Вы находитесь на странице: 1из 168

GRUNDFOS DATA BOOKLET

CR, CRI, CRN, CRT


CRE, CRIE, CRNE, CRTE Custom-built pumps 50/60 Hz

CR, CRI, CRN, CRT,

1.

Introduction
Customised CR pumps Pumps for individual requirements

3
3 3

9.

Pump
PN 25 and PN 40 pumps Measurement of inlet pressure Pumping of liquids down to -40 C Surface treatment CRN all-stainless steel pumps CR low NPSH Horizontal inline pumps Horizontal end-suction pumps Belt-driven pumps CR(I) deep-well pumps Pump rubber parts Empty chambers Bearing flange Support bearings Bearing material Pump head positions Customised nameplate Dry-running protection Connections

36
36 36 36 37 38 38 39 42 43 45 46 46 46 47 48 48 48 48 49

Table of contents
2

2. 3.

Overview Performance range


CR CRT(E)

5 7
7 8

4. 5.

Identification
Type keys

9
9

Applications
High-pressure applications Hot-water applications Applications involving temperature control Aggressive/hazardous liquids Hygienic applications Special installation requirements Special applications

10
10 11 12 13 14 15 16

10. Certificates 6. Accessories


ATEX-approved dry-running protection Venting valve with connecting pipe

54
54

17
17 17

CR pumps with certificates

11. CRE pump solutions


CRE pump with extended functional module Customised CRE pump solutions

59
59 60

7.

Motor
VIK-approved motors Tropicalised motors cURus-, UR- and CSA-approved motors Other motor approvals ATEX-approved pumps Special voltage Motor with multiplug connection Motor with anti-condensation heater Motors with PTC sensors Motors with thermal switches Oversize motors Undersize motors Alternative enclosure class (IP) Alternative terminal box positions 4-pole motors Motor efficiency classes Other motor makes

18
18 18 18 18 19 19 20 21 22 22 23 24 25 25 25 25 25

12. How to read the curve charts


Guidelines to curve charts

65
67

13. Performance curves


CR deep-well Low-NPSH pumps CR pumps with 4-pole motor

68
68 70 86

14. Technical data


CR low-NPSH pumps

110
110

15. Technical data


CR deep-well pumps

137
137

16. Technical data


CRN pumps with magnetic drive CRN pumps with magnetic drive

139
139 142

8.

Shaft seals
Shaft seal arrangements Overview of shaft seals Shaft seal variants Double seal arrangements

26
26 26 26 27

17. Technical data


CRH(N) pumps CRH(N) pumps

153
153 154

18. Motor data


Standard 2-pole motors for CR, CRI, CRN, 50 Hz Standard 4-pole motors for CR, CRI, CRN, 50 Hz Standard 2-pole motors for CR, CRI, CRN, 60 Hz Standard 4-pole motors for CR, CRI, CRN, 60 Hz

160
160 160 161 161

19. Pumped liquids 20. Further product documentation


WebCAPS WinCAPS

162 165
165 166

CR, CRI, CRN, CRT,

1
Introduction
3

1. Introduction
This catalogue is a supplement to these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CRT, CRTE CR, CRN high-pressure pumps. It gives an overview of some of the customised solutions offered by Grundfos. If the catalogue does not provide a solution to your specific pumping needs, please contact us with a detailed description of your problem, and we will get down to work - for you!

Pumps for individual requirements


The CR pumps can be customised to meet individual requirements. This is due to the "mix-and-match" approach to customisation, where the many pump features and options are to be regarded as modules that can be combined to create the ideal pump for the job at hand. Motor options CR motors are available in many different configurations to meet the requirements presented by the power supply, the pump environment and/or the pumped liquid itself. Power supply systems vary in terms of both frequency and voltage, and required protection methods. Your environment may be explosive, very hot and/or very humid. Special conditions also apply at high altitudes. The pumped liquid can call for a special motor solution. High or low viscosities and/or high or low densities may require non-standard motor sizes. You may also need an explosion-proof variant. The installation site of the pump may require alternative positions of pump and motor parts, such as terminal box positions and vent screw positions. For further information, see section 2. Overview. Shaft seal options Extreme liquids sometimes call for extreme measures. High temperatures damage seal faces unless precautions are taken. Concern for safety can necessitate special measures for aggressive, toxic or flammable liquids. Liquids can be harmful to shaft seals because they crystallise, harden or are extremely abrasive. For further information, see section 2. Overview. Pump options The CR pump elements can handle the most demanding liquids and pressures, and be adapted to suit many other requirements. Horizontal installation if height is a limitation. Poor inlet conditions mean that NPSH values must be adjusted to avoid cavitation. Very high pressures demand special solutions. Special surface treatments or certificates may be required. For further information, see section 2. Overview. Connection options Your chosen pump elements can be fitted with exactly the connection options you need. All standards are covered, and special connection variants are available for maximum compactness, high liquid pressures etc. For further information, see section 2. Overview.

Customised CR pumps
We offer a wide range of customised variants of the CR type range for a variety of demanding industrial applications. With these multistage in-line pumps, based on the well-known CR type range, we meet the customers needs for pumps capable of handling special installation requirements and these liquids: high-temperature liquids crystallising liquids high-viscosity liquids such as paints and varnishes aggressive liquids volatile liquids flammable liquids. Most of the pumps are available with either mains-operated motors (CR, CRI, CRN and CRT) or electronically speed-controlled motors (CRE, CRIE, CRNE and CRTE). Customised pumps from CR 1s to CR 90 are available for these temperature ranges: Water-based liquids: -40 C to +180 C. Thermal oils: -20 C to +240 C. The below pump types are available as customised pumps.
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Note: CRT(E) 2, 4, 8 and 16 are also available as customised pumps.

1
Features and benefits Customised CR pumps have the following features and benefits:

CR, CRI, CRN, CRT,

GR5357

Introduction

Grundfos motor Grundfos motors are remarkably silent and highly efficient. Three-phase pumps from 1.1 to 75 kW have premium efficiency IE3 motors as standard. Grundfos motors are available with integrated frequency converter designed for speed-controlled operation. Shaft seal solutions The specially designed cartridge seal increases reliability, ensures safe handling and enables easy service and access. The cartridge shaft seal comes in a wide choice of materials. It is available in single and double seal arrangements and magnetic drive configurations. Connections The Grundfos CR pump can be connected to any system. Material options The Grundfos CR pump is available in four different material variants: CRT(E): Titanium CRN(E): Stainless steel AISI 316 CRI(E): Stainless steel AISI 304 CR(E): Stainless steel AISI 304/cast iron. Wide range of pump sizes The CR pump comes in 13 flow sizes and hundreds of pressure sizes, ensuring that you can always find exactly the right pump for the job. High-performance hydraulics Pump efficiency is maximised by the optimised hydraulics and carefully crafted production technology. Dry-running protection The patented Grundfos LiqTec system eliminates the risk of breakdowns due to dry running. If there is no liquid in the pump, the LiqTec will stop the pump immediately.

CR, CRI, CRN, CRT,

2
Overview
4-pole motors Explosion-proof motors Anti-condensation heater Multiplug connections CSA/UL-approved motors See page 25. See page 19. See page 21. See page 20. See page 18. Shaft seals Rubber parts Titanium Non-cartridge solution CR pumps with air-cooled top See page 26. See page 27. See page 26. See page 26. See page 31. CR high-pressure pumps Horizontal mounting All-stainless steel CR pumps CRH, horizontal end-suction pumps Low temperature See page 10 and 36. See page 15 and 39. See page 38. See page 42. See page 12 and 36. Oval flanges (CR) Flanges (CR) PJE connections (CRI, CRN) Flanges (CRI, CRN) Clamp connections (CRI, CRN) See page 53. See page 53. See page 52. See page 53. See page 51.

2. Overview

2
Overview
6
VIK-approved motors Oversize or Motor protection undersize motors Special voltage Enclosure class Terminal box positions

CR, CRI, CRN, CRT,

See page 18.

See page 22.

See page 23.

See page 19.

See page 25.

See page 25.

MAGdrive

Back-to-back seal arrangement

CR pump with pressure intensifier

CR pump with barrier liquid

Tandem seal arrangement

Dry-running protection

Accessories

See page 34.

See page 27.

See page 29.

See page 28.

See page 30.

See page 48.

See page 17.

Alternative colour

Bearing flange

Pump rubber parts

CR low-NPSH pumps

CR deep-well pumps

Belt-driven CR pumps

Bearing materials

Surface treatment

See page 37.

See page 46.

See page 46.

See page 11 and 38.

See page 16 and 45.

See page 15 and 43.

See page 48.

See page 37.

Oval flanges (CRI, CRN)

TriClamp connections (CRN)

Union connections (CRI, CRN)

PJE connections (CRT)

Customised solutions

Certificates

See page 53.

See page 49.

See page 53.

See page 53.

See page 53.

See page 54.

CR, CRI, CRN, CRT,

3
Performance range
200 200 200 200
TM02 1530 4408 TM02 1192 4708

3. Performance range
CR
50 Hz
H [m]
400 300 200
CR 32 CRN 32 CR 150 CRN 150 CR 120 CRN 120

50 Hz

100 80 60 40 30 20 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100


CR 1s CRI 1s CRN 1s CR 1 CRI 1 CRN 1 CR 3 CRI 3 CRN 3 CR 5 CRI 5 CRN 5 CR 10 CRI 10 CRN 10 CR 15 CRI 15 CRN 15 CR 20 CRI 20 CRN 20 CR 45 CRN 45 CR 90 CRN 90 CR 64 CRN 64

Eta [%]
80 60 40 20 0 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100

Q [m/h]

Q [m/h]

Note: CRE, CRIE, CRNE pumps are available up to 22 kW. 60 Hz


H [m]
400 300 200
CR 150 CRN 150

60 Hz

CR 120 CRN 120

100 80 60 40 30 20 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100


CR 1s CRI 1s CRN 1s CR 1 CRI 1 CRN 1 CR 3 CRI 3 CRN 3 CR 5 CRI 5 CRN 5 CR 10 CRI 10 CRN 10 CR 15 CRI 15 CRN 15 CR 20 CRI 20 CRN 20 CR 32 CRN 32 CR 45 CRN 45 CR 64 CRN 64 CR 90 CRN 90

Eta [%]
80 60 40 20 0 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100

Q [m/h]

Q [m/h]

Note: CRE, CRIE, CRNE pumps are available up to 22 kW.

3
CRT(E)
50 Hz
H [m]
300

CR, CRI, CRN, CRT,

20 1 2 3 4 5 6 7 8 9 10 20 30 40

Q [m/h]

Note: CRTE pumps are available. 60 Hz


H [m]
300

CRT
60 Hz

200

100 90 80 70 60 50 40 30

CRT 2

CRT 4

CRT 8

CRT 16

20 1 2 3 4 5 6 7 8 9 10 20 30 40

Q [m/h]

Note: CRTE pumps are available.

TM03 3818 1106

TM03 3817 1106

Performance range

CRT
50 Hz

200

100 90 80 70 60 50 40 30

CRT 2

CRT 4

CRT 8

CRT 16

CR, CRI, CRN, CRT,

4
Identification
Code Description Code for rubber parts in pump E F K V EPDM FXM (Fluoraz) FFKM (Kalrez) FKM (Viton) Shaft seal type designation A D H K O P X O-ring seal with fixed driver Balanced O-ring seal Balanced cartridge seal with O-ring Type M as cartridge seal Double seal, back-to-back Double seal, tandem Special version Seal face material B C H U Q X Carbon, synthetic resin-impregnated Other types of carbon Cemented tungsten carbide, embedded (hybrid) Cemented tungsten carbide Silicon carbide Other ceramics Secondary seal material (rubber parts) E F K V EPDM FXM (Fluoraz) FFKM (Kalrez) FKM (Viton)

4. Identification
Type keys
Pump
Example Type range: CR, CRI, CRN, CRT Pump with integrated frequency converter Flow rate [m 3/h] Undersize impeller (all impellers) CR 1s, CRI 1s, CRN 1s Number of impellers Number of reduced-diameter impellers CR(E), CRN(E) 32, 45, 64, 90, 120, 150 Code for pump version Code for pipe connection Code for materials Code for rubber parts Code for shaft seal CR E 32 s -4 -2 -A -F -G -E -HQQE

Key to codes
Code Description

Pump version
A B D DW E F

G
H HS I J K M N P R SF

V
X

Basic version Oversize motor Pump with pressure intensifier Deep-well pump with ejector Pump with certificate Pump for high temperatures (with air-cooled top) Multi-E slave Horizontal version High-pressure pump with high-speed MGE motor Different pressure rating Pump with a different maximum speed Pump with low NPSH Magnetic drive With sensor Undersize motor Horizontal version with bearing bracket High-pressure pump Multi-E master Special version

Shaft seal
Example Shaft seal type designation Material of rotating seal face Material of stationary seal face Material of secondary seal (rubber parts) -H -Q -Q -E

Pipe connection A B CA CX F G J N P X Materials A D G GI I II K S X Basic version Carbon-graphite filled PTFE (bearings) Wetted parts EN 1.4401/AISI 316 All parts stainless steel, wetted parts EN 1.4401/AISI 316 Wetted parts EN 1.4301/AISI 304 All parts stainless steel, wetted parts EN 1.4301/AISI 304 Bronze (bearings) SiC bearings + PTFE neck rings Special version Oval flange NPT thread FlexiClamp Triclamp DIN flange ANSI flange JIS flange Changed diameter of ports PJE coupling Special version

5
5. Applications
High-pressure applications
2-pump solutions

CR, CRI, CRN, CRT,

Fig. 1

CR high-pressure pumps

Reference applications Filtration reverse osmosis cleaning and washing boiler feed.

GR7767 - TM02 8470 4004

Applications
10

Our 2-pump solutions are divided into two groups based on pump size: CRN 3, 5, 10, 15, 20 SF CR(N) 32, 45, 64, 90, 120, 150. Both solutions consist of two pumps in series. The first pump is a standard pump for feeding. The second pump is a high-pressure pump especially designed for high pressure. To minimise the pressure on the shaft seal, the direction of rotation on CR SF pumps is the opposite of that of standard pumps, and the chamber stack is turned up-side down. Consequently, the pumped liquid flows in the opposite direction. Further documentation
Information about CR high-pressure pumps (standard documentation) Pumps with bearing flange Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 165 46 18-63 15 59 165

Customised solutions High-pressure applications often expose pumps to a variety of extreme conditions, such as high inlet pressure, high operating pressure, frequent starts/stops and pressure pulsing. Overload of the pump may cause increased wear of pump parts, such as motor bearings and shaft seal, and thus reduce the pump life. To avoid unexpected breakdowns, we offer customised solutions designed to meet your needs! High-pressure handling We offer high-pressure pumps specially designed to cope with pressures up to 50 bar at max. +120 C. When necessary, CR high-pressure pumps are fitted with a bearing flange. A bearing flange is an additional flange with an oversize ball bearing designed to absorb axial forces in both directions. CR high-pressure pumps come in two variants: as a single-pump solution or as a 2-pump solution. The single-pump solutions is used for flow rates up to 5 m3/h, the 2-pump solution for flow rates above 5 m3/h. Single-pump solution Our single-pump solutions include the pump types CRNE 1 HS and CRNE 3 HS. CRNE HS pumps are fitted with a high-speed motor with integrated frequency converter. To minimise the pressure on the shaft seal, the direction of rotation is the opposite of that of standard pumps, and the chamber stack is turned up-side down. Consequently, the pumped liquid flows in the opposite direction.

Supplementary Grundfos pumps For pressures above 50 bar, we recommend Grundfos BM modules or Grundfos BME, BMET pumps. For further information about BM modules and BME, BMET pumps, see page 165.

CR, CRI, CRN, CRT,

5
Cavitation is often a problem in applications where pumps have to cope with the combination of high liquid temperatures, poor inlet pressure and/or high flow rate. Low-NPSH pumps eliminate the risk of cavitation and ensure a stable and reliable operation. The CR low-NPSH pump is a pump with a special first stage design that reduces the pumps NPSH value and prevents erosion and destruction of the pump, pipework and valves. For further information about NPSH and the calculation of NPSH-value, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. High-temperature applications The pumping of hot liquids demands much of pump parts, such as the shaft seal and rubber parts. To ensure a reliable and stable production, we offer CR pumps with an air-cooled top. A CR pump with an air-cooled top has a standard mechanical shaft seal handling liquid temperatures up to +180 C at 25 bar without external cooling. At the same time the pump delivers a high pressure. As the name implies, the pump is fitted with a special air-cooled shaft seal chamber generating the same insulation effects as that of a vacuum flask. Further documentation
Information about CR low-NPSH pumps CR pumps with air-cooled top Pumps with bearing flange CR pumps with under-/oversize motor Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 38 31 46 23 18-63 15 59 165

Fig. 2

CR pumps for hot-water applications

Reference applications Boiler feeding applications involving poor inlet/suction conditions cleaning and washing applications high-temperature applications.

Customised solutions Hot-water applications often expose pumps to a variety of extreme conditions, such as high temperatures, long operating hours, frequent starts/stops, pressure pulsing, poor inlet conditions and high inlet pressure. Such conditions may result in cavitation and/or cause increased wear of pump parts, for instance motor bearings and shaft seal, and thus reduce the pump life. To avoid breakdowns, we offer customised solutions designed to meet your needs! We provide solutions for applications involving special requirements: steady steam production poor inlet conditions high temperature, etc. Steady steam production To ensure a steady steam production and a constant water level in the boiler tank, we recommend speed-controlled pumps. Why speed-controlled pumps are recommended: The reaction to changes in the steam consumption is faster compared with mains-operated pumps. The water level in the boiler feed tank is kept stable. The installation costs are lower compared to systems with mains-operated pumps and valves.

Condensate Controller

10 bar +170 C
TM03 2615 4605

Boiler

Burner

Fig. 3

Boiler-feed application with speed-controlled pump

GR5228 - GR7767 - TM02 8470 4004

11

Applications

Hot-water applications

Applications involving poor inlet conditions

5
Applications involving temperature control
Applications
12

CR, CRI, CRN, CRT,

Pumping of high-temperature liquids The pumping of hot liquids demands much of pump parts, such as shaft seals and rubber parts. Examples of such liquids: water-based liquids up to +180 C at PN 25 thermal oils up to +240 C at PN 16. To ensure a reliable and stable production, we offer CR pumps with an air-cooled top and special rubber parts. A CR pump with an air-cooled top is a pump which can handle high temperatures and deliver a high pressure. The pump is fitted with a special air-cooled shaft seal chamber generating the same insulation effects as that of a vacuum flask. Pumping of high-viscous liquids In applications where high-viscous liquids are pumped, precautions must be taken to ensure that the motor of the pump is not overloaded, and that the pump performance is not reduced too much. The viscosity of a pumped liquid depends strongly on the liquid temperature. To ensure a stable and reliable operation, we offer CR pumps with oversize motors. Further documentation
Information about ATEX-approved pumps CR pumps with air-cooled top Pump rubber parts CR pumps with oversize motor Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 19 31 46 23 18-63 15 59 165

Fig. 4

CRE, CRIE, CRNE pumps with sensor

Reference applications Cooling systems: Electronic data processing laser equipment medical equipment industrial cooling and freezing processes, etc. Temperature-control systems: Casting and moulding tools oil processing, etc. Customised solutions To ensure a safe and reliable operation in applications involving temperature control, we offer customised solutions designed to meet your needs! We provide solutions for applications involving pumping of the following liquids: liquids at temperatures down to -40 C high-temperature liquids high-viscous liquids, etc. Pumping of liquids down to -40 C In applications where liquids are pumped at temperatures down to -40 C, it is crucial for a successful production that pump parts are of the right materials and dimensions. At such low temperatures, the selection of wrong materials and dimensions may cause deformation because of thermal expansion, and eventually stoppage of operation. For low-temperature liquids below -20 C, we recommend CRN pumps.

TM02 7397 3403

CR, CRI, CRN, CRT,

5
We recommend pumps with back-to-back seal arrangements for toxic, aggressive or flammable liquids. Pumps with back-to-back seal arrangements are connected to a pressure intensifier preventing leakage from the pump to the atmosphere side. MAGdrive pumps We recommend pumps with magnetic drive (MAGdrive) for toxic and hazardous liquids. The MAGdrive pump is a hermetically sealed pump. In the MAGdrive pump, the power from the motor is transmitted to the pump shaft by means of magnetic force instead of a traditional coupling. The motor shaft and the pump shaft are hermetically separated from each other. ATEX-approved pumps We recommend ATEX-approved pumps for potentially explosive atmospheres. Explosive atmospheres consist of air and combustible material such as gases, vapours, mists or dusts in which the explosion spreads after ignition. We offer ATEX-approved pumps with these classifications: 2G EExe II T3 2G EExd IIB T4 2G EExd IIC T4 2G EExde IIB T4 2G EExde IIC T4 EEx 2D T125 EEx 3D T125 . Electropolished pumps We recommend electropolished pumps for applications with strict requirements concerning corrosion and cleanability. We offer electropolished pumps in all CRN pump sizes. Further documentation
Information about CR pumps with back-to-back seal arrangement CR pumps with tandem seal arrangement Pumps with magnetic drive (MAGdrive) ATEX-approved pumps Customised pump parts Special installation requirements E-pump solutions WebCAPS see page 27 30 34 19 18-63 15 59 165

Fig. 5

CR pumps for aggressive/hazardous liquids

Reference applications Chemical industry pharmaceutical industry refineries petrochemical industry distilling plants paint industry mining.

Customised solutions In industries where pumping of dangerous and aggressive liquids is an integrated part of the daily production, safety is top priority. Leaking pumps pose a danger to the environment. To prevent breakdowns, we offer customised solutions designed to meet your needs! We provide solutions for the following liquids: aggressive and abrasive liquids toxic and hazardous liquids flammable liquids odorous liquids. To ensure a safe handling of the above liquids, we offer the following pumps: pumps with tandem seal arrangement and flushing pumps with back-to-back seal arrangement and pressure intensifier pumps with magnetic drive (MAGdrive) pumps with ATEX approval. Pumps with tandem seal arrangement Pumps with tandem seal arrangements connected to a flushing device are used for crystallising, hardening or sticky liquids. If the primary seal leaks, the leaking liquid will be flushed away by a flushing liquid.

GR5954 - GR7369 - GR5216

13

Applications

Aggressive/hazardous liquids

Pumps with back-to-back seal arrangement

5
Hygienic applications
TM02 1808 2001 - GR7375 - TM02 8470 4004

CR, CRI, CRN, CRT,

Cleanability In secondary hygienic applications, it is extremely important to clean the pumps sufficiently to prevent deposits from contaminating the pumped liquid. For secondary hygienic applications, we recommend CRN(E) pumps which have all pump parts in stainless steel. As the surface and properties of the metal is not affected by cleaning agents, stainless steel is the ideal solution. ATEX-approved pumps We recommend ATEX-approved pumps for potentially explosive atmospheres. Explosive atmospheres consist of air and combustible material such as gases, vapours, mists or dusts in which the explosion spreads after ignition. Further documentation
Information about Cleaned and dried CR pumps see page 37 37 38 19 18-63 15 59 165

Applications
14

Fig. 6

CR pumps for hygienic applications

CR pumps are not designed for the pumping of hygienic and sterile liquids, but their construction and the choice of materials make them an ideal solution for secondary processes in hygienic applications. Reference applications Pharmaceutical industries biotechnological industries electronics industries food and beverage industries process industries.

Electropolished CR pumps Stainless steel CRN pumps ATEX-approved pumps Customised pump parts Special installation requirements E-pump solutions WebCAPS

Customised solutions In hygienic industries, pumps must meet strict requirements on design, materials, surface quality, cleanability, etc. To ensure a hygienic and reliable production, we offer customised solutions specially designed to meet your requirements! We provide solutions for applications involving special requirements to hygienic design and cleanability. Hygienic design The surface quality of pump parts is of utmost importance - both for corrosion resistance and microbial adhesion and growth. To meet the strict hygienic requirements to material and surface quality in secondary hygienic processes, we offer electropolished stainless steel CRN pumps with the following surface quality:
Pump type CRN 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 Available. Cast stainless Stainless steel Surface steel parts (not cast) quality Ra 0.8 m

Supplementary Grundfos pumps If sanitary pumps with a hygienic design are required, we recommend the following Grundfos sanitary pump types: F&B-HYGIA Euro-HYGIA Contra Sipla. Most of the Grundfos sanitary pumps comply with the QHD, EHEDG and 3-A sanitary standards. For further information, see page 165.

Furthermore, we offer a wide variety of connections, such as TriClamp connections, specially designed for pharmaceutical, food and beverage industries. For further information about TriClamp connections, see page 49. We offer the following pumps: cleaned and dried pumps mechanically or electropolished pumps. Electropolished pumps have a higher corrosion resistance than non-polished pumps.

CR, CRI, CRN, CRT,

5
Belt-driven pumps are often selected in the following cases: non-electrically driven applications for instance air-, solar-, wind-, diesel- and pneumatically driven applications installations requiring an alternative supply, for instance firefighting systems and emergency pumps. The construction of belt-driven pumps is like that of electrically driven pumps, but belt-driven pumps have a pulley and belt connected to a combustion motor or other device. Pumps with alternative mounting For installations with limited access and space, we offer pumps with alternative mounting of pump parts such as terminal box and vent screw. Certificates, approvals and reports We offer customised pumps with a wide variety of certificates and approvals. Examples: Inspection certificate 3.1C - Lloyds Register of Shipping (LRS) - Det Norske Veritas (DNV) ATEX, VIK and UL approvals Duty-point verification report Vibration test report. Further documentation
Information about Horizontally mounted CR pumps Belt-driven CR pumps Stainless steel CRN pumps Pump parts designed to match your needs CR pumps with certificates E-pump solutions WebCAPS see page 39 43 38 18-63 54 59 165

Fig. 7

CR pumps for special installations

Reference applications Places with limited access and space ships mobile applications fire protection earthquake-prone areas applications in remote areas.

Customised solutions Due to safety, location and arrangement requirements some installations require pumps of another design than traditional vertical pumps. To meet special installation requirements, we offer customised solutions designed to meet your needs! We provide solutions for the following pump types: horizontally mounted pumps belt-driven pumps pumps with alternative mounting, etc. Horizontally mounted pumps Horizontally mounted pumps are often chosen in the following cases: installations with limited access and space, for instance cabinets and compact systems earthquake-prone areas mobile systems, for instance ships and vehicles. For installations with limited height, we recommend horizontally mounted pumps. For earthquake-prone areas, we recommend horizontally mounted pumps to lower the centre of gravity and thus minimise swings during an earthquake. See the example in fig. 8.

GR5886 - GR5379 - GR5887

Supplementary Grundfos pumps For installations with special requirements to a compact design, we recommend CH, CHI pumps or BM booster modules. For further information, see page 165.

Fig. 8

Vibrations of pumps in earthquake-prone areas

If the chamber stack and staybolts are stressed by repeated swings during an earthquake, they may break and cause stoppage of operation. For earthquake-prone areas and in mobile systems, we recommend CRN pumps, as stainless steel is more ductile than cast iron.

TM03 2645 4705

15

Applications

Special installation requirements

Belt-driven pumps

5
Special applications
GR7369 -TM02 8470 - TM02 1808

CR, CRI, CRN, CRT,

Pumping of liquids down to -40 C In applications with liquid temperatures down to -40 C, the material of shaft seal faces, the dimensions of the neck ring and other factors must meet high requirements. At such low temperatures, the selection of wrong materials and dimensions may cause deformation because of thermal expansion, and eventually stoppage of operation. For liquids below -20 C, we recommend CRN pumps. Deep-well pumping in small water supply systems Water is pumped from depths down to 90 metres. The system consists of a dry-mounted CR pump connected to a submerged ejector. Pumps operating under special conditions Installations at high altitudes (above 1000 metres) applications with low, high or fluctuating ambient temperatures the pumping of high-viscous/-density liquids. In such cases, the motor may be overloaded and an oversize motor may be required. Special requirements We offer customised pumps meeting special requirements as to approvals, voltage, frequency, etc. Further documentation
Information about CR pumps for cooling applications CR pumps for deep-well pumping CR pumps with under-/oversize motors Pump parts designed to match your needs Special installation requirements E-pump solutions CR pumps with certificates WebCAPS see page 36 45 23 18-63 15 59 54 165

Applications
16

Fig. 9

CRT, CRNE and CRN pumps

Reference applications Off-shore and maritime applications cooling applications deep-well pumping systems pumps operating under special conditions.

Customised solutions We offer customised solutions for a number of applications not mentioned on the previous pages. Examples: Off-shore and maritime applications pumping of liquids down to -40 C deep-well pumping in small water supply systems special conditions special requirements as to approvals, voltage, frequency. To ensure a stable and reliable operation, we offer customised solutions designed to meet your needs! Off-shore and maritime applications In off-shore and maritime applications, pumps must meet stringent requirements to reliability in connection with for instance cooling, firefighting, cleaning and desalination systems. Pumps are often installed in a corrosive environment. We offer customised pumps with a wide variety of 3.1C inspection certificates, such as Lloyds Register of Shipping (LRS) and Det Norske Veritas (DNV). For further information, see page 54. Furthermore, we offer customised pumps with a wide variety of materials, connections, enclosure classes, etc. For the pumping of seawater, we recommend CRT(E) pumps which have all pump parts in titanium. As its corrosion resistance is not affected by seawater, titanium is the ideal solution.

Supplementary Grundfos pumps If the suction head exceeds 90 metres, we recommend Grundfos SP and SQ submersible pumps. For further information about SP and SQ pumps, see page 165.

CR, CRI, CRN, CRT,

6
Accessories
Product number 96607921 96607922 96607923 -

6. Accessories
ATEX-approved dry-running protection
For environments, group II, category 2G, always use the ATEX-approved dry-running protection described below, or a similar product with ATEX approval. The link between ATEX groups, categories and zones is explained in the 1999/92/EC directive. Please note that this is a minimum directive. Some EEC countries may therefore have stricter local rules. The user or installer is always responsible for checking that the group and category of the pump correspond to the zone classification of the installation site. Components
Designation Ex marking Connection G 1/2 AISI316Ti G 1/2 AISI316Ti [C] 85 120 [V] 230 Terminals 4 Type

Fig. 11 ATEX-approved extension box

Flow sensor

II 2G Ex ib IIC T6

Amplifier for flow sensor

II (1) GD [Ex ia] IIC -

The extension box is designed for connection of intrinsically safe and/or non-intrinsically safe circuits in explosion-hazardous areas of category 2 (zone 1 and 21).

Extension box

Venting valve with connecting pipe

II2GEx e IIT6 II 2GEx ia IIC T6 II 2GEx e [ia] IIC T6

GKEI 100 97754528 GKI 60 97754527 GKE 60 97752524

Fig. 12 Venting valve with connecting pipe

TM05 1169 3511

The connecting pipe of this special venting valve allows the operator to deaerate the pump into a closed container. This accessory is ideal when pumping aggressive or hazardous liquids.
Designation Connection Type EPDM FKM FFKM FXM Product number 97773787 97775104 97775105 97775106

Fig. 10 ATEX-approved flow sensor and amplifier

Venting valve with connecting pipe

G 1/2

TM05 1160 0611

TM05 1120 0611

17

7
7. Motor
The Grundfos standard range of motors meets a wide variety of application demands. For special applications or operating conditions, we offer various customised solutions: a wide range of motor approvals motors with special voltage motors with anti-condensation heater motors with Harting 10-pin multiplug connection motors with built-in PTC sensor motors with built-in thermal switch undersize and oversize motors motors with alternative enclosure class, etc.

CR, CRI, CRN, CRT,

Motor
18

Tropicalised motors
A tropicalised motor does not contain paper, wood or similar materials containing wood pulp. Grundfos defines a tropicalised motor as a motor which fulfils the climate group "World-Wide" in DIN/IEC 721-2-1 and has the following characteristics: enamel covered windings double winding impregnation double winding insulation FPM V-ring terminal board made of polyester liquid sealing between frame and flange/end shield all outside screws made of stainless steel 30 m paint layer on aluminium stator housings 120 m paint layer on cast-iron stator housings heating element.

