUSES
100'-0" 2540'-0" 100'-0"

1) USE ZONES:-

THE USE OF LAND AND THE TYPE OF BUILDING TO BE CONSTRUCTED THERE ON SHALL BE GOVERNED IN ACCORDANCE WITH THE TABLE BELOW AND IN NO OTHER MANNER WHAT- SO- EVER PERMISSIBLE USE OF LAND ROADS TYPE OF USES PERMISSIBLE ROADS/STREET FURNITURE AND AMENITITES SUB SERVIENT TO TRAFFIC AND TRANSPORTATION.

8 0' - 0"

N I P E R
W I D E
MILLANIUM SCHOOL AREA:- 5.34 ACRS

NOTATION

OPEN SPACES

LANDSCAPING FEATURES, PAVEMENTS, AMENITIES AND FACILITIES AND ANY ACTIVITY SUB- SERVIENT TO RECREATION.

PUBLIC OTHER

RESIDENTIAL USES AND BUILDINGS SUB-SERVIENT TO GROUP HOUSING / RESIDENTIAL USE AS PER SEPARATE LAYOUT PLAN/ M.S FLATS ZONING PLAN.

O
GLOBLE INSTITUTE

A
SITE FOR NURSING HOME

D
RESERVED USE AS DETERMINED BY REGIONAL PLANNING AND DESIGN COMMITTEE OF PUDA.

10'-6" 10'-6" 39'-0" 39'-0"

1100

1101

1105

1106

1107

1108

1111

1112

GG

GG

1099 1098

1084 1085

1076 1075

1119 1120

G G R-5'

G G R-5'

R-5' G G

GG

GG

G R-5'

R-5' G G

10'-6" 10'-6" 39'-0" 39'-0"

3 0' - 0"
R-5 '

D
R-5'

WATER WORKS AREA:- 1.95 ACRS


G G R-5' G G 1163 1162 1164 1165

RESIDENTIAL

RESIDENTIAL BUILDING,ANCILLARY BUILDING INCLUDING GARAGES, SERVANT QUARTERS ETC. AND AMENITIES SUB SERVIENT TO RESIDENTIAL USE. COMMERCIAL AND CORPORATE OFFICES & USES SUB SERVIENT TO THEM, AS PER SEPARATE LAYOUT PLANS / ZONING PLANS.

GG

10'-6"

10'-6"

T.W

GG

1200'-3"

GG

GG

GG

A D

GG

10'-6"

GG

39'-0" 10'-6" 10'-6"

10'-6"
R-5' G G

10'-6"

39'-0" 10'-6"

A D

39'-0"

39'-0"

GG

INFORMATION TECHNOLOGY PARK (611'-6"X1120'-3") AREA:- 15.726 ACRS

1083

1082

1078

1077

1118

1117

1114

(8M)

GG

GG

R-5'G G

10'-6"

(8M)

GG

GG

G R-5'

R-5'G G

GG

G G R-5'

1113

GG

GG

GG

GG

GG

(8M)

(8M)

COMMERCIAL

10'-6"

10'-6"

INSTITUTIONAL

INSTITUTIONS AND USES SUBSERVIENT TO THEM AS PER SEPARATE LAYOUT PLANS / ZONING PLAN.

R-5 G G '

GG

GG

1093 1092

1090 1091

R O

1070 1069

1125 1126

R O

R O

2) SITE COVERAGE AND FLOOR AREA RATIO:SITE COVERAGE SHALL BE AS PER PUDA (BUILDING) RULES 1996 AND AS AMANDED FROM TIME TO TIME. THE MAXIMUM PERMISSIBLE COVERAGE ON GROUND IN RESIDENTIAL PLOTS SHALL BE AS UNDER:FOR THE FIRST 210 SQ M - 65% FOR THE NEXT 210 SQ.M - 50% FOR THE REMAINING AREA - 40% THE MAXIMUM FLOOR AREA RATIO IN CASE OF RESIDENTIAL PLOTTED DEVELOPMENT SHALL NOT EXCEED: FOR PLOTS UPTO 225 SQ.MTS -1.65 FOR PLOTS ABOVE 225 SQ.METERS BUT NOT EXCEEDING 325 SQ.MTS - 1.40

R-5'

GG

10'-6" 10'-6" 39'-0" 39'-0"

