REMARKS
SOILS
GEOTECHNICAL INVESTIGATIONS 1803 GEOTECHNICAL INVESTIGATION SHALL INCLUDE ITEMS OF SPECIAL INSPECTION AND TESTING AS NOTED IN TABLE 5 OF THE GUIDELINES X (a) TABLE 1704.7 GEOTECHNICAL REPORT X X BY THE GEOTECHNICAL ENGINEER
VERIFY FOOTING BEARING CAPACITY AND SUBGRADE PREPARATION FOR FILLS FILL MATERIAL VERIFICATION FILL PLACEMENT & COMPACTION VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL PERFORM CLASSIFICATION OF COMPACTED FILL MATERIALS VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY
X (a)
TABLE 1704.7
PILING
INSTALLATION 1704.8 GEOTECHNICAL REPORT X BY THE GEOTECHNICAL ENGINEER
VERIFY ELEMENT MATERIALS, SIZES AND LENGTHS COMPLY WITH THE REQUIREMENTS
TABLE 1704.8
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
SOILS
TABLE 1704.8 X OBSERVATION BY GEOTECHNICAL ENGINEER
TABLE 1704.8
TABLE 1704.8
FOR STEEL ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCE WITH SECTION 1704.3 FOR CONCRETE ELEMENTS AND CONCRETEFILLED ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCE WITH SECTION 1704.4
TABLE 1704.8
TABLE 1704.8
FOR SPECIALTY ELEMENTS, PERFORM ADDITIONAL INSPECTIONS AS DETERMINED BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
TABLE 1704.8
PIER FOUNDATIONS
DRILLING AND TESTING OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS FOR EACH ELEMENT TABLE 1704.9 TABLE 1704.9 GEOTECHNICAL REPORT X BY THE GEOTECHNICAL ENGINEER
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
SOILS
VERIFY PLACEMENT LOCATIONS AND PLUMBNESS, CONFIRM ELEMENT DIAMETERS, BELL DIAMETERS (IF APPLICABLE), LENGTHS, EMBEDMENT INTO BEDROCK (IF APPLICABLE) AND ADEQUATE END-BEARING STRATA CAPACITY. RECORD CONCRETE OR GROUT VOLUMES. FOR CONCRETE ELEMENTS, PERFORM ADDITIONAL INSPECTIONS IN ACCORDANCE WITH SECTION 1704.4
TABLE 1704.9
TABLE 1704.9
SCREW ANCHORS
GEOTECHNICAL, RESEARCH AND/OR REPORT AND ICC EVALUATION REPORTS BY THE GEOTECHNICAL ENGINEER SPECIAL INSPECTIONS APPLY TO VERIFYING MANUFACTURER'S CERTIFICATION OF INSTALLERS, HELICAL ANCHOR AND BRACKET PRODUCT NAME, TYPES, INSTALLATION EQUIPMENT USED, FINAL TORQUE, PILE DIMENSIONS, EMBEDMENT DEPTH AND TIP EVALUATION
INSTALLATION
1704.10
INSTALLATION
1704.15
TENSION ANCHORS
INSTALLATION 1704.15 STRESSING GEOTECHNICAL REPORT X BY THE GEOTECHNICAL ENGINEER SPECIAL INSPECTIONS APPLY TO TENDON TYPE AND SIZE, CORROSION PROTECTION, DEPTH OF EMBEDMENT, BONDED LENGTH, TYPE OF GROUT USED, AND RECORD OF PRESTRESS
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
INSTALLATION
1704.15
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
FABRICATORS
SPECIAL INSPECTIONS APPLY TO VERIFICATION OF DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES INCLUDING REVIEW FOR COMPLETENESS AND ADEQUACY RELATIVE TO THE CODE REQUIREMENTS
FABRICATORS
1704.2
CONCRETE
INSPECTION OF ANCHORS INSTALLED IN HARDENED CONCRETE REINFORCING STEEL AND PRESTRESSING TENDON PLACEMENT 1912.1 1704.4 1907.5 1913.4 1901.4.2 1704.3.1 1903.1 TABLE 1704.4 ACI 318: 3.8.6, 8.1.3, 21.1.8 ACI 318: 3.5 ACI 318: 7.1-7.7 X (a)
TOLERANCES AND REINFORCING PLACEMENT PER ACI 7.5; SPACING LIMITS FOR REINFORCING ACI 7.6 REFER TO STEEL FOR WELDING REQUIREMENTS TABLE 1704.3, ITEM 5b
WELDING REINFORCING STEEL 1) VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHER THAN ASTM A 706
ACI 318: 3.5.2 AWS D1.4 AWS D1.4 ACI 318: SECTION 3.5.2
