Вы находитесь на странице: 1из 3

Specific speed Calculation from Bleier

q
2.312 m3/s
4.90E+03 CFM
Speed
1450 rpm
Static pressure
120 pa
0.547263 in of water coloum
159505.2 rpm
Sp
specific speed
omega
ns
ratio
ratio 2
Dt or D2
Wt or b2
Dh or D1
Prcoefficient
u2
u1
beta1
beta2
relative Vr1
maridonial Vm1 or V1
Wh or b1
maridonial Vm2
Vw2
no:of Blades
power
power to fluid
power required

151.8436 rad/s
20.3
0.2
0.76
0.48 m
0.096 m
0.3648 m
0.150596
36.44247 m/s
27.69628 m/s
25 deg
46.5 deg
30.55946 m/s
12.91499 m/s
0.156203 m
15.97076 m/s
21.26839 m/s
19
775 watts
277 watts
1387.2 watts

rad/s
Wt/Dt
Dh/Dt

Specific speed

unitlesss

<30 & >10 deg


<50 & >35 deg

< 0.161242 m

density of air
Assuming a static efficiency of 20%

m/s ###

Specification
D1
D2
b1
b2
beta 1
beta 2
Power Predicted
Power based on static pressure rise
Power Based on ESDU Graph
vanes

360 mm
500 mm
160.0 mm
100 mm
25 deg
47 deg
775 W
1387 W
1800 W
12

blade angle angle between

Based on equation for static power induced ESDU

b1
b2

1 kg/m^3

D1

D2

blade angle angle between relative velocity and tangential velocity

or static power induced ESDU 79037

Вам также может понравиться