1063

1064

1067

1068

1135

1136

1139

1140

GG

GG

10'-6"

10'-6"

GG

GG

(8M)
1058 1057

(8M)
1142 1141

I D

A D

GG

GG

R-5'G G

10'-6"

(8M)

GG

G G R-5'

R-5'G G

GG

G G R-5'

I D

1062

1061

1146

1145

GG

GG

GG

GG

1014

1017

1055

1128

GG

1015

1016

1056

1127

G G R-5'

G R-5'

R-5' G G

GG

G G R-5'

R-5' G G

10'-6" 10'-6" 39'-0" 39'-0"

GG

G G R-5'

(8M)

3 6' - 0"
R-5 '

O
R-5'

GG

R-5 '

RESERVED

GG

GG

GG

3 0' - 0"

GG

GG

3 0' - 0"

GG

GG

GG

GG

1050 1049

1133 1134

1148 1147

1179 1180

3 0' - 0"

10'-6"

39'-0" 10'-6"

39'-0" 10'-6"

39'-0"

10'-6"

39'-0" 10'-6" 10'-6"

GG

10'-6"

10'-6"

i ii

3) BUILDING LINE

D E

(10M)

6 0' - 0"

3 0' - 0"
60'-0" 13'-9"

W
GG

E
G G R-5'

O
GG

D
60'-0" 13'-9"

C O M M E R C I A L / C O R P O R A T E O F F I C E S A R E A :- 13.81ACRS

GG

GG

NO BUILDING SHALL BE ALLOWED TO PROJECT BEYOND THE FRONT,REAR AND SIDE BUILDING LINES SHOWN THUS ON THE ZONING PLAN
BUILDING LINE

GG

GG

G 1048 1047

GG

GG
9'-0"

GG
9'-0"

GG

GG

GG

GG 1182

G 1181

4) PROJECTION
WHERE THERE IS AN UNCOVERED BALCONY OR CHAJJA OR CANTILEVER FROM WALL, IT SHALL NOT PROJECT MORE THAN TWO METERS BEYOND THE BUILDING LINE WHEN MEASURED AT RIGHT ANGLES TO THE OUTER FACE OF THE WALL AND IT SHALL BE WITHIN THE BOUNDARIES OF THE SITE AND IN CASE OF ROW HOUSES OR BUILDING ADJOINING EACH OTHER THE PROJECTION SHALL NOT BE MORE THAN ONE METRE IN CASE THE AREA OF SITE IS LESS THAN 250 SQ.MTS. PROVIDED THAT PROJECTION ON DOORS AND WINDOW SHALL NOT EXCEED 0.45 METRES (1'-6"). NO PROJECTION SHALL BE AT A LESSOR HEIGHT THAN 2.25M (7'-4 PLINTH LEVEL OF BUILDING.
1 2")

1041

1040

1193

3 0' - 0"

3 6' - 0"

1192

13'-9"

48'-9" 14'-0"

(14M)
1038 1039

13'-9" 13'-9"

GG

GG

13'-9"

14'-0" 48'-9"

(14M)
1205 1206

12'-3"

12'-3"

60'-0"

68

GG

GG

1002 1001

1029 1030

22'-0"

60'-0"

1031

1032

1194

1195

22'-0"

GG

GG

GG

GG

R-

5'

' R-5 G G

V A L L E Y

13'-9"

13'-9"

GG

GG

GG

GG

GG

CLEAR ABOVE THE

S E C T O R - 66

8 0' - 0" E

S E C T O R

THE WIDTH OF PROJECTION SHALL NOT EXCEED 1 4TH OF THE WIDTH OF THE SITES. THE AREA OF THE PROJECTION SHALL NOT BE COUNTED TOWARDS THE COVERED AREA OF THE SITE. NO PROJECTION SHALL BE ALLOWED OVER GOVT. LAND IN CASE OF CORNER PLOTS. SIDE PROJECTION WITH IN SET BACK SHALL NOT BE MORE THAN 1'-6" IN CASE OF 14 MARLA PLOTS.

