NQI Improvement Plan

KEY PERFORMANCE INDICATORS


NETWORK ACCESSBILITY 1.SDCCH BLOCKING

2.SDCCH DROP
3.TCH BLOCKING 4.TCH ASSIGNMENT SUCCESS RATE

NETWORK RETAINBILITY 1.TCH DROP 2.HANDOVER SUCCESS RATE

2 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

Call Establishment

Get Service

Get SDCCH

Establish SD Channel

Est. TCH Conn.

Call Phone

Ref. Phone

SD Blocking SDCCH Seizer

TCH Blocking

CSSR or TCH Assignment

Call completion Rate (TCH Drop call)

3 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

SDCCH BLOCKING
REASONS:1.HIGH UTILIZATION TRAFFIC TREND 2.LESS NO. OF SDCCH DEFINED IN THE CELL 3.EXCESSIVE LAC UPDATIONS 4.CHECK BANDWIDTH OF LAPD (i.e.16kbps,32kbps,64kbps) 5.HARDWARE ISSUES 6.HIGH QUEING TIMER VALUES SOLUTIONS:1.CAPACITY ADDITION 2.MORE SDCCH DEFINITIONS OR USE DYNAMIC SD (LAPD LINK SHOULD BE 32KBPS) 3.REHOMINGS FOR UNEVEN LAC BOUNDRIES AND CRH,C2 VALUE RETUNING 4.LAPD AUGMENTATION (i.e. 16 to 32kbps etc.) 5.CLEARANCE OF HARDWARE ALARMS 6.OPTIMIZE THE QUEING VALUES

4 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

TCH BLOCKING
REASON:1.HIGH TRAFFIC TREND 2.NON-SYMMETRICAL NEIGHBOR RELATIONS 3.ONLY FULL RATE ENABLED IN THE CELL 4.UN-EVEN FULL-HALF RATE DISTRIBUTIONS 5.OVERSHOOTING CELL 6.DIRECTED RETRY DISABLED IN THE CELL 7.HARDWARE ALARMS OR FAULTY HARDWARE ON THE CELL 8.HARDWARE LOCKED AT THE SITE SOLUTIONS:1.CAPACITY ADDITION OR NEW CAPACITY INFILL REQUIRED 2.NEIGHBOR OPTIMIZATION 3.ENABLE DUAL RATE IN THE CELL 4.CHECK THE FRL-FRU SETTINGS 5.PHYSICAL OPTIMIZATION AT THE SOURCE AND NEIGHBORING CELLS 6.ENABLE DIRECTED RETRY 7.ALARMS RECTIFICATION 8.ALL TRX SHOULD BE IN THE ACTIVE STATE

5 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

SDCCH DROP
REASON:1.POOR U/L AND D/L SIGNAL STRENGTH 2.HIGH UPLINK INTERFERNCE 3.HIGH INTERFERNCE ON THE BCCH FREQUENCY 4.FAULTY HARDWARE ISSUES 5.HARDWARE ALARMS 6.PROBLEM IN DIP AND SYNCHRONIZATION 7.MULTI BAND SYNCHRONIZATION PROBLEMS 8.COVERAGE HOLES 9.HIGH LAC UPDATIONS SOLUTIONS:1.CHECK THE FEEDER PATHS AND OUTPUT POWER OF THE TRX AND THE BTS 2.CHECK AND AVOID THE OVERLAPS OF THE CELLS 3.SHIFT THE SDCCH CHANNEL ON THE OTHER CHANNEL GROUP (i.e. from bcch trx to hopping trx) 4.CHECK REPORTS FOR HARDWARE QUALITY AND PATH LOSS 5.CLEARANCE OF ALARMS 6.CHECK THE E1 PATCHING 7.CHECK THE SYNC CABLE FOR MASTER AND SLAVE BTS 8.RETUNE THE RXP VALUE 9.LAC REPLAN AND OPTIMIZE CRH AND C2 VALUES

6 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

TCH ASSIGNMENT SUCCESS RATE


REASONS 1.HARDWARE ISSUES 2.HIGH TCH BLOCKING 3.OVERSHOOTING 4. FULL OR PARTIAL CABLE SWAP IN THE BTS

SOLUTIONS:1.CHECK THE CABLE PATHS,LOOSE CONNECTIONS,ALARMS 2.CAPACITY ADDITION 3.TILT FINE TUNING REQUIRED AT THE CELL OR USE TMA FOR UPLINK PATH 4.CHECK THE PARTIAL SWAP IN THE BTS(2 SECTORS OF THE SAME BTS MAY HAVING A PARTIAL SAWP)

7 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX

TCH DROP
REASONS:1.POOR U/L AND D/L SIGNAL STRENGTH 2.POOR BCCH SELECTION 3.OVERSHOOTING 4.POOR HOSR 5.HARDWARE ISSUES AND ALARMS 6.BAD UPLINK QUALITY(ICM) 7.OUTAGE 8.TR FAILS 9.WRONG PARAMETER SETTINGS(RLT,RXP) 10.CABLE SWAP 11.WRONG MO,MS AND HSN SOLUTIONS:1.CHECK THE FEEDER PATHS,CONNECTIONS,USE TMA FOR UPLINK PATH 2.CHECK YOUR BCCH PLAN 3.PHYSICAL FINE TUNING REQUIRED 4.HARDWARE ISSUES AT THE TARGET CELL 5.CHECK REPORTS FOR TRX QUALITY AND REMOVAL OF HARDWARE ALARMS 6.USE BPF OR REDUCE THE OVERLAPS WITH THE ADJACENT CELLS 7.CHECK THE OUTAGE CAUSES 8.CHECK THE E1 TRAFFIC MAPPING AT BOTH BTS AND BSC END 9.CHECK THE PARAMETER SETTINGS 10.CHECK THE CABLE CONNECTIONS 11.HOPPING PLAN RE CHECK REQUIRED
8 | Presentation Title | Month 2008 All Rights Reserved Alcatel-Lucent 2008, XXXXX

HANDOVER SUCCESS RATE


REASONS:1.IMPROPER NEIGBOUR PLAN (i.e. non-symmetrical neighbors) 2.CHECK PLANED VS ACTUAL DATABASE IN THE SYSTEM 3.SL VALUES 4.OVERSHOOTING 5.DAC VALUE MISMATCH 6.SYNC MISMATCH 7.HARWARE ALLARS AND FAULTY HARDWARE SOLUTIONS:1.CHECK THE NEIGHBOUR PLAN,MAX 12 NEIGHBOUR SHOULD BE CREATED,NBR SHOULD BE BOTH WAYS. 2.CHECK THE NBRs WITH SAME NCC+BCC+BCCH COMBINATIONS,WRONG MNC AND LAC DEFINITION 3.SL VALUE SHOULD NOT BE VERY LESS 4.PHYSICAL FINE TUNING REQUIRED. 5.DAC VALUE SHOULD BE EITHER +/-150 FROM 2048 IN THE BCF OF ALL THE ADJACENCIES AND SOURCE CELL AS WELL

6.CHECK THE REPORTS AND ENABLE SYNC FOR THE INTRA CELL RELATIONS

9 | Presentation Title | Month 2008

All Rights Reserved Alcatel-Lucent 2008, XXXXX