Вы находитесь на странице: 1из 6

SHEET FOR VALVE SIZING CALCULATIONS. CONDITION - FLOW MEDIUM LIQUID / FLOW IS BY WEIGHT.

INPUT DATA 1 2 3 4 5 6 7 SERVICE FLUID


FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w)

LIQUID 5 5 4 1 320 1.1 7 10

INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING (BAR) FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (G)

Since DELTA

Since DELTA

Since DELTA P < P1/2. Therefore, flow is subcritical.

Formula for Cv Calculation ( Flow By Weight )

Cv =

1.16w / S Gr x DELTA P

Where Gr

Cv(max) =

5.8

Cv(Nor) =

8.2

Cv(Min) =

11.7

Gr = G x ( 288

SHEET FOR VALVE SIZING CALCULATIONS.

CONDITION - FLOW MEDIUM LIQUID / VOLUMETRIC FLOW. INPUT DATA 1 2 3 4 5 6 7 SERVICE FLUID FLOW RATE (m3/hr) MAX / NOR / MIN (Q) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING (BAR) FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (G) Since DELTA P < P1/2. Therefore, flow is subcritical. 7 8 6 2 283 0.86 LIQUID

Formula for Cv Calculation ( Flow By VOLUME )

Cv =

1.16QS Gr / DELTA P

Cv(max) =

5.37

Cv(Nor) =

0.00

Cv(Min) =

0.00

SHEET FOR VALVE SIZING CALCULATIONS. CONDITION - FLOW MEDIUM GAS / FLOW IS BY WEIGHT. INPUT DATA 1 2 3 4 5 6 7 8 SERVICE FLUID FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING (BAR) FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (G) COMPRESSABILITY FACTOR (Z) 0 GAS

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By Weight )

Cv =

47.2 w S Z / S (DELTA P x (P1 + P2) Gr)

Cv(max) =

#DIV/0!

Cv(Nor) =

#DIV/0!

Cv(Min) =

#DIV/0!

SHEET FOR VALVE SIZING CALCULATIONS. CONDITION - FLOW MEDIUM GAS / FLOW IS BY VOLUME. INPUT DATA 1 2 3 4 5 6 7 8 SERVICE FLUID FLOW RATE (m3/hr) MAX / NOR / MIN (Q) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING FLUID TEMPERATURE (T) K SPECIFIC GRAVITY (G) COMPRESSABILITY FACTOR (Z)
0

GAS 10800 0.000 0.000 0.001 318 1 1 3600 0.000 0.000 0.001 4140 0.000 0.000 0.002

Since DELTA P > P1/2. Therefore, flow is critical.

Formula for Cv Calculation ( Flow By Volume )

Cv =

(Q / 295) S (G x T x Z) / (DELTA P x (P1 + P2))

Cv(max) =

#DIV/0!

Cv(Nor) =

#DIV/0!

Cv(Min) =

#DIV/0!

SHEET FOR VALVE SIZING CALCULATIONS FOR FLOW IN KG / HR & DP > P1/2 CONDITION - FLOW MEDIUM GAS / FLOW IS BY WEIGHT. INPUT DATA 1 2 3 4 5 6 7 8 9 SERVICE FLUID FLOW RATE (1000 Kg/hr) MAX / NOR / MIN (w) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING (BAR) FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (GF) COMPRESSABILITY FACTOR (Z) CRITICAL FLOW FACTOR Since DELTA P > P1/2. Therefore, flow is critical. 120 6.1 2 4.1 373 1.16 1 0.8 GAS

Formula for Cv Calculation ( Flow By Weight )

Cv =

54.5 w S Z / (CF x P1 x S GF )

Cv(max) =

1244.3

Cv(Nor) =

0.0

Cv(Min) =

0.0

SHEET FOR VALVE SIZING CALCULATIONS. CONDITION - FLOW MEDIUM GAS / FLOW IS BY VOLUME. INPUT DATA 1 2 3 4 5 6 7 8 SERVICE FLUID FLOW RATE (m3/hr) MAX / NOR / MIN (Q) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (G) COMPRESSABILITY FACTOR (Z) SELECTED Cv Match Factor (M) Since DELTA P < P1/2. Therefore, flow is subcritical. 1575 8.013 7.513 0.500 333 0.865 1 258 1 GAS 1365 8.013 7.513 0.500 220.5 8.013 2.513 5.500

Formula for Cv Calculation ( Flow By Volume )

DP

0.0