There will be 4 part on this TRIAL MOCN(1A,1B,2C,2D) U Mobile You will be doing 1B today The sites involved are

between ADAU sectors ADAU PSC 221,229,237 You can refer to the excel sheet(cell info) also for the cell information

Tools needed ; 1 Scanner scan W2100 (10612,10637,10662,10686) and W900(2939) 2 UE i) UE1-1 unit D51 ii) UE2-1 unit U800 4 SIM CARDS i) 2 unit maxis simcard ii) 2 unit u mobile simcard *make sure UE1 is D51 and UE2 is U8800 for all the test cases You have to do for idle mode and also dedicated mode ( cs and ps)(refer to excel) The Test plan for CS dedicated mode will be long call to PSTN(both ues) PSTN number for U mobile sim : 03 56321311 Make sure data services are disabled when doing cs The Test plan for HS/PS dedicated mode will be PS Download(both ues) Data services are enabled when doing ps

You need to lock the UE frequency according to the excel sheet in the beginning of the drive and then unlock it back( in order for it perform handover from the specific frequency and band) For todays part, it will be easy because it is between: IRAT (W900 to GSM) for U mobile sim Please monitor the probe to make sure that cell reselection/handover happens to the correct cell and frequency Make sure the cell reselection/handover happens before you stop the logfiles

For 1B part You have to drive from ADAU sector1 to ADAU sector2(same frequency) for all the test cases There will be 9 logfiles for this part W900 (idle,idle)(cs,ps),(ps,cs) W2100 10637 (idle,idle)(cs,ps),(ps,cs) W2100 10612 (idle,idle)(cs,ps),(ps,cs) Name the logfiles as sample below for w2100 10612 (ue1_idle/voice/dl ue2_idle,voice,dl)