+=========================================================== HELP FULL COMMAND FOR MOSHELL_CPP_CYGWIN_UNIX_LINUX_SOLARIS_OSS by hoang.p.le@ericsson.

com Update 6/5/2013 9:40AM UPdate time: 7/31/2013 10:02AM -> 10/17/2013 11:40AM +=============================================================== +TAG content: cygwin, moshell,AMOS, RNC, RBS, mobatch, linux, bash TIPS, solaris , unix 1. COUNTER command pst pgets proxy ( proxy from pst) 2. pst MO pm_of_MO cat 2/raw/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmExtract -u utrance ll "." cat 2/RAW/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmList -m utrancell 3. list all log file on RNC: ftreef /c/logfiles 4. prints the state and configuration of the IP interfaces stir 5. stip 6. Check number of cells in each RNC module lkr 7. tip on pmr command pmr -r 7-10 -l 2/rcpd01/110308_100929/RCPD01_ropfiles.zip -s 20110307.1400 -e 20 110307.1700 pmr -r 7-10 -s 20110309.1200 -e 20110309.1800 8. How to fetch log for a duration time lgtaom -l 2/rcpd01/20110310_102758/RCPD01_logfiles.zip -s 2011-03-09.1200 -e 201 1-03-09-17.1700 9. print cell data for all cells belonging to IubLink=Iub_304 ced -r iub_304 --> print cell data for all cells belonging to IubLink=Iub_ 304 10. Check board load C:\WORKING\3G\VTL RAN 3G\10 - Trick\capi.TXT or by pmr 11. How to use tesummary, output html file ./decoder/teSummary.pl -file 5/110308_101656/teread.log -html 5/110308_101656/te read.html

12. How to count No. of file in folder ls -l | wc 13. flowfox follow time ./decoder/flowfox.pl --file ./decoder/log/cd3.txt --start 11:03:00.000 --end 11: 04:50.000 -o ./decoder/log/cd3_flowfox_2.html --imsi 452048800046217 Processing ./decoder/log/cd3.txt: Log start timestamp: 11:03:00.000 Log end timestamp: 11:04:50.000 Flowfox is scanning for timestamp information ... Flowfox is now locating UeRefs for IMSI filter ... IMSI Filter >> (452048800046217): UE refs found () Processing logfile, this may take some time... 0%..........20%..........40%..........60%..........80%..........100% Done! >> Output saved to ./decoder/log/cd3_flowfox_2.html 14. Checking SCCPAP infor in GPB C2 lhsh 000700 rof_sccpAP_info lh ranapmp ueregprint all;arealist cell all;ranap status;ranap conn;ranap dumpRo Table survey;ranap dumpRoTable;rncss_ranap;rnsap status;rnsap conn;rnsap dumpRoT able survey;rnsap dumpRoTable;rncss_rnsap;lcs; ranap status 0;ranap cong -froid 0; ranap status 1;ranap cong -froid 1; rnsap status 0;rnsap cong -froid 0; rnsa p status 1;rnsap cong -froid 1; rnsap status 2;rnsap cong -froid 2; 15. How to parse MOM -moshell offline -parsemom /home/ephucle/moshell/jarxml/RNC_NODE_MODEL_K_9_115_COMPLETE.xml 16. How to read counter pmx -l RCPD26_ropfiles.zip . pmNoSysRelSpeechUlSynch 17. How to read formula OFFLINE_RCPD26_DCG_K> l cat /home/ephucle/moshell/commonjars/pm/FORMULA_RNC_K_1_ 0.txt | grep SHOFailContrib 18. Check UE in iublink uer -r Iub_IHN589 19. How to remodule for nodeB set Iub_IHN589 atmUserPlaneTermSubrackRef 20. How to check traffic in nodeb uer -m 8 21. How to Ping CP & UP of RNSAP/RANAP ipac_traceroute -z .. -d.. ipac_ping -z .. -d.. UP ping: facc IpAccessHostEt_sourceRNC ping IpAccessHostEt_destRNC

CP Ping: GURO02_ERNC06> ipac_ping -z IpAccessHostGpb_ipAddress1/2 -d IpAccessHos tGpb_ipAddress1/2 22. Ethernet mode setting for RNC OAM ethernet mode config ethmode 23. check ip connection: stip 24. check ranap status: lhsh 000700 ranap status sccadm_info all 25. How to test RANAP lh ranapmp lh ranapmp lh ranapmp RCPD32> lh ranap enable 1 te e bus_receive bus_send rnhRanapRouterC fte s ranapmp fte s

110428-09:52:01 10.59.240.249 8.0s RNC_NODE_MODEL_L_1_119 stopfile=/tmp/11036 Position Board dTraceConditions 0007 GPB65 e1 0007 GPB65 e1 0022 GPB65 e1 0022 GPB65 e1 0022 GPB65 send bus_receive mon ranapmp u+ del ranap_sg urun Process RNC_EXCEPTION UEH_EXCEPTION RNC_EXCEPTION UEH_EXCEPTION rnhRanapRouterC Status enabled enabled enabled enabled enabled Adde trac trac trac trac bus_

and then turn on trace l /home/ephucle/moshell/monitor6054 10.59.240.249 33079 | ./decoder.pl --w10b | tee ./log/ranap_reset.log | ./flow.pl -colour 26. cell trace, know cell id lh mod uerandtrace on -cell 9016 27. remove file in cygwin: rm 28. How to decode ctr.bin file unzip: gzip -d ./2/rcpd10/CTR/*.gz decode: you have to pipe the output to "decoder.pl --extern" in order to decode the embe dded signalling messages such as NAS,etc --gpeh: for ctr and gpeh

