Вы находитесь на странице: 1из 1

41 41

RESET
ZHSR ZC ZHXS ES
SIGNAL
40 TO FV-0001 FC 0025 0024 0025 L 40
DS101-TRJR-480001 0001 PI NOTES 5,6
39 3538 0091 ZYV CLOSED OPEN POSITIONER BY-PASS 02 UNIT 101 UNIT 691 39
L +

0025 S ZLC ZLO ZYC ZHI B.L.


38 0025 0025 0025 0025 INTERCONNECTING 38
PT PI IA
FT DE 103CS1P 103CS1X
37 HH 0001 A 0091 0090 37
ZC TI TT
INST. 02 02 ZLS ZLS ZY ZHS
0024 0001 0001 PIPING 02 02
1/2" 1/2" INST. INST. ZV 0025 C 0025 O 0025 0025
36 + ATM 02 36
2" PIPING PIPING 0025 LPT
3/4" 02 3/4" HOLD 1
35 DIESEL FEED 35
10"-HCB-101005003-103CS1P-N 10"-HCB-101005003-103CS1P-N IP-1110-L
TO 101-S-0001
DS101-TRJR-480001 NOTE 4 FC NOTES 1,2 MIN. DIESEL FEED

MIN.
34 TSO 34
3326 FROM STORAGE
UNIT 661-T-1005
33 1/2" 1/2" PIPING SA-JER-ITF-691-TPI-PID-481027 33
MIN.
INST.
FT
32 02 MIN. 32
0001 B
3/4" 2"-HCB-101099006-103CS1P-N
31 RESET ES 31
ZHSR ZC ZHXS UC

MIN.
0026 0025 0026 L
30 SIGNAL 30
TO FV-0002 FC PI NOTES 5,6 CLOSED OPEN POSITIONER BY-PASS
0002 0093 ZYV
DS101-TRJR-480001
L ZLC ZLO ZYC ZHI 103CS1P

250 mm MIN.
29 +
29
3540 0026 S
101CS1P
0026 0026 0026 0026
28
FT PT PI IA 28
HH DE 2"-CLD-101099301-101CS1P-N
ZC TI TT 0002 A 0093 0092
27
0025 0002 0002 INST. 02 02 27
02 ZLS ZLS ZY ZHS
PIPING
1/2" 1/2" INST. INST. ZV ATM 0026 C 0026 O 0026 0026 25
103CS1P 103CS1X
26 3718 02 26
2" PIPING PIPING +
02
3/4" 02 3/4" 0026 LPT
KEROSENE FEED
HOLD 1
25 10"-HCB-101005004-103CS1P-N 10"-HCB-101005004-103CS1P-N IP-1112-L 25
TO 101-S-0001
DS101-TRJR-480001 NOTE 4 FC NOTES 1,2 MIN. KEROSENE FEED
TSO FROM STORAGE DISULFIDE OIL FROM MEROX

MIN.
24 3344 24
661-T-1004
1/2" 1/2" PIPING SA-JER-ITF-691-TPIT-481026
23 MIN. 23
INST.
FT
22 0002 B MIN. 22
3/4"
SIGNAL 02 PI TI 2"-HCB-101099007-103CS1P-N
FROM HS-0024
21 0095 0151 UC 21
L

MIN.
DS101-TRJR-480003
3773 FI
20 20
0014

250 mm MIN.
103CS1P
FT
19 PT TT PI 101CS1P 19
0014 02
0095 0151 0094 02
INST. 02
18 101CS1P 101CS2P 18
PIPING INST. INST. 2"-CLD-101099302-101CS1P-N
1/2" 1/2"
02 PIPING 2"CL300 PIPING
17
3/4" 3/4" 02 17
25 LPT 02
STRIPPED SOUR WATER
3"-WST-101015001-101CS1P-N 4"x3" 4"x3" 3813
IP-1105-L
TO 101-G-0002A/B
3"-WST-101015001-101CS1P-N
16 16
DS101-TRJR-480014 CL300 MIN. STRIPPED SOUR WATER

MIN.
3399 FROM SOUR WATER STRIPPING UNIT 213/212
15 15
SA-JER-ITF-691-TPI-PID-481001
MIN.
14 14
02
SIGNAL MIN.
13 3/4" 13
FROM HS-0024 3/4"-WST-101099001-101CS1P-N
DS101-TRJR-480003 UC

MIN.
12 6898 2"x3/4" 12

11 11
PI 101CS1P

250 mm MIN.
0108 101CS2P
10 TI 10
0150
02 INST.
9 PIPING 2"-CLD-101099303-101CS2P-N 9
3/4"
2"
8 25 8
LPT 02 02
3814
SOUR WATER
3"-SRW-101032004-106CH2S-N 4"x3" 4"x3" 3"-SRW-101032004-106CH2S-N IP-1102-L
7 FROM 101-G-0006A/B 7
SOUR WATER