VIK-approved motors
We recommend VIK-approved motors for industrial climates where aggressive gasses and/or aggressive vapours, etc., are likely to occur. The VIK standard applies to three-phase mains-operated motors and three-phase motors connected to a frequency converter. We offer VIK-approved motors from 0.37 to 75 kW in accordance with the requirements of the German industrial standard, Verband der Industriellen Energieund Kraftwirtschaft. To comply with the standard, VIK-approved motors must meet these requirements: Group II, Category 2, version EEx e or EEx d, temperature class T3 in the ATEX directive. In case of doubt, consult the above standard or contact Grundfos. Enclosure class IP55 as a minimum. Protected against sucking. This phenomenon may occur when the pressure inside the motor is lower the atmospheric pressure. In such cases, moisture is sucked from the atmospheric side into the motor through bearing housings, etc. From 1.1 to 75 kW, all VIK-approved motors are IE2 high-efficiency motors. For further information about the VIK-standard, see www.vik.de or contact Grundfos.

cURus-, UR- and CSA-approved motors


We offer mains-operated motors with these approvals:
Approval cURus UR CSA Motor power - P2 [kW] 0.37 - 7.5 11 - 75 11 - 75

Other motor approvals


We offer a wide range of motor approvals: CCC C-tick GOST B TSU METI/JQA CB TSE SASO, etc.

CR, CRI, CRN, CRT,

7
TM01 6193 4202

Motor [kW]

Version (2G EExe II T3) (2G EExd IIB T4) (2D T125 ) (3D T125 )

We recommend ATEX-approved pumps for potentially explosive atmospheres. Explosive atmospheres consists of air and combustible material, such as gases, vapours, mists or dusts in which the explosion spreads after ignition. We offer explosion-proof or dust-ignition-proof motors in accordance with the directive 94/9/EC, the so-called ATEX directive. The ATEX-approved pumps can be used in areas (zones) classified according to the directive 1999/92/EC. In case of doubt, consult the above-mentioned directives or contact Grundfos. ATEX-approved pumps will be supplied with serial number, special installation and operating instructions and a nameplate showing the ATEX classification. A pump report is available on request. Scope of ATEX categories
Group I Category M2 Underground installations in mines liable to be endangered by explosive gasses or combustible dust. CR pumps available Motors available
1)

0.37 - 1.3 1.85 - 4.6 5.5 - 7.5 10 - 15 20 - 28 0.37 - 1.5 2.2 - 4 5.5 - 7.5 11 - 45 0.37 - 45 0.37 - 45

All explosion-proof motors have PTC sensors. For further information about PTC sensors, see page 22.

Special voltage
We offer pumps with the following voltages:
Frequency Mains-operated motor 3 3 3 3 3 3 3 3 3 3 3 3 3 x x x x x x x x x x x x x 220-240 /380-415 200-220/346-380 V 380-415 V 380-415 /660-690 200-230/346-400 V 208-230/460 V 220-255 /380-440 220-277 /380-480 220-277 /380-480 380-440 V 380-480 V 380-480 /660-690 575 YV YV Voltage

50 Hz

Pumps made of materials that do not create sparks and thus do not constitute any danger of explosion. CR, CRI, CRN None 1)

YV

Air-driven or hydraulically driven motors are not available from Grundfos.

60 Hz

YV YV YV

Group II Category 2 Installation areas liable to be endangered by explosive atmospheres. 1999/92/EC 1) CR pumps available Motors available Pumps intended for use in areas in which explosive atmospheres are likely to occur. G (gas) Zone 1 CR, CRI, CRN, CRT 2G EEx e II T3 2G EEx d II B T4 Category 3 Installation areas liable to be endangered by explosive atmospheres. 1999/92/EC 1) CR pumps available Motors available
1)

YV

Motor with integrated frequency converter 50/60 Hz 1 x 200-240 V 3 x 200-240 V 3 x 380-480 V

2)

D (dust) Zone 21 CR, CRI, CRN, CRT 2D 125 C

Note: Other voltages are available on request.

Pumps intended for use in areas in which explosive atmosphere only rarely occur. G (gas) Zone 2 CR, CRI, CRN, CRT 2G EEx e II T3 2G EEx d II B T4 D (dust) 1) Zone 22 CR, CRI, CRN, CRT 3D 125 C

Note: The link between groups, categories and zones is explained in the 1999/92/EC directive. Please note that this is a minimum directive. Some EEC countries may therefore have stricter local rules. The user or installer is always responsible for checking that the group and category of the pump correspond to the zone classification of the installation site. 2) For group II, category 2 G (zone 1), the pump must be protected against dry running. Use one of the following methods: An ATEX-approved dry-running protection. Always use this protection on pumps with MAGdrive or pumps with a single mechanical shaft seal. Pumps with double-seal system (back-to-back or tandem). The system for pressurising or flushing the double-seal system must be ATEX-approved.

19

Motor

ATEX-approved pumps

We offer the following ATEX-approved motors:

7
Motor with multiplug connection
Dimensions All dimensions are in mm.

CR, CRI, CRN, CRT,

129

167

Fig. 13 Mains-operated motor with Harting 10-pin multiplug

Fig. 16 Dimensions, 0.37 - 1.1 kW

Mains-operated motors fitted with a Harting 10-pin multiplug connection, HAN 10 ES, enable easy connection to the mains. Note: For Grundfos motors with integrated frequency converter up to 7.5 kW, we offer the solutions shown on page 20. The purpose of a multiplug connection is to make the electrical installation and service of the pump easier. The multiplug functions as a plug-and-pump device. The drawings below show the position of the multiplug on the mains-operated motor.
TM01 8713 0700 - TM02 8518 0304

192 230

Fig. 17 Dimensions, 1.5 - 7.5 kW

Plug connections

W2 U2

V2

U1

V1

W1

Fig. 18 Plug connection from motor

Fig. 14 Motor with multiplug connection

The multiplug connection is available for the following motor sizes:


Motor power P2 [kW] 0.37 - 7.5 0.37 - 7.5 Voltage [V], starting method 3 x 220-240 /380-415 YV 3 x 380-415 V

L1 1

L2 2

L3 3 4 5
TM01 8703 0700 TM01 8704 0700

Logo for multiplug

10

Fig. 19 Plug connection for star connection

L1 1
TM02 0470 0700

L2 2

L3 3 4 5

10

Fig. 15 Logo

Fig. 20 Plug connection for delta connection

Note: Fishplates for connections are located in the plug.

20

TM01 8702 0700

10

TM01 8714 0700

TM01 8716 0700

Gr7550

Motor

CR, CRI, CRN, CRT,

7
High humidity may cause condensation in the motor. Slow condensation occurs as a result of a decreasing ambient temperature; rapid condensation occurs as a result of shock cooling caused by direct sunlight followed by rain. We recommend always to use motors with anti-condensation heater in areas with ambient temperatures below 0 C. Note: Rapid condensation is not to be confused with the phenomenon which occurs when the pressure inside the motor is lower than the atmospheric pressure. In such cases, moisture is sucked from the atmosphere into the motor through bearings, housings etc. In applications with constant high humidity levels above 85 %, the drain holes in the drive-end flange must be open. This changes the enclosure class to IP44. If IP55 protection is required due to operation in dusty environments, we recommend to install a motor with anti-condensation heater. The figure below shows a typical circuit of a three-phase motor with anti-condensation heater.

To facilitate electrical installation and service of our three-phase CRE pumps up to 7.5 kW, all motor terminal boxes are equipped with a detachable cable inlet bar. When the cable inlet bar is removed, it is possible to disconnect all electrical connections. Figure 21 shows the location of the detachable cable inlet bar on the motor terminal box as well as plugs for mains connection, sensor and communication.

TM03 1964 3405 - TM03 1962 3405

Fig. 23 Three-phase motor with anti-condensation heater

Fig. 21 Location of the detachable cable inlet bar on the motor terminal box as well as plugs for mains connection, sensor and communication

Key
Symbol K M Designation Contactor Motor

Motor with anti-condensation heater

TM03 2440 4305

Note: Connect the anti-condensation heater to the supply voltage so that it is on when the motor is switched off. Motors from 0.37 to 75 kW are available with anti-condensation heater.
Motor size, 50/60 Hz [kW] 2-pole 0.37 - 1.1 1.5 - 3.0 4.0 - 5.5 7.5 - 22 30-37 45 - 55 75
1)

Power of heating unit [W] 1 x 24 V 38 2 x 38 55 92 109 1 x 115 V 1 x 190-250 V 23 31 38 2 x 38 55 92 109

4-pole 0.25 - 0.75 1.1 - 3.0 4.0 5.5 - 15 18.5 1) 1)

Fig. 22 Mains-operated motor with anti-condensation heater

In applications where condensation in the motor may occur, we recommend to install a motor with an anti-condensation heater on the stator coil ends. The heater keeps the motor temperature higher than the ambient temperature and prevents condensation.

15 and 18.5 kW 4-pole are oversize motors in the CR pump range.

TM03 4058 1406

21

Motor

Plug-and-pump solutions for CRE pumps

7
Motors with PTC sensors
Key
Symbol S1 K1 +T
TM02 7038 2403

CR, CRI, CRN, CRT,

Fig. 26 Thermal switch incorporated in winding

L1 L2 L3 N

3UN2 100-0 C A1 H1 H2 N T1 T2 A2 K
96 98 95

Built-in thermal switches protect the motor against rapid as well as steady overload. We offer three-phase mains-operated motors from 0.37 to 11 kW with built-in thermal switches. Note: Thermal switches must be connected to an external control circuit to protect the motor against steady overload. The thermal switches require no tripping unit. Protection according to IEC 60034-11: TP 211 (steady and rapid overload). As protection against seizure, the motor must be connected to a motor-protective circuit breaker. Thermal switches tolerate the following maximum loads:
Umax 250 VAC 1.5 A 5.0 A (locked-rotor and breaking current) IN Imax

S1

K1

K1

M 3

Fig. 25 Three-phase motor with PTC sensors

22

TM00 3965 1494

TM02 7042 2403

Motor

Designation On/off switch Contactor PTC sensor (thermistor) in motor Motor Tripping unit with automatic reset Amplifier Output relay LED Ready LED Tripped Connection for control voltage Connection for PTC sensor loop

M 3UN2 100-0 C N K H1 H2 A1, A2 T1, T2

Fig. 24 PTC sensor incorporated in winding

Built-in PTC sensors (thermistors) protect the motor against rapid as well as steady overload. We offer motors with temperature-controlled PTC sensors in the motor windings. Three-phase mains-operated motors from 3 kW and up have PTC sensors as standard. Note: Temperature-controlled PTC sensors must be connected to an external tripping or LiqTec unit connected to the control circuit. For further information about LiqTec, see page 48. Protection according to IEC 60034-11: TP 111 (steady overload only) TP 211 (steady and rapid overload). PTC sensors comply with DIN 44 082. Maximum voltage at the terminals, Umax = 2.5 VDC. All tripping units available for DIN 44 082 PTC sensors meet this requirement. The figure below shows a typical circuit of a three-phase motor with PTC sensors.

Motors with thermal switches

CR, CRI, CRN, CRT,

7
We recommend to use an oversize motor if operating conditions fall outside the operating conditions described in these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. We especially recommend oversize motors in these cases: The pump is installed at an altitude above 3500 m (MG IE3), 2875 m (Siemens IE3), and 1000 m (MG IE2). The ambient temperature exceeds +60 C (MG IE3), +55 C (Siemens IE3) or +40 C (MG IE2). The viscosity or density of the pumped liquid is higher than that of water. We offer the following oversize motors. Mains-operated motors
TM00 3964 1494

Figure 27 below shows a typical circuit of a three-phase motor with built-in bimetallic thermal switches.

Oversize motors (three-phase) 2-pole 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0 4-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5

Fig. 27 Three-phase motor with thermal switches

Key
Symbol S1 K1 t M MV Designation On/off switch Contactor Thermal switch in motor Motor Motor-protective circuit breaker

Motors with integrated frequency converter


Oversize motors (three-phase) 2-pole 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 4-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5

23

Motor

Oversize motors

7
Undersize motors
We recommend to use an undersize motor if operating conditions fall much inside the standard conditions described in these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. We especially recommend undersize motors in these cases: The viscosity or density is lower than that of water. The duty point of the pump is constant, and the flow rate is significantly lower than the maximum recommended flow rate. We offer the following undersize motors. Mains-operated motors
Undersize motors (three-phase) 2-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 4-pole 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5

CR, CRI, CRN, CRT,

Motor sizes available for pumps


2-pole
Undersize motor Pump type [kW] CR CR CR CR 1s - CR 5 10 - CR 20 32 - CR 90 120 - CR 150 0.37 0.37 1.5 7.5 [kW] 7.5 18.5 45 75 Oversize motor

Motor
24

4-pole
Undersize motor Pump type [kW] CR CR CR CR 1s - CR 5 10 - CR 20 32 - CR 90 120 - CR 150 0.25 0.25 1.5 1.5 [kW] 1.5 4.0 11 18.5 Oversize motor

Motors with integrated frequency converter


Undersize motors (three-phase) 2-pole 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 4-pole 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0

CR, CRI, CRN, CRT,

7
Motor
TM03 1711 2805

Alternative enclosure class (IP)


The motor enclosure class complies with IEC 60034-5. The enclosure class states the degrees of protection of the motor against ingress of solid objects and water. All motors comply with IP55 as standard. On request, we offer motors in accordance with IP54 and IP65.
IP class Description The motor is protected against the ingress of dust, i.e. harmful layers of dust. The motor is protected against water splashing from any direction. The motor is protected against the ingress of dust, i.e. harmful layers of dust. The motor is protected against water being projected by a nozzle from any direction. The motor is protected against the ingress of dust. The motor is protected against heavy seas or high-pressure water jets from any direction. The motor is completely dust-proof. The motor is protected against water being projected by a nozzle from any direction.

4-pole motors

IP54

Fig. 29 4-pole motor

IP55

IP56

IP65

We offer all CR pumps with 4-pole motors. 4-pole motors are often preferred in these cases: A low sound pressure level is required. Inlet conditions are poor. Beating of the liquid is not allowed. Performance curves and technical data of 4-pole CR pumps, see page 110 to 136 and 123 to 136. Electrical data of 4-pole CR pumps, see pages 160 and 161.

Alternative terminal box positions


The terminal box is in position 6 oclock as standard. The possible terminal box positions are shown below.

Motor efficiency classes


The new EN standard 60034-30:2009 defines the following efficiency classes of low-voltage three-phase asynchronous motors from 0.75 to 375 kW: IE1: standard efficiency IE2: high efficiency IE3: premium efficiency. IE = International Efficiency. Three-phase motors of CR pumps are 0.75 to 75 kW IE3 motors as standard. CR pumps with IE2 motors are available on request.

Position 6 oclock (standard)

Position 9 oclock

Position 12 oclock

Position 3 oclock

Fig. 28 Possible terminal box positions

TM03 3658 0606

Other motor makes


We also offer pumps with a motor of any make which can fulfil requirements such as flange dimensions bearing specifications pump shaft. Alternatively, Grundfos pumps can be supplied without a motor.

25

8
8. Shaft seals
Shaft seal arrangements
Depending on the application, CR pumps are available with these shaft seals: single seal arrangement double seal arrangement magnetic drive. CR(E), CRI(E), CRN(E) pumps are fitted with a cartridge shaft seal mounted in a single seal arrangement as standard: HQQE or HQQV (0.25 - 45 kW) HBQE or HBQV (55 - 75 kW). CRT(E) are fitted with one AUUE or AUUV O-ring seal as standard. In applications where the pumped liquid may harm the environment, double seal arrangements or magnetic-drive pumps are selected. To ensure reliability, these conditions must be considered when selecting a shaft seal: operating pressure type of pumped liquid liquid temperature.

CR, CRI, CRN, CRT,

Shaft seals
26

Shaft seal variants


Liquids or applications exceeding the range of normal operating conditions require special-purpose shaft seal solutions. In order to meet any specific requirements, we offer variants of seal face material and secondary seal material (rubber parts). The following tables apply to clean water and water containing glycol. Shaft seal and seal face variants
Shaft seal, seal face variant HQQx CR(E), CRI(E), CRN(E) HBQx *) HQBx HUUx HUBx AQQx DQQx Temperature [C] Min. -40 0 0 -40 0 -40 -40 Max. +120 +120 +120 +90 +120 +90 +90 Pressure rating [bar] 30 30 30 30 30 25 25

Pump type

CRT(E)

*) Only for CR, CRN 120 and 150, 55-75 kW.

Overview of shaft seals


The below table shows the shaft seals available.
Shaft seal As standard CR(E), CRI(E) and CRN(E) HQQE HQQV HQQE *) HQQV *) HUBE HUBV HUUE HUUV HUUK HUUF HUBF HUBK HQQK HQQF HQBE HQBV HQBK KUHE KUHV KUUV KUUE On request

For explanation of codes, shaft seal types and materials, see the type key on page 9, or see the data booklet "Shaft seals" which is available in WebCAPS.

HBQE *) HBQV *)

CRT(E) AUUK AQQE AQQV AQQK DQQE DQQV DQQK

AUUE AUUV

*) Only for CR, CRN 120 and 150, 55-75 kW.

Codes for shaft seals, see page 9.

CR, CRI, CRN, CRT,

8
We offer two double seal arrangements: back-to-back (OQQx) tandem (PQQx).

We recommend shaft seals with EPDM O-ring material for water and aqueous solutions. EPDM rubber is not resistant to mineral oils. Temperature range for rubber material: heat-resistant from -40 C to +150 C water-resistant up to +140 C. Shaft seals with FKM O-ring material (HxxV) We recommend shaft seals with FKM O-ring material for a wide range of temperatures and pumped liquids, such as acids, saline solutions, mineral oil, vegetable oil and most solvents. Temperature range for rubber material: heat-resistant from -20 C to +240 C (oil only) water-resistant up to +90 C. Shaft seals with FFKM O-ring material (HxxK) We recommend shaft seals with FFKM O-ring material for a wide range of pumped liquids, such as nitric acid, solvents, varnishes, paints and dyes. Temperature range for rubber material: heat-resistant from -20 C to +150 C water-resistant up to +150 C. Shaft seals with FXM O-ring material (HxxF) We recommend shaft seals with FXM O-ring material for high temperatures as well as for acid liquids and gasses within oil and gas extraction. Temperature range for rubber material: -10 C to +275 C. For short periods up to +300 C. Plug and sleeve O-rings made of FXM are available for the full range. For further information about O-ring materials, see the following data booklets available in WebCAPS.
Data booklet CR, CRI, CRN, CRE, CRIE, CRNE, 50 Hz CR, CRI, CRN, CRE, CRIE, CRNE, 60 Hz CRT, CRTE Shaft seals Publication number V7023751 96488672 V7149894 96519875

Back-to-back seal arrangement


Back-to-back seal arrangements consist of two Grundfos cartridge shaft seals, type O, fitted back-to-back in a separate seal chamber. We recommend this type of seal arrangement for handling these types of liquid: toxic, aggressive or flammable liquids abrasive or sticky liquids which would either wear out, damage or block a mechanical shaft seal. The back-to-back double seal protects the surrounding environment and the people working in the vicinity of the pump. It is specially designed for operating pressures up to 25 bar and +120 C with the aim of minimising the risk of leakage from the pump to the environment.

Fig. 30 CR 1s to 5 with back-to-back seal arrangement

Fig. 31 CR 10 to 20 with back-to-back seal arrangement

Fig. 32 CR 32 to 90 with back-to-back seal arrangement

TM04 4267 1609

TM04 4405 1609

TM04 4404 1609

27

Shaft seals

Shaft seals with EPDM O-ring material (HxxE)

Double seal arrangements

8
Shaft seals
TM04 4406 1609

CR, CRI, CRN, CRT,

Fig. 33 CR 120 and 150 with back-to-back seal arrangement

Key to figures 30, 31, 32 and 33


Fig. 34 CR pump with dosing pump
Pos. 1 2 3 Designation Seal chamber Shaft seals Pump

Key
Pos. 1 2 3 4 5 6 Designation Pump Pressure tank Dosing pump Pressure switch Manometer Reservoir with barrier liquid

The back-to-back seal arrangement is available for the following CR pumps:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Dimensions All dimensions are in mm.


Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45 CR, CRN 64 CR, CRN 90 CR, CRN 120, 150 Additional height of seal chamber 108 90 210 240 166 184 111

The setpoint of the barrier liquid pressure is set by means of the pressure switch (pos. 4). When the pressure drops below the setpoint, the dosing pump will start and thus maintain a higher pressure in the seal chamber (max. pressure 16 bar). Barrier liquid is supplied from a reservoir (pos. 6). One dosing pump can supply several pumps with back-to-back seal arrangements. Connections are all RG 1/2". Note: Connecting pipes/hoses are not included. Dimensions of back plate with components All dimensions are in mm.

Pressurising In back-to-back seal arrangements, the pressure in the seal chamber must be higher than the pump pressure to prevent the pumped liquid from leaking through the shaft seal to the environment. Note: The barrier liquid will seep through the lower (primary) shaft seal and be mixed with the pumped liquid. The right barrier liquid must therefore be used. The pressure in the seal chamber can be generated in three ways: by an existing pressure source by a dosing pump by a pressure intensifier. For further information about Grundfos back-to-back seal arrangements, see the data booklet "Shaft seals" which is available in WebCAPS. CR pump with dosing pump The example below shows a CR pump with a back-to-back seal arrangement. The barrier liquid is supplied and pressurised by a dosing pump.

Fig. 35 Dimensional sketch

28

TM03 4660 2406

TM03 3810 1106

CR, CRI, CRN, CRT,

8
Shaft seals
TM01 4459 0399

CR pump with pressure intensifier

Note: One pressure intensifier can only supply one pump. The pressure intensifier is fitted on the pump from factory. Maximum operating pressure: 25 bar. Dimensions All dimensions are in mm.

GR5954

Fig. 36 CR pump with pressure intensifier 8

Fig. 38 Dimensional sketch 6


Pump type a 297 330 342 349 349 355 355 b 108 90 210 240 166 184 111 c 128 140 155 164 164 170 170

CR, CRI, CRN 1, 3, 5 CR, CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45

3 2 1 7

CR, CRN 64 CR, CRN 90 CR, CRN 120, 150

Note: The dimension "b" is the additional height as compared to the standard pump.

Fig. 37 Components of pressure intensifier


Pos. 1 2 3 4 5 6 7 8 9 Designation Pressure intensifier Piston Diaphragm Non-return valve Relief valve Vent screw, Rp 1/8 Spring for piston Pressure gauge (barrier liquid) Pressure gauge (pumped liquid)

The seal chamber is primed with barrier liquid via a non-return valve (pos. 4) until the pressure gauge (pos. 8) reaches 1.5 to 2 bar. The spring (pos. 7) is now preloaded with the barrier liquid pressure. The pump is primed and vented. When the pump is started, the pump pressure + the pressure from the preloaded spring will result in a pressure 1.5 to 2 bar higher in the seal chamber.

TM03 8299 1007

29

8
Tandem seal arrangement
Tandem seal arrangements consist of two Grundfos cartridge shaft seals, type P, mounted tandem in a separate seal chamber. We recommend tandem seals for crystallising, hardening or sticky liquids. CR 1s, 1, 3, 5, 10, 15 and 20 Key
Pos. 1 2 3 Designation Seal chamber Shaft seals Pump

CR, CRI, CRN, CRT,

TM03 3657 0606

Fig. 40 CR 32 to 90 with tandem seal arrangement

CR 120 and 150

TM04 4164 1609

TM03 9158 3507

Fig. 42 Tandem seal arrangement with circulating flushing liquid

30

TM04 3217 2408

Shaft seals

The tandem type of seal is available for these CR pumps:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Dimensions All dimensions are in mm.


Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32, 45, 64, 90 CR, CRN 120, 150 Additional height of seal chamber 108 90 0 111

Fig. 39 CR 1s to 20 with tandem seal arrangement

CR 32, 45, 64 and 90

Flushing-liquid systems CR pumps with tandem seal arrangement must be equipped with a flushing-liquid system. Note: The pumped liquid will seep through the lower (primary) shaft seal and be mixed with the flushing liquid. Maximum liquid temperature: +120 C. The flushing-liquid flow rate should also be matched to the application (recommended flow rate 25-200 l/h). The pressure of the flushing liquid must always be lower than the pressure of the pumped liquid. Note: The flushing-liquid supply must never be connected directly to the public water supply system. Local regulations must be observed. For further information about Grundfos tandem seal arrangements, see the data booklet "Shaft seals" which is available in WebCAPS. The following figures show examples of flushing systems for tandem seal arrangements.

Minimum 1 metre

Fig. 41 CR 120 and 150 with tandem seal arrangement

CR, CRI, CRN, CRT,

8
CR pumps with an air-cooled top are used where the pumping of hot liquids is crucial for a successful production. A CR pump with an air-cooled top is a pump with a special air-cooled shaft seal chamber generating the same insulation effect as that of a vacuum flask. No external cooling is necessary; the ambient temperature is sufficient.

In figure 42, the flushing liquid circulates between an elevated tank and the pump by natural circulation. Heated flushing liquid rises from the seal chamber to the tank where it cools down. The cooled-down flushing liquid returns to the seal chamber. At high temperatures, the circulation of flushed liquid through the seal chamber cools the seal faces of the shaft seal and reduces noise.

TM03 3809 1106

Fig. 45 CR pump with an air-cooled top

Fig. 43 Tandem seal arrangement with flushing-liquid supply

In figure 43, the flushing liquid enters the seal chamber via a pipe from an elevated tank. No heat is dissipated from the system.

CR pumps with air-cooled top have a mechanical silicon carbide/silicon carbide/EPDM cartridge shaft seal, type HQQE, as standard. The pumps are able to handle liquid temperatures up to +180 C at max. PN 25. Note: If the pumped liquid is oil, the pumps can handle following liquid temperatures: CR 1s to 90: +240 C at max. PN 16. CR 120 and 150: +180 C at max. PN 16. The following rubber part variants are available for our air-cooled top solutions:
Liquid temperature [C] Water-based liquids 120-150 EPDM FXM/EPDM Rubber part material

TM03 3813 1106

120-180 Thermal oils 120-240

FKM

Fig. 44 Tandem seal arrangement with flushing liquid connected to a drain

In figure 44, the flushing liquid enters the seal chamber via a pipe from an elevated tank. In case of leakage, the pumped liquid is washed away to the drain by the flushing liquid.

Temperatures above +120 C normally result in a substantial reduction of seal life due to poor lubrication of the seal faces. As the temperature in the seal chamber does not exceed +120 C during operation, a standard Grundfos shaft seal can be used. An automatic air vent is required for venting the pump seal chamber. Note: For safety reasons, fit a pipe in order to lead away steam from the air vent to a drain. Local regulations must be observed.

GR5228

31

Shaft seals

CR with air-cooled top

8
CR 1s, 1, 3 and 5 CR 120 and 150

CR, CRI, CRN, CRT,

TM03 9159 3507

Fig. 46 CR 1s, 1, 3 and 5 with air-cooled top

Fig. 49 CR 120 and 150 with air-cooled top

CR 10, 15 and 20

Key
Pos. Designation Air chamber Liquid Air vent Shaft seal Cooling channel

1 2 3 4 5

Pump range The air-cooled top is available for these pump types:
TM03 9160 3507

Pump type CR(E) CRI(E) CRN(E)

CR pumps with air-cooled top 1s 1 3 5 10 15 20 32 45 64 90 120 150

Fig. 47 CR 10, 15 and 20 with air-cooled top

Available.

CR 32, 45, 64 and 90

Note: CRT(E) pumps are not available with air-cooled top. Bearing flanges for CR pumps with air-cooled top When pumping hot liquids, the pump requires a net positive inlet pressure according to the vapour pressure of the specific liquid. For water applications at 180 C, a bearing flange is incorporated in the following pump types.
50 Hz CRI, CRN 10-1 - 10-6 CRI, CRN 15-1 - 15-3 CRI, CRN 20-1 - 20-3 CR, CRN 32-1-1 - 32-4 CR, CRN 45-1-1 - 45-2 CR, CRN 64-1-1 - 64-2-2 CR, CRN 90-1-1 - 90-1
TM03 4060 1406

60 Hz CRI, CRN 10-1 - 10-5 CRI, CRN 15-1 - 15-2 CRI, CRN 20-1 CR, CRN 32-1 - 32-2 CR, CRN 45-1-1 - 45-1 CR, CRN 64-1-1

Fig. 48 CR 32, 45, 64 and 90 with air-cooled top

Note: A bearing flange is not available for motors below 3 kW. Some CR, CRN 32 pumps come with oversized motors.

32

TM04 4165 0909

Shaft seals

CR, CRI, CRN, CRT,

8
Horizontal CR pumps with air-cooled top

Air vent positions on CR pumps with air-cooled top The air vent of vertical CR pumps with air-cooled top is in line with the discharge port (12 oclock position) as standard. The air vent is mounted vertically (12 oclock position) on horizontal pumps. The possible air vent positions are shown below. Vertical CR pumps with air-cooled top

Fig. 52 Air vent positions on horizontal CR pumps with air-cooled top

Key to fig. 52
3 oclock 12 oclock Pump type CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45, 64 CR, CRN 90, 120, 150 X 308 324 391 398 404

TM03 3659 0606

6 oclock

Note: 75 kW motors are higher than distance x.

Fig. 50 Air vent positions on vertical CR pumps

Dimensions All dimensions are in mm.

Fig. 51 Air-cooled top


Pump type CRI, CRN 1s, 1, 3, 5 (< 3 kW) CRI, CRN 1s, 1, 3, 5 (3 - 7.5 kW) CRI, CRN 10, 15, 20 (< 4 kW) CRI, CRN 10, 15, 20 (4 - 7.5 kW) CRI, CRN 10, 15, 20 (11 - 18.5 kW) CR, CRN 32 CR, CRN 45, 64 CR, CRN 90 CR, CRN 120, 150 (11 - 45 kW) CR, CRN 120, 150 (55 - 75 kW) X 142 172 156 186 217 176 186 190 190 243

Additional pump height


Pump type CRI, CRN 1, 3, 5 CRI, CRN 10, 15, 20 CR, CRN 32 CR, CRN 45 CR, CRN 64 CR, CRN 90 CR, CRN 120, 150 Additional pump height 108 90 210 240 166 184 111

TM03 4082 1609

TM03 4084 1609

33

Shaft seals

8
Magnetic-drive pump (MAGdrive)
Grundfos CRN MAGdrive pumps operate according to a patented, magnetic-drive system that eliminates the need for shaft seals. The power from the motor is transmitted to the pump by magnetic force and not by a conventional coupling. Combined with a hermetically sealed liquid end, the pump is totally leak-free. As all axial forces are absorbed in the MAGdrive system, the pump incorporates a standard ICE or NEMA motor with keyway and deep-groove ball bearing. Applications

CR, CRI, CRN, CRT,

The MAGdrive solution is available for these pumps:


CRN pumps with magnetic drive Pump type 1s CRN(E) 1 3 5 10 15 20 32 * 45 * 64 * 90 * Pos. 1 2 3 Designation Motor stool MAGdrive Pump head Materials

Fig. 54 MAGdrive system

Available. * Available up to 22 kW.

Cast iron. Stainless steel on request Stainless steel (EN 1.4408)

As minimum, a soft starter is required for these motors: 2-pole motors: 18.5 and 22 kW. 4-pole motors: 1.1 kW and up. Features and benefits CRN MAGdrive offers the following special features and benefits: a hermetically sealed drive system for 100 % leak-free pump operation special choice of materials and design for low energy loss simple pump design for ease of service unique pump design for efficient cooling of magnet by means of the pumped liquid ATEX version available.

The configuration of the CRN MAGdrive pump is almost identical to that of the standard CRN pump. The following rubber parts solutions are available: EPDM FXM (Fluoraz) FFKM (Kalrez) FKM (Viton). Connections available for CRN MAGdrive pumps:
CRN Connection type 1s, 1, 3, 5, 10, 15, 20 DIN, ANSI, JIS flange PJE FlexiClamp, union, oval flange, TriClamp Available. 32, 45, 64, 90

34

TM03 9149 3407

Fig. 53 CRN MAGdrive pumps

GrA4445

Shaft seals

The CRN MAGdrive pump is suitable for wide selection of industrial applications such as: Aggressive or corrosive liquids Concentrated sulphuric acid, nitric acid, phosphoric acid, etc. Toxic liquids Trichloroethylene, chloroform, phenol, etc. Flammable liquids Petrol, jet fuels, LPG, alcohols, etc. Hardening/curing liquids Paint, glue, resins, etc. Crystallising liquids Glycol additives, naphthalene, sugar products, salts, etc. Refrigerants Ammonia, synthetic chemicals (CFC, HCFC, HCF), etc. Design

CR, CRI, CRN, CRT,

8
Maximum pressure: 25 bar. Temperature range: -40 C to +120 C. Viscosity range: 0.3 to 300 mPas. Technical data Motor range: 0.37 kW to 22 kW. Dimensions The height of the MAGdrive system typically makes the pump a little higher than a standard CRN pump. Some pump sizes have a larger motor than the standard range. For dimensions and weights for CRN MAGdrive pumps, see page 139 to 152. Note: When ordering a Grundfos MAGdrive, please state the data: liquid temperature [C] liquid viscosity [mPas] liquid density [kg/m3] frequency [Hz]. Above information is required for the selection of the correct MAGdrive/motor combination.
TM03 9141 3407

The magnetic field is generated by two magnets; the outer magnet is driven by the motor, and the inner magnet is connected to the pump. The two shafts are not connected.