--extern for view NAS message ./decoder/decoder.pl --p71 --gpeh ./2/rcpd10/ctr/*.bin | ./decoder/flow.pl -colo ur | tee ./2/rcpd10/ctr/ctr_decoded.txt 29. How to use zpm tool to decode dump log on CPP node l zpm error 2/rcnh06/110610_174755/20110610_102249_c_pmd_90_000500_0xbea00015.p md -o 2/rcnh06/110610_174755/0xbea00015_decoded.txt 30. How to turn on and turn off UE trace: off: lh mod ueidtrace off -ue -all (default) lh mod ueidtrace off -ue -all ; uerandtrace off -cell -all #Check status ongoing selective or random UE traces lh mod uerandtrace status ; ueidtrace status lhsh 000600 uerandtrace status (check for random trace)

turn on on: lh mod ueidtrace on -ue imsi $imsiVar 31. How set struct by MO script, ex SET ( mo "ManagedElement=1,RncFunction=1,IurLink=742" exception none userPlaneTransportOption Struct nrOfElements 2 atm Integer 0 ipv4 Integer 1 ) 32. How to check data of module lh mod22 drh_dcrh_topdata all lh mod22 drh_ccrh_topdata all 33. How to do eteloopback test for E1? 23251 1 (ENABLED) 90 23252 1 (ENABLED) 91 acc 23251 23252 eteloopback 34. Check MO status after load DT. st all 1.*0 st all 0.*1 35. DCGM location folder for AMOS in OSS var/opt/ericsson/amos/moshell_logfiles 36. st cell 1.*0 st cell 0.*1 37. How check cell data lh mod60 celldata -c 16011 AtmPort=MS-15-3,VplTp=vp13,VpcTp=1,VclTp=vc13 AtmPort=MS-15-3,VplTp=vp13,VpcTp=1,VclTp=vc13

110716-14:55:17 10.59.240.1 8.0h RNC_NODE_MODEL_K_9_115_COMPLETE stopfile=/tmp/4 844 ================================================================================ ============= $ lhsh 000600 celldata -c 16011 0006: -----------------------------------------------------0006: cId: 16011 0006: cellFroId: 400 0006: RO instance: 109 0006: RNC Module: 0 0006: IubLink froId: 89 0006: CC SP: 001800/sp0.lnh/CommonChMainPT 0006: Total ASE DL: 2.96 0006: aseDlAdm: 500 0006: Total ASE UL: 2.59 38. How to check ntp server synchronization in nodeB $ ntp peerinfo NTP Info remote et disp

refid

strat flags when

poll reach delay (sec)

offs

(sec) (sec)

================================================================================ ========== x 10.50.26.2 0.0.0.0 16 1 0 1024 0 0.00 0.0 00 0.00 x 10.50.26.1 0.0.0.0 16 1 0 1024 0 0.00 0.0 00 0.00 x : Reject # : Falsetick ^ : Excess - : Outlyer + : Candidate s : Selected * : Sys.peer o : Prosp.Peer 39. Checking mspg for ETMF4 hget mspg selectedBoard|selectedPort

40. pmx check rssi value of rbs pmx carrier -m 24 -a pmxh sl2056 pmNoRrcConnReqBlockNodeCs|pmNoRrcConnReqBlockNodePs|pmNoRejRrcConnM pLoadC|pmTotNoUtranRejRrcConnReq|pmNoRrcReqDeniedAdm|pmNoRrcPsReqDeniedAdm|pmNoR rcCsReqDeniedAdm -m 8 41. check the speed of the fan in RBS6000 The trace to check the speed of the fan in the RBS6000 te e all supSysCtrlClimate search for setfan in the temp traces OR ter | grep -i setfan ================================== 42. TIPS checking when intergration a. in most cases, we can check: alt, utrancell locked or unlocked, cellreserved,

lk, eteloopback etc. b. check KPI: pmr s 20110809.0100 c. check CS, PS performance:

e 20110809.0200

pmxh cell.*0001 pmTotNoRrcConnectReq$|pmTotNoRrcConnectReqSuccess -m 5 pmxh cell.*0001 pmTotNoRrcConnectReqPs|pmTotNoRrcConnectReqPsSucc -m 5 pmxh cell.*0001 pmTotNoRrcConnectReqCs|pmTotNoRrcConnectReqCsSucc m 5 d. check uplink interfere: RBS: pmr r 1

e. check utrancell power related: RNC: get utrancell.*52511C1 maximumTransmissionPower Get utrancell.*52511C1 primaryCpichPower RBS: get . maxTotalOutputPower f. If customer told you check RBS output power, you can use: RBS: pmr r 1 g. check VSWR: lh rru fui get vswr h. check transmission quality: pget e1 i. restart rru j. restart DU ===================================== 43. truni: By default, the command trun file halts when a command fails. truni: ignore exceptions, the execution does not halt when a command fails. OFFLINE> h truni ******************************************************************************** ******* trun[is1cr] <moScript>|<http://ipaddress/script> ******************************************************************************** ******* It is also possible to specify a file located on a web server (eg. when the scri pt is located on the CPP node). See examples below. For more info, refer to MoTester documentation on http://utr an01.au.ao.ericsson.se/moshell/training/references/cpp/runMoTester.html . Options: - i: ignore exceptions, the execution does not halt when a command fails. - s: simulated run, the command file execution is simulated, no commands are ac tually executed on the node. Can be used to verify the syntax of a script prior to running it for real. The simulated mode is always used in "offline mode" or " simulated undo mode", regardless of the "trun" options.

