Академический Документы
Профессиональный Документы
Культура Документы
Value OTOURECEIVETH HOOLRXLEVOFFSET ULDLOFFS 5 FBOFFSP 9 Input area OLHYST OTOURECEIVETH HOOLRXLEVOFFSET 5 15 35 Intracell HO UTOORECTH Threshold A Threshold B 16 35
28 32 28
23 36 22 22
Step 1 2 3 4 5 6 7 8 9 10 11 12
Design Steps: Calculate FBOFFSP from antenna EIRP etc. ULDLOFFS = 7 dB approx. Select OTOURECEIVETH based on radio network Select OLHYST (5dB is better) Intracell HO: Select HOOLRXLEVOFFSET = 31 Calculate UTOORECTH = OTOURECEIVETH + OLHYST + FBOFFSP Calculate Threshold A = UTOORECETH + (HOOLRXLEVOFSET - 31) Calculate Threshold B = UTOORECTH Assignment to OL: Calculate Threshold A = UTOORECTH - ULDLOFFS (As Assignments are calculated in Uplink; HO Threshold B is selected as Calculate ASSOLRXLEVOFFSET from the Equation: Threshold A = OTOURECEIVETH + (ASSOLRXLEVOFFSET - 31) Calulate OPTILEVTHRES allowing 2 dB offset from Threshold A Threshold B = OPTILEVTHRES
-96 -87
-82
-101 -92
-87
-100 -91
-86
OPTILEV 23 1 10 OTOU 14 9
En Iuo In Cell Load classification HO Period Cell Name UL to OL HO Allowed OL to UL HO Allowed RX_LEV for UO HO Allowed RX_QUAL for UO HO Allowed TA for UO HO Allowed UO Signal Intensity Difference RX_LEV Threshold RX_LEV Hysteresis RX_QUAL Threshold TA Threshold TA Hysteresis UO HO Watch Time(s) UO HO Valid Time(s) Assign Optimum Layer Assign-optimum-level Threshold TA Threshold of Assignment Pref. TA Pref. of Imme-Assign Allowed TA Threshold of Imme-Assign Pref. Pref. Subcell in HO of Intra-BSC Incoming-to-BSC HO Optimum Layer OtoU HO Received Level Threshold UtoO HO Received Level Threshold UtoO Traffic HO Allowed Underlay HO Step Period(s) Penalty Time of UtoO HO(s) Penalty Time after UtoO HO Fail(s) Penalty Time after OtoU HO Fail(s) MaxRetry Time after UtoO Fail En Iuo Out Cell Low Load Threshold En Iuo Out Cell General OverLoad Threshold En Iuo Out Cell Serious OverLoad Threshold En Iuo In Cell Load classification HO Period En Iuo In Cell Load classification HO Step Receive Quality Threshold (AMRFR) Receive Quality Threshold (AMRHR) Underlay HO Step Level IniLev For EnUtoO Load HO(Voltage Level)
0 cell0 YES YES YES NO YES 0 35 5 60 63 0 5 4 Underlaid Subcell 35 63 NO 0 System Optimization Underlaid Subcell 25 35 NO 5 10 40 10 3 20 85 90 5 5 65 60 5 63
UL Assign-optimum-level Threshold OtoU HO Received Level Threshold UtoO HO Received Level Threshold
-91
-88
UL Assign-optimum-level Threshold OtoU HO Received Level Threshold UtoO HO Received Level Threshold
24 18 30 38 31
900 -89
DL1800 -95 14
DL900 23
UL900 17
Safe 20
if Cong 19
Param Assign-optimum-level Threshold(UL) OtoU HO Received Level Threshold UtoO HO Received Level Threshold
Value
DL900
DL1800 23 19 22 2 0 16 16 12 15
DL900
17 12 22 33 31
-94
5 10 O to U Assign U to O 12 17 22