Fig. 55 Sectional drawing of MAGdrive system


Pos. Designation 1 2 3 4 5 6 7 8 9 10 11 12 Outer drive Outer magnets Can Inner drive Inner magnets Rotating thrust bearing Stationary thrust bearing Radial bearing Upthrust bearing Drive/pump shaft Pump head O-ring Material 1.4301 NdFeB (neodymium) 1.4539 1.4401 NdFeB (neodymium) SiC Q1G (silicon carbide, carbon-filled) SiC Q1G (silicon carbide, carbon-filled) SiC (silicon carbide) Graflon (carbon-graphite-filled PTFE) CRN 1s-5 : 1.4401 CRN 10-20 : 1.4460 CRN 32-90 : 1.4462 1.4408 EPDM, FKM, FXM, FFKM

35

Shaft seals

Construction

Operating conditions

9
9. Pump
PN 25 and PN 40 pumps
We offer customised pump solutions for the following inlet pressures: CR 1 to CR 20: up to 25 bar. CR 32 to CR 150: up to 40 bar. Note: In applications with high inlet pressures, a bearing flange must be fitted. For further information, see the CR, CRN high-pressure data booklet (publication number V7174003).

CR, CRI, CRN, CRT,

TM03 4726 2506

Fig. 57 Insert for measurement of inlet pressure

The material of the insert is stainless steel (AISI 316).


Designation Rubber material EPDM FKM FFKM FXM EPDM FKM FFKM FXM EPDM FKM EPDM FKM Connection L [mm] Product number 96488082 96562250 96562251 96562252 96562253 96562254 96562255 96562256 96584117 96584119 96584121 96584122

CR 1s, 1, 3, 5

RG 1/4

57

CRI, CRN 1s, 1, 3, 5 Insert for measurement of inlet pressure

RG 1/4

51.5

CR 10, 15, 20 RG 1/4 62

CRI, CRN 10, 15, 20 RG 1/4 53

36

TM03 4091 1606

Pump

We offer these pump types with tappings:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Note: CR(E) and CRN(E) 32, 45, 64 and 90 have tappings for measurement of pump inlet pressure as standard.

Measurement of inlet pressure


As CR 1s to CR 20 pumps are not equipped with a connection for the measurement of pump inlet pressure, we offer customised pumps with a tapping for a pressure gauge or pressure sensor.

Pumping of liquids down to -40 C


We offer customised pumps for the pumping of liquids down to -40 C. The pumps have an oversize neck ring ensuring that impellers do not seize up as a result of thermal expansion. We offer the above solution for these pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Fig. 56 CR pump with pressure gauge

Available. Standard CRN 32, 45, 64 and 90 pumps with shaft seal type HQQE are suitable for liquid temperatures down to -40 C.

CR, CRI, CRN, CRT,

9
Certain processes, such as pumping of pure water in electronics industries, require pumps that do not contain carbon. To meet such requirements, we offer these 100 % carbon-free pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Cleaned and dried pumps Cleaned and dried pumps are used in applications involving strict demands to cleanliness and surface quality, such as low content of silicone. To meet these strict demands, we offer these cleaned dried pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available. Pumps with HQQx shaft seal are carbon-free as standard.

Available.

Prior to assembly, all pump parts are cleaned in 60 to 70 C water with a cleaning agent. All pump parts are then thoroughly rinsed in de-ionised water and air-dried. The pump is assembled without any use of silicone lubricants. Finally, the pump is packed in silicone-free plastic. Note: Silicone-free shaft seals are available as option. Cleaned and dried pumps are not performance tested. Electropolished pumps Electropolished pumps are often used in the pharmaceutical industry and in the food and beverage industry where materials and surface quality must meet strict requirements to hygiene or corrosion resistance. Electropolishing removes burrs as well as metallic and non-metallic inclusions, providing a smooth, clean and corrosion-resistant stainless steel surface. First all components are pickled in a mixture of nitric and hydrofluoric acid. Subsequently, the components are electropolished in a mixture of sulphuric and phosphoric acid. Finally, the components are passivated in nitric acid. All cast parts of CRN are polished mechanically before being electropolished. Note: The pump incorporates a standard shaft seal which has not been polished. To meet the strict hygienic requirements to material and surface quality, we offer electropolished stainless steel pumps with the following surface quality:
Pump type CRN 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 Available. Cast stainless Stainless-steel Surface steel parts (not cast) quality Ra 0.8 m

Corrosion protection
We offer corrosion protection in the form of painting and in several categories according to the specific requirements of the pump installation. The categories refer to area/environment, layer thickness and lifetime expectancy. The new DS/EN ISO standard 12944 divides the categories into three validity periods: Low: 2 to 5 years Medium: 5 to 15 years High: more than 15 years Corrosion protection will be according to the standard GS 704B0001. Alternative colouring We offer customised pumps in any NCS- or RAL-specified colour to suit your requirements! The used paint is water-based. Painted parts correspond to corrosion class III. All pump types and sizes are available with alternative colouring.

We offer these electropolished pumps:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

37

Pump

Surface treatment

Carbon-free pumps

9
CRN all-stainless steel pumps
We offer customised stainless-steel CRN pumps for maritime applications, very humid environments, etc.: pump with stainless-steel motor stool pump with stainless-steel base pump with stainless-steel flanges. We offer the above solutions for these pump types:
Pump type CR(E) CRI(E) CRN(E) *) *) 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT,

Pump range These pump types are available as low-NPSH pumps:


Pump type CR(E) CRI(E) CRN(E) Available. Maximum pressure Maximum liquid temperature
1)

Fig. 58 Sectional drawing of CR low-NPSH pump

Key
Pos. 1 2 Designation Special inlet part Special inlet impeller

38

TM03 4063 1406

Pump

CR low-NPSH pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

25 bar +120 C 1)

With air-cooled top, the maximum liquid temperature is +180 C.

Available. *)Only available with stainless steel base and flanges.

Note: The dimensions of customised stainless-steel CRN pumps do not differ from those of standard CRN pumps.

For further information about CR low-NPSH pumps, see pages 70 to 85. For information about sectional drawings, dimensions and weights, see pages 110 to 122.

CR low NPSH
Cavitation is often a problem in applications where pumps have to deal with the combination of high liquid temperatures, poor inlet pressure and/or high flow rate. For further information about NPSH and the calculation of NPSH value, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. Low-NPSH pumps are designed to eliminate the risk of cavitation and ensure a stable and reliable operation. The CR low-NPSH pump is a pump with a special first-stage design that reduces the pumps NPSH value and prevents erosion and destruction of the pump, pipework and valves. Thanks to the improved inlet design, low-NPSH pumps can handle more stress than conventional pumps without affecting the stability of operation. The CR low-NPSH pump reduces the excess pressure itself and does not require any additional tank to provide supplementary pressure. In boiler feed applications where many large tanks are gathered, a compact system is an advantage.

CR, CRI, CRN, CRT,

9
Pump
TM05 1537 2911 TM03 4642 3507

Horizontal inline pumps

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW) CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW)
B1

GR5379

Fig. 59 Horizontal CR pump


X

Horizontal pumps are used in applications for safety and/or space-saving reasons. In earthquake areas, horizontal pumps are more reliable than vertical pumps. In case of earthquake, the design and mounting of the pump will dampen the oscillations of the pump. In installations with limited access or space, we recommend horizontal pumps to improve installation and service. Pump range These Grundfos pumps are available for horizontal mounting:
Pump type CR(E) CRI(E) CRN(E) Horizontal CR pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

AB

2 x 14

AAA AA A

CR(E), CRN(E) 32, 45, 64, 90, 120, 150

Available.

CRT(E) 2, 4, 8 and 16 pumps are also available for horizontal mounting. The pumps are supplied with separate mounting plates for support of motor and pump. Dimensional drawings CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW) CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW)
B1

L C X

2 x 14

B B D

TM03 4641 3507

2 x 14

BB B

4 x 14

H
E

39

9
Dimensions All dimensions are in mm. CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 ( 4 kW), support for base plate and pump head
X Connections Motor [kW] 0.37-0.55 0.75-1.1 1.5-2.2 3-4 B C B1-118 B1-124 B1-140 B1-144 D 45 45 45 45 H L DIN Oval, PJE, FlexiClamp

CR, CRI, CRN, CRT,

Pump
40

138

140

50

105

80

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 5 (5.5 - 7.5 kW)


CR(E), CRI(E), CRN(E) 5 X Motor [kW] 5.5 7.5 Connections A 216 216 AA 326 326 AAA 366 366 AB 276 276 B 140 140 BB 180 180 C B1+119 B1+119 D 68 68 E 45 45 F 138 138 H 200 200 L DIN 50 50 105 Oval 80

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 4 kW), support for base plate and pump head
CR(E), CRI(E), CRN(E) 10 X Motor [kW] 0.37-0.55 0.75-1.1 1.5-2.2 3-4 Connections B C B1-125 B1-129 B1-144.5 B1-149.5 D 45 45 45 45 H L DIN, oval, PJE, FlexiClamp DIN, oval, PJE, FlexiClamp 15, 20

170

174

50

110

120

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR(E), CRI(E), CRN(E) 10, 15, 20 ( 5.5 kW), support for base plate and motor
CR(E), CRI(E), CRN(E) 10 X Connections Motor [kW] 5.5 7.5 11 15 18.5 A 216 216 254 254 254 AA 326 326 384 384 384 AAA 366 366 424 424 424 AB 276 276 334 334 334 B 140 140 210 210 254 BB 180 180 260 260 310 C B1+119 B1+119 B1+138 B1+138 B1+138 D 68 68 40 40 40 E 45 45 45 45 45 F 170 170 170 170 170 H 200 200 200 200 200 L 50 50 50 50 50 DIN, oval, PJE, DIN, oval, PJE, FlexiClamp FlexiClamp 15, 20

110

120

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR, CRI, CRN, CRT,

9
CR(E), CRN(E) 32 X Connections 45, 64, 90

Motor [kW] 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45

A 140 140 160 190 216 216 254 254 254 279 318 318 356

AA 320 320 340 370 395 395 440 455 455 485 540 540 580

AAA 380 380 400 430 455 455 500 515 515 545 600 600 640

AB 220 220 245 275 300 300 340 340 340 365 410 410 450

B 100 125 140 140 140 140 210 210 254 240 305 305 310

BB 165 165 180 180 180 180 275 266 310 310 365 365 370

C B1-261 B1-261 B1-254 B1-247 B1-228 B1-228 B1-209 B1-209 B1-209 B1-196 B1-184 B1-184 B1-168

D 200 200 190 178 158 158 130 130 130 110 90 90 65

E 400 400 400 400 400 400 400 400 400 400 400 400 400

L DIN DIN

290

60

212

177

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

CR, CRN 120, 150 (55-75 kW), support for base plate and motor
CR, CRN 120, 150 X Connections Motor [kW] 55 75 A 349 368 AA 419 AAA 409 479 BB 100 100 C B1-189 B1-167 D 40 10 E 400 400 H 290 290 L DIN 60 60 177 177

Note: For pump height (B1), see the CR(E), CRI(E), CRN(E) data booklet.

41

Pump

CR(E), CRN(E) 32, 45, 64, 90 ( 45 kW), support for base plate and motor

9
Horizontal end-suction pumps
Terminal box positions

CR, CRI, CRN, CRT,

IEC motor
TM05 1717 3511

Pump 1 type CRH CRIH CRNH

1s 3

10 15 20 32 45 64 90 120 150

Fig. 60 Horizontal end-suction pumps

CR(E)H, CRI(E)H, CRN(E)H 50/60 Hz


CRH, CRIH, CRHN pumps are horizontal end-suction pumps, typically mounted on base plates. The pumps are available in a complete 50 & 60 Hz range with both IEC or NEMA motors. Interchangeable ANSI solution The patented loose flange concept provides easy installation in ANSI, DIN or JIS standard pipework. Pump dimensions comply with the ANSI/ASME B73.1 standard and ensure interchangebility with traditional end-suction pumps with axial suction port and radial centre-line discharge port. This makes the CRH a high-efficiency solution designed for ANSI-specified applications. The back pull-out design enables service of most versions without removing the base from the pipework. CRH, CRIH, CRNH pumps are suitable for a variety of applications from pumping of potable water to pumping of chemicals. The pumps are therefore used in a wide variety of pumping systems where the performance and material of the pump meet specific demands. Energy efficiency To reduce loss and thus increase the pump efficiency, CRH, CRIH, CRNH pumps are available in an energy-optimised version with suction and discharge ports with a larger diameter than ANSI specifications.

Dimensions of CRH pumps with IEC motors, see section 17. Technical data. NEMA motor
Pump 1 type CRH CRNH 1s 3 5 10 15 20 32 45 64 90 120 150

Dimensions of CRH pumps with NEMA motors, see WebCAPS.

Variants
The same variants and accessories are available for the CRH, CRIH, CRNH pump range as for the standard CR pump range. The only difference between the CR horizontal end-suction pump and the CR inline pump is the base. However, the base for horizontal end-suction pumps is not available in titanium.

Construction

Fig. 62 Sectional drawing


Pos. 1 2 3 4 5 6 7 8 Designation Pump head Motor stool Shaft Impeller Chamber Sleeve O-ring for sleeve Base Pos. 9 10 11 12 13 14 15 16 Designation Neck ring Shaft seal Foot Flange ring Support bracket Sleeve flange Discharge port Bottom bearing ring

Fig. 61 CRH pump with axial suction port and radial discharge port

Max. pressure: 30 bar. Max. liquid temperature: 120 C (air-cooled top 180 C (oil 240 C)). Max. motor size: 45 kW.

42

TM05 1378 3511

TM05 1989 4111

TM05 1988 4111

Pump

CR, CRI, CRN, CRT,

9
Type III Pulley head 0.37 - 5.5 [kW] Type IV 7.5 - 18.5 [kW] Type II 1.5 - 7.5 [kW] Type I 11 - 45 [kW]

Pump type Pulley wheel diameter V-belts Pump speed [min-1]

CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20 10, 15, 20 112-135 2 Min. 200 Min. 3

CR, CRN 32, 45, 64, 90 Min. 160 Min. 2 Min. 200 Min. 3

GR5886 - GR5887

Max. 3000

Dimensional drawings CR, CRI, CRN 1s, 1, 3 and 5 (type III)

Fig. 63 Belt-driven CR pump

Belt-driven pumps are used in applications for space-saving reasons or where no electrical power is available. Belt-driven CR pumps are of the same construction as electrically driven CR pumps. They do, however, have a pulley for connection to for instance an internal combustion motor. Pump range These Grundfos pumps are available as belt-driven pumps:
Pump type CR CRI CRN Belt-driven CR pumps 1s 1 3 5 10 15 20
TM03 4137 1706

32

45

64

90

120

150

Available.

CRT 2, 4, 8 and 16 pumps are also available as belt-driven pumps. An additional bearing has been added on top of an existing bearing flange. The two bearings are fitted back to back. This bearing design makes it possible to withstand the extra radial forces caused by a pulley. A pulley can be attached to the end of the shaft. Note: The pulley is not supplied with the pump. By means of pulley belts, the pump can be driven by a motor mounted next to it rather than on top of it. The pump can be mounted horizontally or vertically by the extra support plates. The pulley head is positioned on the motor stool where the motor would normally be fitted. By means of the existing holes in the motor stool, the pulley head can be secured to the motor stool with bolts, washers and nuts. The pulley wheel is then attached to the shaft using an appropriate bush and key.

CR, CRI, CRN 10, 15 and 20 (type III)

TM03 4168 1706

43

Pump

Belt-driven pumps

For extended bearing life, we recommend these pulley wheel sizes:

9
CR, CRI, CRN 10, 15 and 20 (type IV)

CR, CRI, CRN, CRT,

CR, CRN 32, 45, 64 and 90 (type I)

TM03 4169 1706

CR, CRN 32, 45, 64 and 90 (type II)

44

TM03 4170 1706

TM03 4171 1706

Pump

CR, CRI, CRN, CRT,

9
Maximum system pressure: Maximum ambient temperature: Maximum liquid temperature: Minimum size of borehole Pump range These pumps are available with ejector:
Pump type CR CR deep-well pumps 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR(I) deep-well pumps are used for deep-well pumping in small water supply systems where water is pumped from depths (HD) down to 90 metres.

16 bar +40 C +40 C 3"

HD

CRI CRN Available.

Use of suction pipe


TM03 2954 4905

Fig. 64 System with CR(I) deep-well pump

If the well capacity is lower than the pump capacity, dry running of the pump can be prevented by fitting a suction pipe below the ejector. To enable this, the ejector strainer (E) is replaced with a special threaded nipple. Performance curves and technical data For information about the performance curves and technical data of CR deep-well pumps, see page 68 and 137. Ejectors Based on the performance curves on page 68, we offer the following ejectors:
Ejector type 45B 44B 29B 22B 20B 11B Product number 90230045 90230044 90230029 90230022 90230020 90230011

The pump system consists of a dry-installed CR(I) multistage centrifugal pump connected to a one-size submerged ejector via two pipes. We recommend to connect a pressure tank to the discharge side of the pump to maintain a suitable pressure at the tapping point.

A D

Contact Grundfos for further information about CR(I) ejector pumps.

C B
TM03 2953 4905

G F E

Fig. 65 Sectional drawing of ejector

Water is pumped through the pressure pipe (A) and the strainer (B) to the nozzle (C). The water passes the nozzle at high speed and flows into the diffuser (D). Via the strainer (E) and bottom valve (F), water which is to be pumped up is in connection with the chamber (G). From the chamber, it is pressed into the diffusor (D) by the water jet from the nozzle (C). There the two water flows mix, and the velocity is converted into pressure, driving the water up through the riser pipe (H) to the suction port of the pump.

45

Pump

CR(I) deep-well pumps

Technical data

9
Pump rubber parts
We offer pumps with a wide range of customised rubber materials such as EPDM, FKM, FFKM and FXM to suit your requirements.
Pump type CR, CR, CR, CR, CRI, CRN 1s, 1, 3, 5 CRI, CRN 10, 15, 20 CRN 32, 45, 64, 90 CRN 120, 150 EPDM Rubber material FKM FFKM 1) FXM

CR, CRI, CRN, CRT,

Bearing flange
To ensure long pump life and reliable operation, a bearing flange can be fitted between the motor and the pump head.

1s

10

15

20

32

45

64

90

120

150

CR(E) CRI(E) CRN(E)

Available.

Fig. 66 Bearing flange

Key

Empty chambers
We offer customised pumps with empty chambers designed to meet your specific duty point! CR pumps with a predefined number of chambers are selected from the standard range. See for instance the performance curves of CR 20-14 and CR 20-17 on page 7. In order to avoid the selection of a pump too large for your duty point, we offer customised pumps with empty chambers enabling an optimum match. We offer pumps with empty chambers for the following pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Pos. 1 2 3

Designation Motor Bearing flange Pump head

Available. Note: CRT(E) 2, 4, 8 and 16 are also available as customised pumps with empty chambers.

A bearing flange is an additional flange with an oversize ball bearing to absorb axial forces in both directions. The coupling is part of the bearing flange fitted to obtain optimum alignment. Note: The bearing flange requires a motor with keyway and ball bearings according to IEC 34 and NEMA. A bearing flange is used in two situations: 1. A standard motor with standard ball bearing is required. The bearing flange absorbs the hydraulic load from the pump, ensuring an acceptable motor bearing life. 2. The pump is to run at a higher inlet pressure than the maximum pressure recommended. Note: For motor sizes above 11 kW, the bearing flange is equipped with grease nipples and must be lubricated regularly. Please follow the instructions on the bearing flange. Pump range The following pump types are available with bearing flange:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Note: CRT(E) 2, 4, 8 and 16 are also available as customised pumps with bearing flange.

46

TM03 4062 1406

Pump

Available. 1) These pumps are fitted with FXM sleeve gaskets. All other rubber parts are of FFKM.

We offer customised rubber materials for these pump types:


Pump type

CR, CRI, CRN, CRT,

9
The following additional heights in mm must be added to the total height of the pump. CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20
Motor power IEC [kW]
TM02 7436 3403

CR, CRI, CRN 1s, 1, 3, 5 ( 7.5 kW) CR, CRI, CRN 10, 15, 20 ( 4 kW)

Additional height

0.37 - 0.55 0.75 - 1.1 1.5 - 4.0 5.5 - 7.5 11.0 - 18.5 NEMA [hp] 0.33 - 2.0 3.0 - 10 15 - 40
1) 2)

31 32 40 23 1) / 150 2) 150

CR, CRI, CRN 10, 15, 20 ( 5.5 kW)

40 45 135

CR, CRI, CRN 1s, 1, 3, 5 CR, CRI, CRN 10, 15, 20.

TM02 7437 3403

CR, CRN 32, 45, 64, 90


Motor power IEC [kW] 3.0 - 7.5 11.0 - 45 NEMA [hp] 3.0 - 10.0 15.0 - 60.0 22 17 23 20 Additional height

CR, CRN 32, 45, 64, 90 ( 7.5 kW)

TM01 4352 0199

CR, CRN 32, 45, 64, 90 (> 7.5 kW)

For information about the total height of a given CR pump, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CRT, CRTE CR, CRN high pressure. The above data booklets are available in WebCAPS. See page 165.

Support bearings
TM01 4353 0199

We offer customised pumps with support bearings of bronze for corrosive applications for these pump types:
Pump type CR(E) CRI(E) CRN(E) Available. 1s 1 3 5 10 15 20 32 45 64 90 120 150

47

Pump

Bearing flange for CR pumps

Dimensions

9
Bearing material
We offer pumps with a wide range of customised bearing materials such as bronze, tungsten carbide and carbon-filled PTFE to suit your requirements.
Pump size CR, CRN 1, 3, 5, 10, 15, 20 CR, CRN 32, 45, 64, 90 Bearing material Bronze/tungsten carbide EPDM/tungsten carbide Silicon carbide/tungsten carbide

CR, CRI, CRN, CRT,

Dry-running protection
LiqTec

We offer customised rubber parts for these pump types:


Pump type CR(E) CRI(E) CRN(E)

Fig. 67 LiqTec dry-running protection device


1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

Pump head positions


The pump head is mounted so that the air vent screw is in line with the discharge port as standard. The pump head can be mounted in three other positions in steps of 90 . Note: The air vent of horizontal pumps must always point upwards.

Customised nameplate
We offer additional customised nameplates attached to the pump: A nameplate supplied by you. A Grundfos nameplate customised in terms of a specific duty point. A Grundfos nameplate with a tag number. Note: A Grundfos standard nameplate is always fitted on the pump.

The Grundfos LiqTec immediately cuts off the pilot current to the motor protection relay in these cases: There is no liquid in the pump. The liquid temperature exceeds +130 5 C. The sensor, sensor cable, electronic unit or power supply fails. When connected to the PTC sensors in the motor, the LiqTec also protects the motor against overheating. The sensor is easily inserted through the 1/2" connection in the pump head close to the shaft seal. It can, however, also be used externally. The LiqTec sends a heat impulse through the sensor, measuring the temperature of the sensor. Liquid in the pump cools the sensor as well as the shaft seal and other pump parts. If there is no liquid present, the LiqTec detects a high temperature in the sensor and cuts out the pump immediately to prevent damage. The LiqTec also prevents excessive liquid temperatures from damaging the pump. If the LiqTec senses a liquid temperature above +130 C, it cuts out the pump immediately. The LiqTec is a fail-safe device, meaning that the pump stops as soon as the sensor detects an error on the sensor cable or the electronics, or if the power supply of the control unit is switched off. Restarting of the pump can be automatic or manual when the sensor detects liquid in the pump again. Remote restarting is possible via a digital input. The electronic control unit can also be connected to the PTC sensor measuring the motor temperature. In case of overheating of the motor, the system cuts out the pump.

48

GR9415

Pump

CR, CRI, CRN, CRT,

9
116 x 90 mm. The LiqTec can be mounted on a DIN rail in a control cabinet.

L1 L2 L3 N Sensor

Technical data
K1

Supply voltage
T+

1 x 80-130 V or 1 x 200-240 V 5W 40 bar -20 C/120 C 50 C 99 % IPX0 Any water-based liquid handled by Grundfos pumps 5 m 1)

Power consumption

T+

M
3

Max. pressure Min./max. liquid temperature Max. ambient temperature Humidity Enclosure class Pumped liquid Cable length
1)

External restart

T+

Brown/Black Blue White

15-metres cable is available on request.

Connections
TM03 0112 4004

CR pumps with TriClamp connection A base with TriClamp connection is of hygienic design with a sanitary coupling for use in the pharmaceutical and food and beverage industry. A set consists of one clamping ring, one gasket and one pipe stub. The connection is in accordance with EN/DIN 32676. Dimensions All dimensions are in mm.

K1

Fig. 68 LiqTec connected to a standard motor


L1 L2 L3 N

Sensor

T+

MGE
3

50. 5

T+

External restart Brown/Black Blue White

4 x 13
TM03 4648 3507

T+

50

22

100 150 162

32 180 210

Fig. 70 TriClamp connection for CRI, CRN 1s, 1, 3 and 5

202 64

TM04 4472 1309

200

215 248

Terminals in MGE motor


2 3 9

CRI, 10: 10 80 80 on CRN CRI, CRN CRI, 15, 15 20: 9020 90 on CRN CRI, CRN and

Fig. 69 LiqTec connected to an MGE motor

Fig. 71 TriClamp connection for CRI, CRN 10, 15 and 20

TM03 4649 2406

130

26

4 x 13

50

49

Pump

Figures 68 and 69 show installation examples.

Dimensions

9
Pump
Pump type CRI(E), CRN(E) 1s, 1, 3, 5 CRI(E), CRN(E) 10, 15, 20 Nominal diameter 38.0 32.0 51.0 50.0 Connection Pump type CRI(E), CRN(E) 1, 3, 5
GR5840

CR, CRI, CRN, CRT,

Clamping ring
TM03 4645 2406

Port
TM03 4646 2406

Gasket
TM03 4647 2406

A 92.0 102.0 104.4 123.0

B 59.5 60.0 74.0 75.0

B 50.5

C 35.6 32.0 48.6 50.0

D 38.6 36.0 51.6 54.0

A 35.3 32.2 48.0 50.2

B 50.5 64.0

21.5

64.0 65.0

The clamping ring is made of stainless steel EN/DIN 1.4301/AISI 304. The port is made of stainless steel EN/DIN 1.4401/AISI 316. The gasket is made of PTFE or EPDM.
Pipework connection DN 32 Stainless steel CRI(E), CRN(E) 10, 15, 20 DN 50 Connection material Gaskets PTFE EPDM PTFE EPDM Pressure [bar] 16 50 16 50 Coupling sets required 2 2 2 2 2 2 Product number 96515375 96515374 97549395 96515377 96515376 97549397

We offer TriClamp connections for these pump types:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

50

CR, CRI, CRN, CRT,

9
Pump
Gaskets EPDM FKM EPDM FKM Pressure [bar] Coupling sets required 2 2 2 2 Product number 96551545 96551547 96551549 96551570 16

CR pumps with connection to EN/DIN 11851 A base with connections according to EN/DIN 11851 is of hygienic design for use in dairies and in the food and beverage industry. A set consists of one pipe stub with external thread designed for a flexiClamp base with union connection. Dimensions All dimensions are in mm.
M10 x 40 22 4 x 13
TM03 4682 2506

50

100 150 321

75 180 210

Fig. 72 Connection to EN/DIN 11851 for CRI, CRN 1s, 1, 3 and 5

M10 x 40
26

4 x 13

CRI, 10: 80 80 onCRN CRI, CRN 10 CRI, 15, 20: 90 20 90 onCRN CRI, CRN 15 and

Fig. 73 Connection to EN/DIN 11851 for CRI, CRN 10, 15 and 20


Pump type CRI(E), CRN(E) 1, 3, 5 CRI(E), CRN(E) 10, 15, 20 Pipework connection DN 32 Stainless steel DN 50 Connection material

We offer the above connections for these pump types:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available.

TM03 4683 2506

130 200 394

100 215 248

51

9
CR pump with PJE coupling A base with PJE couplings is designed for use in a wide range of industrial applications. A set consists of two coupling halves, one gasket, one coupling liner for welding and bolts and nuts. Dimensions All dimensions are in mm.
88.9

CR, CRI, CRN, CRT,

105

30

170 226 320

240 298

Fig. 74 PJE coupling for CRN 32


114.3

4x 14
140 45
TM03 4720 2506
4x 14
4x 14

190 251 365

266 331

Fig. 75 PJE coupling for CRN 45

114.3

45

190 251 365

266 331

Fig. 76 PJE coupling for CRN 64

114.3

140

45

199 261 380

280 348

Fig. 77 PJE coupling for CRN 90

Fig. 78 PJE coupling for CRN 120 and 150

52

TM04 4558 1609

TM03 4722 2506

TM03 4721 2506

140

TM03 4719 2506

Pump

4x 14

CR, CRI, CRN, CRT,

9
Designed for pump type CRN 32 Rubber parts NBR seal 3" Product number 00ID7664

Part
TM00 3712 0894

Designation

Victaulic type 77 coupling 3": 89 4": 114

CRN 45, 64, 90, 120, 150

NBR seal 4"

96415463

TM00 3709 0894

CRN 32 Victaulic coupling liner for welding CRN 45, 64, 90, 120, 150

N version 3"

00150574

N version 4"

96416743

We offer PJE couplings for these pump types:


Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Customised connections We offer a wide range of customised connections for these pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Available. Note: PJE connections are available on CRI, CRN, 1s, 1, 3, 5, 10, 15 and 20 pumps as standard. CR pumps with ANSI or JIS connection We offer pumps with ANSI or JIS flanges for these pump types:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

Contact Grundfos for further information about customised connections. We also offer these connections: oval flanges (BSP) DIN flanges PJE couplings (Victaulic) for CRN(E) clamp couplings (L-couplings) unions (+GF+). For further information about connections, see these data booklets: CR, CRI, CRN, CRE, CRIE, CRNE CR, CRN high pressure CRT, CRTE. All data booklets are available in WebCAPS. See page 165.

Available. Note: ANSI and JIS connections are available on CRI, CRN, 1s, 1, 3, 5, 10, 15 and 20 pumps as standard. Technical data
Connection ANSI JIS Max. rated pressure Class 300 30 K

Note: CR(E), CRI(E), CRN(E) 1s, 1, 3, 5 and 10 pumps are available with flanges that meet the requirements of both DIN, ANSI and JIS as standard. The dimensions of pumps with DIN, ANSI or JIS flanges are the same, apart from the flange bolt holes.

53

Pump

10
10. Certificates
CR pumps with certificates
We offer certificates for a number of applications requiring documentation on the pump quality. Examples: pharmaceutical industries maritime and offshore applications potentially explosive environments energy and power suppliers. Note: The certificates must be ordered with the pump. These pumps are available with certificates:
Pump type CR(E) CRI(E) CRN(E) 1s 1 3 5 10 15 20 32 45 64 90 120 150

CR, CRI, CRN, CRT,

Certificates
54

Available.

Note: Certified and approved CRT(E) 2, 4, 8 and 16 pumps are also available. Certificates
Certificate Certificate of compliance with the order Test certificate. Non-specific inspection and testing Inspection certificate 3.1 Description According to EN 10204, 2.1. Grundfos document certifying that the pump supplied is in compliance with the order specifications. According to EN 10204, 2.2. Certificate with inspection and test results of a non-specific pump. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Grundfos document certifying that the pump supplied is in compliance with the order specifications. Inspection and test results are mentioned in the certificate. Certificate from the surveyor is included. We offer the following inspection certificates: Lloyds Register of Shipping (LRS) Det Norske Veritas (DNV) Germanischer Lloyd (GL) Bureau Veritas (BV) American Bureau of Shipping (ABS) Registro Italiano Navale Agenture (RINA) China Classification Society (CCS) Russian maritime register of Shipping (RS) Biro Klassifikasio Indonesia (BKI) United States Coast Guard (USCG) Nippon Kaiji Koykai (NKK) Certifies that the main components of the specific pump are manufactured by Grundfos, and that the pump has been QH-tested, inspected and conforms to the full requirements of the appropriate catalogues, drawings and specifications. Certifies the material used for the main components of the specific pump. Certifies the material used for the main components of the specific pump. A material certificate, EN 10204, 3.1, will be supplied for each main component. Certifies a test point specified by the customer. Issued according to ISO 9906 concerning "Duty point verification". Shows the measured roughness of the cast pump base of the specific pump. The report indicates the values measured at the base inlet and outlet according to ISO 1302. Vibration report indicating the values measured during the performance test of the specific pump according to ISO 10816. Shows the performance test of the specific motor, including power output, current, temperature, stator windings resistance and insulation test. Confirms that the specific pump has been cleaned and dried, and how it was done. Confirms that the specific pump has been electropolished. The maximum surface roughness is specified in the report. Confirms that the specific pump is ATEX-approved according to the EU directive 94/9/EC, the "ATEX directive".