- 1: executes the whole script in one transaction, then prompts for confirm or rollback. This option should be used with great care and only when absolutely ne cessary (e.g. when changing IP address of the node, see example script in moshel l/examples/misc/ip_change.mo). In regular usage, it is recommended to not use th is option as it has been observed to cause database corruptions in certain cases . - c: used in combination with option "1" above, will avoid the prompt by automa tically confirming the transaction - r: used in combination with option "1" above, will avoid the prompt by automa tically rolling back the transaction 44. dump online -list dump dump list -a dump error -i /c/pmd/37/001600/0xfdf59d9f.pmd 45. Checking sleeping cell issue (Using RRC) KG5071C | YGIN07_ERNC10 | pmxh -m 1 UtranCell=YI07_10_.*_KG5071 pmTotNoRrcConn ectReq$|pmTotNoRrcConnectReqSuccess|pmCellDowntimeAuto|pmCellDowntimeMan 46.SGSN in Pool (iuflex) if you can define a lot of ranap mo mean that you have enable iuflex and NRI(for PS) in rncfunction=1 mo is greater than 0. I have configure SGSN inpool for RNC 3820 with ericsson SGSN. In my opinion, you can check the addtibute "cnId" in ranapmo. it is correct of n ot. by the way, you should also double check the attibute "destPointCode" in Mtp 3bSrs" mo. The last thing yuo can do is put some trace on RANAP_ASN, use action "setAutoActivate", "setAutoDown" of m3ua mo and see the message go forth and bac k between RNC and SGSN. 47. wireshark filter ranap.gTP_TEI == 0x00008a2b gtp.teid == 0x00008a2b 48. Display state, user, and bandwidth usage for ATM ports and channels. stvb stv[b][r] [<Filter>] [<stateFilter>] ******************************************************************************** ******* Display state, user, and bandwidth usage for ATM ports and channels. 49. How to Restart scc_server in SCCP MP lh sccpmp sma -all | grep scc # find the CXP number of the scc_server Load Modul e acc Program=CXC.._R.. restart y 50. How to Show node on OSS example: pwAdmin -l | grep rnc | 91. List node from OSS : more /etc/hosts 51. Sync trace RBS https://cc-jira.rnd.ki.sw.ericsson.se/jira/browse/CPP-1307

Trace settings: ------------------te enable trace1 trace8 trace9 Nss_tuRegMp_proc COLI commands: ----------------------nssinfo clk nssinfo fls nssinfo osc 52. How to do SW allocation by moshell set . autoconfigurationallow true pr swallocation acc MO deleteslot acc MO addslot 53.How to setting Ethernetmode >lssfpconf Card Port X SFP mgmt 10GbE A 18 autconf 10GbE B 28 autconf 10GbE C 32 autconf 10GbE D 42 autconf for APP port SFP type nc nc unknown unknown PHY mode limiting limiting limiting limiting Module nc nc NOK NOK Linkprop YES YES YES YES

>setmode 32 1gforced Command setmode executed for card on slot: 3, channel: 1 Mode for port set OK >setmode 42 1gforced Command setmode executed for card on slot: 3, channel: 2 Mode for port set OK >lssfpconf Card Port X SFP mgmt SFP type PHY mode 10GbE A 18 autconf nc limiting 10GbE B 28 autconf nc limiting 10GbE C 32 autconf unknown 1gforced 10GbE D 42 autconf unknown 1gforced Command lssfpconf executed OK 53. license intergration unlock test status license iu status 55. How to Ping to test sigtran ipac_traceroute -z -d 54. How to check CPU load for aboard $ lhsh 000800 lcs 0008: Load Control Statistics 55. Command to activate trace lh lh lh lh mod mod mod mod ueidtrace on -ue imsi 452022114994487 uerandtrace on -cell 65000 te e bus_send bus_receive UE_ASN_RRC te e bus_send bus_receive UE_ASN_RANAP

Module nc nc NOK NOK

Linkprop YES YES YES YES

lh mod te e bus_send lh mod te e bus_send //lh mod uerandtrace //lh mod te e trace4 //lh mod te e trace1 //lh mod te e trace3

bus_receive UE_ASN_RNSAP bus_receive UE_ASN_NBAP max 100 UE_GENERAL UEH_EXCEPTION IU_IF

//lh mod ueidtrace off -ue -all //trace on DC device lh dc2021 lh dc2021 //lh dcxx //lh dcxx lh mod te te e all IUC_CONTROL_UL_UE te e all IUC_CONTROL_DL_UE te enable trace3 trace5 DISCARD_UE te enable all SP_EXCEPTION e trace3 IU_IF

56. How to collect counter pmxk -m 4 UtranCell=HC13961 pmNoSystemRabReleasePacket$ 57. How to restart aboard on RNC OFFLINE> h progkill ******************************************************************************** ******* proglist/progkill [-e] [<string>] [|<unix-cmds>] ******************************************************************************** ******* List or restart programs on boards or board groups. These two commands are wrappers for the COLI commands pglist/pm_pginfo and pgkil l/pm_kill. The proglist command lists the OSE programs running on MP, BP, or SP processor. The program handle, state, program number and name are shown. With option "-e", the heap and pool size are also shown. It is also possible to add a filter after the "-e" option in order to show other program settings apart from the heap and pool. Eg: "proglist -e stack" shows all program settings matc hing the word "stack". A list of all available program settings is shown at the end of the printout (wh en option "-e" is used). The progkill command is used for restarting an individual program on a MP. If th is command is used on a BP or SP then the whole processor restarts. A string whi ch matches the program number or program name must be given as argument to the c ommand. Eg: "progkill jvm", or "progkill 0784" Examples: - List programs on central MP: >> proglist - List programs on board 001400, whose product number match "0787" >> lhsh 001400 proglist | grep 0787 - List programs on all MP/BP/SP processors together with heap and pool info >> lh all proglist -e - Show the stack size for all programs running in the O&M MPs >> lh ommp proglist -e stack_size$ - List programs on all boards of the boardgroup "mp", whose name match "system"