80'-0"

2058'-6"

COMMERCIAL AREA:- 4.71 ACRS

L E I S U R E

5) HEIGHT:-

USE ZONES

10'-6" 10'-6" 39'-0" 39'-0"

GG 2713 2712

GG

GG

GG

GG

GG

GG

GG 2698

G R-5' 2697

R-5'

R-5'

10'-6"

GG

2680

2681

2695

2696

GG

(8M)

2669

2602

2670

2601

AIR FORCE NAVAL HOUSING AREA:- 9.70 ACRS

4 0' - 0"

PERMISSIBLE HEIGHT FROM PLINTH TO TOP OF PARAPET / BARASATI a) MAXIMUM HEIGHT 32'-3"

b) MAXIMUM HEIGHT 24'-9"

10'-6"

GG

1 0 0' - 0"

R O A D

GG

GG

GG

GG
R-

GG

GG

GG
10'-6" 10'-6" 39'-0" 39'-0"

GG GG

GG GG 2672

GR-5' G R-5' 2671

COMMERCIAL / CORPORATE AREA:- 3.57 ACRS

2 8' - 6"
2679 2678
5'
R-

W I D E
GG

R O A D

R-

GG

10'-6"

GG

2726 2725

2727 2728

5'

GG

1 0 0' - 0"

THE CLEAR HEIGHT FROM FLOOR TO CEILING IN CASE OF GARAGE,STORE,TOILET,BARASATI AND MUMTY SHALL NOT BE LESS THAN 2.30 M (7'-6")

5'

GG

O A

W I D E

2649

2650

2656

2657

(8M)

GG

(8M)
GG

6)

PLINTH LEVEL:PLINTH LEVEL WILL BE OBTAINED FROM CONCERNED D.E.(PUBLIC HEALTH) PUDA. UNLESS OTHERWISE SPECIFIED BY THE DIVISIONAL ENGINEER(PUBLIC HEALTH)PUDA. PLINTH HEIGHT IN CASE OF BUILDING INTENDED FOR HUMAN HABITATION SHALL BE 0.45MTR(1'-6") ABOVE THE FINISHED LEVEL OF THE ROAD/STREET.

10'-6"

1045'-9"

R O A D

GG
10'-6" 10'-6" 39'-0" 39'-0" 10'-6"

GG GG 2641

GG G 2640

GG

G R-5'

GG

GG

R-

2 8' - 6"

W I D E

R O A D
R5 '

GG

GG

2648

2647

3 0' - 0"

39'-0" 14'-0"

GG

GG

10'-6"

48'-9"

12'-3"

R-5' G G

GG

GG

10'-6"

GG

5'

(8M)

GG

W I D E

GG

(8M)
2638 2639

2659 2658

2612 2613
R-

7)

SIDE ENTRY GATE IN CORNER PLOTS :NO SIDE ENTRY IN THE MAIN BUILDING SHALL BE ALLOWED NO SIDE /BACK GATES WILL BE ALLOWED IN CASE OF THE PLOTS FALLING ON 60', 80' AND 100' WIDE ROADS & WHERE THE PUBLIC OPEN SPACES SEPARATING THE PLOTS AND THE ROAD RESERVATION EXCEED 30'-0", ONE SIDE GATE NOT EXCEEDING 3'-6" IN WIDTH IN BACK COURTYARD IS ALLOWED IN CASE OF CORNER PLOTS SITUATED ON OTHER ROADS.

2631

GG

W I

GG

2632

10'-6"

R-5'G G

GG
10'-6"

GG GG

GG

R-

5'

R-5'

5'

2 8' - 9"

W I D E
GG GG

R O A D
GG GG GG GG 2615 2614

GG

GG

3 0' - 0"

10'-6" 39'-0"

G 2630

GG
10'-6" 39'-0" 39'-0"

4 0' - 0"

10'-6"

10'-6"

39'-0" 10'-6" 10'-6"

2629

GG

GG

2715 2714

2738 2739

(8M)
2755 2756

DANGA PIRAT HOUSING SOCIETY AREA:- 4.20 ACRS

2740

2741

8)

BOUNDARY WALL AND GATES:THE BOUNDARY WALLS OF RESIDENTIAL END PLOTS ABUTTING THE ROADS SHALL BE ROUNDED AT THE CORNERS BY RADIUS OF( 5'-0")IN CASE OF OTHER SITES, IT SHALL BE AS SHOWN ON THE PLAN. THE HEIGHT OF THE FRONT AND SIDE BOUNDARY WALL IN RESIDENTIAL PLOTS SHALL BE 2'-101 2" AND THAT OF THE REAR OPEN COURTYARD BOUNDARY WALL SHALL BE 6'-0". THE GATE AND THEIR POSITION SHALL BE AS SHOWN 'G' ON THE PLAN. THE GATE POSTS SHALL PROVIDE FOR DISPLAY OF POSTAL NOS.