Inspection certificate

Standard test report Material specification report Material specification report with certificate from raw material supplier Duty-point verification report Surface-roughness Vibration report Motor test report Cleaned and dried pump Electropolished pump ATEX-approved pump

See examples of the certificates on pages 55 to 58. Note: Other certificates are available on request.

CR, CRI, CRN, CRT,

10
Test certificate

Certificate of compliance with the order

Certificate of compliance with the order


EN 10204 2.1

Test certificate Non-specific inspection and testing


EN 10204 2.2

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type

Customer name Customer order no. Customer TAG no. GRUNDFOS order no.

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

Pump Pump type Motor make Flow Head Power P2 Voltage Frequency Full load current Motor speed

Part number P ar t num b e r m3/h m kW V Hz A min -1

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and / or specifications relative thereto.

TM03 4165 1706

Date: Signature: Name: Dept.:


Part no. 96 50 78 95/1001002

Date: Signature: Name: Dept.:


Part no 96 50 78 96/1001002

Inspection certificate 3.1

Inspection certificate

Inspection certificate.
EN 10204 3.1
Manufactured by GRUNDFOS order no. GRUNDFOS DUT id. Customer order no. Customer name and address Shipyard / factory Ship / new building Customer TAG no. Classifying society Pump Pump type Part number Serial no. Flow rate (m3/h) Head (m) Max. ope. P/t (bar / C) Din / W. - No. Base/Pump head cover Impeller/guidevanes Shaft/sleeve Customers requirements Flow rate (m3/h) Test result ref. requirements Q(m3/h) H(m) Hydrostatic test
-1

Inspection certificate.
Russian Maritime Register of Shipping

GRUNDFOS authorized department Motor Make Part number Serial No. P2 (kW) Voltage (V) Current (A) n(min-1) Frequency (Hz) Insulation class Power factor

Manufactured by GRUNDFOS order no. GRUNDFOS DUT id. Customer order no. Customer name and address Shipyard / factory Ship / new building Customer TAG no. Classifying society Pump Pump type Part number Serial no. Flow rate (m3/h) Head (m) Max. ope. P/t (bar / C) Service Medium

Russian Maritime Register of Shipping ( RS ) Motor Make Part number Serial No. P2 (kW) Voltage (V) Current (A) n(min-1) Frequency (Hz) Insulation class Power factor

Din / W. - No. Base/Pump head cover Impeller/guidevanes Shaft/sleeve Customers requirements Flow rate (m3/h) Test result ref. requirements Q(m3/h) H(m) Hydrostatic test The pump has been marked
-1

Head (m)

n(min )

I(A)

P1(kW)

Head (m)

Bar no leaks or deformation observed

n(min )

I(A)

P1(kW)

Bar no leaks or deformation observed

TM03 4162 3607

Date: Signature: Name: Dept.:


Part no. 96 50 78 97/1014142

Date: Signature: Name: Dept.:


Part no. 96 50 79 25/1014142

TM03 4156 3607

GRUNDFOS

Surveyor signature: Tested date:

GRUNDFOS

TM03 4163 1706

GRUNDFOS

GRUNDFOS

55

Certificates

Examples of certificates

10
Certificates
Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type GRUNDFOS DUT id. Part number We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto. The attached test result is from the above mentioned pump.

CR, CRI, CRN, CRT,

Standard test report

Material specification report

Standard test report


Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

Material specification report.

Pump Pump head Pump head cover Shaft Impeller Chamber Outer sleeve Base

Materials

DIN W.-Nr.

AISI / ASTM

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

TM03 4143 1706

Date: Signature: Name: Dept.:


Part no. 96 50 79 30 P01 /A72775

Date: Signature: Name: Dept.:


Part no 96 50 79 28/A72775

Material specification report with certificate from raw material supplier

Duty point verification report

Material specification report with EN10204 3.1 material certificate from raw material supplier

Duty point verification report

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. Product type GRUNDFOS DUT id. Part number We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured by GRUNDFOS, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

Pump Pump head Pump head cover Shaft Impeller Chamber Outer sleeve Base

Raw materiel no.

Supplier certificate no.

We the undersigned hereby guarantee and certify that the materials and/or parts for the above mentioned product were manufactured, tested, inspected, and conform to the full requirements of the appropriate catalogues, drawings and/or specifications relative thereto.

TM03 4149 3607

Date: Signature: Name: Dept.:


Part no 96 50 79 29/A72775

Date: Signature: Name: Dept.:


Part no. 96 53 96 99 /A72775

56

TM03 4148 1706

GRUNDFOS

GRUNDFOS

TM03 4150 1706

GRUNDFOS

GRUNDFOS

CR, CRI, CRN, CRT,

10
Vibration report

Surface-roughness

Vibration report
Surface roughness
According to ISO 1302 Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number CRN base part number The surface roughness is measured as the maximum roughness of the CRN inlet and outlet surface.

According to ISO 10816 Customer name Customer order no. Customer TAG no. GRUNDFOS order no. GRUNDFOS DUT id. Measured object Pump type P2 (kW) Number of poles Test conditions The pump is floormounted on vibration absorbers. Remarks

Part number Frequency (Hz) Serial no.

Voltage (V) Frequency: (Hz) Flow (m/h) Head (m) For vibration velocity measurement positions, see figure.

Result of measurement:
Pos RMS vibration velocity (mm/s)

Typical zone boundary limits 1 2 3 4 5 6 7 8 9


RMS vibration Class I Class II velocity (mm/s) 0.28 A 0.45 A 0.71 1.12 B 1.8 B 2.8 C 4.5 C 7.1 11.2 D 18 D 28 45 The machine classifications are as follows: Class I: Individual parts of engines and machines, integrally connected to the complete machine in its normal operating condition. (Production electrical motors of up to 15 kW are typical examples of machines in this category.) Class II: Medium-sized machines (typically electrical motors with 15 kW to 75 kW output) without special foundations, rigidly mounted engines or machines (up to 300 kW) on special foundations.

Surface Treatment None E lec t r o-p ol is h ed

Mea sure d val u es A R max RA RZ Me a s ur ed v a l ue s B R max RA RZ

[m] [m] [m]

[m] [m] [m]

Roughness value RA [m] 50 25 1 2. 5 6. 3 3.2 1.6 0.8 0.4 0 .2 0.1 0 . 05 0 . 0 25

Roughness degree N 12 N 11 N 10 N9 N8 N7 N6 N5 N4 N3 N2 N1

TM03 4147 3607

GRUNDFOS Date:
Signature: Name: Dept.:
Part no 96 50 79 31/A72775

Date: Signature: Name: Dept.:

26-Apr-06

Part no 96 50 79 32/A72775

Motor test report

Cleaned and dried pump

Motor test report

Cleaned and dried pump

Customer name Customer order no. Customer Tag no. GRUNDFOS order no. GRUNDFOS DUT id. Part number Motor no. Motor serie no. We the undersigned hereby guarantee and certify that the above motor has been tested. The performance of the motor can be seen in the motor test report on the next page.

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the specifications mentioned in the CR, CRI, CRN Custom-built pumps data booklet. This means that prior to assembly, pump components are washed in pure, hot soap water, rinsed in deionized water and dried. The pump is wrapped in a plastic bag before being packed. The pump has not been performance-tested.

TM03 4146 1706

Date: Signature: Name: Dept.:


Part no. 96 50 79 33 /A72775

Signature: Name: Dept.:


Part no 96 50 79 34/A72775

TM03 4145 1706

GRUNDFOS

GRUNDFOS Date:

TM03 4167 1706

GRUNDFOS

57

Certificates

10
Certificates
Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code Grundfos hereby conforms that the pump mentioned above is manufactured according to the specifications mention in the CR, CRI, CRN Custom-built pumps data booklet. This means that prior to asembly, pump components are electro-polished in a mixture of sulphuric acid and phosphoric acid. Finally the components are passivated in nitric acid. The CRN1s, 1, 3, 5, 10, 15, and 20 casted parts are all mechanically polished before being electropolished. The pump will then optain following surface roughness; ________________________________________________________________________ Pump type Stainless steel Surface plate and other roughness non casted parts ( m ) ________________________________________________________________________ CRN1s, 1, 3, 5 * * equal to or below 0,8 _______________________________________________________________________ CRN10, 15, 20 * * equal to or below 0,8 ________________________________________________________________________ CRN32, 45, 64, 90 * * between 10 15 equal to or below 0,8 GRUNDFOS Date: Signature: Name: Dept.:
Part no 96 50 79 35/A72775

CR, CRI, CRN, CRT,

Electropolished pump

ATEX-approved pump

Electro-polished pump

ATEX-approved pump

Customer name Customer order no. Customer TAG no. GRUNDFOS order no. Pump type GRUNDFOS DUT id. Part number Production code Pump serial no. Motor serial no. ATEX approval of pump Technical file no.

96499604

GRUNDFOS hereby confirms that the pump mentioned above is manufactured according the ATEX directive. This means the pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as mentioned in the ATEX Supplement to installation and operating instructions supplied with the pump.

Stainless steel casted parts

TM03 4144 1706

Signature: Name: Dept.:


Part no 96 51 22 40/A72775

58

TM03 4166 1706

GRUNDFOS Date:

CR, CRI, CRN, CRT,

11
CRE pump solutions
TM02 9032 1504 TM03 8612 2007

11. CRE pump solutions


Control panel

GR9033

Extended functional module (MGE I/O) Bus communication module (GENI/RS485)

Fig. 79 Motors for CRE, CRIE, CRNE, CRTE pumps

Besides continuously variable performance, CRE, CRIE, CRNE, CRTE pumps offer a number of advantages depending on the hardware and software combinations of the motor. We offer the following CRE pump solutions: CRE pump with extended functional module customised CRE pump solutions. CRE pumps are not dependent on the frequency of the supply voltage and are designed for operation at frequencies between 750 min-1 and 6000 min-1. This offers a number of advantages: compact pump higher performance in relation to physical size larger dynamic range less noise at reduced speed more gentle handling of the pumped liquid at reduced speed. The speed may be chosen freely, taking into consideration the maximum motor load and the hydraulic properties of the pump. Pumps can be delivered with oversize or undersize motors depending on load profile. Ball bearing configuration can also be altered to fit load and demands.

Terminal box including basic frequency converter and basic controller

Fig. 80 Hardware combination of a standard CRE pump

Figure 81 shows the terminal box of the motor containing a basic controller, an extended functional module and a GENIbus communication module.
Group 2 Group 3

NC C NO

L1 L2 L3

CRE pump with extended functional module


CRE pumps with extended functional module enable the control of more than one parameter, such as pressure, differential pressure, temperature, differential temperature or flow rate. CRE, CRIE, CRNE, CRTE pumps are equipped with these parts as standard: a control panel on the terminal box front. a basic controller with one digital input for start/stop, one analog setpoint input, etc. a functional module with three digital inputs, one analog sensor input, one analog sensor output and 24 V supply. a GENIbus communication module. See also page 61. Note: If the GENIbus communication module is not required, we offer motors without the module. The version is the same for CRE, CRIE, CRNE, CRTE pumps with and without sensor. Figure 80 shows the hardware combination of a standard CRE pump with extended functional module.

0-10 V 0/4-20 mA 4-20 mA

1/0 1/0 1/0

Group 1

13 12 11 10 1 9 8 7

B Y A

STOP RUN 0/4-20 mA 0-10 V


10K

*)

6 5 4 3 2

*) 0.37 - 7.5 kW only: The changeover follows the function of digital input 4. Factory setting: Not active (NO) <-> active (NC)

Fig. 81 Customised CRE pump with extended functional module (0.37 - 22 kW)

59

11
Key
Group No Terminals Basic controller 2 3 4 5 6 Start/stop GND Setpoint input +10 V GND Description

CR, CRI, CRN, CRT,

NC, C, NO Voltage supply 3 L1, N, PE: L1, L2, L3:

Outputs for signal relay

Motor

Single-phase motor Three-phase motor

Fig. 82 Motor combination of customised CRE pumps

Customised CRE pump solutions


As an alternative to the other CRE pump solutions, we offer CRE pump solutions for your requirements! It is possible to put together CRE pumps by selection/deselection: Selection of a control panel on the front of the terminal box of the motor. Note: If the control panel is deselected, a blanking plate is fitted, and the motor cannot communicate with the R100 remote control. Selection of a multi-pump functional module, reduced functional module or other application-specific add-on cards. Note: The motor can only contain one functional module. Selection/deselection of a GENIbus communication module. See also page 61. Our CRE pump solutions make it possible to read in customised configuration files, the so-called gsc files, for optimum operation. The configuration files can be read into the motor during the final test at Grundfos, at start-up or in connection with service by means of Grundfos PC Tool products. Note: When configuration files have been read in, it is still possible to make adjustments. They can be made by means of the R100 remote control, control panel or PC Tool products. See page 63. Figure 82 shows the hardware combination of the motor for a customised CRE pump.

Control panel The control panel on the front of the terminal box of the motor enables setpoint setting and communication.

Three-phase motor

Single-phase motor

Fig. 83 Buttons and for manual setting of the setpoint of the pump

Fig. 84 Communication with the CRE pump by means of the R100 remote control

60

TM02 0936 0501

TM02 8513 0304 - TM00 7600 0304

TM03 4114 1606

CRE pump solutions

Functional module: Extended module (MGE I/O) Multi-pump module (Multi-E) GENIbus communication module (GENI/RS485)

Functional module 13 12 11 10 1 9 8 7 GND Analog output (0-10 V) Digital input 4 Digital input 3 Digital input 2 GND +24 V Sensor input

Terminal box incl. basic frequency converter and basic controller

GENIbus communication module B Y A RS-485B Screen RS-485A

Potential-free signal relay

CR, CRI, CRN, CRT,

11
Superior control system

PROFIBUS or another protocol Gateway

Blanking plate GENIbus

Fig. 85 Motor without control panel

GENIbus communication module The GENIbus communication module enables communication in the following ways: internal bus communication between two or more Grundfos units (GENIbus-based network) external bus communication via a gateway between a Grundfos unit and an external unit, for instance a computer or superior control system (GENIbus to another network protocol).
MPC or another unit Service PC

GR4345

Fig. 87 External bus communication

Gateways can convert GENIbus to other bus protocols.


Third-party gateway Grundfos gateway solutions Bus protocol G100 100 150 200 250 270 G10-LON CIU/CIM

x x x x

x x x

GRM *) * GENIbus
)

Grundfos Remote Monitoring. GRM makes it possible to access pump data on the web. Connection to GRM server is done via SMS or GPRS.

GENIbus is an open protocol which can be implemented into third-party SCADA systems. Contact Grundfos for documentation.
TM04 4591 1709

Fig. 86 Internal bus communication

Must support GENIbus

LonMark PROFIBUS ModBUS Interbus S. GSM

61

CRE pump solutions

The R100 remote control is based on IR communication and is to be pointed at the control panel of the motor during communication. If a motor without control panel is ordered, it is supplied with a blanking plate. See fig. 85. Note: Motors with blanking plate cannot communicate with Grundfos R100.

11
Possible functions The table shows the possible functions of the individual functional modules.
Extended functional module Digital input 1 Start/stop Digital input 2, 3 and 4 Start/stop Deactivation of input (not active) Maximum pressure Minimum pressure Reverse operation Reset alarm External fault Flow switch Emergency operation Predefined speed Analog output Deactivation of output (not active) Actual speed Actual sensor value Actual setpoint value Actual motor current Actual motor load Actual frequency The function is available.

CR, CRI, CRN, CRT,

Voltage signal 0-10 VDC, Ri > 50 k. Tolerance: + 0 %/- 3 % at maximum voltage signal. Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG. Maximum cable length: 100 m. Current signal DC 0-20 mA/4-20 mA, R i = 250 . Tolerance: + 0 %/- 3 % at maximum current signal. Screened cable: 0.25 - 1.5 mm 2 / 24-16 AWG. Maximum cable length: 500 m. Sensor signals Voltage signal 0-10 VDC, Ri > 50 k (via internal voltage supply). Tolerance: + 0 %/- 3 % at maximum voltage signal. Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG. Maximum cable length: 100 m. Current signal DC 0-20 mA/4-20 mA, R i = 250 . Tolerance: + 0 %/- 3 % at maximum current signal. Screened cable: 0.25 - 1.5 mm 2 / 24-16 AWG. Maximum cable length: 500 m. Internal power supplies 10 V power supply for external potentiometer: Max. load: 2.5 mA. Short-circuit protected. 24 V power supply for sensors: Max. load: 40 mA. Short-circuit protected. Signal relay output Potential-free changeover contact. Maximum contact load: 250 VAC, 2 A, cos 0.3 - 1. Minimum contact load: 5 VDC, 10 mA. Screened cable: 0.5 - 2.5 mm2 / 20-14 AWG. Maximum cable length: 500 m. Bus input Grundfos bus protocol, GENIbus protocol, RS-485. Screened 3-core cable: 0.2 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 500 m.

CRE pump solutions


62

Connection of signal transmitters to CRE, CRIE, CRNE, CRTE pumps The functional module enables connection of a number of signal transmitters, such as: pressure sensors differential pressure sensors temperature sensors differential temperature sensors pH meters flowmeters level sensors. Any signal transmitters complying with the values and limits mentioned below may be connected to the pump. Technical data Inputs/output Start/stop External potential-free contact. Voltage: 5 VDC. Current: < 5 mA. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG. Digital External potential-free contact. Voltage: 5 VDC. Current: < 5 mA. Screened cable: 0.25 - 1.5 mm2 / 24-16 AWG. Setpoint signals Potentiometer 0-10 VDC, 10 k (via internal voltage supply). Screened cable: 0.5 - 1.5 mm2 / 20-16 AWG. Maximum cable length: 100 m.

CR, CRI, CRN, CRT,

11
CRE pump solutions
63

Grundfos PC Tool E-products Connection of a Grundfos PC Tool E-products offers a number of advantages during commissioning, operation and service of E-pumps. The PC tool E-products enables these functions: monitoring of operational status of your E-product standard configuration of E-products custom configuration of E-products saving of logged data from E-products. Via the PC Tool, it is possible to download special predefined configuration files (gsc files) to the pump. The configuration files may contain application-optimised operating parameters based on your specifications! Note: When configuration files have been read in, it is still possible to make adjustments. Description The Grundfos PC Tool E-products is a common user platform/user interface used throughout the entire production process of an E-pump. Furthermore, PC Tool E-products can be used by the customer for setting up, commissioning and servicing the E-pump.

Fig. 88 PC Tool E-products used in production and on site by the customer

The Grundfos PC Tool E-products thus enables configuration or reconfiguration of your product to optimise it to exactly your application. And it is indispensable for fault finding and service. The software for Grundfos PC Tool E-products must be ordered with the PC Tool Link package which contains hardware and cables. Contact Grundfos for further information.

TM03 9290 3707

11
CRE pump solutions
Fig. 89 PC Tool interface Fig. 90 Monitoring function

CR, CRI, CRN, CRT,

64

TM04 4607 1809

TM03 3712 0806

CR, CRI, CRN, CRT,

12
How to read the curve charts
TM01 9129 0303

12. How to read the curve charts


CR deep-well

2 1
HD [m]
100 CR(I) 5-15 90 80 70 CR(I) 5-11 60 CR(I) 5-9 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 CR(I) 5-13 No. 11B No. 29B No. 20B No. 22B No. 44B No. 45B

Q [m /h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

0.5

4
Fig. 91 Example of curve chart of CR deep-well
Pos. 1 2 3 4 Description The y-axis indicates the suction depth, HD, in metres. Ejector numbers. QH curve of the individual pump. The bold curves indicate the recommended performance range for best efficiency. The x-axis indicates the flow rate in m3/h and l/s.

65

12
CR low-NPSH and CR pumps with 4-pole motor

CR, CRI, CRN, CRT,

0 0 4 8 12 16 20 24 28 32 36

Q [m/h]

7
Fig. 92 Example of curve chart of CR low-NPSH
Pos. 1 Description Number of stages. First figure: Number of stages. Second figure: Number of reduced-diameter impellers. The power curves indicate pump input power per stage. Curves are shown for pump with one stage (P21), low-NPSH stage (P21n) and reduced-diameter impellers (P2 2/3). Pump type, frequency and ISO standard. QH curve for the individual pump. The bold curves indicate the recommended duty range for best efficiency. The eta curve shows the efficiency of the pump. The eta curve is an average curve of all the pump types shown in the chart. The efficiency of pumps with reduced-diameter impellers is approx. 2 % lower than the eta curve shown in the chart. The NPSH curve is an average curve for all variants shown. When sizing pumps, add a safety margin of at least 0.5 m. QH curve for each individual impeller. Curves for complete (1/1) and reduced-diameter (2/3) impellers are shown.

2 3 4

6 7

66

TM01 9129 0303

How to read the curve charts

p [kPa]

H [m]
280 260 -14 -13 -12 -11 -10 -9 -8 -8-2 140 -7 -7-2 -6 -6-2 100 -5 -5-2 -4 -4-2 60 -3 -3-2 -2 -14-2 -13-2 -12-2 -11-2 -10-2 -9-2

CR, CRN 32
50 Hz
ISO 9906 Annex A

2400

240 220

1
2000

200 180

1600

160

1200

120

800

80

400

40 20

0 0 4 8 12 16 20 24 28 32 36

Q [m/h] Q [l/s]
P21/1n

10

P2 [kW]

Eta [%]
80 60

2.8 2.1 1.4 0.7 0.0 0 4 8 12 16 20 24

Eta

P21/1 P22/3

40 20 0

28

32

36

p H [kPa] [m]
240 160 80 24 16

Q [m/h]
NPSH

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
6 4

QH 2900 rpm2/3 8 Low NPSH 2

CR, CRI, CRN, CRT,

12
How to read the curve charts
67

Guidelines to curve charts


The guidelines below apply to the curves shown on the following pages: Tolerances to ISO 9906, Annex A, if indicated. The motors used for the measurements are standard Grundfos motors (MG or MGE). Measurements have been made with airless water at a temperature of 20 C. Kinematic viscosity of = 1 mm2/s (1 cSt). Due to the risk of overheating, the pumps should not be used at a flow below the minimum flow rate. The QH curves apply to a rated motor speed of 2900 min-1. All curves are based on current motor speeds. The curve below shows the minimum flow rate as a percentage of the nominal flow rate in relation to the liquid temperature. The dotted line shows a CR pump fitted with an air-cooled top assembly.
Qmin [%]
30
TM01 2816 0303

20 10 0 40 60 80 100 120 140 160 180 t

[C]

Fig. 93 Minimum flow rate

13
CR deep-well pumps 50 and 60 Hz Performance curves
68

13. Performance curves


CR deep-well
50 Hz
HD [m]
100 CR(I) 5-15 90 80 70 CR(I) 5-11 60 CR(I) 5-9 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75
TM03 3096 1806

No. 11B

No. 29B

No. 20B

No. 22B

No. 44B

No. 45B

CR(I) 5-13

Q [m /h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

0.5

For information about dimensions of the individual pumps, see page 137.

13
CR deep-well pumps 50 and 60 Hz Performance curves
TM03 3971 1806

CR deep-well
60 Hz
HD [m]
90 80 CR(I) 5-9 70 60 CR(I) 5-6 50 40 30 20 10 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 CR(I) 5-8

No. 11B

No. 29B

No. 20B

No. 22B

No. 44B

No. 45B

Q [m /h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

For information about dimensions of the individual pumps, see page 137.

69

13
Low-NPSH pumps 50 Hz Performance curves
70

Low-NPSH pumps
p [kPa] H [m]
240 220 2000 200 180 1600 160 -23 140 1200 -19 120 -17 100 800 80 60 -8 400 40 20 0 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 -7 -6 -4 -5 -3 -15 -12 -10 -9 -13 -11 -21 -31 -29 -27 -25 -36

CR, CRI, CRN 3


50 Hz
ISO 9906 Annex A -33

Q [m/h] Q [l/s] Eta [%]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

P2 [kW]
0.15 0.10 0.05 0.00 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 P21/1 Eta P21/1n

60 40 20 0

Q [m/h] NPSH [m]

H [m]
QH 2900 rpm1/1n 6 4 2 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 QH 2900 rpm1/1 NPSH Low NPSH

3 2
TMX2 1186 1309

1 0

Q [m/h]

For information about dimensions of the individual pumps, see page 114.

13
Low-NPSH pumps 50 Hz Performance curves
Eta [%]
P21/1n 60 40 P21/1 20 0 0 1 2 3 4 5 6 7 8 9Q

p [kPa]
2400

H [m]
260 -36 240 220 -32 -29 -26 -24 -22 140 -20 -18 -16 100 -15 -14 -13 -12 -11 -10 60 -8 -7 -9 -6 -5 -4 20

CR, CRI, CRN 5


50 Hz
ISO 9906 Annex A

2000

200 180

1600

160

1200

120

800

80

400

40

0 0 1 2 3 4 5 6 7 8 9Q 2.5

[m/h] Q [l/s]

0.0

0.5

1.0

1.5 Eta

2.0

P2 [kW]
0.30 0.20 0.10 0.00

H [m]
12 8 4 QH 2900 rpm1/1n QH 2900 rpm1/1

[m/h] NPSH [m]


6 4 2 0
TMX2 1189 1309

NPSH Low NPSH

0 0 1 2 3 4 5 6 7 8 9Q

[m/h]

For information about dimensions of the individual pumps, see page 115.

71

13
Low-NPSH pumps 50 Hz Performance curves
72

p [kPa]

H [m]
240 220 -22 -20 -18

CR, CRI, CRN 10


50 Hz
ISO 9906 Annex A

2000

200 180

1600

160 140

-16 -14 -12

1200

120 100

-10 -9 -8 -7 -6 -5 -4 -3

800

80 60

400

40 20

0 0 1 2 3 4 5 6 7 8 9 10 11 12

Q [m/h]
3.5

0.0

0.5

1.0

1.5

2.0 Eta

2.5

3.0

Q [l/s]
P21/1n

P2 [kW]
0.6 0.4

Eta [%]
60 40

P21/1 0.2 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 20 0

Q [m/h] NPSH [m]


6 NPSH 4 2 LOW NPSH 0
TM02 7391 1309

H [m]
12 8 4 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

10

11

12

Q [m/h]

For information about dimensions of the individual pumps, see page 115.

13
Low-NPSH pumps 50 Hz Performance curves
Eta [%]
Eta P21/1n P21/1 80 60 40 20 0 0 2 4 6 8 10 12 14 16 18 20 22

p [kPa]

H [m]
240 220

-17

CR, CRI, CRN 15


50 Hz
ISO 9906 Annex A

2000

200 180

-14

-12

1600

160 -10 140 -9

1200

120 100

-8 -7 -6

800

80 60

-5 -4 -3

400

40 20

-2

0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h] Q [l/s]

P2 [kW]
2.0 1.5 1.0 0.5 0.0

Q [m/h]
NPSH

H [m]
20 15 10 5 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
4 3 2
TM02 7392 1309

LOW NPSH

1 0

10

12

14

16

18

20

22

Q [m/h]

For information about dimensions of the individual pumps, see page 116.

73

13
Low-NPSH pumps 50 Hz Performance curves
74

p [kPa]
2400

H [m]
260 240 220 -14 -17

CR, CRI, CRN 20


50 Hz
ISO 9906 Annex A

2000

200 180 -12

1600

160 -10 140

1200

120 100

-8 -7 -6 -5 -4 -3

800

80 60

400

40 20

-2

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

Q [l/s] Eta [%]


80 P21/1n P21/1 60 40 20 0

P2 [kW]
2.0 1.5 1.0 0.5 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Eta

Q [m/h] NPSH [m]


8 NPSH 6 4

H [m]
20 15 10 5 0 0

QH 2900 rpm1/1n QH 2900 rpm1/1

LOW NPSH 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]

For information about dimensions of the individual pumps, see page 116.

TM02 7393 1309

13
Low-NPSH pumps 50 Hz Performance curves
Eta [%]
80 60 P21/1 P22/3 40 20 0 0 4 8 12 16 20 24 28 32 36

p [kPa]

H [m]
280 260 -14 -13 -12 -11 -10 -9 -8 -8-2 140 -7 -7-2 -6 -6-2 100 -5 -5-2 -4 -4-2 60 -3 -3-2 -2 -14-2 -13-2 -12-2 -11-2 -10-2 -9-2

CR, CRN 32
50 Hz
ISO 9906 Annex A

2400

240 220

2000

200 180

1600

160

1200

120

800

80

400

40 20

0 0 4 8 12 16 20 24 28 32 36

Q [m/h] Q [l/s]
P21/1n

10

P2 [kW]
2.8 2.1 1.4 0.7 0.0 Eta

p H [kPa] [m]
240 160 80 0 24 16

Q [m/h]
NPSH

QH 2900 rpm1/1n QH 2900 rpm1/1

NPSH [m]
6 4

QH 2900 rpm2/3 Low NPSH 0 0 4 8 12 16 20 24 28 32 36 0


TM01 9129 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 117.

75

13
Low-NPSH pumps 50 Hz Performance curves
76

p [kPa]
3200

H [m]
340 -13-2 320 -12 300 -12-2 -11-2

CR, CRN 45
50 Hz
ISO 9906 Annex A

2800

280 260

-11 -10

2400

-10-2 240 -9 220 -9-2 -8 -8-2 -7 -7-2 -6 -6-2 -5 120 100 -4 -4-2 -3 -3-2 60 -2 -5-2

2000

200 180

1600

160 140

1200

800

80

400

40 20

0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]
16

10

12

14

P2 [kW]
8 6 4 2 0

Q [l/s]

Eta

Eta [%]
80 60

P21/1n P21/1 P22/3

40 20 0

p H [kPa] [m]
240 160 80 0 24 16 8 0

10

15

20

25

30

35

40

45

50

55

Q [m/h]

QH 2900 rpm1/1n QH 2900 rpm1/1 QH 2900 rpm2/3 NPSH

NPSH [m]
6 4

0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]

For information about dimensions of the individual pumps, see page 118.

TMX1 1451 1309

Low NPSH 2

13
Low-NPSH pumps 50 Hz Performance curves
Eta [%]
80 60 40 20 0 0 10 QH 2900 rpm1/1n QH 2900 rpm1/1 QH 2900 rpm2/3 Low NPSH 0 10 20 30 40 50 60 70 80 NPSH 20 30 40 50 60 70 80

p [kPa]
2000

H [m]
200 -7-1 -7-2 180 -6 -6-1

CR, CRN 64
50 Hz
ISO 9906 Annex A

1600

160 -5 140 -5-1

-6-2

-5-2 1200 120 -4 -4-1 100 -3 800 80 -3-1 -3-2 60 -2 -2-1 400 40 -4-2

20

0 0 10 20 30 40 50 60 70 80

Q [m/h]
25

10

15

20

P2 [kW]
8 6 4 2 0 Eta P21/1n P21/1 P22/3

Q [l/s]

p H [kPa] [m]
300 200 16 100 0 8 0 32 24

Q [m/h]

NPSH [m]
8 6 4
TM02 0753 1309

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 118.

77

13
Low-NPSH pumps 60 Hz Performance curves
78

Low-NPSH pumps
p [Mpa] H [m]
240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 -7 60 -5 0.4 40 -3 20 0.0 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2 -4 -6 -13 -12 -11 -10 -9 -8 -17 -15 -21 -25

CR, CRI, CRN 3


60 Hz
ISO 9906 Annex A -23

-19

Q [m/h] Q [l/s]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2 [kW]
0.24 0.16 0.08 0.00 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2

Eta [%]
60

P21/1n Eta P21/1

40 20 0

p H [kPa] [m]
80 60 40 20 0 9 6 3

Q [m/h]

QH 3500 rpm1/1n QH 3500 rpm1/1 NPSH

NPSH [m]
6 4
TM02 2574 1309

2 Low NPSH 0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 4.8 5.2

Q [m/h]

For information about dimensions of the individual pumps, see page 119.