>> lh mp proglist | grep system - Restart the program whose product number matches "2417" on board 001400 >> lhsh 001400 progkill 2417 - Restart the programs whose name matches "aal2ap" on all boards of the boardgr oup "mp" >> lh mp progkill aal2ap 58. How to extract mobatch log result example: extract finger print of nodeB from mobatch logs grep -i "finger" *.log 59. How to run GUI on nodeB by command a. download bemcli.jar by moshell htget http://rbsIp/em/bemcli.jar b. run from OSS java -jar bemcli.jar 10.244.2.39 help Usage: BEM on the command line connects to the specified RBS and executes the commands as described below. <host name/ip address> help Displayes this help. <host name/ip address> cabinet <input cabinet xml file> Runs Cabinet Equipment Wizard with specified xml file. ....... Sample: java -jar bemcli.jar 10.0.0.1 cabinet my_cabinet_xmlfile.xml -rbs_prop /user/bem /RBS_EM.properties 60. How to format nodeB + and load basic package for nodeB 1) reload -this will enter backup mode 2) mount_c2 this will mount /c2 drive 3) formathd /d this will format the /d drive 4) formathd /c2 this will format the /c2 drive 5) reload -to initialize the disk 6) ifconfig le0 IP netmask to set the ip address and subnetmask 7) reload refresh the Node-B 61) How to trace to find out what counter increase when CS call drop lh mod te e trace3 IU_IF example trace log: IU_IF) ../src/UehPmEventDataD.cpp:1394 TRACE3:Increment counter ROAM_UTRANCELL_P

MNOSYSTEMRABRELEASEPACKET; for Source Best Cell on observed instance Id=380; num OfSteps=1; cellId=50186; cellFroId=380; sRncUeRef=1006; sRnti=66542; IMSI = 2700 11008275182; connType = uehPacketCch. (IU_IF) ../src/UehUeCtxtC.cpp:1362 TRACE1:Sending IuReleaseRequest for packet sw itched CN with cause 16; UeRef = 4940; IMSI = 270011006155400; cellId = 50178; c ellFroId = 308; S-RNTI = 70476; connType = uehSp64, globalCnId: mcc = 270, mnc = 1, mncLength = 2; cnId = -1 (User Inactivity) 62. How to restart GPB C1 by telnet/serial command Using the serial port, restart the Core MP using the following command $ restartObj me If the restart command does not trigger a restart of the Core MP, reload the Cor e MP using the following command $ reload

63. ranap conn usage RSG081E> lhsh 000700 ranap conn usage 120829-16:45:05 10.20.130.60 9.0a RNC_NODE_MODEL_K_9_115 stopfile=/tmp/7468 $ lhsh 000700 ranap conn usage Print information from RANAP connection table. Usage: ranap conn Prints the first n connections in the table, for all froIds. Usage: ranap conn <froId> Prints the first n connections for a specific froId. Usage: ranap conn -option1 <value> -option2 <value> -option3 <state1> <state2> ... Advanced search in RANAP table. Available Options are: -froid <num> // only show conns for one froId -sccpstate <state1> <state2> // only show some sccp states -uectxtstate <state1> <state2> // only show some uectxt states (as perceived fr om ranap) -ueref <num> // only show for one ueref # -moduleid <num> // only show for uerefs on one module mp or Mbms -domain <num>|cs|ps // only show for one domain range for <num> is 0 (cs) to 1(ps) -iusignconnid <num> // only show for one iu signalling connection -from <num> // start looking from sccp conn id <num> -limit <num> // only show first <num> hits -to <num> // stop looking at sccp conn id <num> Available states are: conn, notconn, notconn_msg, inpend, outpend Example: ranap conn -froid 1 -moduleid 12 -sccpstate conn -uectxtstate inpend outpend $ 64. check allocated status of nodeB stdr lhsh 000700 drhcendh dc

65. catch IU CS userplane message by lh dc80 te e bus_send bus_receive IUC_CONTROL_UL_UE lh dc80 te e bus_send bus_receive IUC_CONTROL_DL_UE 66. Trace in IMSI/CELL //lh modxx uerandtrace -cell -all //lh modxx uerandtrace max -unlim lh mod ueidtrace -ue imsi 452010801018644 //lh mod uerandtrace on -cell 34058 //if want to trace on CELL turn on this //lh mod uerandtrace on -cell 34059 lh lh lh lh mod mod mod mod te te te te e e e e bus_send bus_send bus_send bus_send bus_receive bus_receive bus_receive bus_receive UE_ASN_RRC UE_ASN_RANAP UE_ASN_RNSAP UE_ASN_NBAP

lh mod te e trace1 UEH_EXCEPTION lh mod te e trace4 UE_GENERAL lh mod te e trace1 trace3 IU_IF //lhsh <modx> te eall UE_IRAT_HANDOVER //lhsh <modx> te e all UE_IRAT_CELL_CHANGE //lh ranapmp te e trace3 Scc_server_proc //Trace on SCCP

mon mod l $moncommand | decoder/decoder.pl --p71 | tee trace/PSHO/E_N2.log | decoder/flo w.pl -colour | tee trace/PSHO/E_N2_flow.log ============== trace SHO lhsh <Module> lhsh <Module> lhsh <Module> lhsh <Module> te te te te e e e e bus_send bus_receive bus_send bus_receive bus_send bus_receive trace4 trace6 trace UE_ASN_RRC UE_ASN_RANAP UE_ASN_RNSAP 7 UE_GENERAL