2) REINFORCING STEEL RESISTING FLEXURAL AND AXIAL FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL WALLS OF CONCRETE AND SHEAR REINFORCEMENT
X (b)
3) SHEAR REINFORCEMENT
AWS D1.4 ACI 318: SECTION 3.5.2 TABLE 1704.4 TABLE 1704.4 1911.5 1912.1 AWS D1.4 ACI 318: SECTION 3.5.2 ACI 318: 1.3.2.C ACI 318: 8.1.3 ACI 318: 21.1.8
4) OTHER REINFORCING STEEL. PLACEMENT OF BOLTS INSTALLED IN CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCREASED OR WHERE STRENGTH DESIGN IS USED
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
FABRICATORS
CONCRETE PLACEMENT
SHOTCRETE PLACEMENT
X (a)
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
FABRICATORS
b. GROUTING OF BONDED PRESTRESSING TENDONS IN THE SEISMIC-FORCERESISTING SYSTEM ACI 318: 18.18.4 X
X (a)
ALL CONNECTIONS VISUALLY INSPECTED REFER TO ANCHOR BOLT WELDING REQUIREMENTS AND STRUCTURAL INTEGRITY PROVISIONS
VERIFICATION OF IN-SITU CONCRETE PRIOR TO REMOVAL OF FORMS AND SHORES FROM ELEVATED BEAMS AND STRUCTURAL SLABS
X (a)
VERIFICATION OF FORMWORK
X (a)
SPECIAL INSPECTIONS APPLY TO SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED
MASONRY LEVEL 1
COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THE APPROVED SUBMITTALS SHALL BE VERIFIED VERIFICATION OF F'm AND F'aac PRIOR TO CONSTRUCTION EXCEPT WHERE SPECIFICALLY EXEMPTED BY THIS CODE
VERIFICATION OF SLUMP FLOW AND VSI AS TMS 602: 1.5B.1.b.3 X DELIVERED TO THE SITE FOR SELFCONSOLIDATING GROUT. AS MASONRY CONSTRUCTION BEGINS, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE: A) VERIFICATION OF SITE-PROPORTIONED MORTAR B) LOCATION OF REINFORCEMENT AND CONNECTORS AND PRESTRESSING TENDONS AND ANCHORAGE TMS 602: 2.6 A X
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
FABRICATORS
C) CONSTRUCTION OF MORTAR JOINTS TMS 602: 3.3 B X (a)
D) VERIFICATION OF PRESTRESSING TECHNIQUE E) GRADE AND SIZE OF PRESTRESSING TENDONS AND ANCHORAGE
DURING CONSTRUCTION THE INSPECTION PROGRAM SHALL VERIFY: A) SIZE AND LOCATION OF STRUCTURAL ELEMENTS B) ANCHORAGE OF MASONRY TO FRAMES, STRUCTURAL MEMBERS, AND DIAPHRAGMS TMS 602: 3.3 F TMS 402: 1.16.1 TMS 402: 1.2.2 (e) TMS 402: 2.1.4 TMS 402: 3.1.6 TMS 402: 1.15 TMS 602: 2.4 TMS 602: 3.4 TMS 402: 2.1.9.7.2 TMS 402: 3.3.3.4 (b) X
X (a)
(b)
C) SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT, ANCHOR BOLTS, PRESTRESSING TENDONS AND ANCHORAGES. D) WELDING REINFORCING STEEL PREPARATION, CONSTRUCTION, AND PROTECTION DURING COLD WEATHER (TEMPERATURE BELOW 40F) AND HOT WEATHER (TEMPERATURE ABOVE 90F)
2104.3 2104.4
X (a)
(b)
PRIOR TO GROUTING, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE: VERIFYING GROUT SPACE IS CLEAN PRIOR TO GROUTING PLACEMENT OF REINFORCEMENT AND CONNECTORS AND PRESTRESSING TENDONS AND ANCHORAGES TMS 602: 3.2D X (b)
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
PROPORTIONS OF SITE PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS CONSTRUCTION OF MORTAR JOINTS GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE COMPLIANCE GROUT PLACEMENT AT PRESTRESSING TENDONS PREPARATION OF ANY REQUIRED GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS SHALL BE OBSERVED
FABRICATORS
TMS 602: 2.6B X
2105.2.2 2105.3
MASONRY LEVEL 2
COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THE CONSTRUCTION DOCUMENTS AND THE APPROVED SUBMITTALS VERIFICATION OF F'm AND F'AAC PRIOR TO CONSTRUCTION AND FOR EVERY 5,000 SQUARE FEET DURING CONSTRUCTION VERIFICATION OF PROPORTIONS OF MATERIALS IN PREMIXED OR PREBLENDED MORTAR AND GROUT AS DELIVERED TO THE SITE VERIFICATION OF SLUMP FLOW AND VSI AS DELIVERED TO THE SITE FOR SELFCONSOLIDATING GROUT VERIFICATION OF SITE-PREPARED MORTAR, GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS PLACEMENT OF MASONRY UNITS AND MORTAR JOINT CONSTRUCTION TMS 602: 1.5 X
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
REMARKS
VERIFICATION OF SIZE AND LOCATION OF STRUCTURAL ELEMENTS TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES OR OTHER CONSTRUCTION
FABRICATORS
TMS 602: 3.3F X
(b)
TYPE, GRADE, AND SIZE OF REINFORCING STEEL, ANCHOR BOLTS, PRESTRESSING TENDONS AND ANCHORAGES PLACEMENT OF REINFORCEMENT, CONNECTORS, PRESTRESSING TENDON AND ANCHORAGE WELDING REINFORCING STEEL PREPARATION, CONSTRUCTION, AND PROTECTION DURING COLD WEATHER (TEMPERATURE BELOW 40F) AND HOT WEATHER (TEMPERATURE ABOVE 90F)
TMS 402: 1.15 TMS 602: 2.4 TMS 602: 3.4 TMS 402: 1.15 TMS 602: 3.4 TMS 602: 3.6A TMS 402: 2.1.9.7.2 TMS 402: 3.3.3.4 (b) X
X (a)
2104.3 2104.4
X (a)
STRESSING OF PRESTRESSING TENDONS APPLICATION AND MEASUREMENT OF PRESTRESSING FORCES GROUT PLACEMENT GROUT SPACE PRIOR TO GROUTING GROUT PLACEMENT AT PRESTRESSING TENDONS PREPARATION OF ANY REQUIRED GROUT SPECIMENS, MORTAR SPECIMENS AND/OR PRISMS SHALL BE OBSERVED 2105.2.2 2105.3
TMS 602: 3.6B TMS 602: 3.5 TMS 602: 3.2D TMS 602: 3.6C
X X X X
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
10
REMARKS
FABRICATORS STEEL
FABRICATION OF STRUCTURAL ELEMENTS 1704.2 ASTM A6 ASTM STANDARDS SPECIFIED IN CONSTRUCTION DOCUMENTS AISC 360 A3.1 AISC 360 M5.5 ASTM STANDARDS SPECIFIED IN CONSTRUCTION DOCUMENTS RCSC 2.1 AISC 360 A3.4 ASTM STANDARDS SPECIFIED IN CONSTRUCTION DOCUMENTS AISC 360 A3.5 APPLICABLE AWS A5 DOCUMENTS X REFER TO INSPECTION OF FABRICATOR REQUIREMENTS
1704.3 2203.1
1704.3.3
1704.3
1704.3.1
VERIFYING USE OF PROPER WPS'S VERIFYING WELDER QUALIFICATIONS COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS MULTIPASS FILLET WELDS 1704.3.1 AWS D1.1 SECTION 6 X
X X
X ALL WELDS VISUALLY INSPECTED PER AWS D1.1 6.9 1704.3.1 SINGLE PASS FILLET WELDS GREATER THAN X 5/16" AWS D1.1, SECTION 6 TABLE PLUG AND SLOT WELDS X 1704.4 SINGLE PASS FILLET WELDS LESS THAN OR X EQUAL TO 5/16" (a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
11
REMARKS
FABRICATORS
ICC EVALUATION REPORT ASCE 9 CHAPTER 3 X SPECIAL INSPECTIONS APPLY TO DECKING TYPE, DEPTH, GAGE, AND FASTENING
SPECIAL INSPECTIONS APPLY TO DECKING TYPE, DEPTH AND GAGE, POWER ACTUATED FASTENERS, SCREWS, PROPRIETARY SIDE SEAM ATTACHMENTS, BUTTON PUNCHES AND SHEAR CONNECTORS ALL WELDS INSPECTED PER AWS D1.3 7.1
TABLE 1704.3
RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS SECTION 9 AISC 360, SECTION M2.5 X
ALL CONNECTIONS INSPECTED. CONNECTIONS USING DIRECT TENSION INDICATORS, ALL BOLTS SHALL BE INSPECTED AFTER SNUGGING AND AFTER PRETENSIONING
1704.3.2
X (a)
1703.4.1 1704.15
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
12
REMARKS
X X
TABLE 1704.3
X X X
ALL WELDS VISUALLY INSPECTED PER AWS D1.4.7.5 ALL WELDS VISUALLY INSPECTED PER AWS D1.4.7.5
STAINLESS STEEL
