GENERAL NOTES

FOR C.S. L65 x 65 x 10mm FOR S.S. L65 x 65 x 6mm


C

FOR C.S. L75 x 75 x 12mm FOR S.S. L75 x 75 x 8mm

1. DEMISTER THICKNESS AS SHOWN ON VESSEL OR COLUMN DRAWING. 2. DEMISTER FRAMED WITH TOP AND BOTTOM GRID OF 25mm HIGH. (TO BE SUPPLIED DEMISTER VENDOR). 3. C.S.=CARBON STEEL S.S.=STAINLESS STEEL

D A D C
12 x 75mm WIDE RING

4. TIE WIRE TO BE STAINLESS STEEL. IF WIRE DIAMETER IS BELOW 3.2mm (NO.10 USS GAGE WIRE AT TIE IS TO BE DOUBLE STRANDED.

5. ADJACENT DEMISTER PAD SECTIONS TO BE FASTENED ALONG TOP AND BOTTOM GRID BARS. DIRECTION OF DEMISTER SECTIONS. 6. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. 7. EQUIVALENT OR LARGER METRIC ANGLES MAY BE SUBSTITUTED.

C
12 x 75mm WIDE RING

SEE TYPE DETAIL OF BEAM SUPPORT DEMISTER THICKNESS SEE NOTE 1

REFERENCE DRAWINGS

DEMISTER THICKNESS SEE NOTE 1

ELEV. ON COL. DWG.

SECTION A-A
DEMISTER SUPPORT FOR DIAS FROM 600mm THRU 2400mm CUT FLANGE OF ANGLE TO SUIT RING

SECTION B-B
DEMISTER SUPPORT FOR DIAS. FROM 2400mm THRU 4800mm

FORMERLY STD. DWG. AD-036657; SHT. 001; REV. 04

ANGLE IRON TO BE INCLUDED IN TIE WHERE POSSIBLE TIE WIRE

REV. NO.

DATE

BY

DESCRIPTION

CHKD CERT.

APPD

DRAWN BY

CHECKED BY

EQ. SUPPORT BEAM SLOTTED TIE WIRE

EQ.
DATE STARTED DATE COMPLETED

DISTANCE BETWEEN TIES TO BE A MINIMUM OF 150mm AND A MAXIMUM OF 300mm

OPRG DEPT.

ENG DEPT.
CERTIFIED DATE

THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION OR FOR ORDERING MATERIAL UNTIL CERTIFIED AND DATED

SECTION C-C
TYPICAL FASTENING DETAIL

TYPICAL DETAIL OF BEAM SUPPORT

SEE NOTE 1

SEE NOTE 5

DEMISTER SUPPORTS FOR COLUMNS AND VESSELS


LIBRARY DRAWING
PLANT NO. INDEX DRAWING NUMBER

SAUDI ARABIA
SHEET NO. REV. NO.

SECTION D-D

M88

C/D DD-950004 001

00
CADD

A 2636 ENG.(5.85)