#[2012-06-19 01:35:00.632] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5 529 TRACE6:Signal spConfigReq sent to port dcsIfControlP #[2012-06-19 01:35:00.632] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5 530 TRACE7:DcsSpConfigReqD{dcRhRef 24 76 101 128 48 0 3 30 236 0 0 0 0 0 128 49 0 0 0 0 12 0 0 0 1,ueRef -1,ueModuleId -1,mpBagBufPtr 1671050592,bagSize 0} #[2012-06-19 01:35:00.636] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5 452 TRACE6:uehProcedures[ueRef 7916]: signal spConfigCfm received on port dcsIfC ontrolP in state WaitSpConfigRsp #[2012-06-19 01:35:00.636] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5 452 TRACE7:uehProcedures[ueRef 7916]: signal data: DcsIfControlUeRefD{ueRef 7916 ,ueModuleId 12} lhsh <Module> te e trace1 trace6 trace7 UE_HANDOVER #012100/RncLmUePT(UE_HANDOVER_AS) ../src/UehSoftHoC.cpp:1878 TRACE3:Intra Soft R NC Radio Link Set Addition #012100/RncLmUePT(UE_HANDOVER_AS) ../src/UehSoftHoC.cpp:803 TRACE3:Event e1a rec eived with ScrCode = 306 for UeRef =

lhsh <Module> te e trace3 UE_HANDOVER_AS

lhsh <Module> te e trace1 trace3 UEH_EXCEPTION lh <dcSP> te e all SP_EXCEPTION lh <dcSP> te e trace1 trace5 HANDOVER_EVAL_UE lh <dcSP> te e bus_send bus_receive RRC_UL_UE # to trace the Measurement Report te e trace3 UE_COUNTERS_GSM_RELATION RncLmUePT(UE_COUNTERS_GSM_RELATION) ../src/UehPmEventDataD.cpp:747 TRACE3:Counte r ROAM_GSMRELATION_PMNOOUTIRATCCSUCCESSHS; not incremented for Target Gsm Cell R elation as adjcentCellGsmRelationCellFroId is not valid, block=UehUeCtxtC; sRncU eRef=n; sRnti=n; numOfSteps=1; gsmCellId=1; gsmCellFroId=-1; adjcentCellGsmRelat ionCellFroId=-1; procedureIndicator=UehProcIndIRATCellChange;

flowflox online tool http://utran01.epa.ericsson.se/flowfox/live.php BO check http://10.19.208.21:8080/InfoViewApp/logon.jsp cach chuyen tu ueh log sang html te summary log l ./decoder/teSummary.pl -f temp/RSGTB1E_EXCEPTION_121109_1133.log -html temp/RS GTB1E_EXCEPTION_121109_1133.html 67. paging counter utrancel::pmNoPagingType1Attempt UtranCell::pmNoPagingAttemptUtranRejected Paging::noOfPagingRecordTransm 68. How to download COMPLETE MOM online getmom RNC_NODE_MODEL_K_9_115_COMPLETE.xml 69. How to seach event id in measument report ( RRC) search "evID" 70. Path to CTR trace log in OSS /var/opt/ericsson/nms_umts_pms_seg/segment1/CTR/SubNetwork=RSG011E/MeContext=RSG 011E

!Check current MSC on UE! *789# !Connect to node from OSS! eaw NE=MSHC01E

!Convert MSISDN -> IMSI! mgtrp:msisdn=84936390077; !Check location! Mgssp:imsi=<imsi_number>;

71. AMOS folder /opt/ericsson/amos/moshell/monitor6054 72. How to trace and decode by AMOS l $moncommand | /opt/ericsson/amos/decoder/decoder.pl --w12b | /opt/ericsson/amo s/decoder/flow.pl -colour | tee /home/ericsson/hoang/emlpp_1.txt 72. AWK [~]$ cat ./temp/9_ueh_read/ueh_rsg101e_1453.txt | grep "ExceptionCode = " |$ gre p UehRncHardHandoverC|awk 'BEGIN{FS="ExceptionCode = "}{print $2}' | awk 'BEGIN{ FS=";"}{print $1}' | sort | uniq -c 14 409 187 509 ex2: [/cygdrive/c/working/CSR/2289506, Abnormal Dropped Call from ERA to NSN/log]$ ca t RSGTB1E_130611_1638_UEH.log | grep -i "causecode = rnsaprequested_configuratio n_not_supported" | awk 'BEGIN {FS=";sourceConnType ="} {print $2}' | awk 'BEGIN {FS="; "}{print $1}' | sort | uniq -c 6 uehPacket128 17 uehPacket12864 62 uehPacket128Hs 131 uehPacket384Hs 91 uehPacket64 239 uehPacket64Hs 1382 uehPacketEulHs 8 uehPsInt1616 104 uehPsInt1664 93 uehPsInt16Hs 1 uehPsInt6416 215 uehRrcConn 367 uehSp0 4 uehSp12864 2 uehSp384Hs 12 uehSp64 6 uehSp64Hs 1 uehSpeech 9 uehSpeechAmrNbMMPsInt16Hs 2 uehSpeechPsInt128Hs http://vi.wikipedia.org/wiki/AWK #print file by 73. perl http://www.slideshare.net/davorg/introduction-to-perl-day-1 how to call perl script from cygwin: add line: #!/usr/bin/perl -w vao dau script

