Safety Precautions
.................................................... 2. Exploded View/(Cabinet &Chassis) ....................9
Specifications ............................................ 3 Printed Circuit Boards ................................. 11
.
Circuit Description ..................................... 4 Electrical Parts List .......................................15
Block Diagram ............................................ 5 IC’s Lead & Identifications ..........................18
Wiring Diagram .......................................... 6 Schematic Diagrams .....................................19
Troubleshooting ......................................... 7 Transistors Lead &Identifications ..................23
Mechanical parts & List. ................................. 8

* s
8 Shervvood
SAFETY PRECAUTIONS

WARNING
Before servicing this unit, familiarize yourself with the following precautions:

1. Many electrical and mechanical parts in thìs exposed metal parts of the cabinet, such as
chassìs have special safety characteristics that terminals, screw heads, and metal overlays,
often pass unnoticed and the protection to be sure the selt is safe to operate danger of
afforded by them cannot necessarily be electrical shock. Plug the AC line cord directly
obtained by using replacement components into a 120 V AC outlet (120 V AC version only).
rated for higher voltage, wattage, etc. ( Do not use a line isolation transformer
Replacement parts that have these special during this check.) Be sure your AC voltmeter
safety characteristics are identified in this has a sensitivity of 5000 <I per volt or greater.
manual and its supplements: electrical Then connect a 1500 61 10 watt resistor,
components having such features are paralleled by a’ 0.15 pF 150 V AC capacitor,
identified by A in the schematic diagram between a known good earth ground (such as
and the parts list. a water pipe, or conduit) and the exposed
metalic is parts, one at a time. Measure the
Before replacing any of these components, AC voltage across the combination of a 1500
read the parts list in this manual carefully. The Q resìstor and a 0.15 pF capacitar. Reverse the
use of substitute replacement parts that do AC plug at the AC outlet and repeat AC
not have the same safety characteristics as voltage measurements for each exposed
specífied in the parts list may create shock, metalic part. Voltagê measured must not
fire, or other hazards. exceed 0.75V RMS. This corresponds to 0.2
mA AC. Any value exceeding this limit
2. Before returning the set to the customer, constitutes a potential shock hazard and must
always do an AC leakage current check on the be corrected immediately.

.
At 5000 Q per volt or greater sensitivity,
the reading should not exceed 0.75 V.

AC Voltmeter (

Good earlh ground, such as


a wa!er pipe or co&&

AC Oullet
II 7
0.15 pF 15OV AC.

Place the probe on each exposed metalic part.