FABRICATION OF STAINLESS STEEL ELEMENTS MATERIAL VERIFICATION OF STAINLESS STEEL MATERIAL VERIFICATION OF BOLTS MATERIAL VERIFICATION OF WELD FILLER METALS VERIFYING USE OF PROPER WPS'S VERIFYING WELDER QUALIFICATIONS 1704.3.1 COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS MULTIPASS FILLET WELDS SINGLE PASS FILLET WELDS MATERIAL VERIFICATION OF WELD FILLER METALS 1704.3.2 Exception 2 & 1704.3.1.2 AWS D1.6 SECTION 6 X X X ALL WELDS VISUALLY INSPECTED PER AWS D1.6 6.28.1 1704.2 1704.3 1704.3 X X X X X X REFER TO INSPECTION OF FABRICATOR REQUIREMENTS CERTIFIED MILL TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS COPY OF WELDING PROCEDURE SPECIFICATIONS COPY OF QUALIFICATION CARDS
1704.3.1.2
AWS D1.3
1704.3 VERIFYING WELDER QUALIFICATIONS COPY OF QUALIFICATION CARDS X Exception 2 (a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
13
REMARKS
FABRICATORS
ALL WELDS VISUALLY INSPECTED PER AWS D1.3 7.1 VERIFY THAT THE TEMPORARY INSTALLATION RESTRAINT/BRACES AND THE PERMANENT INDIVIDUAL TRUSS MEMBER RESTRAINT/BRACING ARE INSTALLED IN ACCORDANCE WITH THE APPROVED TRUSS SUBMITTAL PACKAGE
1704.3.4
1912.1
ALUMINUM
MATERIAL VERIFICATION OF STRUCTURAL ALUMINUM MATERIAL VERIFICATION OF BOLTS MATERIAL VERIFICATION OF WELD FILLER METALS VERIFYING USE OF PROPER WPS'S VERIFYING WELDER QUALIFICATIONS COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS MULTIPASS FILLET WELDS SINGLE PASS FILLET WELDS AWS D1.2 SECTION 5 X X X ALL WELDS VISUALLY INSPECTED PER AWS 1.2, 5.5 1704.15 X X X X X CERTIFIED MILL TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS COPY OF WELDING PROCEDURE SPECIFICATIONS COPY OF QUALIFICATION CARDS
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
14
REMARKS
FABRICATORS WOOD
FABRICATION OF PREFABRICATED STRUCTURAL ELEMENTS 1704.2 X REFER TO INSPECTION OF FABRICATOR REQUIREMENTS
B. VERIFY NOMINAL SIZE OF FRAMING MEMBERS AT ADJOINING PANEL EDGES C. VERIFY NAIL OR STAPLE DIAMETER AND LENGTH, NUMBER OF FASTENER LINES AND SPACING BETWEEN FASTENERS IN EACH LINE AND AT EDGE MARGINS PREFABRICATED WOOD SHEAR PANELS
1703.4 1704.15.3
SPECIAL INSPECTIONS APPLY TO HOLDOWN ANCHOR SIZE AND PLACEMENT, INCLUDING EMBEDMENT LENGTH, SPACING, AND EDGE DISTANCE
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
15
REMARKS
CONDITIONS OF SUBSTRATE
1704.12
APPLICATION WRITTEN INSTRUCTION OF APPROVED MANUFACTURER X
SPECIAL INSPECTIONS APPLY TO USE OF APPROVED MATERIAL VERIFICATION, MATERIAL EXPIRATION, HANDLING, STORAGE, MIXING, CONVEYANCE, METHOD OF APPLICATION, CURING, VENTILATION, THICKNESS, DENSITY, BOND STRENGTH AND CONDITION OF APPLICATION, AND PATCHING
CONDITIONS OF SUBSTRATE
SPECIAL INSPECTIONS APPLY TO CLEANLINESS AND TEMPERATURE OF SUBSTRATE AND THE ACCEPTABILITY OF PRIMED, PAINTED, OR ENCAPSULATED STEEL
1704.13 SPECIAL INSPECTIONS APPLY TO USE OF APPROVED MATERIAL VERIFICATION, MATERIAL EXPIRATION, HANDLING, STORAGE, MIXING, CONVEYANCE, METHOD OF APPLICATION, PROTECTION, CURING, VENTILATION, THICKNESS, VOIDS REPAIR, CONDITION OF APPLICATION, AND PATCHING
APPLICATION
1704.14.1
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
16
REMARKS
INSTALLATION
1704.16
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
17
REMARKS
PRE-ENGINEERED STRUCTURES
FABRICATION AND ERECTION 1704.15 X (b) X REFER TO TABLE 2 OF THIS PLAN FOR FABRICATOR, WELDING, AND HIGH STRENGTH BOLTING SPECIAL INSPECTION REQUIREMENTS
1704.15
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
18
SYSTEM or MATERIAL
REMARKS
Continuous Periodic
GEOTECHNICAL
GEOTECHNICAL ENGINEER TO PERFORM TESTING OF COMPACTED FILL MATERIALS FILL IN-PLACE DENSITY OR PREPARED SUBGRADE DENSITY 1704.7 MATERIAL VERIFICATION 1803 VARIES; MINIMUM PER IBC APPENDIX J107.5 VARIES; CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS TESTING PER GEOTECHNICAL REPORT