call script by: filename ( trong cygwin) 74. egrep "MOs to grou" *.log 75. Reallocate all iublink resources evenly in the node resub iublink= 76. find out negative counter pmxs 77. change excuting right in solaris ericsson@vmshcxts01> chmod -R 777 /home/ericsson/hoang/rnchc 78. new read counter from ropfile pmextract 79. quickly check license by inv command invl 80. Check state for all sites located on a specific module RNC02> str -m 13 Check state for all sites located in a specific subrack RNC02> str -s ms Check state for all sites that use a specific transmission type (A=ATM, I=IP, AI=DualStack) RNC02> str -t ai 81. check with ced that there are no cells handled by a CC device belonging to a different module: the list is empty => Ok! RNC143> cedr | grep ! 82. Printing usage for all cells of a module RNC99> ced -m 1 rnc22> lh mod celldata -m Printing usage for one RBS RNC66> cedh -r iub_rbs54 83. uer advanced: Print all calls, but without showing the PDR device (saves time) uerp Print only the summary tables, not the individual calls RNC11> uers Print all drift contexts RNC99> uerd

Printing all variables for a context RNC10> uer -i 301001800040001 all Printing active UE contexts with RRT commands RNC12> ueregprint all 84. Recommended trace objects for UE tracing: UE_ASN_RANAP UE_ASN_RNSAP UE_ASN_RRC UE_ASN_NBAP UE_GENERAL UE_IU_IF bus_send bus_receive bus_send bus_receive bus_send bus_receive bus_send bus_receive trace4 trace1 trace3

85.new tool call drop analysis: flowfilter.pl **:ws4264@/net/wl7266/tmp/20090323> ~/decoder/flowfilter.pl -h ######################### flowfilter 1.0i, 2009-03-11 ######################### Tested with flow.pl V2.0, requires IU_IF or UE_IF_UE traces. This tool doesn't work with flow.awk or RAN flow.pl Options: Default filtering is done on System drops. -ueref -debug -help|h -ueh -rnc !). -color -asn -type CH|PACKET) -file|f -meas ment. <file> print in differnt colors. print only drops with asn-traces. Filter on one specific type of drop. ROAM_UTRANCELL_PMNOSYSTEMRABRELEASE(SPEE read from file. Skipping everything that contain measure Filter by one specific ueref. Debug mode. Help. Filter by UEH_Exception code. Filter by RNC_Exception code.(Not tested

<UEH Exception code> <RNC Exception code>

86. RNC UE Context History Buffer Purpose: to find out what events led to a UEH exception The last 25 events of each call are logged in a buffer, eg RAB transitions, hand overs, etc. Up to 500 calls can be logged simultaneously. When a UEH exception occurs that leads to the call being released, the UE contex t history buffer is printed on bus_send UEH_EXCEPTION. It is also possible to print the UE context history buffer of any call via the traces bus_send on UEHISTORY (non selective) or UE_UEHISTORY.

In this case, the UE context history buffer must be manually printed to TE log w ith the command printuehistory. More information: 90/190 24-10/FCP 103 6503 87.ipdatabase from oss for amos /opt/ericsson/amos/moshell/sitefiles/ipdatabase mobatch in amos : /opt/ericsson/amos/moshell/mobatch 88. cygwin package for telnet/ftp/ssh/sftp: NET:inetutils & NET:openssh (follow: http://cygwin.com/ml/cygwin-xfree/2002-04/msg00035.html) 89. how to create basic package for nodeB 90. cygwin bash, fast way to change to home folder run "cd" only

92. call bash from cmd window C:\cygwin\bin\mintty.exe c:\cygwin\Cygwin.bat 93. grep & egrep tool of cygwin grep LocationArea.*LocationAreaId *.log > ./log1.txt grep -i iur.*lac ./*.log > ./log3.txt egrep -e '^.* LocationArea=.*' *.log > internal.txt egrep -e '^.*ExternalUtranCell=.*' *.log > ExternalUtranCell.txt 94. ls with color ls -color 95. command to search in bash cygwin find / -name make* 96. login to bash (cygwin from window) @echo off C: chdir C:\cygwin\bin bash -l -i 97. delete many file at the same time rm *.bak 98. string concatenation is the operation of joining two character strings endto-end. For example, the concatenation of "snow" and "ball" is "snowball". mgw 10.19.206.165 MGHC06E 99. FIND MSC FROM MSISDN login to msc : eaw NE=MSHC04E

mgtrp:msisdn=84909027348; mgssp:imsi=452010800626537; mgmap:LAI=452-01-22220; !find RNC location! <MGTRP:msisdn=84938892368; ORDERED < COMMAND SESSION SUSPENDED MT MSISDN TO IMSI TRANSLATION DATA MSISDN 84938892368 IMSI 452010800626537 FCODE

