Thermowell Velocity Rating

(Program Ver. 4.3) Company: Project No:


Reference:

Tag #: Date: Rev:


U

d
A

FLUID DATA
Fluid Operating Temperature Operating Pressure Fluid Velocity To Po V Steam 500 100 85 F psig ft/sec

CONSTANTS
Kf K1 K2 K3 3.05 0.413 49.2 0.075 5.588 ft3/lb

t/A t/B
FA FB

0.22 0.38 1.3 1.0

WELL DATA
Well Material Unsupported Length Bore Diameter Tip Diameter Root Diameter Specific Weight @ To Mod of Elasticity @ To Allowable Stress @ To U d B A w E S 304 7.50 0.260 0.625 1.100 0.285 40.0 25.0 in in in in lb/in3 psi x 10
6

CALCULATIONS
Natural Frequency @ To Wake Frequency Frequency Ratio Magnification Factor Max Length @ V (r=0.8) Max Velocity @ U (r=0.8) Max Static Pressure Max Stress Length Max Stress Velocity

fn fw r
Fm Um Vm Pm Ls Vs

643 359 0.56 1.45 9.0 122 10337 111.37 1262.2

Hz Hz

in ft/sec psig in fps

psi x 103

NOTES

These calculations are performed according to the paper "Power Test Code Thermometer Wells" by J. W. Murdock, and also meet the requirements of ASME PTC 19.3-1998. Note that ASME PTC 19.3-1998 is NOT current and has been replaced with ASME PTC 19.3 TW-2010 released in April, 2010. The results of running this program should only be used as a guide for thermowell design. Thermo-Kinetics assumes no responsibility for failure of a well based on the results of these calculations, and accepts no liability direct or consequential, arising from error or misinformation supplied herein, or due to program misuse.