X (a)
X (a)
TENSION ANCHORS
PERFORMANCE TEST FIRST (X) ANCHORS TO xxx% DL AND PROOF PER GEOTECHNICAL REPORT LOAD REMAINING ANCHORS TO xxx% DL
CONCRETE
AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
TABLE 1704.4
FABRICATE SPECIMENS AT TIME FRESH CONCRETE IS PLACED ONCE EACH DAY FOR A GIVEN CLASS OF CONCRETE, OR LESS THAN ONCE FOR EACH 150 YDS OF CONCRETE, OR LESS THAN ONCE FOR EACH 5,000 FT2 OF SURFACE AREA FOR SLABS/WALLS. ONCE EACH SHIFT FROM IN-PLACE WORK OR FROM TEST PANEL AND MINIMUM ONE SPECIMEN FOR EACH 50 CUBIC YARDS. "PRECONSTRUCTION TESTS AS REQUIRED PER THE BUILDING OFFICIAL."
CONCRETE STRENGTH
ASTM C39
X X X
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
19
SYSTEM or MATERIAL
REMARKS
Continuous Periodic
GEOTECHNICAL
1704.4 1913.10 IBC 1913.10.1: SPECIMENS SHALL BE TAKEN FROM THE INPLACE OR FROM TEST PANELS, AND SHALL BE TAKEN AT LEAST ONCE EACH SHIFT, BUT NOT LESS THAN ONE FOR EACH 50 CUBIC YARDS OF SHOTCRETE
SHOTCRETE STRENGTH
ASTM C39
MASONRY
ASTM C62 ASTM C216 ASTM C652 ASTM C476 ASTM C55 ASTM C90 TESTING EVERY 5,000 FT2
2105.2.2.1
2105.2.2.2
ASTM C1314
(1) TEST PER DAY FOR 3 CONSECUTIVE WORK DAYS AT THE START OF THE JOB. ONE TEST SHALL CONSIST OF 3 SPECIMENS. AFTER THE FIRST THREE TESTS, SPECIMENS FOR CONTINUING QUALITY CONTROL SHALL BE TAKEN ONCE A WEEK, OR FOR EVERY 5,000 SQ. FT. OF WALL, WHICHEVER IS FIRST. AT THE START OF GROUTING OPERATIONS, TAKE ONE TEST PER DAY FOR THE FIRST THREE DAYS. THE TESTS SHALL CONSIST OF 3 SPECIMENS. AFTER THE FIRST 3 TESTS, SPECIMENS FOR CONTINUING QUALITY CONTROL SHALL BE TAKEN ONCE A WEEK OR FOR EVERY 30 CU. YDS. OF GROUT OR FOR EVERY 5,000 SQ. FT. OF WALL, WHICHEVER COMES FIRST.
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
20
SYSTEM or MATERIAL
REMARKS
Continuous Periodic
GEOTECHNICAL STEEL
MAGNETIC PARTICLE (MT) AND ULTRASONIC (UT) TESTING OF WELDS PRE-CONSTRUCTION TESTING OF WELDING STUDS PRE-INSTALLATION TESTING OF WELDING STUDS WELDED THROUGH DECKING 1704.3.1.1 MT - AWS D1.1 6.14.4 UT - AWS D1.1 6.13 & 6.14.3 AWS D1.1 7.7.1 PER DRAWINGS EACH SIZE AND TYPE OF STUD EACH SHIFT EACH STUD SIZE AND DECK GAGE COMBINATION
1704.3.1
1704.3.1
1704.3.3
RCSC SPECIFICATION EACH COMBINATION OF FOR STRUCTURAL DIAMETER, LENGTH, JOINTS USING ASTM GRADE, AND LOT TO BE A325 OR A490 BOLTS USED IN THE WORK SECTION 7
STAINLESS STEEL
ULTRASONIC (UT) TESTING OF WELDS 1704.3.1 UT-AWS D1.6 6.13 PER DRAWINGS
ALUMINUM
LIQUID PENETRANT (PT) AND RADIOGRAPHIC (RT) TESTING OF WELDS PT - AWS D1.2 5.7.5 RT - AWS D1.2 5.10 & 5.15 PER DRAWINGS
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
21
SYSTEM or MATERIAL
REMARKS
Continuous Periodic
THICKNESS DETERMINED FOR NOT LESS THAN 25% THE STRUCTURAL MEMBERS EACH FLOOR LEVEL
DETERMINED FROM EACH FLOOR, ROOF, AND WALL ASSEMBLY AT A RATE OF NOT LESS THAN ONE SAMPLE FOR EVERY 2500 SF IN EACH STORY
1704.12.5
DETERMINED FROM EACH TYPE OF STRUCTURAL MEMBER AT A RATE OF NOT LESS THAN ONE SAMPLE FOR EVERY 2500 SF IN EACH STORY
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
22
SYSTEM or MATERIAL
REMARKS
Continuous Periodic
1704.12.6.2
ASTM E736
THICKNESS
1704.13
1704.14.1
See ASTM
A WATER-RESISTIVE BARRIER COATING COMPLYING WITH ASTM E 2570 REQUIRES SPECIAL INSPECTION OF THE WATER-RESISTIVE BARRIER COATING WHEN INSTALLED OVER A SHEATHING SUBSTRATE.