100. quick command to filter trace flow, remove ueh exception message cat RSG101E_130530_1204_Call_flow_f.txt | grep -i "\-\-\-" 101. print operate system moshell is running print $uname CYGWIN_NT-6.1-WOW64 E72C59E5BAD684 1.7.18(0.263/5/3) 2013-04-19 10:39 i686 Cygwi n 102. mod2nr(string) Convert a RncModule name into a module number. bp mod 103. get input from moshell script $var = readinput(Please confirm [y/n]: ) if $var !~ ^y return fi 104. Number of counter instances in the last ROP file : RNC11> pmxc 105. call program from perl my $status = system("vi fred.txt"); my $status = system("mobatch ....."); call perl from other program system ( perl 1.pl ); system ( perl 2.pl ); 106. check oss ps -ef | grep -i moshell 107. ls ls --color 108. ghep 2 file cat file1.txt >> file3.txt cat file2.txt >> file3.txt or egrep . * >> ./totalfile.txt 109. rename file/folder in cygwin [~/temp]$ mv 6/ 6_vi 110. create softlink

Creating soft links... ln -s /home/ephucle/decoder/bin/concat_segmented_rlib_traces.pl /home/ephucle/de coder/concat_segmented_rlib_traces.pl ln -s /home/ephucle/decoder/bin/decoder.pl /home/ephucle/decoder/decoder.pl ln -s /home/ephucle/decoder/bin/decoder_ss7 /home/ephucle/decoder/decoder_ss7 ln -s /home/ephucle/decoder/bin/dropFinder.pl /home/ephucle/decoder/dropFinder.p l ln -s /home/ephucle/decoder/bin/eventHistoryDatabase.pl /home/ephucle/decoder/ev entHistoryDatabase.pl ln -s /home/ephucle/decoder/bin/flow.pl /home/ephucle/decoder/flow.pl ln -s /home/ephucle/decoder/bin/flow_ss7 /home/ephucle/decoder/flow_ss7 ln -s /home/ephucle/decoder/bin/flowFilter.pl /home/ephucle/decoder/flowFilter.p l ln -s /home/ephucle/decoder/bin/flowfox.pl /home/ephucle/decoder/flowfox.pl ln -s /home/ephucle/decoder/bin/historyDecoder.pl /home/ephucle/decoder/historyD ecoder.pl ln -s /home/ephucle/decoder/bin/lgParser.pl /home/ephucle/decoder/lgParser.pl ln -s /home/ephucle/decoder/bin/msFlow.pl /home/ephucle/decoder/msFlow.pl ln -s /home/ephucle/decoder/bin/pdr2eth.awk /home/ephucle/decoder/pdr2eth.awk ln -s /home/ephucle/decoder/bin/PmEventSpecification_RBS.xml /home/ephucle/decod er/PmEventSpecification_RBS.xml ln -s /home/ephucle/decoder/bin/postprocess.pl /home/ephucle/decoder/postprocess .pl ln -s /home/ephucle/decoder/bin/ranap_cause_convert.pl /home/ephucle/decoder/ran ap_cause_convert.pl ln -s /home/ephucle/decoder/bin/spEventHistoryDecoder.pl /home/ephucle/decoder/s pEventHistoryDecoder.pl ln -s /home/ephucle/decoder/bin/teSummary.pl /home/ephucle/decoder/teSummary.pl ln -s /home/ephucle/decoder/bin/uetr2uetrXplorer.awk /home/ephucle/decoder/uetr2 uetrXplorer.awk ln--help for help 111. mom[abcdfloprtux] [<moclass/struct/enum>] [<attribute/action>] [<attr-type> ] [<attr-flags>] [<description>] 112. !!! Please refer to README chap 3.3 (or "h syntax") for more info on how to set values for each specific attribute type (eg Struct, array of MoRef, array o f Struct, etc). 113. draw web pmxw utrancell=iub-6-1 pmTotNoRrcConnectReq$ -m 20 114. pstool list 115. ceds, cedg: cell data ceds: state and supported features of each UtranCell. Read from MO data on Utran Cell and children. cedg: state and geographical coordinates of each UtranCell. Read from MO data on UtranCell and children. feed into http://maps.google.com/maps?q= ------------------------------------------------------------------------------------------------------------------------------------------Mod UtranCell CFRPHEMU Antenna and Cell Coordinates, feed into http://map s.google.com/maps?q= ------------------------------------------------------------------------------------------------------------------------------------------21 CTU20847 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2424,-73.14 0621 41.2157,-73.149569 41.1996,-73.179159 41.2016,-73.215508

21 5508 21 4885 21 0621

CTU20848 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2016,-73.21 41.2208,-73.241665 41.2482,-73.245378 41.2710,-73.224885 CTU20849 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2710,-73.22 41.2785,-73.189759 41.2672,-73.156478 41.2424,-73.140621 CTV20841 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2424,-73.14 41.2157,-73.149569 41.1996,-73.179159 41.2016,-73.215508

116. lh mod procload: check load cause by trace 117. pset (uetr& gpeh) 118, upgrade amos put moshell. zip to /tmp cd /tmp unzip moshell.zip bash moshell_install -a 119. Print all drift contexts for softhandover uerd 120.A random UE trace for any single UE in the whole node RNC26> lh mod uerandtrace on -cell -all;uerandtrace max 1 flowlog: see detail mesasge in flow 121. how to read file (with update status from OSS/linux) tail -1000f neadStatus.log.yin 122. use tip for clear the screen in script #print "\033[2J";#clear screen #print "\033[0;0H"; #jump to 0,0 123. awk advance print all text file awk '{print}' ./content.txt or awk '{print $0}' ./content.txt print frist colume of each line awk '{print $2}' ./content.txt 124. rnc restart command, coli, or telnet mode restartObj me coldwtest restartObj me cold restartObj me warm" 125.how to use concat tool in decoder cat ./RSGBT1E_Cipher_0636_310713.log | ~/decoder/concat_segmented_rlib_traces.p l | tee ./RSGBT1E_Cipher_0636_310713__concat.txt 126. selection file \var\opt\ericsson\nms_smo_srv\smo_file_store\Selection

