Вы находитесь на странице: 1из 1

101-D-0004

WASH WATER BREAK TANK

41
40
39

41
40

TRIM: PRW-101015601-103CS1P
/ LPN-101015601-101CS1P
INSULATION: P

0-50%

39

SPLIT RANGE

38

PY
0012

50%-100%

PV
0012 B

1"

1"-LPN-101015001-101CS1P-N

27

FC
CL300

3607

3/4"

34

33

3/4"

3/4"
1-1/2"G3"
14.10

1/4"

32

NC

31
29

30

FB
NOTE 1 LO

0.2%

4"-LPF-101015302-101CH2F-N

NOTE 1

02

3/4"

PZV
0003 A

4"x3"

NOTE 7

29

02

3"x1-1/2"

NOTE 2

LO
FB

3/4"
1-1/2"G3"
14.10

28

27

PZV
0003 B

3/4" V
26

4"x3"

NOTE 7

3"x1-1/2"
24

02

02

CL300

25

3/4"

02

LC
FB
NOTE 1

23

LO
FB
NOTE 1
3"-PRW-101015006-101CS1P-N

LV
0008
+

18

3"x1-1/2"

3"-WST-101015001-101CS1P-N
17

3/4"

16

1-1/2" 3"x1-1/2"
FC
CL300

3/4"

02
LY
0008

3"-WST-101015001-101CS1P-P

HIGH LEVEL
OVERRIDE
LC
0008 B

LC
0008 A

H
L

ZC
0010

LI
0032

E1

30

3/4"

PI
0064

UC

HPT
3/4"-PRW-101015015-101CS1P-N

LL

02

24

3/4"

02

22
21
20

L3B

18

LG
0031

MIN.

L3A

CL300

3569

3/4"

3"-WST-101015001-101CS1P-N

3
2
1

FC
CL300

8" ID

02

4"

A1

11

PIPING INST.
2"

02
10

NC

3/4" D
02

INST.
PIPING

2"

02

1300 mm

1/4"

3"-BFW-101015301-101CS1P-P

12

4"-PRW-101015002-101CS1P-P

4"-PRW-101015002-101CS1P-P

02

3/4"-PRW-101015011-101CS1P-N

02

8
7
6
5
4

3/4"-OSW-101015304-101CS1P-N

02
02

1"x3/4" 3/4" 1"x3/4"


1

NC
OSW

02

22-DEC-2010

AFC

AFC: APPROVED FOR CONSTRUCTION

JGT / STG

AVS / HPR

HS

STRIPPED SOUR WATER

01

18-MAY-2010

AFC

AFC: APPROVED FOR CONSTRUCTION

IRG / FCB

RDP / HPR

HS

FROM B.L.

00

23-DEC-2009

IFD

IFD: ISSUED FOR DESIGN

MCG / FCB

RDP / HPR

HS

PREPARED BY

CHECKED BY

DS101-TRJR-480040
3399

REV

1- EACH INSTRUMENT TAG NUMBER IS PREFIXED BY 101 (EX 101-TT-0001). THIS DRAWING IS VALID FOR TWIN LP HDS: UNITS 101 AND 102.
2- FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWINGS SA-JER-DSAAA-TRJR-480001 THROUGH SA-JER-DSAAA-TRJR-480022.

HOLDS

3- ALL LINES CONNECTED TO OSW DRAINS SYSTEMS SHALL BE GRAVITY FLOW DESIGNED.

1,2,3,4 - DELETED.

4- DRAIN VALVE ON EQUIPMENT AND/OR PIPING SHALL BE INSTALLED FLANGE O FLANGE OR AT MINIMUM DISTANCE FROM THE EQUIPMENT/PIPING TO BE DRAINED.
5- ALL LINES CONNECTED TO OSW DRAINS SYSTEMS SHALL BE GRAVITY FLOW DESIGNED.