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
23
REMARKS
CONCRETE
CONCRETE SEISMIC-FORCE-RESISTING SYSTEMS (SEISMIC CATEGORIES C, D, E, F) (OCCUPANCY CATEGORIES III & IV) ACI 318 X (b)
1707.1 REINFORCING STEEL PLACEMENT IN SPECIAL MOMENT RESISTING FRAMES TABLE 1704.4 1707.1 TABLE 1704.4 ACI 318 1.3.5 X
INSPECTORS ARE TO BE QUALIFIED TO PERFORM THESE INSPECTIONS WHICH INCLUDES, BUT IS NOT LIMITED TO, THE PLACEMENT, STIRRUPS PLACEMENT, LAP LOCATION AND SPLICES, JOINT REINFORCEMENT PLACEMENT, ETC.
ACI 318: 18.18.1 ACI 318: 18.18.2 ACI 318: 18.18.3 ACI 318: 18.18.4
MASONRY
SEISMIC-FORCE-RESISTING SYSTEMS IN STRUCTURES OF SEISMIC DESIGN CATEGORY C, D, E OR F (OCCUPANCY CATEGORIES III AND IV)* SEISMIC SYSTEMS IN STRUCTURES OF SEISMIC DESIGN CATEGORY D, E OR F (OCCUPANCY CATEGORIES III AND IV)*
1707.1 (1)
X (b)
1707.1 (2)
X (b)
STEEL
REFER TO TABLE 2 OF GUIDELINES FOR FABRICATOR AND WELDING SPECIAL INSPECTION REQUIREMENTS. ENGINEER OF RECORD TO CLEARLY INDICATE THE SCOPE OF INSPECTIONS ON DRAWINGS. IBC 1707.2 AND 1708.3 REQUIRE SPECIAL INSPECTIONS AND RELATED TESTING FOR STRUCTURAL STEEL FOR THE SEISMIC FORCE RESISTING SYSTEM TO COMPLY WITH THE QUALITY ASSURANCE PLAN REQUIREMENTS OF AISC 341. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SPECIFIES THE QA PLAN WHICH SHOULD BE PROVIDED TO THE CONTRACTOR AS PART OF THE BID DOCUMENTS AND SHOULD BE CLEARLY IDENTIFIED AS SUCH. AISC RECOMMENDS THAT AISC 341 APPENDIX Q, QUALITY ASSURANCE PLAN, BE ADOPTED. AISC 341 INCLUDES COMMENTARY WHICH WILL BE HELPFUL TO ENGINEERS SPECIFYING PROJECT QA PLANS.
1707.2
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology. *State of Oregon only
24
REMARKS
CONCRETE
AISC 341 Q5.3 RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS 1707.2 MOMENT RESISTING FRAME REDUCED BEAM SECTIONS AISC 341 Q5.4 SEISMIC FORCE-RESISTING SYSTEM PROTECTED ZONES X X SPECIAL INSPECTIONS APPLY TO CONTOUR, FINISH, AND DIMENSIONAL TOLERANCES SPECIAL INSPECTIONS APPLY TO VERIFYING THAT THERE ARE NO HOLES OR UNAPPROVED ATTACHMENTS INCLUDING UNACCEPTABLE WELDS IN PROTECTED ZONES REFER TO TABLE 2 FOR HIGH STRENGTH BOLTING SPECIAL INSPECTION REQUIREMENTS
1707.4
X (b)
ALL WELDS VISUALLY INSPECTED PER AWS D1.3 7.1 EXCEPTION: SPECIAL INSPECTION IS NOT REQUIRED FOR SHEAR WALLS, BRACES, DIAPHRAGMS, DRAG STRUT AND HOLDOWNS. IF SHEATHING IS GYP OR FIBERBOARD OR IF SHEATHING IS WOOD STRUCTURAL PANEL/STEEL SHEET ONE SIDE ONLY AND FASTENER SPACING IS GREATER THAN 4" ON CENTER.