13
Low-NPSH pumps 60 Hz Performance curves
Eta [%]
60 40 20 P21/1 0.0 0 1 2 3 4 5 6 7 8 9 10 0

p [kPa]

H [m]
240 220 -24

CR, CRI, CRN 5


60 Hz
ISO 9906 Annex A -22 -20

2000

200 180

-18 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4

1600

160 140

1200

120 100

800

80 60

400

40 20

0 0 1 2 3 4 5 6 7 8 9 10

Q [m/h]
3.0

0.0

0.5

1.0

1.5

2.0

2.5

P2 [kW]
1.2 0.8 0.4 Eta P21/1n

Q [l/s]

p [kPa]
150 100 50 0

H [m]
15 10 5 0 0 1 2 3 4 5 6 7 8 9 10 QH 3500 rpm1/1n QH 3500 rpm1/1

Q [m/h]

NPSH [m]
6

NPSH 4
TM02 2575 1309

Low NPSH

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 119.

79

13
Low-NPSH pumps 60 Hz Performance curves
80

p [kPa]
2400

H [m]
260 -17 240 -16 220

CR, CRI, CRN 10


60 Hz
ISO 9906 Annex A

2000

200 180

-14

-12 1600 160 140 1200 120 -8 100 800 80 60 400 40 20 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 -7 -6 -5 -4 -3 -10 -9

Q [m/h] Q [l/s] Eta [%]


80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 P21/1 Eta P21/1n

60 40 20 0

Q [m/h] NPSH [m]


8 6 4
TM02 7394 1309

H [m]
20 15 10 5 0 0

QH 3500 rpm1/1n QH 3500 rpm1/1 NPSH LOW NPSH

2 0

10

11

12

13

14

15

16

Q [m/h]

For information about dimensions of the individual pumps, see page 119.

13
Low-NPSH pumps 60 Hz Performance curves
Eta [%]
Eta P21/1n P21/1 80 60 40 20 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

p [kPa]
2400

H [m]
260 -12 240 220 -10

CR, CRI, CRN 15


60 Hz
ISO 9906 Annex A

2000

200 -9 180 -8

1600

160 -7 140 -6

1200

120 -5 100 -4

800

80 -3 60 -2

400

40 20

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

Q [l/s]

P2 [kW]
3.2 2.4 1.6 0.8 0.0

Q [m/h] NPSH [m]


8 6 NPSH 4

H [m]
20 15 10 5 0 0

QH 3500 rpm1/1n QH 3500 rpm1/1

LOW NPSH 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]

For information about dimensions of the individual pumps, see page 120.

TM02 7395 1309

81

13
Low-NPSH pumps 60 Hz Performance curves
82

p [kPa]
2000

H [m]
200

CR, CRI, CRN 20


60 Hz
ISO 9906 Annex A -8

180 1600

160

-7

140

-6

1200

120 -5 100 -4

800

80 -3 60 -2

400

40

20

0 0 4 8 12 16 20 24 28 32

Q [m/h]
10

Q [l/s] Eta [%]


80

P2 [kW]
3.2 2.4 1.6 0.8 0.0 0 4 8 12 16 20 24 28 32 Eta P21/1n P21/1

60 40 20 0

Q [m/h]
NPSH

H [m]
32 24 16 8 0 0 4 8 12 16 20 24 28 32 QH 3500 rpm1/1n QH 3500 rpm1/1

NPSH [m]
8 6

LOW NPSH

4
TM02 7396 1309

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 120.

13
Low-NPSH pumps 60 Hz Performance curves
Eta [%]
80 P21/1n P21/1 P22/3 60 40 20 0 0 4 8 12 16 20 24 28 32 36 40 44

p [kPa]

H [m]
280 260 -10-2 -9 -9-2 240 -8 220 -8-2 -7 -7-2 180 -6

CR, CRN 32
60 Hz
ISO 9906 Annex A

2400

2000

200

1600

160 140 -5

-6-2

-5-2 1200 120 100 800 80 60 400 40 20 0 0 0 4 8 12 16 20 24 28 32 36 40 44 -3 -3-2 -2 -2-1 -4 -4-2

Q [m/h] Q [l/s]

10

12

P2 [kW]
8 6 4 2 0

Eta

Q [m/h]
NPSH

p H [kPa] [m]
40 320 240 160 80 0 20 10 0 0 4 8 12 16 20 24 28 32 36 40 44 QH 3500 rpm2/3 Low NPSH 30 QH 3500 rpm1/1n QH 3500 rpm1/1

NPSH [m]
8 6 4
TM02 2578 1309

2 0

Q [m/h]

For information about dimensions of the individual pumps, see page 121.

83

13
Low-NPSH pumps 60 Hz Performance curves
84

p [kPa]
2400

H [m]
260 240 220 -6 -7 -7-1 -7-2

CR, CRN 45
60 Hz
ISO 9906 Annex A

-6-1 -6-2

2000

200 180 -5 -5-1 -5-2

1600

160 -4 140 -4-1 -4-2

1200

120 -3 100 -3-1 -3-2

800

80 60

-2 -2-1

400

40 20

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65

Q [m/h] Q [l/s]
P21/1n Eta P21/1 P22/3

10

12

14

16

18

P2 [kW]
8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65

Eta [%]
80 60 40 20 0

p H [kPa] [m]
400 300 200 100 0 40 30 20 10 0 0

Q [m/h]

QH 3500 rpm1/1n QH 3500 rpm1/1 QH 3500 rpm2/3 NPSH

NPSH [m]
8 6 4

Low NPSH 5 10 15 20 25 30 35 40 45 50 55 60 65

Q [m/h]

For information about dimensions of the individual pumps, see page 121.

TM02 2579 1309

13
Low-NPSH pumps 60 Hz Performance curves
Eta [%]
80 Eta P21/1n P21/1 P22/3 4 0 20 0 0 10 20 30 40 50 60 70 80 90 60 40

p [kPa]

H [m]
180 -5-2 -4

CR, CRN 64
60 Hz
ISO 9906 Annex A

1600

160

-4-1 -4-2 -3

140

1200

120

-3-1 -3-2 -2

100

800

80 -2-1 60

400

40

20

0 0 10 20 30 40 50 60 70 80 90

Q [m/h] Q [l/s]

10

15

20

25

P2 [kW]
16 12 8

p H [kPa] [m]
50 400 300 200 100 0 40 30 20 10 0

Q [m/h]

NPSH [m]
10 8 6

QH 3500 rpm1/1n NPSH QH 3500 rpm1/1 QH 3500 rpm2/3 Low NPSH 0 10 20 30 40 50 60 70 80 90

4 2 0
TM02 2580 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 122.

85

13
CR pumps with 4-pole motor 50 Hz Performance curves
86

CR pumps with 4-pole motor


p [kPa] H [m]
55 500 -33 -36

CR, CRI, CRN 1


50 Hz
ISO 9906 Annex A

50

45 400 -27

-30

40

-25 35 300 -23 -21 30 -19 -17 -15 200 20 -12 -11 15 -10 -9 -8 100 10 -7 -6 -5 5 -4 -3 -2 0 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 -13

25

Q [m/h] Q [l/s] Eta [%]


Eta P2 40

0.00

0.05

0.10

0.15

0.20

0.25

0.30

P2 [hp]
0.015 0.010

P2 [kW]
0.010

0.005 0.005 0.000 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

20

Q [m/h] NPSH [m]


1.0

p [kPa]
20

H [m]
2 QH 1450 rpm

10

1 NPSH

0.5
TM02 2543 1309

0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 123.

13
CR pumps with 4-pole motor 50 Hz Performance curves
Eta [%]
60 Eta P2 40 20 0 0.0 0.2 QH 1450 rpm 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

p [kPa]

H [m]
60 55 -36

CR, CRI, CRN 3


50 Hz
ISO 9906 Annex A -33 -31

500

50 -29 45 -27 -25 -23 35 -21 -19 30 -17 25 -15 -12 -10 -8 -9 -7 -5 -4 5 -2 -3 -13 -11 15

400

40

300

200

20

100

10

-6

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0

Q [m/h]
0.6

0.0

0.1

0.2

0.3

0.4

0.5

Q [l/s]

P2 [hp]
0.020 0.015 0.010 0.005 0.000

P2 [kW]
0.015 0.010 0.005 0.000

Q [m/h] NPSH [m]


1.5 1.0

p [kPa]
15 10 5 0

H [m]
1.5 1.0 0.5 0.0 0.0

NPSH

0.5 0.0
TM02 2542 1309

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Q [m/h]

For information about dimensions of the individual pumps, see page 124.

87

13
CR pumps with 4-pole motor 50 Hz Performance curves
88

p [kPa]
600

H [m]
65 -36 60 55

CR, CRI, CRN 5


50 Hz
ISO 9906 Annex A

-32 -29

500

50 45

-26 -24 -22

400

40 35

-20 -18 -16 -15 -13 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

300

30 25

-14 -12

200

20 15

100

10 5

0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

Q [m/h]
1.2

0.0

0.2

0.4

0.6

0.8

1.0

Q [l/s] Eta [%]


60 40 20 0

P2 [hp]
0.020 0.015 0.010 0.005 0.000

P2 [kW]
0.015 0.010 0.005 0.000 0.0 0.4 QH 1450 rpm 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0

P2 Eta

Q [m/h] NPSH [m]


1.5 1.0 0.5

p [kPa]
15 10 5 0

H [m]
1.5 1.0 0.5

NPSH 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 124.

TM02 2541 1309

13
CR pumps with 4-pole motor 50 Hz Performance curves
Eta [%]
Eta P2 60 40 20 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

p [kPa]

H [m]
60 -22 55 -20 50 45 -18 -16 -14 -12 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1

CR, CRI, CRN 10


50 Hz
ISO 9906 Annex A

500

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

Q [m/h] Q [l/s]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

P2 [hp]
0.08 0.06 0.04 0.02 0.00

P2 [kW]
0.06 0.04 0.02 0.00

Q [m/h] NPSH [m]


1.5 1.0 0.5 0.0
TM02 7273 1309

p [kPa]
20

H [m]
2.4 1.6

QH 1450 rpm

10 0

0.8 NPSH 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

Q [m/h]

For information about dimensions of the individual pumps, see page 125.

89

13
CR pumps with 4-pole motor 50 Hz Performance curves
90

p [kPa]

H [m]
60 55 -17

CR, CRI, CRN 15


50 Hz
ISO 9906 Annex A

500

50 45

-14

-12 400 40 35 300 30 25 200 20 -5 15 100 10 -2 5 0 0 0 1 2 3 4 5 6 7 8 9 10 11 -1 -4 -3 -10 -9 -8 -7 -6

Q [m/h] Q [l/s]
Eta P2

0.0

0.5

1.0

1.5

2.0

2.5

3.0

P2 [hp]
0.16 0.12 0.08 0.04 0.00

P2 [kW]
0.12 0.08 0.04 0.00 0 1 QH 1450 rpm 2 3 4 5 6 7 8 9 10 11

Eta [%]
60 40 20 0

Q [m/h] NPSH [m]


1.5 1.0 0.5

p [kPa]
30 20 10 0

H [m]
3 2 1

NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 0.0

Q [m/h]

For information about dimensions of the individual pumps, see page 126.

TM02 7274 1309

13
CR pumps with 4-pole motor 50 Hz Performance curves
Eta [%]
Eta P2 60 40 20 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

p [kPa]
600

H [m]
65 -17 60 55

CR, CRI, CRN 20


50 Hz
ISO 9906 Annex A

500

-14 50 45 -12

400

40 -10 35

300

30 25

-8 -7 -6

200

20 15

-5 -4 -3

100

10 -2 5 -1

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Q [m/h] Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

P2 [hp]
0.20 0.15 0.10 0.05 0.00

P2 [kW]
0.15 0.10 0.05 0.00

Q [m/h] NPSH [m]


1.5 1.0 0.5 0.0
TM02 7275 1309

p [kPa]
30 20 10 0

H [m]
3 2 1

QH 1450 rpm

NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Q [m/h]

For information about dimensions of the individual pumps, see page 126.

91

13
CR pumps with 4-pole motor 50 Hz Performance curves
92

p [kPa]

H [m]
70 65 14 14-2 13 13-2 12 12-2 55 11 11-2 50 45 10 10-2 9 9-2 8 8-2 35 7 7-2 6 6-2 25 5 5-2 4 4-2 15 3 3-2 2 2-2 5 1 1-1

CR, CRN 32
50 Hz
ISO 9906 Annex A

600

60

500

400

40

300

30

200

20

100

10

0 0 2 4 6 8 10 12 14 16 18

Q [m/h] Q [l/s] Eta [%]


80 60 P21/1n P22/3 40 20 0

P2 [hp]
0.5 0.4 0.3 0.2 0.1 0.0

P2 [kW]
0.4 0.3 0.2 0.1 0.0 0 2 4 6 8 10 12

Eta

14

16

18

p [kPa]
40 30 20 10 0

H [m]
5 4 3 2 1 0 0

Q [m/h]

QH 1450 rpm1/1n QH 1450 rpm2/3 NPSH

NPSH [m]
2.5 2.0 1.5 1.0
TM01 8153 1309

0.5 0.0 2 4 6 8 10 12 14 16 18

Q [m/h]

For information about dimensions of the individual pumps, see page 127.

13
CR pumps with 4-pole motor 50 Hz Performance curves
Eta [%]
80 60 40 20 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

p [kPa]
800

H [m]
85 80 75 12 12-2 11 70 65 10 10-2 60 55 9 9-2 8 50 45 7 7-2 6 6 -2 5 5-2 4 4-2 3 3-2 2 2-2 1 5 1-1 8-2 11-2 13-2

CR, CRN 45
50 Hz
ISO 9906 Annex A

700

600

500

400

40 35

300

30 25

200

20 15

100

10

0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]
8

P2 P2 [hp] [kW]
0.4 0.4 0.2 0.1 0.0 0.0 0.3 0.2

Q [l/s]
P21/1n P22/3

Eta

Q [m/h] NPSH [m]


1.5 1.0

p H [kPa] [m]
60 40 20 0 6 4 2 0 0

QH 1450 rpm1/1n QH 1450 rpm2/3 NPSH

0.0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Q [m/h]

For information about dimensions of the individual pumps, see page 128.

TM01 8154 1309

0.5

93

13
CR pumps with 4-pole motor 50 Hz Performance curves
94

p [kPa]

H [m]
55 7

8-1 8-2

CR, CRN 64
50 Hz
ISO 9906 Annex A

500

50 6

7-1 7-2

45 400

6-1 40 5 35 300 4 4-1 25 3 200 20 2 2-1 100 10 2-2 1 1-1 5 3-1 3-2 15 4-2 5-1 5-2 30 6-2

0 0 5 10 15 20 25 30 35 40

Q [m/h] Q [l/s]

8 Eta P21/1n P22/3

10

P2 [hp]
1.0 0.8 0.6 0.4 0.2 0.0

P2 [kW]
0.8 0.6 0.4 0.2 0.0 0 5 QH 1450 rpm1/1n QH 1450 rpm2/3 10 15 20 25 30

Eta [%]
80 60 40 20 0

35

40

p H [kPa] [m]
60 40 20 0 6 4

Q [m/h]

NPSH [m]
1.2 0.8

NPSH 2 0 0 5 10 15 20 25 30 35 40 0.4 0.0


TM01 8155 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 129.

13
CR pumps with 4-pole motor 50 Hz Performance curves

p [kPa]
500

H [m]
50

CR, CRN 90
50 Hz
ISO 9906 Annex A 6-2

45 5 400 40

5-2 35 4

300

30 3 25

4-2

200

20 2 15

3-2

2-2 100 10 1 1-1 5

0 0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]
16

10

12 Eta

14

P2 [hp]
1.0 0.5

P2 [kW]
1.00 0.75

Q [l/s]

Eta [%]
80 60

P21/1n P22/3 0.50 0.25 0.0 0.00 0 5 10 15 20 25 30 35 40 45 50 55 40 20 0

p H [kPa] [m]
80 60 40 20 0 8 6 4 2 0 0

Q [m/h]

QH 1450 rpm1/1n QH 1450 rpm2/3

NPSH [m] NPSH


1.6 1.2 0.8
TM01 8156 1309

0.4 0.0 5 10 15 20 25 30 35 40 45 50 55

Q [m/h]

For information about dimensions of the individual pumps, see page 129.

95

13
CR pumps with 4-pole motor 50 Hz Performance curves
96

p [kPa]
500

H [m]
7 50

CR, CRN 120


50 Hz
ISO 9906 Annex A

45 6-1 400 40

35

5-1

300

30 4-1 25 3

200

20

15

2 2-1

100

10 1 5

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Q [m/h] Q [l/s]

10

12

14

16

18

20

P2 [hp]
2.0 1.5 1.0 0.5 0.0

P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Eta P21/1n P22/3

Eta [%]
80 60 40 20 0

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 NPSH QH 1450 rpm1/1n QH 1450 rpm2/3

Q [m/h]

NPSH [m]
2.0 1.5 1.0 0.5 0.0
TM03 9077 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 130.

13
CR pumps with 4-pole motor 50 Hz Performance curves
Eta [%]
80 P21/1n P22/3 60 40 20 0 0 10 20 30 40 50 60 70 80 90

p [kPa]
500

H [m]
50 6 45

CR, CRN 150


50 Hz
ISO 9906 Annex A

400

40

35

5-2

300

30

4-1

25

200

20

3-2

15

2-1

100

10 1 1-1 5

0 0 10 20 30 40 50 60 70 80 90

Q [m/h]
26 28 Q

10

12

14

16

18

20

22

24

P2 [hp]
2.0 1.5 1.0 0.5 0.0

P2 [kW]
1.6 1.2 0.8 0.4 0.0 Eta

[l/s]

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0 0 10 20 30 40 50 60 70 80 90 NPSH QH 1450 rpm1/1n QH 1450 rpm2/3

Q [m/h]

NPSH [m]
4 3 2 1 0
TM03 9078 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 130.

97

13
CR pumps with 4-pole motor 60 Hz Performance curves
98

CR pumps with 4-pole motor

p [kPa]

H [m]
60 55 -27 -25 -23 -21 45 -19

CR, CRI, CRN 1


60 Hz
ISO 9906 Annex A

500

50

400

40 -17 35 -15

300

30 -13 25 -12 -11 -10 -9 -8 15 -6 -7 -5 -4 -3 5 -2

200

20

100

10

0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

Q [m/h] Q [l/s]

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40

P2 [hp]
0.020 0.015 0.010 0.005 0.000

P2 [kW]
0.015 0.010 0.005 0.000 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

Eta [%]
60

P2 Eta

40 20 0

p [kPa]
30 20 10 0

H [m]
3 QH 1750 rpm 2 1 NPSH 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

Q [m/h]

NPSH [m]
1.5 1.0 0.5 0.0
TM02 2540 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 131.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
60 Eta P2 0.01 0.00 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 20 0 40

p [kPa]

H [m]
60 55 -25

CR, CRI, CRN 3


60 Hz
ISO 9906 Annex A -23

500

50 45

-21 -19 -17 -15 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6

Q [m/h] Q [l/s]

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

P2 [hp]
0.04 0.03 0.02 0.01 0.00

P2 [kW]
0.03 0.02

p H [kPa] [m]
30 20 10 0 3 QH 1750 rpm 2 1 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 NPSH

Q [m/h]

NPSH [m]
1.5 1.0 0.5 0.0
TM02 2539 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 131.

99

13
CR pumps with 4-pole motor 60 Hz Performance curves
100

p [kPa]

H [m]
60 55 -24

CR, CRI, CRN 5


60 Hz
ISO 9906 Annex A -22 -20 -18 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2

500

50 45

400

40 35

300

30 25

200

20 15

100

10 5

0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Q [m/h] Q [l/s] Eta [%]


P2 Eta 60 40 20 0

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

P2 [hp]
0.04 0.03 0.02 0.01 0.00

P2 [kW]
0.03 0.02 0.01 0.00 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

Q [m/h] NPSH [m]


1.5

p [kPa]
30 20 10 0

H [m]
3 QH 1750 rpm 2 1 NPSH 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0

1.0 0.5 0.0


TM02 2538 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 132.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
60 40 20 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5

p [kPa]
600

H [m]
65 60 55

-17

CR, CRI, CRN 10


60 Hz
ISO 9906 Annex A

-16

-14 500 50 45 400 40 -10 35 300 30 25 -6 200 20 15 100 10 5 0 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 -5 -4 -3 -2 -1 -9 -8 -7 -12

Q [m/h] Q [l/s]
P2 Eta

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

P2 [hp]
0.08 0.06 0.04 0.02 0.00

P2 [kW]
0.06 0.04 0.02 0.00

Q [m/h] NPSH [m]


1.5 1.0 0.5 0.0
TM02 7276 1309

p [kPa]
30 20 10 0

H [m]
3.0 2.0 1.0

QH 1750 rpm

NPSH 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5

Q [m/h]

For information about dimensions of the individual pumps, see page 132.

101

13
CR pumps with 4-pole motor 60 Hz Performance curves
102

p [kPa]

H [m]
60 55

-12

CR, CRI, CRN 15


60 Hz
ISO 9906 Annex A

500

50 45

-10 -9

400

40 35

-8 -7 -6 -5

300

30 25

200

20 15

-4 -3 -2 -1

100

10 5

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

Q [m/h] Q [l/s] Eta [%]


60 40 20 0

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5 Eta P2

4.0

P2 [hp]
0.20 0.15 0.10 0.05 0.00

P2 [kW]
0.15 0.10 0.05 0.00 0 1 2 3 4 5 6 7 8 9 10 11 12 13

14

Q [m/h] NPSH [m]


1.5

p [kPa]
60 40 20 0

H [m]
6 QH 1750 rpm 4 2 NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

1.0 0.5 0.0


TM02 7277 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 133.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
Eta P2 60 40 20 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

p [kPa]

H [m]
55 -10

CR, CRI, CRN 20


60 Hz
ISO 9906 Annex A

500

50

45 -8 400 40 -7 35 -6 300 30 -5 25 -4 200 20 -3 15 -2 10 -1

100

0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Q [m/h] Q [l/s]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

P2 [hp]
0.3 0.2 0.1 0.0

P2 [kW]
0.24 0.16 0.08 0.00

Q [m/h] NPSH [m]

p [kPa]
60 40 20 0

H [m]
6 4 2 NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 QH 1750 rpm

3 2 1 0
TM02 7278 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 133.

103

13
CR pumps with 4-pole motor 60 Hz Performance curves
104

p [kPa]

H [m]
70 10-2 65 -9 9-2 -8 55 8-2 -7 7-2 45 -6 6-2 -5 35 5-2

CR, CRN 32
60 Hz
ISO 9906 Annex A

600

60

500

50

400

40

300

30 25

-4 4-2 -3 -

200

20 15 -2

3-2

100

10 5

2-1 2-2 -1 1-1

0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h] Q [l/s]

P2 P2 0 [hp] [kW]
0.6 0.4 0.2 0.1 0.0 0.0 0.4 0.3 0.2

Eta [%]
80 60 40 20 0

Eta

P21/1 P22/3

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0

10

12

14

16

18

20

22

Q [m/h]

NPSH [m]
4 3

QH 1750 rpm1/1 QH 1750 rpm2/3 NPSH

2
TM01 8157 1309

1 0 0 2 4 6 8 10 12 14 16 18 20 22

Q [m/h]

For information about dimensions of the individual pumps, see page 134.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
80 60 40 20 0 0 4 8
QH 1750 rpm1/1 QH 1750 rpm2/3

p [kPa]
600

H [m]
65 60

7 7-1 7-2

CR, CRN 45
60 Hz
ISO 9906 Annex A

6 55 500 50 5 45 400 40 4 35 300 30 25 200 20 15 100 10 5 0 0 0 4 8 12 16 20 24 28 32 1 1-1 2 2-1 2-2 4-1 4-2 3 3-1 3-2 5-1 5-2 6-1 6-2

Q [m/h]
10

P2 P2 [hp] [kW]
1.0 0.8 0.6 0.4 0.2 0.0 0.2 0.0 0.8 0.6 0.4

Q [l/s]

Eta P21/1 P22/3

p [kPa]
80 60 40 20 0

H [m]
8 6 4 2 0

12

16

20

24

28

32

Q [m/h]

NPSH [m]
2.0 1.5 1.0

NPSH

0.0 0 4 8 12 16 20 24 28 32

Q [m/h]

For information about dimensions of the individual pumps, see page 134.

TM01 8158 1309

0.5

105

13
CR pumps with 4-pole motor 60 Hz Performance curves
106

p [kPa]

H [m]
45 4

5-2

CR, CRN 64
60 Hz
ISO 9906 Annex A

400

40

4-1 4-2

35 3 300 30 3-1 3-2 2 200 20 2-1 15 1 100 10 1-1 5 2-2

25

0 0 5 10 15 20 25 30 35 40 45

Q [m/h]
14 Q

10

12

[l/s] Eta [%]


80

P2 [hp]
1.6 0.8

P2 [kW]
1.6 1.2 0.8 0.4

Eta P21/1 P22/3

60 40 20 0

0.0

0.0

p [kPa]
80 60 40 20 0

H [m]
10 8 6 4 2 0

5 QH 1750 rpm1/1 QH 1750 rpm2/3

10

15

20

25

30

35

40

45

Q [m/h]
NPSH

NPSH [m]
2.0 1.6 1.2 0.8 0.4 0.0
TM01 8159 1309

10

15

20

25

30

35

40

45

Q [m/h]

For information about dimensions of the individual pumps, see page 135.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
80 P21/1 P22/3 60 40 20 0 0 10 20 30 40 50 60 70

p [kPa]
400

H [m]
40 3 35 3-1 4-2

CR, CRN 90
60 Hz
ISO 9906 Annex A

300

30 3-2 25 2

200

20

2-1 2-2

15 1 100 10

1-1

0 0 10 20 30 40 50 60 70

Q [m/h]
20

12 Eta

16

Q [l/s]

P2 [hp]
2 1

P2 [kW]
2.0 1.5 1.0 0.5

0.0

Q [m/h] NPSH [m]

p [kPa]
120 80 40 0

H [m]
12 8 4 0 0 10 20 30 40 50 60 70 QH 1750 rpm1/1 NPSH QH 1750 rpm2/3

3 2 1 0
TM01 8160 1309

Q [m/h]

For information about dimensions of the individual pumps, see page 135.

107

13
CR pumps with 4-pole motor 60 Hz Performance curves
108

p [kPa]
500

H [m]
50 5-2 45

CR, CRN 120


60 Hz
ISO 9906 Annex A

400

40

4-1

35 3 300 30 3-1

25 2 200 20 2-1 2-2 1 100 10

15

0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

Q [m/h] Q [l/s]

10

12

14

16

18

20

P2 [hp]
2.5 2.0 1.5 1.0 0.5 0.0

P2 [kW]
2.0 1.5 1.0 0.5 0.0 Eta 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 P21/1 P22/3

Eta [%]
80 60 40 20 0

p [kPa]
100 80 60 40 20 0

H [m]
10 8 6 4 2 0

Q [m/h]

QH 1750 rpm1/1 QH 1750 rpm2/3

NPSH [m]
2.5 2.0 1.5

NPSH

1.0 0.5 0.0


TM03 9079 1309

10

15

20

25

30

35

40

45

50

55

60

65

70

75

Q [m/h]

For information about dimensions of the individual pumps, see page 135.

13
CR pumps with 4-pole motor 60 Hz Performance curves
Eta [%]
80 Eta P21/1 P22/3 60 40 20 0 0 10 20 30 40 50 60 70 80 90

p [kPa]
400

H [m]
40 4-2

CR, CRN 150


60 Hz
ISO 9906 Annex A

35

300

30 3-2 25 2

200

20

2-1 2-2

15 1 100 10 1-1

0 0 10 20 30 40 50 60 70 80 90

Q [m/h]
26 28 Q

10

12

14

16

18

20

22

24

P2 [hp]
4 3 2 1 0

P2 [kW]
3.2 2.4 1.6 0.8 0.0

[l/s]

p [kPa]
100 80 60 40 20 0

H [m]
12 10 8 6 4 2 0

Q [m/h] NPSH [m]


3.0 2.5 2.0 1.5 1.0 0.5 0.0
TM03 9080 1309

QH 1750 rpm1/1 QH 1750 rpm2/3

NPSH

10

20

30

40

50

60

70

80

90

Q [m/h]

For information about dimensions of the individual pumps, see page 136.