4 0' - 0"

8 0' - 0"

GG

10'-6"

GG

GG

GG

GG

GG

GG

GG

4 0' - 0"

RESERVED A:- 0.584 ACRS COMMERCIAL / CORPORATE AREA:- 2.48 ACRS


9)

COMMERCIAL / CORPORATE OFFICES AREA:- 4.36 ACRS

TREES:NO TREE SHALL BE CUT WITHOUT THE PRIOR APPROVAL PUDA, AND EXISTING TREE SHOWN THUS ON PLAN SHALL BE DEEMED TO BE PROTECTED TREES.

30'-0"

30'-0"

30'-0"

30'-0"

10)

BASEMENT:BASEMENT IS PERMISSIBLE IN ALL CATEGORIES OF PLOTS. IF THE ADJOINING BUILDING IS ALREADY CONSTRUCTED WITHOUT BASEMENT, THEN THE BASEMENT SHALL BE RECESSED AND THE MINIMUM DISTANCE FROM THE COMMON WALL OF THE ADJOINING CONSTRUCTED BUILDING UPTO THE WALL OF BASEMENT SHALL NOT BE LESS THAN 8'-0". THE BASEMENT SHALL PROVIDE FOR OPENING OF NOT LESS THAN 1/10TH OF THE BASEMENT FLOOR AREA OPENING DIRECTLY TO THE EXTERIOR FOR ADMISSION OF NATURAL LIGHT AND AIR AND SHALL BE WATER PROOF AND DAMP PROOF THE MINIMUM HEIGHT OF THE BASEMENT SHALL BE 8'-3" MEASURED FROM THE FINISHED LEVEL OF THE FLOOR TO THE UNDER SURFACE OF THE BEAM AND SHALL NOT BE USED FOR HABITABLE PURPOSES. BASEMENT AREA SHALL NOT EXCEED THE AREA ON THE GROUND FLOOR OF THE BUILDING AND SHALL LIE BELOW IT AND FURTHER IT SHALL SATISFY PUBLIC HEALTH AND STRUCTURAL REQUIREMENTS. PROVISION OF TOILETS, WATER TAPS ETC. WHICH REQUIRE THE DISPOSAL OF WATER ETC. SHALL NOT BE PERMITTED IN THE BASEMENY.

2 0 0' - 0"

E C T O R - 80
NOTES:THE ZOING PLAN IS BASED ON THE LAY-OUT-CUM NUMBERING PLAN DRG. NO. 05, JOB NO. M-67 IN CASE OF 8 MARLA PLOTS THE GROUND FLOOR OF THE BUILDING SHALL BE SO DESIGNED AS TO PROVIDE A MINIMUM CLEAR DEPTH OF 12'-0" FROM THE FRONT BOUNDARY WALL FOR PARKING OF VEHICLE WITHIN THE PLOT.

NOTES:THE DIGITIZED DRAWING IS BASED ON THE ORIGINAL DRAWING OF THE CONCERNED DEPARTMENT.IN CASE OF ANY DISCREPANCY THE DETAILS IN THE ORIGINAL DRAWING SHALL PREVAIL UPON.

13'-9"

10'-6"

14'-0"

Sd

CHIEF ADMINISTRATOR
60'-0" 87'-6"

Sd

Sd

39'-0"

60'-0"

48'-9"

75'-0"

22'-0"

21'-0"

26'-3"

22'-0"

SENIOR TOWN PLANNER


13'-9"

ARCHITECT
DATED 20-11-2002 JOB NO. MISC-67 DRG NO. 03 N

10'-6"

9'-0" 12'-3"

9'-0"

SCALE:- 1"=100'-0" DEALT BY: LALITA GABA CHECKED BY: SURJIT SINGH

30'-9"

30'-0" 30'-9" 30'-0"

36'-9"

36'-0"

36'-0"

8 MARLA PLOTS

10 MARLA PLOTS

14 MARLA PLOTS

ZONING PLAN OF SECTOR-67 S.A.S. NAGAR

Вам также может понравиться