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology. *State of Oregon only
25
REMARKS
CONCRETE WOOD
FIELD GLUING OF DIAPHRAGM AND SHEAR WALL ELEMENTS FOR SEISMIC FORCERESISTING-SYSTEMS CONNECTIONS FOR DIAPHRAGM CHORDS, COLLECTORS, BRACING, AND SHEAR WALL ANCHORAGE AND HOLDOWNS X
X 1707.3
ALL CONNECTIONS VISUALLY INSPECTED SPECIAL INSPECTION IS NOT REQUIRED WHEN FASTENER SPACING IS GREATER THAN 4" ON CENTER FOR WOOD SHEAR WALLS, DIAPHRAGMS, NAILING, BUILDING AND OTHER COMPONENTS IN THE SEISMIC FORCE-RESISTING SYSTEM.
FASTENING OF DIAPHRAGM AND SHEAR WALL SHEATHING WITH EDGE NAILING < 4"
ARCHITECTURAL
INSTALLATION OF ANCHORAGE OF ACCESS FLOORS INSTALLATION OF ANCHORAGE OF CLADDING AND INTERIOR/EXTERIOR VENEER WEIGHING MORE THAN 5 PSF IN BUILDINGS MORE THAN 30 FEET IN HEIGHT ERECTION AND FASTENING OF INTERIOR NONBEARING WALLS WEIGHING MORE THAN 15 PSF IN BUILDINGS MORE THAN 30 FEET IN HEIGHT ERECTION AND FASTENING OF EXTERIOR NON-BEARING WALLS IN BUILDINGS MORE THAN 30 FEET IN HEIGHT INSTALLATION OF ANCHORAGE OF STORAGE RACKS WITH Ip = 1.5 INSTALLATION AND ANCHORAGE OF SUSPENDED CEILING SYSTEMS INSTALLATION OF OTHER SEISMIC SUPPORTS FOR DESIGNATED ARCHITECTURAL SYSTEMS AND THEIR COMPONENTS 1705.3 1707.5 1705.3 1707.6 X (a)
X (a)
1707.6
X (a)
1705.3 1707.6 1705.3 1707.5 1705.3 1705.3 1707.6 ASCE 7-05 Section 15.5.3 ASCE 7-05 Section 13.5.6
X (a)
X (a) X (a)
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology. *State of Oregon only
26
REMARKS
CONCRETE ELECTRICAL
INSTALLATION OF ANCHORAGE OF ELECTRICAL EQUIPMENT FOR EMERGENCY OR STANDBY POWER SYSTEMS INSTALLATION OF ANCHORAGE OF ALL ELECTRICAL EQUIPMENT IN SDC E OR F ONLY INSTALLATION OF VIBRATION ISOLATION SYSTEMS IN STRUCTURES ASSIGNED TO SDC C, D, E OR F WHERE THE CONSTRUCTION DOCUMENTS REQUIRE A NOMINAL CLEARANCE OF 0.25 INCHES OR LESS BETWEEN THE EQUIPMENT SUPPORT FRAME AND RESTRAINT INSTALLATION OF OTHER SEISMIC SUPPORTS FOR DESIGNATED ELECTRICAL SYSTEMS AND THEIR COMPONENTS INSTALLATION OF PIPING SYSTEM MEANT TO CARRY FLAMMABLE, COMBUSTIBLE OR HIGHLY TOXIC CONTENTS AND ITS ASSOCIATED MECHANICAL UNITS INSTALLATION OF OTHER SEISMIC SUPPORTS FOR DESIGNATED MECHANICAL SYSTEMS AND THEIR COMPONENTS 1705.3 1707.7 X (a)
1707.7
X (a)
1707.7 1707.9
X (a)
1707.7
X (a)
PROCESS MECHANICAL
1707.7
X (a)
1707.8
X (a)
BUILDING MECHANICAL
INSTALLATION OF HVAC DUCTWORK THAT WILL CONTAIN HAZARDOUS MATERIALS INSTALLATION OF FIRE PROTECTION SPRINKLER SYSTEM DESIGNATED SEISMIC SYSTEM VERIFICATION VERIFY LABEL, ANCHORAGE OR MOUNTING CONFORMS TO THE CERTIFICATE OF COMPLIANCE 1707.7 1707.1 X (a) INSPECTIONS AS REQUIRED BY LOCAL BUILDING OFFICIAL
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology. *State of Oregon only
27
REMARKS
CONCRETE REINFORCEMENT
TEST A615 REINFORCEMENT USED TO RESIST EARTHQUAKE INDUCED LOAD IN SPECIAL MOMENT FRAMES, SPECIAL STRUCTURAL WALLS, AND END COUPLING BEAMS CONNECTING STRUCTURAL WALLS IN STRUCTURE ASSIGNED TO SEISMIC DESIGN CATEGORY B, C, D, E AND F TEST A615 REINFORCEMENT FOR WELDABILITY WHEN SUCH REINFORCEMENT IS TO BE WELDED