109

14
CR low-NPSH pumps 50 and 60 Hz Technical data
110

14. Technical data


CR low-NPSH pumps
Dimensional drawings

D2 D1

B2

CR 1 CR 3
B1

G 1/2

G 1/2

FGJ (DIN-ANSI-JIS) PN 25 / DN 25/32


G 1/2 19 x 24.5 G 1/2 22 89 100 140 75

A (Oval)

Rp 1 M10 x 40

100 141 250

35 180 220

4 x 13.5

100 145 160

75 180 220

4 x 13.5

D2 D1

B2

G 1/2

G 1/2 D3

CR 5
B1

FGJ (DIN-ANSI-JIS) PN 25 / DN 25/32


G 1/2 19 x 24.5 G 1/2 22
89 100 140 75

A (Oval)

Rp 1 1/4" M10 x 40

100 141 250

35 180 220

4 x 13.5

100 145 160

75 180 220

4 x 13.5

TM03 1723 2805

50

20

20

TM03 1721 2805

50

20

20

14
CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz Technical data
G 1/2 D3 FJ (DIN-JIS) PN 16-25 / DN 40 B1 G 1/2 18 x 20.2 39 114 150 G 1/2 27 20 A (oval) Rp 1 1/2" M12 x 45 4 x 13.5 20 110 215 256 4 x 13.5 130 178 200 100 215 256

D2 D1

B2

CR 10

G 1/2

130 178 280

D2 D1

B2

G 1/2 G 1/2 D3

B1

CR 15 CR 20

F (DIN) PN 16-25 / DN 50
G 1/2 4 x 13.5 18.1 125 165 18 x 21.5 G 1/2 20

GJ (ANSI-JIS)
65 G 1/2 30 127 165 M12 x 45

A (oval)
Rp 2"

90

90

90

20

215 256

D2 D1

B2

D3

CR 32
G 1/2 PN16-25-40/DN65 B1 G 1/2 8 x 18

107 145 185

170 223 320

30

4 x 14 74 240 298

TM01 1749 5197

G 1/2 105

TM03 1727 2805

130 176 300

65

130 176 300

120 215 256

130 178 200

130 215 256

20

TM03 1725 2805

80

80

111

14
CR low-NPSH pumps CR pumps with 4-pole motor 50 and 60 Hz Technical data
CR 45
G 1/2 PN16-25-40/DN80 B1 G 1/2 8 x 18 D2 D1

B2

D3

120 160 200

190 248 365

80 266 331

D2 D1 F (DIN) PN25-40/DN100 8 x 22
B2

D3

45

100

CR 64
B1

G 1/2

266 331 F (DIN) PN16/DN100 G 1/2 8 x 18

150 180 220

190 248 365

45

100

4 x 14

266 331

CR 90

112

TM01 1755 2203

TM01 1753 5197

G 1/2
140

150 190 235

G 1/2

45

4 x 14

4 x 14

TM01 1751 5197

G 1/2 140

14
CR pumps with 4-pole motor 50 and 60 Hz Technical data
CR 120 CR 150
TM03 5999 4106

113

14
CR low-NPSH pumps 50 Hz Technical data
114

CR low-NPSH pump
Dimensions and weights CR 3 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 CR 3-27 CR 3-29 CR 3-31 CR 3-33 CR 3-36 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.0 279 297 315 333 351 375 393 411 429 447 465 501 553 589 625 661 697 733 769 809 845 899 Dimension [mm] DIN flange B1+B2 470 488 506 524 542 606 624 642 660 678 696 732 834 870 946 982 1018 1054 1090 1144 1180 1234 Oval flange B1 254 272 290 308 326 350 368 386 404 422 440 476 528 564 600 636 B1+B2 445 463 481 499 517 581 599 617 635 653 671 707 809 845 921 957 D1 141 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 178 178 198 198 198 D2 109 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 110 120 120 120 D3 Net weight [kg] DIN flange 23 23 24,5 25 25 27 28 28 31 31 31 32 40 41 42 43 44 45 46 51 51 53 Oval flange 18 19 19,5 20 21 23 23 24 26 26 27 28 36 37 38 39 -

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 50 Hz Technical data
115 CR 5 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 CR 5-26 CR 5-29 CR 5-32 CR 5-36 0.75 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 2.2 3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5 333 366 393 420 447 490 517 544 571 598 625 652 679 737 791 845 899 953 1034 1145 1253 Dimension [mm] DIN flange B1+B2 564 597 624 651 678 771 798 865 892 919 946 973 1000 1072 1126 1217 1271 1325 1406 1536 1644 Oval flange B1 308 341 368 395 422 465 492 519 546 573 600 627 654 712 766 820 B1+B2 539 572 599 626 653 746 773 840 867 894 921 948 975 1047 1101 1194 D1 141 141 141 141 141 178 178 178 178 178 178 178 178 198 198 220 220 220 220 220 220 D2 109 109 109 109 109 110 110 110 110 110 110 110 110 120 120 134 134 134 134 134 134 D3 300 300 Net weight [kg] DIN flange 26,5 27 30 30 31 38 39 40 41 41 42 43 43 48 50 62 63 64 66 82 84 Oval flange 21,5 22 25 26 26 34 34 36 36 37 37 38 38 44 45 56 -

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 10 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-18 CR 10-20 CR 10-22 1.1 1.5 2.2 2.2 3.0 3.0 4.0 4.0 4.0 5.5 5.5 7.5 7.5 7.5 377 423 453 483 518 548 578 608 668 760 820 880 940 1000 Dimension [mm] DIN flange B1+B2 608 704 734 764 853 883 950 980 1040 1151 1211 1271 1331 1391 Oval flange B1 377 423 453 483 518 548 578 608 668 760 820 B1+B2 608 704 734 764 853 883 950 980 1040 1151 1211 D1 141 178 178 178 198 198 220 220 220 220 220 220 220 220 D2 109 110 110 110 120 120 134 134 134 134 134 134 134 134 D3 300 300 300 300 300 Net weight [kg] DIN flange 39 47 49 50 55 56 68 69 71 94 96 113 115 117 Oval flange 37 45 46 47 52 53 65 66 69 91 93 -

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 50 Hz Technical data
116 CR 15 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 CR 15-14 CR 15-17 3.0 4.0 4.0 5.5 5.5 7.5 7.5 11.0 11.0 11.0 15.0 15.0 415 465 510 555 632 677 722 767 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 750 837 882 946 1023 1068 1113 1238 1360 1450 1540 1675 Oval flange B1 415 465 510 555 632 677 B1+B2 750 837 882 946 1023 1068 D1 198 220 220 220 220 220 220 314 314 314 314 314 D2 120 134 134 134 134 134 134 204 204 204 204 204 D3 300 300 300 350 350 350 350 350 Net weight [kg] DIN flange 54 66 68 75 91 108 109 128 132 136 177 177 Oval flange 53 65 67 74 90 107 -

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 20 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 CR 20-12 CR 20-14 CR 20-17 3.0 4.0 5.5 7.5 7.5 11.0 11.0 11.0 15.0 15.0 18.5 415 465 542 587 632 677 799 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 736 837 933 978 1023 1148 1270 1360 1450 1540 1719 Oval flange B1 415 465 542 587 632 677 B1+B2 736 837 933 978 1023 1148 D1 178 220 220 220 220 314 314 314 314 314 314 D2 110 134 134 134 134 204 204 204 204 204 204 D3 300 300 300 300 350 350 350 350 350 Net weight [kg] DIN flange 50 66 88 102 105 139 129 132 168 172 199 Oval flange 49 65 87 101 104 138 -

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 50 Hz Technical data
117 CR 32 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 CR 32-10 CR 32-11-2 CR 32-11 CR 32-12-2 CR 32-12 CR 32-13-2 CR 32-13 CR 32-14-2 CR 32-14 4.0 5.5 5.5 7.5 7.5 11.0 11.0 11.0 11.0 15.0 15.0 15.0 15.0 18.5 18.5 18.5 18.5 22.0 22.0 22.0 22.0 30.0 30.0 30.0 30.0 575 645 645 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 1455 1455 1525 1525 Dimension [mm] DIN flange B1+B2 947 1036 1036 1106 1106 1366 1366 1436 1436 1506 1506 1576 1576 1690 1690 1760 1760 1856 1856 1926 1926 2101 2101 2171 2171 Oval flange B1 B1+B2 D1 220 220 220 220 220 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 415 415 415 415 D2 134 134 134 134 134 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 300 300 300 300 D3 158 298 298 298 298 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 400 400 400 400 Net weight [kg] DIN flange 87 107 107 129 129 157 157 160 160 195 195 198 198 223 223 226 226 247 247 251 251 322 322 325 325 Oval flange -

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 50 Hz Technical data
118 CR 45 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 45-2 CR 45-3-2 CR 45-3 CR 45-4-2 CR 45-4 CR 45-5-2 CR 45-5 CR 45-6-2 CR 45-6 CR 45-7-2 CR 45-7 CR 45-8-2 CR 45-8 CR 45-9-2 CR 45-9 CR 45-10-2 CR 45-10 CR 45-11-2 CR 45-11 CR 45-12-2 CR 45-12 CR 45-13-2 7.5 11.0 11.0 15.0 15.0 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 45.0 45.0 45.0 45.0 45.0 639 829 829 909 909 989 989 1069 1069 1149 1149 1229 1229 1309 1309 1389 1389 1469 1469 1549 1549 1629 Dimension [mm] DIN flange B1+B2 1030 1300 1300 1380 1380 1504 1504 1610 1610 1795 1795 1875 1875 1955 2012 2092 2092 2178 2178 2258 2258 2338 Oval flange B1 B1+B2 D1 220 314 314 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 442 442 D2 134 204 204 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 325 325 D3 298 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 450 450 Net weight [kg] DIN flange 122 151 151 189 189 216 216 237 237 321 321 336 336 341 361 366 366 478 478 483 483 488 Oval flange -

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 64 low-NPSH pumps, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 CR 64-5-1 CR 64-5 CR 64-6-2 CR 64-6-1 CR 64-6 CR 64-7-2 CR 64-7-1 CR 64-7 CR 64-8-2 CR 64-8-1 11.0 11.0 15.0 15.0 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 37.0 45.0 45.0 45.0 754 754 836 836 836 919 919 919 1001 1001 1001 1084 1084 1084 1166 1166 1166 1249 1249 Dimension [mm] DIN flange B1+B2 1225 1225 1307 1307 1351 1434 1460 1460 1647 1647 1647 1730 1787 1787 1869 1869 1875 1958 1958 Oval flange B1 B1+B2 D1 314 314 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 D2 204 204 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 D3 350 350 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 Net weight [kg] DIN flange 151 151 194 194 216 226 242 242 316 316 316 336 356 356 376 376 440 473 473 Oval flange -

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 60 Hz Technical data
119 CR 3 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 0.55 0.55 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 2.2 3.0 3.0 3.0 4.0 279 297 321 339 357 375 409 427 445 463 481 517 553 593 629 665 701 Dimension [mm] DIN flange B1+B2 470 488 552 570 588 606 690 708 726 784 802 838 874 928 964 1000 1073 Oval flange B1 254 272 296 314 332 350 384 402 420 438 456 492 528 B1+B2 445 463 527 545 563 581 665 683 701 759 777 813 849 D1 141 141 141 141 141 141 178 178 178 178 178 178 178 198 198 198 220 D2 109 109 109 109 109 109 110 110 110 110 110 110 110 120 120 120 134 D3 Net weight [kg] DIN flange 24 24 26 29 29 29 37 37 38 39 39 40 41 46 47 47 59 Oval flange 19 19 22 24 24 25 32 33 33 34 34 35 36 -

Note: CR 3 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 5 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 1.1 1.5 2.2 2.2 2.2 2.2 3.0 3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5 5.5 7.5 339 382 409 436 463 490 521 548 575 602 629 656 683 767 821 875 929 Dimension [mm] DIN flange B1+B2 570 663 730 757 784 811 856 883 910 974 1001 1028 1055 1158 1212 1266 1308 Oval flange B1 314 357 384 411 438 465 496 523 550 577 604 631 658 B1+B2 545 638 705 732 759 786 831 858 885 949 976 1003 1030 D1 141 178 178 178 178 178 198 198 198 220 220 220 220 220 220 220 220 D2 109 110 110 110 110 110 120 120 120 134 134 134 134 134 134 134 134 D3 300 300 300 300 Net weight [kg] DIN flange 28 36 37 38 38 39 44 44 45 56 57 58 58 74 75 76 79 Oval flange 24 32 33 33 34 34 39 40 40 52 53 53 54 -

Note: CR 5 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 60 Hz Technical data
120 CR 10 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-17 2.2 3.0 4.0 4.0 5.5 5.5 5.5 7.5 7.5 11.0 11.0 11.0 393 428 458 488 550 580 610 640 700 837 897 957 Dimension [mm] DIN flange B1+B2 674 763 830 860 941 971 1001 1019 1079 1308 1368 1428 Oval flange B1 393 428 458 488 550 580 610 640 B1+B2 674 763 830 860 941 971 1001 1019 D1 198 198 220 220 220 220 220 220 220 314 314 314 D2 120 120 134 134 134 134 134 134 134 204 204 204 D3 300 300 300 300 300 350 350 350 Net weight [kg] DIN flange 47 52 64 65 87 88 89 104 106 129 131 133 Oval flange 44 49 61 62 84 85 86 101 -

Note: CR 10 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 15 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 5.5 5.5 7.5 11.0 11.0 15.0 15.0 15.0 18.5 18.5 420 465 542 587 709 754 799 844 889 979 Dimension [mm] DIN flange B1+B2 811 856 921 1058 1180 1225 1270 1315 1404 1494 Oval flange B1 420 465 542 587 B1+B2 811 856 921 1058 D1 220 220 220 314 314 314 314 314 314 314 D2 134 134 134 204 204 204 204 204 204 204 D3 300 300 350 350 350 350 350 350 Net weight [kg] DIN flange 71 72 103 136 126 152 154 163 175 190 Oval flange 70 71 102 135 -

Note: CR 15 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 20 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 5.5 7.5 11.0 11.0 15.0 15.0 18.5 420 497 542 664 709 754 799 Dimension [mm] DIN flange B1+B2 811 876 1013 1135 1180 1225 1314 Oval flange B1 420 497 542 664 B1+B2 811 876 1013 1135 D1 220 220 314 314 314 314 314 D2 134 134 204 204 204 204 204 D3 300 350 350 350 350 350 Net weight [kg] DIN flange 71 102 134 124 151 159 171 Oval flange 70 101 133 123 -

Note: CR 20 low-NPSH pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 60 Hz Technical data
121 CR 32 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 32-2-1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 5.5 7.5 11.0 11.0 11.0 15.0 15.0 18.5 18.5 18.5 22.0 22.0 30.0 30.0 30.0 30.0 30.0 575 575 755 755 825 825 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 Dimension [mm] DIN flange B1+B2 966 954 1226 1226 1296 1296 1366 1410 1480 1480 1576 1576 1751 1751 1821 1821 1891 Oval flange B1 B1+B2 D1 220 220 314 314 314 314 314 314 314 314 314 314 415 415 415 415 415 D2 148 134 204 204 204 204 204 204 204 204 204 204 300 300 300 300 300 D3 298 298 350 350 350 350 350 350 350 350 350 350 400 400 400 400 400 Net weight [kg] DIN flange 98 112 146 146 154 186 189 211 214 214 233 233 305 305 308 308 311 Oval flange -

Note: CR 32 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 45 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 45-2-1 CR 45-2 CR 45-3-2 CR 45-3-1 CR 45-3 CR 45-4-2 CR 45-4-1 CR 45-4 CR 45-5-2 CR 45-5-1 CR 45-5 CR 45-6-2 CR 45-6-1 CR 45-6 CR 45-7-2 CR 45-7-1 CR 45-7 11.0 15.0 18.5 18.5 18.5 22.0 30.0 30.0 30.0 30.0 30.0 37.0 37.0 37.0 45.0 45.0 45.0 749 749 829 829 829 909 909 909 989 989 989 1069 1069 1069 1149 1149 1149 Dimension [mm] DIN flange B1+B2 1220 1220 1344 1344 1344 1450 1555 1555 1635 1635 1635 1772 1772 1772 1858 1858 1858 Oval flange B1 B1+B2 D1 314 314 314 314 314 314 415 415 415 415 415 415 415 415 442 442 442 D2 204 204 204 204 204 204 300 300 300 300 300 300 300 300 325 325 325 D3 350 350 350 350 350 350 400 400 400 400 400 400 400 400 450 450 450 Net weight [kg] DIN flange 147 179 205 205 205 227 296 296 301 301 301 326 326 326 405 405 405 Oval flange -

Note: CR 45 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR low-NPSH pumps 60 Hz Technical data
122 CR 64 low-NPSH pumps, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 18.5 22.0 22.0 30.0 30.0 37.0 37.0 45.0 45.0 754 754 836 836 836 919 919 919 1001 Dimension [mm] DIN flange B1+B2 1269 1295 1377 1482 1482 1622 1622 1628 1710 Oval flange B1 B1+B2 D1 314 314 314 415 415 415 415 442 442 D2 204 204 204 300 300 300 300 325 325 D3 350 350 350 400 400 400 400 450 450 Net weight [kg] DIN flange 205 221 232 301 301 331 331 395 400 Oval flange -

Note: CR 64 low-NPSH pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
CR Pump type Motor P2 [kW] B1 CR 1-2 CR 1-3 CR 1-4 CR 1-5 CR 1-6 CR 1-7 CR 1-8 CR 1-9 CR 1-10 CR 1-11 CR 1-12 CR 1-13 CR 1-15 CR 1-17 CR 1-19 CR 1-21 CR 1-23 CR 1-25 CR 1-27 CR 1-30 CR 1-33 CR 1-36 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 279 279 297 315 333 351 369 387 405 423 447 465 501 537 573 609 645 697 733 787 841 895 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 542 560 578 596 614 638 656 692 728 764 800 836 888 924 978 1032 1086 Oval flange B1 254 254 272 290 308 326 344 362 380 398 422 440 476 512 548 584 620 B1+B2 445 445 463 481 499 517 535 553 571 589 613 631 667 703 739 775 811 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 Net weight [kg] DIN flange 22 22 22 23 23 24 25 25 25 26 28 28 29 32 33 34 35 43 43 45 46 48 Oval flange 17 17 18 18 19 19 20 20 21 21 23 24 25 28 28 29 30 -

CR pumps with 4-pole motor


Dimensions and weights CR 1 with 4-pole motor, 50 Hz

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

123

14
CR pumps with 4-pole motor 50 Hz Technical data
124 CR 3 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 3-2 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 CR 3-27 CR 3-29 CR 3-31 CR 3-33 CR 3-36 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,37 0,37 0,37 0,37 279 279 297 315 333 351 375 393 411 429 447 465 501 553 589 625 661 697 733 769 809 845 899 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 542 566 584 602 620 638 656 692 744 780 816 852 888 924 960 1000 1036 1090 Oval flange B1 254 254 272 290 308 326 350 368 386 404 422 440 476 528 564 600 636 B1+B2 445 445 463 481 499 517 541 559 577 595 613 631 667 719 755 791 827 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 Net weight [kg] DIN flange 22 22 22 23 24 24 26 27 27 30 30 30 31 39 40 41 42 43 44 46 51 51 53 Oval flange 17 17 18 18 19 20 22 22 23 25 25 26 27 35 36 37 38 -

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
125 CR 5 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 5-2 CR 5-3 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 CR 5-26 CR 5-29 CR 5-32 CR 5-36 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,37 0,37 0,37 0,37 0,55 0,55 0,55 0,55 0,75 279 306 333 366 393 420 447 490 517 544 571 598 625 652 679 737 791 845 899 953 1034 1145 1253 Dimension [mm] DIN flange B1+B2 470 497 524 557 584 611 638 681 708 735 762 789 816 843 870 928 982 1036 1130 1184 1265 1376 1534 Oval flange B1 254 281 308 341 368 395 422 465 492 519 546 573 600 627 654 712 766 820 B1+B2 445 472 499 532 559 586 613 656 683 710 737 764 791 818 845 903 957 1011 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 178 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 200 200 200 200 200 Net weight [kg] DIN flange 22 23 24 26 29 29 30 37 38 39 40 40 41 42 43 48 50 62 62 63 65 81 83 Oval flange 17 19 19 21 24 25 25 33 33 35 35 36 36 37 38 44 45 56 -

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 10 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 10-1 CR 10-2 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-18 CR 10-20 CR 10-22 0,25 0,25 0,25 0,25 0,25 0,25 0,37 0,37 0,37 0,55 0,6 0,75 0,75 0,75 1,1 1,1 343 347 377 423 453 483 518 548 578 608 668 760 820 880 940 1000 Dimension [mm] DIN flange B1+B2 534 538 568 614 644 674 709 739 769 839 899 1041 1101 1161 1261 1321 Oval flange B1 343 347 377 423 453 483 518 548 578 608 668 760 820 B1+B2 534 538 568 614 644 674 709 739 769 839 899 1041 1101 D1 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 110 110 D3 160 160 160 160 160 160 160 160 160 200 200 200 200 200 200 200 Net weight [kg] DIN flange 33 35 38 46 48 49 55 56 57 68 70 93 95 100 98 100 Oval flange 30 33 36 44 45 46 52 53 54 65 68 90 92 -

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
126 CR 15 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 15-1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 CR 15-14 CR 15-17 0,25 0,25 0,37 0,55 0,55 0,75 0,75 1,1 1,1 1,1 1,5 1,5 2,2 400 415 465 510 555 632 677 722 767 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 591 606 656 741 786 913 958 1043 1088 1210 1260 1350 1525 Oval flange B1 400 415 465 510 555 632 677 B1+B2 591 606 656 741 786 913 958 D1 141 141 141 141 141 178 178 178 178 178 178 178 198 D2 109 109 109 109 109 109 109 110 110 110 110 110 120 D3 160 160 160 200 200 200 200 200 200 200 200 200 250 Net weight [kg] DIN flange 41 49 55 67 68 90 92 92 93 125 134 138 157 Oval flange 40 48 54 66 67 89 91 -

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 20 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 20-1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 CR 20-12 CR 20-14 CR 20-17 0,25 0,37 0,55 0,6 0,75 1,1 1,1 1,1 1,5 2,2 2,2 2,2 400 415 465 542 587 632 677 799 889 979 1069 1204 Dimension [mm] DIN flange B1+B2 591 606 696 773 868 953 998 1120 1170 1300 1390 1525 Oval flange B1 400 415 465 542 587 632 677 B1+B2 591 606 696 773 868 953 998 D1 141 141 141 141 178 178 178 178 178 198 198 198 D2 109 109 109 109 109 110 110 110 110 120 120 120 D3 160 160 200 200 200 200 200 200 200 250 250 250 Net weight [kg] DIN flange 41 50 65 87 89 88 90 122 130 148 152 187 Oval flange 40 49 64 86 88 -

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
127 CR 32 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 32-1-1 CR 32-1 CR 32-2-2 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 CR 32-10 CR 32-11-2 CR 32-11 CR 32-12-2 CR 32-12 CR 32-13-2 CR 32-13 CR 32-14-2 CR 32-14 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 2,2 2,2 2,2 2,2 2,2 2,2 2,2 3 3 3 3 3 3 3 505 505 575 575 645 645 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 1455 1455 1525 1525 Dimension [mm] DIN flange B1+B2 786 786 856 856 926 926 996 996 1176 1176 1246 1246 1316 1316 1426 1426 1496 1496 1566 1566 1636 1650 1720 1720 1790 1790 1860 1860 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 178 178 178 178 178 178 178 198 198 198 198 198 198 198 198 198 198 198 198 198 198 D2 110 110 110 110 110 110 110 110 110 110 110 110 110 110 120 120 120 120 120 120 120 120 120 120 120 120 120 120 D3 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 250 Net weight [kg] DIN flange 61 62 76 87 107 107 117 117 155 155 158 158 175 175 178 178 211 211 214 214 250 249 253 253 321 321 324 324 Oval flange -

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
128 CR 45 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 45-1-1 CR 45-1 CR 45-2-2 CR 45-2 CR 45-3-2 CR 45-3 CR 45-4-2 CR 45-4 CR 45-5-2 CR 45-5 CR 45-6-2 CR 45-6 CR 45-7-2 CR 45-7 CR 45-8-2 CR 45-8 CR 45-9-2 CR 45-9 CR 45-10-2 CR 45-10 CR 45-11-2 CR 45-11 CR 45-12-2 CR 45-12 CR 45-13-2 1,5 1,5 1,5 1,5 1,5 1,5 1,5 2,2 2,2 2,2 3 3 3 3 4 4 4 4 4 4 5,5 5,5 5,5 5,5 5,5 559 559 639 639 829 829 909 909 989 989 1069 1069 1149 1149 1229 1229 1309 1309 1389 1389 1469 1469 1549 1549 1629 Dimension [mm] DIN flange B1+B2 840 840 920 920 1110 1110 1190 1230 1310 1310 1404 1404 1484 1484 1601 1601 1681 1681 1761 1761 1860 1860 1940 1940 2020 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 220 220 260 260 260 260 260 D2 110 110 110 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 134 134 159 159 159 159 159 D3 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 300 300 300 300 300 Net weight [kg] DIN flange 80 91 108 110 149 149 169 169 204 204 239 239 320 320 336 336 341 361 366 366 487 487 492 492 497 Oval flange -

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
129 CR 64 with 4-pole motor, 50 Hz
CR Pump type Motor P2 [kW] B1 CR 64-1-1 CR 64-1 CR 64-2-2 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 CR 64-5-1 CR 64-5 CR 64-6-2 CR 64-6-1 CR 64-6 CR 64-7-2 CR 64-7-1 CR 64-7 CR 64-8-2 1,5 1,5 1,5 1,5 1,5 2,2 2,2 2,2 3 3 3 3 4 4 4 4 4 5,5 5,5 5,5 5,5 561 561 644 754 754 836 836 836 919 919 919 1001 1001 1001 1084 1084 1084 1166 1166 1166 1249 Dimension [mm] DIN flange B1+B2 842 842 925 1035 1035 1157 1157 1157 1254 1254 1254 1336 1373 1373 1456 1456 1456 1557 1557 1557 1640 Oval flange B1 B1+B2 D1 178 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 220 260 260 260 260 D2 110 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 134 159 159 159 159 D3 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 300 300 300 300 Net weight [kg] DIN flange 91 102 114 149 149 174 174 204 213 244 244 315 316 316 336 356 356 385 385 449 482 Oval flange -

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 90 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 90-1-1 CR 90-1 CR 90-2-2 CR 90-2 CR 90-3-2 CR 90-3 CR 90-4-2 CR 90-4 CR 90-5-2 CR 90-5 CR 90-6-2 CR 90-6 1,5 1,5 1,5 2,2 2,2 3 4 4 4 5,5 5,5 5,5 571 571 773 773 865 865 957 957 1049 1049 1141 1141 Dimension [mm] DIN flange B1+B2 852 852 1054 1094 1186 1200 1329 1329 1421 1440 1532 1532 Oval flange B1 B1+B2 D1 178 178 178 198 198 198 220 220 220 260 260 260 D2 110 110 110 120 120 120 134 134 134 159 159 159 D3 200 200 200 250 250 250 250 250 250 300 300 300 Net weight [kg] DIN flange 80,4 80,4 85,3 85,6 90,7 94,7 110,7 110,7 117,2 128,4 134,1 133,4 Oval flange -

Note: 4-pole CR 90 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 50 Hz Technical data
130 CR 120 with 4-pole motor, 50 HZ
CR Pump type Motor P2 [kW] B1 CR 120-1 CR 120-2-1 CR 120-2 CR 120-3 CR 120-4-1 CR 120-5-1 CR 120-6-1 CR 120-7 1,5 2,2 3 4 5,5 5,5 7,5 11 834 990 990 1145 1301 1456 1642 1797 Dimension [mm] DIN flange B1+B2 1115 1311 1325 1517 1692 1847 2071 2268 Oval flange B1 B1+B2 D1 178 198 198 220 260 260 260 314 D2 110 120 120 134 159 159 159 204 D3 200 250 250 250 300 300 300 350 Net weight [kg] DIN flange 113 131 133 148 185 194 220 267 Oval flange -

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 150 with 4-pole motor, 50 Hz


CR Pump type Motor P2 [kW] B1 CR 150-1-1 CR 150-1 CR 150-2-1 CR 150-3-2 CR 150-3 CR 150-4-1 CR 150-5-2 CR 150-6 1,5 2,2 3 4 5,5 5,5 7,5 11 834 834 990 1145 1145 1301 1486 1642 Dimension [mm] DIN flange B1+B2 1115 1155 1325 1517 1536 1692 1915 2113 Oval flange B1 B1+B2 D1 178 198 198 220 260 260 260 314 D2 110 120 120 134 159 159 159 204 D3 200 250 250 250 300 300 300 350 Net weight [kg] DIN flange 113 122 133 148 175 184 210 258 Oval flange -

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
131 CR 1 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 1-2 CR 1-3 CR 1-4 CR 1-5 CR 1-6 CR 1-7 CR 1-8 CR 1-9 CR 1-10 CR 1-11 CR 1-12 CR 1-13 CR 1-15 CR 1-17 CR 1-19 CR 1-21 CR 1-23 CR 1-25 CR 1-27 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,37 279 279 297 315 333 357 375 393 411 429 447 465 517 553 589 625 661 697 737 Dimension [mm] DIN flange B1+B2 470 470 488 506 524 548 566 584 602 620 638 656 708 744 780 816 852 888 928 Oval flange B1 254 254 272 290 308 332 350 368 386 404 422 440 492 528 B1+B2 445 445 463 481 499 523 541 559 577 595 613 631 683 719 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 Net weight [kg] DIN flange 22 22 22 23 24 26 26 27 29 30 30 30 38 39 41 41 42 43 49 Oval flange 17 17 18 19 19 21 22 22 25 25 25 26 34 35 -

Note: 4-pole CR 1 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 3 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 3-2 CR 3-3 CR 3-4 CR 3-5 CR 3-6 CR 3-7 CR 3-8 CR 3-9 CR 3-10 CR 3-11 CR 3-12 CR 3-13 CR 3-15 CR 3-17 CR 3-19 CR 3-21 CR 3-23 CR 3-25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,37 0,37 0,37 0,37 0,55 279 279 297 321 339 357 375 409 427 445 463 481 517 553 593 629 665 701 Dimension [mm] DIN flange B1+B2 470 470 488 512 530 548 566 600 618 636 654 672 708 744 784 820 856 932 Oval flange B1 254 254 272 296 314 332 350 384 402 420 438 456 492 528 B1+B2 445 445 463 487 505 523 541 575 593 611 629 647 683 719 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 120 Net weight [kg] DIN flange 22 23 23 25 28 28 28 36 36 37 38 38 39 41 46 47 47 58 Oval flange 17 18 18 21 23 23 24 31 32 32 33 33 34 36 -

Note: 4-pole CR 3 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
132 CR 5 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 5-2 CR 5-3 CR 5-4 CR 5-5 CR 5-6 CR 5-7 CR 5-8 CR 5-9 CR 5-10 CR 5-11 CR 5-12 CR 5-13 CR 5-14 CR 5-15 CR 5-16 CR 5-18 CR 5-20 CR 5-22 CR 5-24 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,25 0,37 0,37 0,37 0,37 0,55 0,55 0,55 0,55 0,75 0,75 0,75 279 312 339 382 409 436 463 490 521 548 575 602 629 656 683 767 821 875 929 Dimension [mm] DIN flange B1+B2 470 503 530 573 600 627 654 681 712 739 766 793 860 887 914 998 1052 1106 1160 Oval flange B1 254 287 314 357 384 411 438 465 496 523 550 577 604 631 658 B1+B2 445 478 505 548 575 602 629 656 687 714 741 768 835 862 889 D1 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 D2 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 109 D3 105 105 105 105 105 105 105 105 105 105 105 105 120 120 120 120 120 120 120 Net weight [kg] DIN flange 22 27 27 35 36 37 37 38 44 44 45 56 56 57 57 73 74 75 78 Oval flange 18 22 23 31 32 32 33 33 39 40 40 52 52 52 53 -

Note: 4-pole CR 5 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 10 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 10-1 CR 10-2 CR 10-3 CR 10-4 CR 10-5 CR 10-6 CR 10-7 CR 10-8 CR 10-9 CR 10-10 CR 10-12 CR 10-14 CR 10-16 CR 10-17 0,25 0,25 0,25 0,37 0,37 0,55 0,55 0,75 0,75 0,75 1,1 1,1 1,5 1,5 347 363 393 428 458 488 550 580 610 640 700 837 897 957 Dimension [mm] DIN flange B1+B2 538 554 584 619 649 719 781 811 841 871 981 1118 1178 1238 Oval flange B1 347 363 393 428 458 488 550 580 610 640 B1+B2 538 554 584 619 649 719 781 811 841 871 D1 141 141 141 141 141 141 141 141 141 141 178 178 178 178 D2 109 109 109 109 109 109 109 109 109 109 110 110 110 110 D3 105 105 105 105 105 120 120 120 120 120 135 135 135 135 Net weight [kg] DIN flange 35 44 46 52 53 64 86 87 88 91 89 122 129 131 Oval flange 32 42 43 49 50 61 83 84 85 88 -

Note: 4-pole CR 10 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
133 CR 15 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 15-1 CR 15-2 CR 15-3 CR 15-4 CR 15-5 CR 15-6 CR 15-7 CR 15-8 CR 15-9 CR 15-10 CR 15-12 0,25 0,37 0,55 0,75 1,1 1,1 1,5 1,5 2,2 2,2 2,2 415 420 465 542 587 709 754 799 844 889 979 Dimension [mm] DIN flange B1+B2 606 611 696 773 868 990 1035 1080 1179 1224 1314 Oval flange B1 415 420 465 542 587 B1+B2 606 611 696 773 868 D1 141 141 141 141 178 178 178 178 198 198 198 D2 109 109 109 109 110 110 110 110 120 120 120 D3 105 105 120 120 135 135 135 135 160 160 160 Net weight [kg] DIN flange 48 54 65 87 87 119 125 127 143 145 178 Oval flange 47 53 64 86 86 -

Note: 4-pole CR 15 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

CR 20 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 20-1 CR 20-2 CR 20-3 CR 20-4 CR 20-5 CR 20-6 CR 20-7 CR 20-8 CR 20-10 0,25 0,55 0,75 1,1 1,5 1,5 2,2 2,2 3 415 420 497 542 664 709 754 799 889 Dimension [mm] DIN flange B1+B2 606 651 728 823 945 990 1089 1134 1224 Oval flange B1 415 420 497 542 664 B1+B2 606 651 728 823 945 D1 141 141 141 178 178 178 198 198 198 D2 109 109 109 110 110 110 120 120 120 D3 105 120 120 135 135 135 160 160 160 Net weight [kg] DIN flange 49 64 86 85 122 124 139 141 174 Oval flange 48 63 85 84 121 -

Note: 4-pole CR 20 pumps are also available as CRI and CRN pumps with PJE and CA connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
134 CR 32 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 32-1-1 CR 32-1 CR 32-2-2 CR 32-2-1 CR 32-2 CR 32-3-2 CR 32-3 CR 32-4-2 CR 32-4 CR 32-5-2 CR 32-5 CR 32-6-2 CR 32-6 CR 32-7-2 CR 32-7 CR 32-8-2 CR 32-8 CR 32-9-2 CR 32-9 CR 32-10-2 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5 2,2 2,2 2,2 2,2 2,2 3 3 3 3 4 4 4 505 505 575 575 575 755 755 825 825 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 Dimension [mm] DIN flange B1+B2 786 786 856 856 856 1036 1036 1106 1160 1230 1230 1300 1300 1370 1370 1440 1440 1547 1547 1617 Oval flange B1 B1+B2 D1 178 178 178 178 178 178 178 178 198 198 198 198 198 198 198 198 198 220 220 220 D2 110 110 110 110 110 110 110 110 120 120 120 120 120 120 120 120 120 134 134 134 D3 135 135 135 135 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 160 Net weight [kg] DIN flange 62 66 98 98 100 144 144 152 166 169 199 202 202 235 235 304 304 308 308 311 Oval flange -

Note: 4-pole CR 32 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 45 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 45-1-1 CR 45-1 CR 45-2-2 CR 45-2-1 CR 45-2 CR 45-3-2 CR 45-3-1 CR 45-3 CR 45-4-2 CR 45-4-1 CR 45-4 CR 45-5-2 CR 45-5-1 CR 45-5 CR 45-6-2 CR 45-6-1 CR 45-6 CR 45-7-2 CR 45-7-1 CR 45-7 1,5 1,5 1,5 1,5 2,2 2,2 2,2 2,2 3 3 3 4 4 4 4 5,5 5,5 5,5 5,5 5,5 559 559 749 749 749 829 829 829 909 909 909 989 989 989 1069 1069 1069 1149 1149 1149 Dimension [mm] DIN flange B1+B2 840 840 1030 1030 1084 1164 1164 1164 1244 1244 1244 1361 1361 1361 1441 1448 1448 1528 1528 1528 Oval flange B1 B1+B2 D1 178 178 178 178 198 198 198 198 198 198 198 220 220 220 220 260 260 260 260 260 D2 110 110 110 110 120 120 120 120 120 120 120 134 134 134 134 159 159 159 159 159 D3 135 135 135 135 160 160 160 160 160 160 160 160 160 160 160 300 300 300 300 300 Net weight [kg] DIN flange 102 104 145 145 159 193 193 193 229 295 295 301 301 301 326 335 335 414 414 414 Oval flange -

Note: 4-pole CR 45 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
135 CR 64 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 64-1-1 CR 64-1 CR 64-2-2 CR 64-2-1 CR 64-2 CR 64-3-2 CR 64-3-1 CR 64-3 CR 64-4-2 CR 64-4-1 CR 64-4 CR 64-5-2 1,5 1,5 2,2 2,2 3 3 4 4 4 5,5 5,5 5,5 561 671 754 754 754 836 836 836 919 919 919 1001 Dimension [mm] DIN flange B1+B2 842 952 1089 1089 1089 1171 1208 1208 1291 1298 1298 1380 Oval flange B1 B1+B2 D1 178 178 198 198 198 198 220 220 220 260 260 260 D2 110 110 120 120 120 120 134 134 134 159 159 159 D3 135 135 160 160 160 160 160 160 160 300 300 300 Net weight [kg] DIN flange 104 139 163 193 223 234 301 301 331 340 404 409 Oval flange -

Note: 4-pole CR 64 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 90 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 90-1-1 CR 90-1 CR 90-2-2 CR 90-2-1 CR 90-2 CR 90-3-2 CR 90-3-1 CR 90-3 CR 90-4-2 1,5 2,2 3 3 4 4 5,5 5,5 5,5 681 681 773 773 773 865 865 865 957 Dimension [mm] DIN flange B1+B2 962 1016 1108 1108 1145 1237 1244 1244 1336 B1 Oval flange B1+B2 D1 178 198 198 198 220 220 260 260 260 D2 110 120 120 120 134 134 159 159 159 D3 135 160 160 160 160 160 300 300 300 Net weight [kg] DIN flange 144 158 193 224 291 331 340 404 419 Oval flange -

Note: 4-pole pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

CR 120 with 4-pole motor, 60 Hz


CR Pump type Motor P2 [kW] B1 CR 120-1 CR 120-2-2 CR 120-2-1 CR 120-2 CR 120-3-1 CR 120-3 CR 120-4-1 CR 120-5-2 2,2 3 4 5,5 5,5 7,5 11 11 834 990 990 990 1145 1175 1331 1486 Dimension [mm] DIN flange B1+B2 1169 1325 1362 1369 1524 1604 1802 1957 Oval flange B1 B1+B2 D1 198 198 220 260 260 260 314 314 D2 120 120 134 159 159 159 204 204 D3 270 270 270 300 300 300 350 350 Net weight [kg] DIN flange 119 134 143 148 153 168 209 218 Oval flange -

Note: 4-pole CR 120 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

14
CR pumps with 4-pole motor 60 Hz Technical data
136 CR 150 with 4-pole motor, 60 Hz
CR Pump type Motor P2 [kW] B1 CR 150-1-1 CR 150-1 CR 150-2-2 CR 150-2-1 CR 150-2 CR 150-3-2 CR 150-3 CR 150-4-2 2,2 3 4 5,5 5,5 7,5 11 11 834 834 990 990 990 1175 1175 1331 Dimension [mm] DIN flange B1+B2 1169 1169 1362 1369 1369 1604 1646 1802 Oval flange B1 B1+B2 D1 198 198 220 260 260 260 314 314 D2 120 120 134 159 159 159 204 204 D3 270 270 270 300 300 300 350 350 Net weight [kg] DIN flange 119 125 144 149 149 168 199 208 Oval flange -

Note: 4-pole CR 150 pumps are also available as CRN pumps with PJE connection. For information about electrical data, see pages 160 to 161.

