Академический Документы
Профессиональный Документы
Культура Документы
PMEG3005EB
D1
U1
C
SC4525C
8 BST
C1
C
0.33uF L1
Vin
2
12V C11* NP C12* NP C4 4.7uF/25V
Vout1
Vout1
IN
SW
1
3.3uH
1.5V/3A
SS/EN
FB
7
R4
GND
COMP 6
R9 10k C7 R11 Enable Control 100k Q1 BC848A 22nF C8 47pF C5 3.9nF R7 5.23k R5 38.3k R6 66.5k D2 PMEG4030ER
ROSC 3
GND 4
EP 9
33.2k C2 47uF/10V
GND. Enable Control: 1. Connect directly to SS/EN pin if 'Enable Control' signal is Open-collector or Open-drain output; 2. Or use 1 NPN small signal transister for EN control with inverting logic; 3. or use 2 NPN transisters for non-inverting logic, as shown in below.
R8 0R
D4
U2 Vin_
Vin 12V C11*1 NP C12*1 NP C10 4.7uF/25V
SC4525C
8 BST
C3 0.33uF
PMEG3005EB
L2
Vout2
IN
SW
1
6.8uH 3.3V/3A
SS/EN
FB
7
R14
GND...
Vin R16 R17 100k 10k C12 1uF R18 Vout1 100k Q3 BC848A Q2 BC848A C9 22nF 47pF C11 3.9nF R13 12.1k R12 38.3k R15 14.3k D3 PMEG4030ER
COMP 6
ROSC 3
GND 4
EP 9
33.2k C6 47uF/10V
C13
Sequencing control (or Enable control with non-inverting logic): 1. C13 could be adjusted to get the desired sequencing (or enable) delay time. 2. Vout1 must be higher than 0.7V to turn on Q3 properly.
A
GND..
R19 0R
A
Title
Vo2=3.3V, Fsw=500kHz
Sheet
1
Rev B
of