MIN.
DS101-TRJR-480052
3499 MIN. TO SOUR WATER STRIPPING UNIT 213
6 6
SA-JER-ITF-691-TPI-PID-0481001
MIN.
5 5

MIN.
4 3/4" 4

UC 3/4"-SRW-101099001-106CH2S-N

MIN.
3 3
2"x3/4"

2 2
106CH2S

250 mm MIN.
1
101CH2S
1

2"-CLD-101099304-101CH2S-N

25
3815

 
02 22-DEC-2010 AFC AFC: APPROVED FOR CONSTRUCTION JGT / STG AVS / HPR HS

ORIGINAL SIGNED IN PROJECT FILE  01 18-MAY-2010 AFC AFC: APPROVED FOR CONSTRUCTION JCP / FCB RDP / HPR HS

00 23-DEC-2009 IFD IFD: ISSUED FOR DESIGN JVM / FCB RDP / HPR HS

REV DATE COMPANY REVISION MEMO PREPARED BY CHECKED BY APPR/AUTH BY


STATUS
GENERAL HOLDS GENERAL NOTES UTILITIES IDENTIFICATION
1- EACH INSTRUMENT TAG NUMBER IS PREFIXED BY 101 (EX 101-TT-0001). THIS DRAWING IS VALID FOR TWIN LP HDS: UNITS 101 AND 102. POS. DESCRIPTION REF. DWG POS. DESCRIPTION REF. DWG
2- FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWINGS SA-JER-DSAAA-TRJR-480001 THROUGH SA-JER-DSAAA-TRJR-480019. 1 FIRE WATER 19 N.A.
HOLDS 3- EACH BATTERY LIMIT EMERGENCY SHUTDOWN VALVE SHALL HAVE A DEDICATED SAFE LOCATION ACTUATING BUTTON. THE SAFE LOCATION ACTUATING BUTTONS 2 SERVICE WATER 101-153 20 FUEL OIL
1- REQUIREMENT OF VENT AT HIGH POINT OR DRAIN AT LOW POINT TO BE CONFIRMED AFTER PIPING LAYOUT STUDY. SHALL BE GROUPED TOGETHER AND INSTALLED AT GRADE AND LOCATED MORE THAN 15m FROM ANY FIRE. HAZARDOUS EQUIPMENT OR PROCESS VESSEL SAFE 3 COOLING WATER 101-152 21 FUEL GAS 101-155
02 LOCATION BUTTONS SHALL ALSO BE AT LEAST 7,5m BEYOND THE EDGE OF ANY FIRE. HAZARDOUS ZONE. 101-153
4 POTABLE WATER 22 N.A.
4- IP'S INFORMATION OF TWIN UNIT CAN BE FOUND IN P&ID SA-JER-DS101-TRJR-480053.
5 DEMI WATER 101-153 23 N.A.
JUBAIL EXPORT REFINERY
6 N.A. 24 N.A. PIPING AND INSTRUMENT DIAGRAM
NOTES 7 N.A. 25 CLOSED DRAIN 101-158
1- BATTERY LIMIT ZV. 8 N.A. 26 N.A.
Project:
DISTILLATION AND HYDROTREATING
2- VALVE TO BE LOCATED AT LEAST 7,5m BEYOND THE EDGE OF ANY FIRE HAZARDOUS ZONE. 9 HP STEAM 27 L.P. NITROGEN 101-154 LOW PRESSURE HYDRODESULPHURISATION TRAIN 1
101-151
3- DELETED. 10 MP STEAM
101-151
28 H.P. FLARE
101-156
B.L. PROCESS No 1
4- HIGH RANGEABILITY FT-XXXX-A LIGHT FLOW AND FT-XXXX-B FOR HEAVY FLOW. 11 LP STEAM 29 L.P. FLARE
5- COMMON RESET SHALL BE CONFIGURATED IN BLOCK AND BLEED VALVES CASES. 12 HP CONDENSATE 30 SOUR/ACID FLARE
Item Tags :
6- COMMON RESET SHALL BE CONFIGURATED IN SIL 3 VALVES. 13 MP CONDENSATE 31 PILOT GAS 101-155
14 LP CONDENSATE 101-151 32 AUX COOLING WATER 101-152 Electronic Filename
Syst./ S-Syst.: Discipline: PRO SA-JER-DS101-TRJR-480040.pid
15 BFW 101-151
16 101-154 COMPANY SA-JER-DS101-TRJR-480040
PLANT AIR
Document N°
REV: 02
SCALE: NONE
17 INSTRUMENT AIR 101-154
Contractor/Vendor
18 N.A. Document N° 2271-101-PID-0021-099 Sheet: 1 of 4 Format: A1

This document is the property of SATORP and shall not be disclosed to third parties or reproduced without permission of the owner.

Вам также может понравиться