15
CR deep-well pumps 50 and 60 Hz Technical data
TM03 8261 0907

15. Technical data


CR deep-well pumps
Dimensional drawing

Air vent screw G 1/8"

CR 5

Priming plug G 1

137

15
CR deep-well pumps 50 and 60 Hz Technical data
138

CR deep-well pumps, 50 Hz
Dimensions and weights
Motor P2 [kW] 1.5 Dimensions [mm] B1 465 B1+B2 746 C1 85 D1 178 D2 110 Suction depth [m] 54 42 35 27 65 50 45 40 35 28 79 63 54 45 40 33 93 73 62 53 46 37 Pipe dimensions [mm] Largest Flow Pressure class, ejector rate Ejector plastic pipe Ejector inlet: Ejector outlet: diameter No [m3/h] [kp/cm2] external/internal external/internal [mm] 0.25 0.68 0.92 1.25 0.25 0.62 0.85 1.10 1.37 1.75 0.25 0.62 0.87 1.17 1.39 1.99 0.25 0.63 0.88 1.14 1.40 1.99 11 29 20 22 11 29 20 22 44 45 11 29 20 22 44 45 11 29 20 22 44 45 6+6 6+6 6+6 6+6 10+10 10+6 6+6 6+6 6+6 6+6 10+10 10+10 10+6 10+6 6+6 6+6 10+10 10+10 10+10 10+6 10+6 10+6 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/22.8 32/22.8 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 76 76 76 76 80 76 76 76 76 76 80 80 76 76 76 76 80 80 80 76 76 76

Pump

CR(I) 5-9

CR(I) 5-11

2.2

519

840

85

178

110

CR(I) 5-13

2.2

573

894

85

178

110

CR(I) 5-15

2.2

627

948

85

178

110

Note: For information about electrical data, see pages 160 to 161.

CR deep-well pumps, 60 Hz
Dimensions and weights
Motor P2 [kW] 2.2 Dimensions [mm] B1 384 B1+B2 705 C1 85 D1 179 D2 110 Suction depth, [m] 52 45 41 37 34 30 65 60 53 50 45 73 65 60 55 50 47 Flow rate [m3/h] 0.33 0.69 0.91 1.16 1.35 1.65 0.38 0.60 0.94 1.10 1.37 0.37 0.68 0.88 1.11 1.39 1.63 Ejector No 11 29 20 22 44 45 11 29 20 22 44 11 29 20 22 44 45 Pipe dimensions [mm] Largest Pressure class, ejector plastic pipe Ejector inlet: Ejector outlet: diameter [kp/cm2] external/internal external/internal [mm] 6+6 6+6 6+6 6+6 6+6 6+6 10+10 10+6 6+6 6+6 6+6 10+10 10+10 10+6 10+6 6+6 6+6 32/26 32/26 32/26 32/26 32/26 32/26 32/22.8 32/22.8 32/26 32/26 32/26 32/22.8 32/22.8 32/22.8 32/22.8 32/26 32/26 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 40/28.4 40/28.4 40/32.6 40/32.6 40/32.6 40/32.6 76 76 76 76 76 76 80 76 76 76 76 80 80 76 76 76 76

Pump

CR(I) 5-6

CR(I) 5-8

2.2

438

759

85

179

110

CR(I) 5-9

2.2

465

786

85

179

110

Note: For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz Technical data
TM03 9138 3407 TM03 9137 3407

16. Technical data


CRN pumps with magnetic drive
Dimensional drawings

CRN 1 CRN 3

CRN 5

139

16
CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz Technical data
CRN 10 CRN 15 CRN 20
D2 D1 B2 D3

CRN 32
G 1/2 PN16-25-40/DN65 B1 G 1/2 8 x 18

107 145 185

G 1/2 105

170 226 320

30

4 x 14
74 240 298

140

TM01 1750 2203

TM03 9139 3407

TM03 9140 3407

16
CRN pumps with magnetic drive (MAGdrive) 50 and 60 Hz Technical data
D3 PN16-25-40/DN80 B1 G 1/2 8 x 18 120 160 200 80 266 331 45 4 x 14

D2 D1

CRN 45
G 1/2

B2

190 251 365

D2 D1 F (DIN) PN25-40/DN100 8 x 22

B2

D3

CRN 64
G 1/2

45

100

266 331 F (DIN) PN16/DN100

B1

G 1/2

8 x 18

150 180 220

190 251 365


D2 D1

45

100

4 x 14

266 331

F (DIN) PN25-40/DN100 8 x 22

B2

D3

45

100

CRN 90
B1

G 1/2

280 348 F (DIN) PN16/DN100 G 1/2 8 x 18

156 180 235

199 261 380

45

100

4 x 14

280 348

TM02 1570 2203

G 1/2

140

156 190 235

G 1/2

4 x 14

TM01 1754 0904

G 1/2

140

150 190 235

G 1/2

4 x 14

TM01 1752 2203

G 1/2 140

141

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
142

CRN pumps with magnetic drive


Dimensions and weights CRN 1s - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 367 385 403 421 439 457 475 493 511 529 547 583 619 655 697 733 769 805 859 913 967 558 558 576 594 612 630 648 666 684 702 720 738 774 810 886 928 964 1000 1036 1090 1144 1198 Oval flange 342 342 360 378 396 414 432 450 468 486 504 522 558 594 630 672 708 744 780 834 888 942 533 533 551 569 587 605 623 641 659 677 695 713 749 785 861 903 939 975 1011 1065 1119 1173 B1 B1+B2 B1 B1+B2 CRN 1s-2 CRN 1s-3 CRN 1s-4 CRN 1s-5 CRN 1s-6 CRN 1s-7 CRN 1s-8 CRN 1s-9 CRN 1s-10 CRN 1s-11 CRN 1s-12 CRN 1s-13 CRN 1s-15 CRN 1s-17 CRN 1s-19 CRN 1s-21 CRN 1s-23 CRN 1s-25 CRN 1s-27 CRN 1s-30 CRN 1s-33 CRN 1s-36 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 D1 Net weight [kg] D2 D3 DIN flange Oval flange 24 25 25 25 26 26 27 27 27 29 29 30 30 31 33 35 35 39 39 40 41 43 20 20 21 21 22 22 22 23 23 24 25 25 26 27 28 30 31 35 35 36 37 38

141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
143 CRN 1 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 367 385 403 421 439 457 475 493 511 535 553 589 625 661 697 733 785 821 875 929 983 558 558 576 594 612 630 648 666 684 702 720 738 774 810 886 928 964 1000 1036 1090 1144 1198 Oval flange 342 342 360 378 396 414 432 450 468 486 504 522 558 594 630 672 708 744 780 834 888 942 533 533 551 569 587 605 623 641 659 677 695 713 749 785 861 903 939 975 1011 1065 1119 1173 B1 B1+B2 B1 B1+B2 CRN 1-2 CRN 1-3 CRN 1-4 CRN 1-5 CRN 1-6 CRN 1-7 CRN 1-8 CRN 1-9 CRN 1-10 CRN 1-11 CRN 1-12 CRN 1-13 CRN 1-15 CRN 1-17 CRN 1-19 CRN 1-21 CRN 1-23 CRN 1-25 CRN 1-27 CRN 1-30 CRN 1-33 CRN 1-36 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 D1 Net weight [kg] D2 D3 DIN flange Oval flange 24 25 25 25 26 26 27 27 27 29 29 30 30 31 33 35 35 39 39 40 41 43 20 20 21 21 22 22 22 23 23 24 25 25 26 27 28 30 31 35 35 36 37 38

141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
144 CRN 3 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 367 385 403 421 439 463 481 499 517 535 553 589 641 677 713 749 785 821 857 897 933 987 558 558 576 594 612 630 694 712 730 748 766 784 820 922 958 1034 1070 1106 1142 1178 1232 1268 1322 Oval flange 342 342 360 378 396 414 438 456 474 492 510 528 564 616 652 688 724 760 796 832 872 908 962 533 533 551 569 587 605 669 687 705 723 741 759 795 897 933 1009 1045 1081 1117 1153 1207 1243 1297 B1 B1+B2 B1 B1+B2 CRN 3-2 CRN 3-3 CRN 3-4 CRN 3-5 CRN 3-6 CRN 3-7 CRN 3-8 CRN 3-9 CRN 3-10 CRN 3-11 CRN 3-12 CRN 3-13 CRN 3-15 CRN 3-17 CRN 3-19 CRN 3-21 CRN 3-23 CRN 3-25 CRN 3-27 CRN 3-29 CRN 3-31 CRN 3-33 CRN 3-36 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3 3 3 D1 Net weight [kg] D2 D3 DIN flange Oval flange 24 25 25 26 27 27 30 30 30 33 33 34 35 43 44 45 46 47 47 48 53 54 55 20 20 21 22 22 23 25 26 26 29 29 30 30 39 39 41 42 42 43 44 49 50 51

141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110 178 110 178 110 198 120 198 120 198 120

For information about electrical data, see pages 160 to 161.

CRN 5 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN 5-2 CRN 5-3 CRN 5-4 CRN 5-5 CRN 5-6 CRN 5-7 CRN 5-8 CRN 5-9 CRN 5-10 CRN 5-11 CRN 5-12 CRN 5-13 CRN 5-14 CRN 5-15 CRN 5-16 CRN 5-18 CRN 5-20 CRN 5-22 CRN 5-24 CRN 5-26 CRN 5-29 CRN 5-32 CRN 5-36 0.37 0.55 0.75 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3 3 3 4 4 4 5.5 5.5 5.5 367 394 421 454 481 508 535 578 605 632 659 686 713 740 767 825 879 933 987 1041 1122 1254 1362 B1+B2 558 585 652 685 712 739 766 859 886 953 980 1007 1034 1061 1102 1160 1214 1305 1359 1413 1513 1645 1753 Oval flange B1 342 369 396 429 456 483 510 553 580 607 634 661 688 715 742 800 854 908 962 1016 1097 1229 1337 B1+B2 533 560 627 660 687 714 741 834 861 928 955 982 1009 1036 1077 1135 1189 1280 1334 1388 1488 1620 1728 D1 D2 Net weight [kg] D3 DIN flange Oval flange 26 27 28 30 33 33 34 41 42 43 43 44 45 45 49 51 52 65 67 68 77 92 94 21 23 24 26 29 29 30 37 37 39 39 40 40 41 44 47 48 61 62 64 72 88 90

141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110 178 110 178 110 178 110 198 120 198 120 220 134 220 134 220 134

220 134 300 220 134 300 220 134 300

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
145 CRN 10 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN 10-1 CRN 10-2 CRN 10-3 CRN 10-4 CRN 10-5 CRN 10-6 CRN 10-7 CRN 10-8 CRN 10-9 CRN 10-10 CRN 10-12 CRN 10-14 CRN 10-16 CRN 10-18 CRN 10-20 CRN 10-22 0.55 0.75 1.1 1.5 2.2 2.2 3 3 4 4 5.5 5.5 5.5 7.5 7.5 11 443 447 477 523 553 583 618 648 678 708 768 860 920 980 1040 1100 B1+B2 634 678 708 804 874 904 953 983 1050 1080 1159 1251 1311 1359 1419 1571 Oval flange B1 443 447 477 523 553 583 618 648 678 708 768 860 920 980 1040 1100 B1+B2 634 678 708 804 874 904 953 983 1050 1080 1159 1251 1311 1359 1419 1571 D1 D2 Net weight [kg] D3 DIN flange Oval flange 40 41 45 53 55 56 61 62 74 74 76 99 101 121 123 191 36 38 41 49 51 52 57 59 71 71 73 95 97 118 120 157

141 109 141 109 141 109 178 110 178 110 178 110 198 120 198 120 198 120 220 134

220 134 300 220 134 300 220 134 300 260 159 300 260 159 300 314 204 350

For information about electrical data, see pages 160 to 161.

CRN 15 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN 15-1 CRN 15-2 CRN 15-3 CRN 15-4 CRN 15-5 CRN 15-6 CRN 15-7 CRN 15-8 CRN 15-9 CRN 15-10 CRN 15-12 CRN 15-14 CRN 15-17 1.1 2.2 3 4 5.5 5.5 7.5 7.5 7.5 11 11 15 15 490 505 555 600 645 722 767 812 857 979 1069 1159 1294 B1+B2 721 826 890 972 1036 1113 1146 1191 1236 1450 1540 1630 1765 Oval flange B1 490 505 555 600 645 722 767 812 857 979 1069 1159 1294 B1+B2 721 826 890 972 1036 1113 1146 1191 1236 1450 1540 1630 1765 D1 D2 Net weight [kg] D3 DIN flange Oval flange 45 53 59 71 73 95 111 115 117 141 143 165 184 40 48 54 67 68 90 107 110 112 136 139 161 180

141 109 178 110 198 120 220 134

220 134 300 220 134 300 260 159 300 260 159 300 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
146 CRN 20 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN 20-1 CRN 20-2 CRN 20-3 CRN 20-4 CRN 20-5 CRN 20-6 CRN 20-7 CRN 20-8 CRN 20-10 CRN 20-12 CRN 20-14 CRN 20-17 1.1 2.2 4 5.5 5.5 7.5 7.5 11 11 15 15 18.5 487 503 553 630 675 720 765 887 977 1067 1157 1292 B1+B2 718 824 925 1021 1066 1099 1144 1358 1448 1538 1628 1807 Oval flange B1 487 503 553 630 675 720 765 887 977 1067 1157 1292 B1+B2 718 824 925 1021 1066 1099 1144 1358 1448 1538 1628 1807 D1 D2 Net weight [kg] D3 DIN flange Oval flange 46 54 71 93 94 113 114 137 141 176 179 206 41 49 66 88 89 108 110 132 136 171 175 202

141 109 178 110 220 134

220 134 300 220 134 300 260 159 300 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161.

CRN 32 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN 32-1-1 CRN 32-1 CRN 32-2-2 CRN 32-2 CRN 32-3-2 CRN 32-3 CRN 32-4-2 CRN 32-4 CRN 32-5-2 CRN 32-5 CRN 32-6-2 CRN 32-6 CRN 32-7-2 CRN 32-7 CRN 32-8-2 CRN 32-8 CRN 32-9-2 CRN 32-9 CRN 32-10-2 CRN 32-10 CRN 32-11-2 CRN 32-11 CRN 32-12-2 CRN 32-12 1.5 2.2 3 4 5.5 5.5 7.5 7.5 11 11 11 11 15 15 15 15 18.5 18.5 18.5 18.5 22 22 22 22 505 505 575 575 666 666 715 715 895 895 965 965 1035 1035 1105 1105 1175 1175 1245 1245 1315 1315 1385 1385 B1+B2 786 826 910 947 1057 1057 1094 1094 1366 1366 1436 1436 1506 1506 1576 1576 1690 1690 1760 1760 1856 1856 1926 1926 Oval flange B1 B1+B2 D1 178 178 198 220 220 220 260 260 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 314 D2 110 110 120 134 134 134 159 159 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 D3 270 270 270 270 300 300 300 300 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 69 69 76 87 102 102 121 121 148 148 151 151 193 193 199 199 199 199 202 202 276 176 280 280 Oval flange -

For information about electrical data, see pages 160 to 161. Note: CRN 32 pumps are also available with PJE connection.

16
CRN pumps with magnetic drive (MAGdrive) 50 Hz Technical data
147 CRN 45 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN 45-1-1 CRN 45-1 CRN 45-2-2 CRN 45-2 CRN 45-3-2 CRN 45-3 CRN 45-4-2 CRN 45-4 CRN 45-5-2 CRN 45-5 CRN 45-6-2 CRN 45-6 3 4 5.5 7.5 11 11 15 15 18.5 18.5 22 22 559 559 660 639 829 829 909 909 989 989 1069 1069 Dimension [mm] DIN flange B1+B2 894 931 1051 1018 1300 1300 1380 1380 1504 1504 1610 1610 Oval flange B1 B1+B2 D1 198 220 220 260 314 314 314 314 314 314 314 314 D2 120 134 134 159 204 204 204 204 204 204 204 204 D3 270 270 300 300 350 350 350 350 350 350 350 350 Net weight [kg] DIN flange 81 92 107 121 153 153 185 195 195 195 273 273 Oval flange -

For information about electrical data, see pages 160 to 161. Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN 64-1-1 CRN 64-1 CRN 64-2-2 CRN 64-2-1 CRN 64-2 CRN 64-3-2 CRN 64-3-1 CRN 64-3 CRN 64-4-2 CRN 64-4-1 4 7.5 11 11 15 15 18.5 18.5 22 22 561 561 644 754 754 836 836 836 919 919 933 940 1115 1225 1225 1307 1351 1351 1460 1460 D1 D2 Net weight [kg] D3 DIN flange Oval flange 95 118 152 152 170 193 191 191 266 266 -

220 134 270 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 64 pumps are also available with PJE connection.

CRN 90 - MAGdrive, 50 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN 90-1-1 CRN 90-1 CRN 90-2-2 CRN 90-2 CRN 90-3-2 5.5 7.5 15 18.5 18.5 592 571 773 773 865 983 950 1244 1288 1380 D1 D2 Net weight [kg] D3 DIN flange Oval flange 111 125 177 192 197 -

220 134 300 260 159 300 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 90 pumps are also available with PJE connection.

16
CRN pumps with magnetic drive (MAGdrive) 60 Hz Technical data
148 CRN 1s - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 367 385 403 421 439 457 475 493 511 529 547 583 619 655 713 749 785 821 558 558 576 594 612 630 648 666 684 702 720 738 774 810 886 994 1030 1066 1142 Oval flange 342 342 360 378 396 414 432 450 468 486 504 522 558 594 630 688 724 760 796 533 533 551 569 587 605 623 641 659 677 695 713 749 785 861 969 1005 1041 1117 B1 B1+B2 B1 B1+B2 CRN1s-2 CRN1s-3 CRN1s-4 CRN1s-5 CRN1s-6 CRN1s-7 CRN1s-8 CRN1s-9 CRN1s-10 CRN1s-11 CRN1s-12 CRN1s-13 CRN1s-15 CRN1s-17 CRN1s-19 CRN1s-21 CRN1s-23 CRN1s-25 CRN1s-27 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 D1 Net weight [kg] D2 D3 DIN flange Oval flange 24 25 25 25 27 27 28 29 29 30 30 31 40 40 41 44 44 44 45 20 20 21 21 23 23 23 25 25 25 26 26 36 36 36 39 40 40 41

141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110

For information about electrical data, see pages 160 to 161.

CRN 1 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] B1 CRN1-2 CRN1-3 CRN1-4 CRN1-5 CRN1-6 CRN1-7 CRN1-8 CRN1-9 CRN1-10 CRN1-11 CRN1-12 CRN1-13 CRN1-15 CRN1-17 CRN1-19 CRN1-21 CRN1-23 CRN1-25 CRN1-27 0.37 0.37 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 3 3 367 367 385 403 421 439 457 475 493 511 535 569 605 641 677 713 749 790 826 Dimension [mm] DIN flange B1+B2 558 558 576 594 612 630 648 666 684 742 766 850 886 922 998 1034 1070 1125 1161 Oval flange B1 342 342 360 378 396 414 432 450 468 486 510 544 580 616 652 688 724 765 801 B1+B2 533 533 551 569 587 605 623 641 659 717 741 825 861 897 973 1009 1045 1100 1136 D1 141 141 141 141 141 141 141 141 141 141 141 178 178 178 178 178 178 198 198 D2 109 109 109 109 109 109 109 109 109 109 109 110 110 110 110 110 110 120 120 D3 Net weight [kg] DIN flange 24 25 26 26 28 28 28 37 37 37 39 41 41 42 42 43 44 54 55 Oval flange 20 20 22 22 24 24 24 33 33 33 35 36 37 38 38 39 40 50 51

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 60 Hz Technical data
149 CRN 3 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 367 385 403 421 439 463 497 515 533 551 569 605 646 682 718 754 790 558 558 576 594 612 630 694 778 796 814 872 890 926 981 1017 1053 1126 1162 Oval flange 342 342 360 378 396 414 438 472 490 508 526 544 580 621 657 693 729 765 533 533 551 569 587 605 669 753 771 789 847 865 901 956 992 1028 1101 1137 B1 B1+B2 B1 B1+B2 CRN3-2 CRN3-3 CRN3-4 CRN3-5 CRN3-6 CRN3-7 CRN3-8 CRN3-9 CRN3-10 CRN3-11 CRN3-12 CRN3-13 CRN3-15 CRN3-17 CRN3-19 CRN3-21 CRN3-23 CRN3-25 0.37 0.55 0.75 0.75 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 2.2 3 3 3 4 4 D1 Net weight [kg] D2 D3 DIN flange Oval flange 24 26 27 27 36 36 38 39 39 39 39 40 41 51 52 52 69 70 20 21 23 23 31 32 33 35 35 35 35 36 36 47 47 48 65 65

141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110 178 110 198 120 198 120 198 120 198 120 198 120

For information about electrical data, see pages 160 to 161.

CRN 5 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 367 394 421 470 497 524 551 583 610 637 664 691 558 585 652 751 818 845 872 918 945 972 1036 1063 Oval flange 342 369 396 445 472 499 526 558 585 612 639 666 533 560 627 726 793 820 847 893 920 947 1011 1038 B1 B1+B2 B1 B1+B2 CRN5-2 CRN5-3 CRN5-4 CRN5-5 CRN5-6 CRN5-7 CRN5-8 CRN5-9 CRN5-10 CRN5-11 CRN5-12 CRN5-13 CRN5-14 CRN5-15 CRN5-16 CRN5-18 CRN5-20 0.75 1.1 1.1 1.5 2.2 2.2 2.2 3 3 3 4 4 4 4 5.5 5.5 5.5 D1 D2 Net weight [kg] D3 DIN flange Oval flange 27 35 35 39 39 39 40 49 50 50 65 66 67 67 76 76 77 22 31 31 35 35 35 36 45 45 46 61 62 62 62 71 72 73

141 109 141 109 141 109 178 110 178 110 178 110 178 110 198 120 198 120 198 120 198 120 198 120

719 1089.6 694 1064.6 198 120 745 1116.6 720 1091.6 198 120

817 1208.4 792 1183.4 220 134 300 875 1266.4 850 1241.4 220 134 300 929 1320.4 904 1295.4 220 134 300

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 60 Hz Technical data
150 CRN 10 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange 443 634 Oval flange 443 634 B1 B1+B2 B1 B1+B2 CRN10-1 CRN10-2 CRN10-3 CRN10-4 CRN10-5 CRN10-6 CRN10-7 CRN10-8 CRN10-9 CRN10-10 CRN10-12 CRN10-14 CRN10-16 0.75 1.5 2.2 3 4 4 5.5 5.5 7.5 7.5 7.5 11 11 D1 D2 Net weight [kg] D3 DIN flange Oval flange 41 50 51 61 78 79 86 87 97 97 97 152 154 37 47 47 57 74 75 82 84 94 94 94 148 150

141 109

463 743.5 463 743.5 178 110 493 813.5 493 813.5 178 110 528 558 588 635 665 695 725 785 902 962 863 930 1026 1026 1056 1074 1104 1164 1373 1433 528 558 588 635 665 695 725 785 902 962 863 930 1026 1026 1056 1074 1104 1164 1373 1433 198 120 198 120 198 120

220 134 300 220 134 300 260 159 300 260 159 300 260 159 300 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161.

CRN 15 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN15-1 CRN15-2 CRN15-3 CRN15-4 CRN15-5 CRN15-6 CRN15-7 CRN15-8 CRN15-9 CRN15-10 CRN15-12 1.5 3 5.5 7.5 7.5 11 11 15 15 15 18.5 506 510 572 617 645 764 809 854 899 979 1069 B1+B2 786.5 845 963 996 1024 1235 1280 1325 1370 1450 1584 Oval flange B1 506 510 572 617 645 764 809 854 899 979 1069 B1+B2 845 963 996 1024 1235 1280 1325 1370 1450 1584 D1 D2 Net weight [kg] D3 DIN flange Oval flange 46 56 75 87 87 148 152 173 175 175 169 41 51 70 83 83 143 148 168 170 170 164

786.5 178 110 198 120

220 134 300 260 159 300 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161.

CRN 20 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN20-1 CRN20-2 CRN20-3 CRN20-4 CRN20-5 CRN20-6 CRN20-7 CRN20-8 2.2 4 7.5 11 11 15 15 18.5 508 570 740 785 830 875 887 880 949 1211 1256 1301 1346 1402 508 570 740 785 830 875 887 880 949 1211 1256 1301 1346 1402 D1 D2 Net weight [kg] D3 DIN flange Oval flange 52 76 87 146 147 170 171 163 47 71 82 141 142 165 167 159

503 823.5 503 823.5 178 110 198 120

260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161.

16
CRN pumps with magnetic drive (MAGdrive) 60 Hz Technical data
151 CRN 32 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRN32-1-1 CRN32-1 CRN32-2-2 CRN 32-2-1 CRN32-2 CRN32-3-2 CRN32-3 CRN32-4-2 CRN32-4 CRN32-5-2 CRN32-5 CRN32-6-2 CRN32-6 CRN32-7-2 CRN32-7 3 5.5 5.5 5.5 7.5 11 11 15 15 15 18.5 18.5 22 22 22 505 505 575 575 575 690 690 757 757 895 895 965 965 1035 1035 840 896 966 966 954 1161 1161 1228 1228 1366 1410 1480 1506 1576 1576 Oval flange B1+B2 B1 B1+B2 D1 D2 Net weight [kg] D3 DIN flange Oval flange 77 96 101 101 108 155 155 179 179 180 172 172 238 266 266 -

198 120

220 134 300 220 134 300 220 134 300 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 32 pumps are also available with PJE connection.

CRN 45 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN45-1-1 CRN45-1 CRN45-2-2 CRN45-2-1 CRN45-2 CRN45-3-2 CRN45-3-1 CRN45-3 CRN45-4-2 5.5 7.5 11 15 15 18.5 18.5 18.5 22 559 559 770 749 749 829 829 829 909 950 938 1241 1220 1220 1344 1344 1344 1450 D1 D2 Net weight [kg] D3 DIN flange Oval flange 106 116 160 178 178 169 169 169 268 -

220 134 300 260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 45 pumps are also available with PJE connection.

CRN 64 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN64-1-1 CRN64-1 CRN64-2-2 CRN64-2-1 CRN64-2 CRN64-3-2 7.5 11 15 18.5 22 22 561 671 644 754 754 836 940 1142 1115 1269 1295 1377 D1 D2 Net weight [kg] D3 DIN flange Oval flange 111 158 173 168 243 166 -

260 159 300 314 204 350 314 204 350 314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 64 pumps are also available with PJE connection.

16
Technical data
152 CRN 90 - MAGdrive, 60 Hz
CRN MAGdrive Pump type Motor P2 [kW] Dimension [mm] DIN flange Oval flange B1 B1+B2 B1 B1+B2 CRN90-1-1 CRN90-1 CRN90-2-2 11 15 22 702 681 773 1173 1152 1314 D1 D2 Net weight [kg] D3 DIN flange Oval flange 164 182 250 -

314 204 350 314 204 350 314 204 350

For information about electrical data, see pages 160 to 161. Note: CRN 90 pumps are also available with PJE connection.

17
CRH(N) pumps 50 Hz Technical data
MeCRH(N) 50 50 CRH(N)32 CRH(N)45 CRH(N)64-90 100 100 102 124 280 210 490 50 80 50 80 Dim. [mm] 102 102 102 124 124 124 According to specifications for CR horizontal pumps (page 59) 191 191 229 210 210 210 401 401 439
TM05 1523 3211

17. Technical data


CRH(N) pumps
Dimensional drawings

CRH(N) 1s - 90

SmCRH(N) Inlet [mm] Outlet [mm] Ref. A B AA D E F Note 40 25 102 76 165 134 299

Ref. AA is only applicable with motors 5.5 - 45 kW.

153

17
CRH(N) pumps 50 Hz Technical data
154

CRH(N) pumps
Dimensions and weights CRH(N) 1s, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)1s-2 CRH(N)1s-3 CRH(N)1s-4 CRH(N)1s-5 CRH(N)1s-6 CRH(N)1s-7 CRH(N)1s-8 CRH(N)1s-9 CRH(N)1s-10 CRH(N)1s-11 CRH(N)1s-12 CRH(N)1s-13 CRH(N)1s-15 CRH(N)1s-17 CRH(N)1s-19 CRH(N)1s-21 CRH(N)1s-23 CRH(N)1s-25 CRH(N)1s-27 CRH(N)1s-30 CRH(N)1s-33 CRH(N)1s-36 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 Dimension [mm] DIN flange B2 B1+B2 500 500 518 536 554 572 590 608 626 644 662 680 716 752 788 886 922 958 994 1048 1102 1156 309 191 309 191 327 191 345 191 363 191 381 191 399 191 417 191 435 191 453 191 471 191 489 191 525 191 561 191 597 191 655 231 691 231 727 231 763 231 817 231 871 231 925 231 D2 D3 D4 D5 E3 E4 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 Net weight [kg] DIN 24 24 25 25 26 26 26 27 27 27 28 28 30 31 31 34 35 35 38 40 41 42 DIN 21 22 22 22 23 23 23 24 24 25 25 25 27 28 28 32 32 33 36 37 38 40 CR flange CRN flange

For information about electrical data, see pages 160 to 161.