NOTES
02

mm
mm
barg
C
barg
C

101-D-0004
VERTICAL
3040.0
990.0
1.70
74.00
15.00
150.00

1- BLOCK VALVE SHALL BE INSTALLED WITH STEM IN OR BELOW THE HORIZONTAL POSITION.
2- MECHANICAL LINK.
3- MAKE CONNECTION ON TOP OF PIPE.
4- DES PRESS: PRESSURE: 15 barg, AND HALF VACUUM (HV) AT 150 C.
5- ENSURE THAT NOZZLES FOR LEVEL TRANSMITTERS AND LEVEL GAUGE ARE AT THE HORIZONTAL ELEVATION.
6- FOR NOZZLES DETAILS, ALIGNMENT AND HEIGHT OF LEVEL INSTRUMENTS SEE MECHANICAL DRAWING.
7- SET PRESSURE OF PZV-0003 HAS BEEN READJUSTED BASED ON A DISTANCE FROM UPPER TL OF D-0004 TO PZV. THIS DIFFERENCE OF ELEVATION SHOULD NOT
BE HIGHER THAN 9.8 m.
02

NOTE 4

This document is the property of SATORP and shall not be disclosed to third parties or reproduced without permission of the owner.

DATE

UTILITIES IDENTIFICATION

GENERAL NOTES

GENERAL HOLDS

DRUMS
TYPE
HEIGHT
DIAMETER
OP. PRESS.
OP. TEMP.
DES.PRESS.
DES.TEMP.

15
14

L1A

2"-PRW-101015010-101CS1P-N
1-1/2" 3"x1-1/2"

3780

02

2"

INST.
PIPING

3"x1-1/2"

WASH WATER
TO 101-G-0002-A/B

13

V 3/4"

INST. PIPING

02

3"-BFW-101015301-101CS1P-H

16

02

1/4"

15

23

MIN.

19

2"

FV
0015

25

MIN.

101-D-0004
2"

02

26

NOTE 6

2"-OSW-101015303-101CS1P-N

3/4"

NOTE 3

02

L2A

3/4"

27

3/4"

CL300

1/4"

29

L1B

02

2"

3/4"-LPF-101015303-101CH2F-N

NOTE 5

FY
0015 A

FT
0015

28

6513

LT
0032

10

HC
0049

29

ZC
0011

12

31

PC
0012

NOTE 5

2"-PRW-101015014-101CS1P-P

FC
0015

PT
0012

32

17

LT
0008

02

FY
0015 B

33

1/4"

13

11

34

L2B

NC

14

3592

NOTE 3

3/4"

35

29

INST. PIPING

1"

15

1"-LPF-101015301-101CH2F-N
NNF

3"-WST-101015001-101CS1P-P

19

3/4"

PIPING INST.
2"
W

50-100%
SPLIT
RANGE
0-50%

36

NC

2"x1"
2"

2" V
CL300

2"

20

CL300

02
PIPING INST.

02

02
CL300

22
21

FC
TSO

37

1/4"

CL300

3593

NOTE 3

1"

NO POCKETS 1"-LPN-101015001-101CS1P-N

35

02

38

101CS1P
101CH2F

PV
0012 A

36

101CS1P
101CH2F

37

02

POS.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

DESCRIPTION
FIRE WATER
SERVICE WATER
COOLING WATER
POTABLE WATER
DEMI WATER
N.A.
N.A.
N.A.
HP STEAM
MP STEAM
LP STEAM
HP CONDENSATE
MP CONDENSATE
LP CONDENSATE
BFW
PLANT AIR
INSTRUMENT AIR
N.A.

REF. DWG POS.

101-153
101-152
101-153

101-151

101-151
101-151
101-154
101-154

19
20
21
22
23
24
25
26
27
28
29
30
31
32

DESCRIPTION
N.A.
FUEL OIL
FUEL GAS
N.A.
N.A.
N.A.
CLOSED DRAIN
N.A.
L.P. NITROGEN
H.P. FLARE
L.P. FLARE
SOUR/ACID FLARE
PILOT GAS
AUX COOLING WATER

COMPANY
STATUS

REVISION MEMO

APPR/AUTH BY

REF. DWG

101-155

JUBAIL EXPORT REFINERY


PIPING AND INSTRUMENT DIAGRAM
101-158

DISTILLATION AND HYDROTREATING


LOW PRESSURE HYDRODESULPHURISATION TRAIN 1
WASH WATER BREAK TANK

Project:

101-154
101-156
101-155
101-152

Item Tags :

101-D-0004

Syst./ S-Syst.:

COMPANY
Document N
Contractor/Vendor
Document N

Electronic Filename
SA-JER-DS101-TRJR-480014.pid

Discipline: PRO

SA-JER-DS101-TRJR-480014
2271-101-PID-0021-015

REV: 02

Sheet: 1 of 2

SCALE: NONE
Format:

A1

Вам также может понравиться