1708.2 1708.1.1
X (b)
X (a)
1708.2 1708.1.1
X (a)
STEEL
UT OF BASE METAL THICKER THAN 1-1/2" SUBJECT TO THROUGH-THICKNESS WELD SHRINKAGE STRAINS MT OF K-AREA OF ROLLED WIDE FLANGE COLUMN WEBS ADJACENT TO DOUBLER/CONTINUITY PLATE WELDS MAGNETIC PARTICLE (MT) AND ULTRASONIC (UT) TESTING OF COMPLETE JOINT PENETRATION GROOVE (CJP) WELDS IN MATERIALS 5/16" THICK AND GREATER MT OF THERMALLY CUT SURFACES OF BEAM COPES AND ACCESS HOLES AT WELDED SPLICES AND CONNECTIONS WHEN THE FLANGE THICKNESS EXCEEDS 1 1/2" FOR ROLLED SHAPES OR THE WEB THICKNESS EXCEEDS 1 1/2" FOR BUILT-UP SHAPES MT OF THE WELD AND ADJACENT AREA IN A REDUCED BEAM SECTION (RBS) PLASTIC HINGE REGION REPAIRED BY WELDING MT OF THE ENDS OF FLANGE WELDS FROM WHICH WELD TABS HAVE BEEN REMOVED 1708.3 AISC 341 Q5.2 AWS D1.1 6.13 & 6.14.3 AISC 341 Q5.2 AWS D1.1 6.14.4 AISC 341 Q5.2 MT - AWS D1.1 6.14.4 UT - AWS D1.1 6.13 & 6.14.3 BEHIND AND ADJACENT TO EACH WELD
1708.3
EACH PLATE LOCATION IBC 1707.2 AND 1708.3 REQUIRE SPECIAL INSPECTIONS AND RELATED TESTING FOR STRUCTURAL STEEL FOR THE SEISMIC FORCE RESISTING SYSTEM TO COMPLY WITH THE QUALITY ASSURANCE PLAN REQUIREMENTS OF AISC 341. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SPECIFIES THE QA PLAN WHICH SHOULD BE PROVIDED TO THE CONTRACTOR AS PART OF THE BID DOCUMENTS AND SHOULD BE CLEARLY IDENTIFIED AS SUCH. AISC RECOMMENDS THAT AISC 341 APPENDIX Q, "QUALITY ASSURANCE PLAN", BE ADOPTED. AISC 341INCLUDES COMMENTARY WHICH WILL BE HELPFUL TO ENGINEERS SPECIFYING PROECT QA PLANS.
1708.3
1708.3
EACH LOCATION
1708.3
AISC 341 Q5.2 AWS D1.1 6.14.4 AISC 341 Q5.2 AWS D1.1 6.14.4
EACH LOCATION
1708.3
EACH LOCATION
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
28
REMARKS
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
29
REMARKS
X (a)
1706.2
X (a)
VERTICAL WINDFORCE-RESISTING SYSTEMS, INCLUDING BRACED FRAMES, MOMENT FRAMES AND SHEAR WALLS
1705.4
X (a)
CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING FIELD GLUING OPERATIONS OF ELEMENTS OF THE MAIN WINDFORCE-RESISTING SYSTEM. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF COMPONENTS WITHIN THE MAIN WINDFORCE-RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES AND HOLD-DOWNS
1706.2
X (a)
1706.2
X SPECIAL INSPECTIONS ARE NOT REQUIRED FOR WOOD SHEAR WALLS AND DIAPHRAGMS WHERE THE FASTENER SPACING IS MORE THAN 4 INCHES ON CENTER OR FOR COLDFORMED CONSTRUCTION WHERE THE SHEATHING IS GYPSUM BOARD, FIBERBOARD, OR WOOD STRUCTURAL PANEL OR STEEL SHEET ON ONE SIDE ONLY.
1706.3
X (a)
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
30
REMARKS
(a) Periodic Special Inspection frequency and timing to be defined by the registered design professional. (b) Selection to be made by the registered design professional based on building category and design methodology.
31