CRH(N) 1, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)1-2 CRH(N)1-3 CRH(N)1-4 CRH(N)1-5 CRH(N)1-6 CRH(N)1-7 CRH(N)1-8 CRH(N)1-9 CRH(N)1-10 CRH(N)1-11 CRH(N)1-12 CRH(N)1-13 CRH(N)1-15 CRH(N)1-17 CRH(N)1-19 CRH(N)1-21 CRH(N)1-23 CRH(N)1-25 CRH(N)1-27 CRH(N)1-30 CRH(N)1-33 CRH(N)1-36 0.37 0.37 0.37 0.37 0.37 0.37 0.55 0.55 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.2 2.2 Dimension [mm] DIN flange B2 B1+B2 500 500 518 536 554 572 590 608 626 644 708 726 762 798 834 870 906 1048 1084 1138 1192 1246 309 191 309 191 327 191 345 191 363 191 381 191 399 191 417 191 435 191 453 191 477 231 495 231 531 231 567 231 603 231 639 231 675 231 727 321 763 321 817 321 871 321 925 321 D2 D3 D4 D5 E3 E4 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 Net weight [kg] DIN 24 24 25 25 26 26 27 27 28 28 30 31 32 35 36 36 37 45 46 47 49 50 DIN 21 22 22 22 23 23 24 25 25 25 28 28 29 32 33 34 35 42 43 44 46 47 CR flange CRN flange

For information about electrical data, see pages 160 to 161.

17
CRH(N) pumps 50 Hz Technical data
155 CRH(N) 3, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)3-2 CRH(N)3-3 CRH(N)3-4 CRH(N)3-5 CRH(N)3-6 CRH(N)3-7 CRH(N)3-8 CRH(N)3-9 CRH(N)3-10 CRH(N)3-11 CRH(N)3-12 CRH(N)3-13 CRH(N)3-15 CRH(N)3-17 CRH(N)3-19 CRH(N)3-21 CRH(N)3-23 CRH(N)3-25 CRH(N)3-27 CRH(N)3-29 CRH(N)3-31 CRH(N)3-33 CRH(N)3-36 0.37 0.37 0.37 0.37 0.55 0.55 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 3 3 3 Dimension [mm] DIN flange B2 B1+B2 500 500 518 536 554 572 636 654 672 690 708 726 762 904 940 976 1012 1048 1084 1120 1175 1211 1265 309 191 309 191 327 191 345 191 363 191 381 191 405 231 423 231 441 231 459 231 477 231 495 231 531 231 583 321 619 321 655 321 691 321 727 321 763 321 799 321 840 335 876 335 930 335 D2 D3 D4 D5 E3 E4 Net weight [kg] DIN 24 24 25 25 26 27 29 29 30 32 33 33 34 42 43 44 45 46 46 47 54 55 56 DIN 21 22 22 22 23 24 26 27 27 30 30 31 32 39 40 41 42 42 43 44 51 52 53 CR flange CRN flange

109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 71 63 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 109 80 54 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 120 100 34 120 100 34 120 100 34

For information about electrical data, see pages 160 to 161.

CRH(N) 5, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)5-2 CRH(N)5-3 CRH(N)5-4 CRH(N)5-5 CRH(N)5-6 CRH(N)5-7 CRH(N)5-8 CRH(N)5-9 CRH(N)5-10 CRH(N)5-11 CRH(N)5-12 CRH(N)5-13 CRH(N)5-14 CRH(N)5-15 CRH(N)5-16 CRH(N)5-18 CRH(N)5-20 CRH(N)5-22 CRH(N)5-24 CRH(N)5-26 CRH(N)5-29 CRH(N)5-32 CRH(N)5-36 0.37 0.55 0.55 0.75 1.1 1.1 1.1 1.5 1.5 2.2 2.2 2.2 2.2 2.2 2.2 3 3 4 4 4 4 5.5 5.5 Dimension [mm] DIN flange B2 B1+B2 500 527 554 627 654 681 708 841 868 895 922 949 976 1003 1030 1103 1157 1248 1302 1356 1437 1566 1674 309 191 336 191 363 191 396 231 423 231 450 231 477 231 520 321 547 321 574 321 601 321 628 321 655 321 682 321 709 321 768 335 822 335 876 372 930 372 984 372 1065 372 1175 391 1283 391 D2 D3 D4 D5 E3 E4 Net weight [kg] DIN 24 26 26 28 31 32 32 40 40 42 42 43 43 44 45 52 53 63 64 66 67 83 86 DIN 21 23 23 26 29 29 30 37 38 39 39 40 40 41 41 49 50 60 62 63 64 80 82 CR flange CRN flange

109 71 63 109 71 63 109 71 63 109 80 54 109 80 54 109 80 54 109 80 54 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 110 90 44 120 100 34 120 100 34 134 112 22 134 112 22 134 112 22 134 112 22 134 132 2 134 132 2

1294 1434 1402 1542

For information about electrical data, see pages 160 to 161.

17
CRH(N) pumps 50 Hz Technical data
156 CRH(N) 10, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)10-1 CRH(N)10-2 CRH(N)10-3 CRH(N)10-4 CRH(N)10-5 CRH(N)10-6 CRH(N)10-7 CRH(N)10-8 CRH(N)10-9 CRH(N)10-10 CRH(N)10-12 CRH(N)10-14 CRH(N)10-16 CRH(N)10-18 CRH(N)10-20 CRH(N)10-22 0.37 0.75 1.1 1.5 2.2 2.2 3 3 3 4 4 5.5 5.5 7.5 7.5 7.5 Dimension [mm] DIN flange B2 B1+B2 605 661 695 815 845 905 949 979 1009 1188 1248 1327 1387 1435 1495 1555 414 191 430 231 464 231 494 321 524 321 584 321 614 335 644 335 674 335 816 372 876 372 936 391 996 391 1056 379 1116 379 1176 379 D2 D3 D4 D5 E3 E4 Net weight [kg] DIN 58 60 63 71 73 74 81 82 83 93 95 118 120 133 136 138 DIN 52 54 58 66 68 69 76 77 78 88 90 113 115 128 130 132 CR flange CRN flange

109 71 139 109 80 130 109 80 130 109 90 120 110 90 120 110 90 120 120 100 110 120 100 110 120 100 110 134 112 98 134 112 98 134 132 78 134 132 78 159 132 78 159 132 78 159 132 78

1055 1195 1115 1255 1125 1303 1185 1363 1245 1423

For information about electrical data, see pages 160 to 161.

CRH(N) 15, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)15-1 CRH(N)15-2 CRH(N)15-3 CRH(N)15-4 CRH(N)15-5 CRH(N)15-6 CRH(N)15-7 CRH(N)15-8 CRH(N)15-9 CRH(N)15-10 CRH(N)15-12 CRH(N)15-14 CRH(N)15-17 1.1 2.2 3 4 4 5.5 5.5 7.5 7.5 11 11 11 11 Dimension [mm] DIN flange B2 B1+B2 673 689 843 925 970 1063 1108 1141 1186 1436 1526 1616 1751 442 231 458 231 508 335 553 372 598 372 672 391 717 391 762 379 807 379 965 471 1055 471 1145 471 1280 471 D2 D3 D4 D5 E3 E4 Net weight [kg] DIN 62 70 77 88 89 111 113 125 127 169 173 177 195 DIN 57 65 73 83 85 107 108 121 122 165 168 171 189 CR flange CRN flange

109 80 130 110 90 120 120 100 110 134 112 98 134 112 98

134 132 78 140 791 931 134 132 78 140 836 159 132 78 178 831 159 132 78 178 876 204 160 50 210 1103 204 160 50 210 1193 204 160 50 210 1283 204 160 50 210 1418

For information about electrical data, see pages 160 to 161.

17
CRH(N) pumps 50 Hz Technical data
157 CRH(N) 20, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)20-1 CRH(N)20-2 CRH(N)20-3 CRH(N)20-4 CRH(N)20-5 CRH(N)20-6 CRH(N)20-7 CRH(N)20-8 CRH(N)20-10 CRH(N)20-12 CRH(N)20-14 CRH(N)20-17 1.1 2.2 4 5.5 5.5 7.5 7.5 11 11 15 15 18.5 Dimension [mm] DIN flange B2 B1+B2 740 846 947 1040 1085 1118 1163 1413 1503 1593 1683 1892 509 231 525 321 575 372 649 391 694 391 739 379 784 379 942 471 1032 471 1122 471 1212 471 1347 545 D2 D3 D4 D5 E3 768 813 808 E4 908 953 986 Net weight [kg] DIN 62 70 86 108 110 122 123 166 169 186 190 208 DIN 57 65 82 104 105 117 119 161 165 181 184 202 CR flange CRN flange

109 80 130 110 90 120 134 112 98 134 132 78 134 132 78 159 132 78 159 132 78 204 160 50

853 1031 1080 1290

204 160 50 210 1170 1380 204 160 50 210 1260 1470 204 160 50 210 1350 1560 204 180 30 1485 1739

For information about electrical data, see pages 160 to 161.

CRH(N) 32, 50 Hz
CR Pump type Motor P2 [kW] B1 CRH(N)32-1-1 CRH(N)32-1 CRH(N)32-2-2 CRH(N)32-2 CRH(N)32-3-2 CRH(N)32-3 CRH(N)32-4-2 CRH(N)32-4 CRH(N)32-5-2 CRH(N)32-5 CRH(N)32-6-2 CRH(N)32-6 CRH(N)32-7-2 CRH(N)32-7 CRH(N)32-8-2 CRH(N)32-8 CRH(N)32-9-2 CRH(N)32-9 CRH(N)32-10-2 CRH(N)32-10 CRH(N)32-11-2 CRH(N)32-11 CRH(N)32-12-2 CRH(N)32-12 CRH(N)32-13-2 CRH(N)32-13 CRH(N)32-14-2 CRH(N)32-14 1.5 2.2 3 4 5.5 5.5 7.5 7.5 11 11 11 11 15 15 15 15 18.5 18.5 18.5 18.5 22 22 22 22 30 30 30 30 Dimension [mm] DIN flange B2 B1+B2 854 854 938 975 1064 1064 1134 1134 1394 1394 1464 1464 1534 1534 1604 1604 1718 1718 1788 1788 1884 1884 1954 1954 2093 2093 2163 2163 533 321 533 321 603 335 603 372 673 391 673 391 743 391 743 391 923 471 923 471 993 471 993 471 1063 471 1063 471 1133 471 1133 471 1203 515 1203 515 1273 515 1273 515 1343 541 1343 541 1413 541 1413 541 1483 610 1483 610 1553 610 1553 610 D2 D3 D4 D5 E3 792 792 812 812 E4 932 932 990 990 Net weight [kg] DIN 81 82 90 99 114 114 129 129 176 176 179 179 195 195 201 201 217 217 220 220 238 238 241 241 347 347 350 350 DIN 77 77 86 95 109 109 124 124 171 171 174 174 190 190 196 196 213 213 216 216 233 233 237 237 342 342 345 345 CR flange CRN flange

110 90 120 110 90 120 120 100 110 134 112 98 134 132 78 134 132 78 159 132 78 159 132 78 204 160 50

1061 1271

204 160 50 210 1061 1271 204 160 50 210 1131 1341 204 160 50 210 1131 1341 204 160 50 210 1201 1411 204 160 50 210 1201 1411 204 160 50 210 1271 1481 204 160 50 210 1271 1481 204 160 50 254 1341 1595 204 160 50 254 1341 1595 204 160 50 254 1411 1665 204 160 50 254 1411 1665 204 180 30 241 1494 1735 204 180 30 241 1494 1735 204 180 30 241 1564 1805 204 180 30 241 1564 1805 300 200 10 305 1675 1980 300 200 10 305 1675 1980 300 200 10 305 1745 2050 300 200 10 305 1745 2050

For information about electrical data, see pages 160 to 161.

17
CRH(N) pumps 50 Hz Technical data
158 CRH(N) 45, 50 Hz
CR Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRH(N)45-1-1 CRH(N)45-1 CRH(N)45-2-2 CRH(N)45-2 CRH(N)45-3-2 CRH(N)45-3 CRH(N)45-4-2 CRH(N)45-4 CRH(N)45-5-2 CRH(N)45-5 CRH(N)45-6-2 CRH(N)45-6 CRH(N)45-7-2 CRH(N)45-7 CRH(N)45-8-2 CRH(N)45-8 CRH(N)45-9-2 CRH(N)45-9 CRH(N)45-10-2 CRH(N)45-10 CRH(N)45-11-2 CRH(N)45-11 CRH(N)45-12-2 CRH(N)45-12 CRH(N)45-13-2 3 4 5.5 7.5 11 11 15 15 18.5 18.5 22 22 30 30 30 30 30 37 37 37 45 45 45 45 45 549 549 629 629 819 819 899 899 979 979 1059 1059 1139 1139 1219 1219 1299 1299 1379 1379 1465 1459 1539 1539 1619 B2 B1+B2 884 921 1020 1008 1290 1290 1370 1370 1494 1494 1600 1600 1749 1749 1829 1829 1909 1966 2046 2046 2174 2168 2248 2248 2328 D2 120 134 134 159 204 204 204 204 204 204 D3 D4 D5 154 142 122 122 94 94 94 94 94 94 E3 748 698 E4 888 876 Net weight [kg] DIN 99 108 123 135 182 182 199 199 216 216 236 236 343 343 347 347 351 381 386 386 474 474 479 479 483 DIN 101 110 125 137 184 184 201 201 218 218 238 238 345 345 349 349 353 383 387 387 476 476 480 480 485 CR flange CRN flange

957 1167 957 1167 1037 1247 1037 1247 1117 1371 1117 1371 1210 1451 1210 1451 1331 1636 1331 1636 1411 1716 1411 1716 1491 1796 1489 1794 1569 1874 1569 1874 1673 1959 1667 1953 1747 2033 1747 2033 1827 2113

204 180 74 204 180 74 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 325 225 29 325 225 29 325 225 29 325 225 29 325 225 29

For information about electrical data, see pages 160 to 161.

CRH(N) 64, 50 Hz
CR Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRH(N)64-1-1 CRH(N)64-1 CRH(N)64-2-2 CRH(N)64-2-1 CRH(N)64-2 CRH(N)64-3-2 CRH(N)64-3-1 CRH(N)64-3 CRH(N)64-4-2 CRH(N)64-4-1 CRH(N)64-4 CRH(N)64-5-2 CRH(N)64-5-1 CRH(N)64-5 CRH(N)64-6-2 CRH(N)64-6-1 CRH(N)64-6 CRH(N)64-7-2 CRH(N)64-7-1 CRH(N)64-7 CRH(N)64-8-2 CRH(N)64-8-1 4 5.5 7.5 11 11 15 15 18.5 18.5 22 22 30 30 30 30 37 37 37 37 45 45 45 580 580 662 772 772 854 854 854 936 936 936 1018 1018 1018 1100 1100 1100 1182 1182 1188 1270 1270 B2 B1+B2 952 971 1041 1243 1243 1325 1325 1369 1451 1477 1477 1628 1628 1628 1710 1767 1767 1849 1849 1897 1979 1979 D2 D3 D4 D5 E3 699 731 E4 839 909 Net weight [kg] DIN 121 133 149 193 193 210 210 223 228 242 242 348 348 348 354 384 384 389 389 473 478 478 DIN 114 125 142 186 186 203 203 216 221 234 234 341 341 341 348 378 378 382 382 467 471 471 CR flange CRN flange

134 112 142 134 132 122 159 132 122 204 160 94 204 204 204 204 204 94 94 94 94 94

910 1120 910 1120 992 1202 992 1202 992 1246 1074 1328 1087 1328 1087 1328 1210 1515 1210 1515 1210 1515 1292 1597 1292 1597 1292 1597 1374 1679 1374 1679 1378 1664 1478 1764 1478 1764

204 180 74 204 180 74 204 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 300 200 54 325 225 29 325 225 29 325 225 29

For information about electrical data, see pages 160 to 161.

17
CRH(N) pumps 50 Hz Technical data
159 CRH(N) 90, 50 Hz
CR Pump type Motor P2 [kW] Dimension [mm] DIN flange B1 CRH(N)90-1-1 CRH(N)90-1 CRH(N)90-2-2 CRH(N)90-2 CRH(N)90-3-2 CRH(N)90-3 CRH(N)90-4-2 CRH(N)90-4 CRH(N)90-5-2 CRH(N)90-5 CRH(N)90-6-2 CRH(N)90-6 5.5 7.5 11 15 18.5 22 30 30 37 37 45 45 590 590 792 792 884 884 976 976 1068 1068 1166 1166 B2 B1+B2 981 969 1263 1263 1399 1425 1586 1586 1735 1735 1875 1875 D2 134 159 204 204 204 204 D3 D4 D5 122 122 94 94 94 74 E3 709 659 E4 849 969 Net weight [kg] DIN 133 145 193 206 224 238 345 345 382 382 471 471 DIN 127 139 187 200 218 232 339 339 376 376 466 466 CR flange CRN flange

930 1263 930 1263 1022 1399 1035 1425 1168 1586 1168 1586 1258 1735 1258 1735 1374 1875 1374 1875

300 200 54 300 200 54 300 200 54 300 200 54 325 225 29 325 225 29

For information about electrical data, see pages 160 to 161.

18
18. Motor data
Standard 2-pole motors for CR, CRI, CRN, 50 Hz
Motor P2 [kW] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 Frame size 71 71 80 80 90 90 100 112 132 132 160 160 160 180 Standard voltage [V] I 1/1 [A] Cos 1/1 [%] Istart Speed [min-1]

CR, CRI, CRN, CRT,

380-415 /660-690Y 41.5-38.5/23.8-22.8 0.91-0.89 91.9-92.8

311-343/179-203

2930-2940 Siemens

Standard 4-pole motors for CR, CRI, CRN, 50 Hz


Motor P2 [kW] 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 Frame size 71 71 80 80 90 90 100 100 112 132 132 160 160 Standard voltage [V] 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 220-240/380-415Y 380-415 380-415 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y 380-415/660-690Y I 1/1 [A] 1.48/0.85 1.90/1.10 2.60/1.50 3.30/1.90 5.00/2.90 6.40/3.70 9.20/5.30 7.40 8.90 11.2-10.4/6.50-6.25 15.2-14.0/8.70-8.40 21.6-20.4/12.4-12.0 29.0-28.0/16.8-16.4 Cos 1/1 [%] 71-72 71 77 78 78 80 83.5 85 86.5-87 89.0-90.0 89.5-90.5 91.0-92.0 92.6-92.0 Speed [min-1] MG 0.75-0.65 0.77-0.67 0.79-0.70 0.79-0.70 0.78-0.71 0.80-0.74 0.79-0.76 0.79-0.69 0.82-0.76 0.86-0.84 0.87-0.85 0.88-0.84 0.87-0.84 1400-1420 1400-1420 1390-1410 1390-1410 1440-1445 1440-1450 1440-1450 1440-1450 1450-1455 1440-1450 1440-1450 1460-1470 1460-1470

160

TM03 1711 2805

TM03 1710 2805

30 37 45 55 75

200 200 225 250 280

380-415 /660-690Y 380-415 /660-690Y 380-415 /660-690Y 380-415 /660-690Y 380-415 /660-690Y

53.0/30.5 64.0/37.0 77.0/44.5 93.0/54.0 128/74.0

0.88-0.88 0.89-0.89 0.89-0.89 0.90-0.90 0.89-0.89

93.5 94.0 95.0 95.5 95.0

371/214 461/266 562/325 632/367 896-832/518-481

2960 2960 2965 2975 2975

TM03 1711 2805

Motor data

MG 220-240 /380-415Y 1.7/1.0 0.80-0.70 78.5 220-240 /380-415Y 2.5/1.4 0.80-0.70 80.0 220-240 /380-415Y 3.3/1.9 0.81-0.71 81.0 220-240 /380-415Y 4.5/2.6 0.84-0.76 82.8 220-240 /380-415Y 5.5/3.2 0.87-0.82 85.5 380-415 4.5-4.5 0.89-0.87 87.5 380-415 6.3-6.3 0.87-0.82 87.5 380-415 8.0-8.0 0.88-0.84 89.0 380-415 11.2-11.2 0.88-0.84 90.0 380-415 /660-690Y 14.8-13.6/8.5-8.1 0.89-0.88 89.5-90.5 380-415 /660-690Y 21.2-19.6/12.2-11.6 0.90-0.88 90.0-88.0 380-415 /660-690Y 28.5-26.0/16.2-15.6 0.91-0.90 91.0-92.3 380-415 /660-690Y 35.0-32.0/20.0-19.2 0.91-0.90 91.6-92.6 8.5-9.2/4.9-5.3 12-13/6.9-7.5 19.1-20.5/11.0-11.8 28.5-31.5/16.3-17.9 46.3-50.7/26.8-29.3 37.8-42.3 52.9-58.0 89.6-98.4 120-131 115-124/66.3-73.7 140-153/80.5-90.5 188-203/107-122 249-272/142-163 2850-2880 2830-2850 2840-2870 2820-2860 2890-2910 2890-2910 2900-2920 2910-2930 2910-2930 2920-2930 2920-2940 2920-2940 2920-2940

CR, CRI, CRN, CRT,

18
Motor data
MG Siemens MG
TM03 1711 2805 TM03 1710 2805 TM03 1711 2805

Standard 2-pole motors for CR, CRI, CRN, 60 Hz


Motor P2 Frame [kW] size 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 71 71 80 80 90 90 100 112 132 132 160 160 160 180 Standard voltage [V] I 1/1 [A] Cos 1/1 [%] Istart Speed [min-1] 3410-3470 3390-3460 3400-3470 3390-3460 3470-3530 3470-3530 3430-3530 3510-3540 3510-3540 3480-3510 3500-3550 3500-3550 3500-3550 3500-3550

220-255/380-440Y 1.5-1.4/0.9-0.8 0.85-0.76 79.0-80.0 220-255/380-440Y 2.2-2.1/1.3-1.2 0.85-0.76 81.5-83.0 220-255/380-440Y 2.9-2.7/1.7-1.6 0.86-0.78 83.0-85.0 220-255/380-440Y 4.2-3.9/2.5-2.2 0.88-0.82 82.0-84.5 220-277/380-480Y 5.4-4.7/3.1-2.7 0.90-0.81 84.0-85.0 380-480 4.5-3.7 0.91-0.85 84.0-87.0 380-480 6.2-5.7 0.89-0.84 84.0-87.5 380-480 7.8-6.8 0.90-0.82 88.0-89.5 380-480 10.8-9.5 0.90-0.82 89.0-89.0 380-480/660-690Y 14.4-12.0/8.3-8.1 0.91-0.85 90.0-91.5 380-480/660-690Y 21.2-17.2/12.2-11.6 0.91-0.87 90.0-92.5 380-480/660-690Y 29.0-22.8/16.6-15.8 0.92-0.89 90.0-92.5 380-480/660-690Y 35.0-28.0/20.2-19.2 0.92-0.89 90.5-93.0 380-480/660-690Y 42.0-33.5/24.2-22.8 0.92-0.89 90.0-92.5 380-480/660-690Y 55.0-45.0/31.5-30.0 0.90-0.86 92.5-93.5 380-480/660-690Y 67.0-54.0/38.5-37.0 0.90-0.87 93.0-94.0 380-480/660-690Y 81.0-65.0/46.5-44.0 0.90-0.87 94.5-95.0 380-480 /660-690Y 97.0-79.0/56.0-53.0 0.91-0.88 94.5-95.0 380-480 /660-690Y 134-108/77.0-73.0 0.90-0.87 95.0-95.5

8.3-9.4/4.8-4.9 10.8-12.3/6.3-7.2 17.1-20.0/9.9-11.5 25.6-30.4/14.9-17.5 41.7-49.4/24.2-28.4 34.7-40.7 49.6-62.2 79.6-102 108-138 97.9-126/56.4-85.1 123-153/70.8-103 168-203/96.3-141 214-272/123-186 273-348/157-237

30 37 45 55 75

200 200 225 250 280

358-360/252-240 442-448/254-307 543-559/312-378 621-632/358-424 871-864/501-584

3540-3565 3540-3565 3545-3570 3565-3580 3565-3580

Standard 4-pole motors for CR, CRI, CRN, 60 Hz


Motor P2 [kW] 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 Frame size 71 71 80 80 90 90 100 100 112 132 132 160 160 Standard voltage [V] 220-255 /380-440Y 220-255 /380-440Y 220-255 /380-440Y 220-255 /380-440Y 220-277 /380-480Y 220-277 /380-480Y 220-277 /380-480Y 380-480 380-480 380-480 /660-690Y 380-480 /660-690Y 380-480 /660-690Y 380-480 /660-690Y I 1/1 [A] 1.21/0.70 1.72/0.99 2.40/1.40 3.10/1.80 4.75-4.50/2.75-2.60 6.30-5.70/3.65-3.30 9.00-7.80/5.20-4.50 7.10-6.75 8.60-7.70 10.8-9.30/6.25-6.10 14.4-12.4/8.30-8.20 21.0-17.8/12.0-11.8 29.0-24.2/16.6-16.4 Cos 1/1 [%] 69-69 73-74 77-80 77-81 78-80 79-81 83-85 84-85 87-89 89.5-91.0 90.5-92.0 91.4-93.0 91.7-93.2 Speed [min-1] 1680-1720 1680-1720 1660-1710 1660-1710 1720-1750 1720-1750 1720-1750 1720-1750 1740-1755 1750-1770 1750-1770 1750-1770 1750-1770

0.80-0.69 0.82-0.72 0.83-0.75 0.84-0.76 0.82-0.67 0.83-0.73 0.80-0.70 0.80-0.70 0.85-0.73 0.89-0.81 0.90-0.82 0.90-0.83 0.89-0.83

161

19
19. Pumped liquids
Thin, non-explosive liquids, not containing solid particles or fibres. The liquid must not chemically attack the pump materials. When pumping liquids with a density and/or viscosity higher than that of water, use oversized motors, if required. Whether a pump is suitable for a particular liquid depends on a number of factors of which the most important are the chloride content, pH value, temperature and content of chemicals, oils, etc. Please note that aggressive liquids, such as sea water and some acids, may attack or dissolve the protective oxide film of the stainless steel and thus cause corrosion. CR(E), CRI(E) CR(E), CRI(E) pumps are suitable for non-corrosive liquids. Use CR(E), CRI(E) pumps for liquid transfer, circulation and pressure boosting of cold or hot clean water. CRN(E) CRN(E) pumps are suitable for industrial liquids. Use CRN(E) pumps in systems where all parts in contact with the liquid must be made of high-grade stainless steel. CRT(E) For saline or chloride-containing liquids such as sea water or for oxidising agents such as hypochlorites, Grundfos offers CRT(E) pumps made of titanium. See the separate data booklet on CRT(E) available on www.Grundfos.com (WebCAPS).

CR, CRI, CRN, CRT,

Pumped liquids
162

CR, CRI, CRN, CRT,

19
D E F H 1 2 3 4 Often with additives. The density and/or viscosity differ from that/those of water. Take this factor into account when calculating motor output and pump performance. Pump selection depends on many factors. Contact Grundfos. Risk of crystallisation/precipitation in shaft seal. Highly inflammable liquid. Combustible liquid. Insoluble in water. Low self-ignition point.

A number of typical liquids are listed below. Other pump versions may be applicable, but those stated in the list are considered to be the best choices. The table is intended as a general guide only and cannot replace actual testing of the pumped liquids and pump materials under specific working conditions. However, use the list with some caution. Factors such as those mentioned below may affect the chemical resistance of a specific pump version: concentration of the pumped liquid liquid temperature pressure. Take safety precautions when pumping dangerous liquids.

Pumped liquid Acetic acid Acetone Alkaline degreasing agent Ammonium bicarbonate Ammonium hydroxide Aviation fuel Benzoic acid Boiler water Calcareous water Calcium acetate (as coolant with inhibitor) Calcium hydroxide Chloride-containing water Chromic acid Citric acid Completely desalinated water (demineralised water) Condensate Copper sulphate Corn oil Diesel oil Domestic hot water (potable water) Ethanol (ethyl alcohol) Ethylene glycol Formic acid Glycerine (glycerol) Hydraulic oil (mineral) Hydraulic oil (synthetic) Isopropyl alcohol Lactic acid Linoleic acid Methanol (methyl alcohol) Motor oil Naphthalene Nitric acid Oil-containing water Olive oil

Chemical formula CH3COOH CH3COCH3

Note 1, F D, F

Liquid concentration, liquid temperature 5 %, +20 C 100 %, +20 C 20 %, +30 C 20 %, +40 C 100 %, +20 C 0.5 %, +20 C < +120 C +120 C to +180 C < +90 C 30 %, +50 C Saturated solution, +50 C < +30 C, max. 500 ppm 1 %, +20 C 5 %, +40 C +120 C +120 C 10 %, +50 C 100 %, +80 C 100 %, +20 C < +120 C 100 %, +20 C 50 %, +50 C 5 %, +20 C 50 %, +50 C 100 %, +100 C 100 %, +100 C 100 %, +20 C 10 %, +20 C 100 %, +20 C 100 %, +20 C 100 %, +80 C 100 %, +80 C 1 %, +20 C < +100 C 100 %, +80 C

CR(E), CRI(E) HQQE HQQE HQBV HQQE HQQE HQQE HQQE HQQE HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE HQQV HQQE HQQV HQQV HQQV HQQV

CRN(E) HQQE HQQE HQQE HQQV HQQE HQQV HQQE HQQE HQQE HQQE HQQV HQQE -

NH4HCO 3 NH4OH C6H5COOH

E 1, 3, 4, F H F -

Ca(CH3COO)2 Ca (OH)2

D, E E F

H2CrO4 HOC(CH2CO2H)2COOH

H H -

CuSO4

E D, E, 3 2, 3, 4, F -

C2H5OH HOCH2CH2OH HCOOH OHCH2CH(OH)CH2OH

1, F D, E D, E E, 2, 3 E, 2, 3

CH3CHOHCH3 CH3CH(OH)COOH C17H31COOH CH3OH C10H8 HNO3

1, F E, H E, 3 1, F E, 2, 3 E, H F D, E, 3

163

Pumped liquids

List of pumped liquids

Notes

19
Pumped liquids
164
Pumped liquid Oxalic acid Ozone-containing water Peanut oil Petrol Phosphoric acid Propanol Propylene glycol Potassium carbonate Potassium formate (as coolant with inhibitor) Potassium hydroxide Potassium permanganate Rape seed oil Salicylic acid Silicone oil Sodium bicarbonate Sodium chloride (as coolant) Sodium hydroxide Sodium hypochlorite Sodium nitrate Sodium phosphate Sodium sulphate Softened water Soya oil Sulphuric acid Sulphurous acid Unsalted swimming-pool water H2SO4 H2SO3 NaHCO3 NaCl NaOH NaOCl NaNO3 Na3PO4 Na2SO4 C6H4(OH)COOH H3PO4 C3H7OH CH3CH(OH)CH2OH K2CO3 KOOCH KOH KMnO4 Chemical formula (COOH)2 (O3) Note H D, E, 3 1, 3, 4, F E 1, F D, E E D, E E D, E, 3 H E, 3 E D, E E F E E, H E, H D, E, 3 F -

CR, CRI, CRN, CRT,

Liquid concentration, liquid temperature 1 %, +20 C < +100 C 100 %, +80 C 100 %, +20 C 20 %, +20 C 100 %, +20 C 50 %, +90 C 20 %, +50 C 30 %, +50 C 20 %, +50 C 5 %, +20 C 100 %, +80 C 0.1 %, +20 C 100 % 10 %, +60 C 30 %, < +5 C, pH > 8 20 %, +50 C 0.1 %, +20 C 10 %, +60 C 10 %, +60 C 10 %, +60 C < +120 C 100 %, +80 C 1 %, +20 C 1 %, +20 C Approx. 2 ppm free chlorine (Cl2)

CR(E), CRI(E) HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE HQQV HQQE

CRN(E) HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQV HQQE HQQE HQQE HQQE HQQV HQQE -

CR, CRI, CRN, CRT,

20
Further product documentation
165

20. Further product documentation


WebCAPS
WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings.

Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc.

Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc.

Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.

20
Further product documentation
Sizing
0 1

CR, CRI, CRN, CRT,

This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc.

Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: .dxf, wireframe drawings .dwg, wireframe drawings. 3-dimensional drawings: .dwg, wireframe drawings (without surfaces) .stp, solid drawings (with surfaces) .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year.

Fig. 94 WinCAPS CD-ROM

166

167

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

96486346 1011
Repl. 96486346 0509

GB
The name Grundfos, the Grundfos logo, and the payoff BeThinkInnovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

ECM: 1082794

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00 www.grundfos.com

Вам также может понравиться