127. cwdcmd ipf ist_run istdata istlog ll llr sck smtool ypmake echo -n "^[]0;${user}@${HOST}:${cwd}^G" cd /etc/opt/ericsson/nms_cif_ist/ipf /opt/ericsson/sck/bin/ist_run cd /var/opt/ericsson/nms_cif_ist/data cd /var/opt/ericsson/nms_cif_ist/log ls -al ls -altr cd /opt/ericsson/sck/bin /opt/ericsson/nms_cif_sm/bin/smtool (cd /var/yp;make)

128. The longitude of the sector. If X = longitude in degrees (-180 to 180), the value is calculated by inserting X into the following formula: (X/360) 16777216 The latitude of the sector. If X = latitude in degrees (0 to 90), the value is calculated by inserting X int o the following formula: (X/90) 8388608 http://www.gpsvisualizer.com/map_input?form=googleearth cedg: state and geographical coordinates of each UtranCell. Read from MO data on UtranCell and children. feed into http://maps.google.com/maps?q= 129. command to check MP load lhsh 000500 capi tot lhsh 000500 capi prio lhsh 000500 capi type pri ** lhsh 000500 capi core all lhsh 000500 capi peak lhsh 000500 pm_scanner_status lhsh 000500 te log read

130. vswr lh ru fui get vswr 130. how to check call drop for a cell Monitor Speech Drop RBTPT1E> pmxh utrancell.*ldda24 pmNoSystemRabReleaseSpeech|pmNoNormalRabReleaseS peech pmNoNormalRabReleaseSpeech: normal pmNoSystemRabReleaseSpeech: abnormal (drop) SpchDrop = 100 * pmNoSystemRabReleaseSpeech / (pmNoNormalRabReleaseSpeech + p

mNoSystemRabReleaseSpeech) SpchCCSR = SpchAccess * (100 - SpchDrop) / 100 Monitor HS DROP HsDrop = 100 * (pmNoSystemRbReleaseHs) / (pmNoSystemRbReleaseHs + pmNoNorma lRbReleaseHs + pmNoSuccRbReconfOrigPsIntDch + pmPsIntHsToFachSucc) NoHsRel = pmNoSystemRbReleaseHs + pmNoNormalRbReleaseHs NoAbnormalHsRel = pmNoSystemRbReleaseHs + 0 how monitor CS+HS counter at them same time pmxh utrancell.*ldda24 pmNoSystemRabReleaseSpeech|pmNoNormalRabReleaseSpeech|pmN oSystemRbReleaseHs|pmNoNormalRbReleaseHs -m 0.5 pmr -m 0.5 -r 12,16 | grep -i ldda24 Monitor RRC pmTotNoRrcConnectReq @ MO Class: [UtranCell] pmTotNoRrcConnectReqSuccess @ MO Class: [UtranCell] UtranCell=5HN8611 pmTotNoRrcConnectReqCs UtranCell=5HN8611 pmTotNoRrcConnectReqCsSucc RRC Connection Request rejected due to Admission Control UtranCell=5HN8611 pmNoRrcReqDeniedAdm RAB HSDPA pmNoRabEstablishAttemptPacketInteractiveHs MO Class: [UtranCell] pmNoRabEstablishSuccessPacketInteractiveHs MO Class: [UtranCell] 132. RNC LAB/CPP LAB https://wcdma-iov.rnd.ki.sw.ericsson.se/cgi-bin/nodeInfo.pl 133. telnet restart command: reload (warm) restartObj me coldwtest restartObj me warm 134. lhsh lhsh lhsh lhsh lhsh cell trace 010800 uerandtrace on -cell cid x 010800 uerandtrace max 5 010800 te e bus_send bus_receive UE_ASN_RRC 010800 te e bus_send bus_receive UE_ASN_NBAP 010800 te e all UEH_EXCEPTION

lhsh 010800 te e all ADMISSION lhsh 010800 te e all ADMISSION_CELL lhsh 010800 te e all ADMISSION_REJECT_CELL lhsh 010800 te e trace6 trace7 trace3 trace1 CONGESTION_CELL lhsh 010800 te e trace6 trace7 trace3 trace1 SOFT_CONGESTION_CELL lhsh 010800 te e bus_send bus_receive UE_NBAP_RL_HANDLING lhsh 010800 te e all RADIOLINK_REJECT 135. UEH web page - common Exception handler https://wcdma-commonexception.rnd.ki.sw.ericsson.se/pages/exceptions.jsp 136. COMPLETE MOM parsemom /home/ephucle/moshell/jarxml/RNC_NODE_MODEL_N_1_410_COMPLETE.xml

137. set_check #============================================================================== # Consistency check on the Set command # * 0 = no parameter consistency check is done before performing a set operation # * 1 = Prints an extra warning on the set command when trying to set an attribu te to a value different to the recommended value # * 2 = Same as 1, and an exception is given when trying to set an Ericsson Inte rnal parameter to a value different than the recommended value. The list of Eric sson Internal parameters can be printed from the complete MOM with command "momd . . . ericsson" # The recommended values are stored in the files moshell/commonjars/pm/PARAM* an d depend on the node type and SW release # Additional recommended values can be stored in the file specified in the userv ariable custom_param_file #============================================================================== 138 exeption tool http://utran01.au.ao.ericsson.se/utranwiki/ToolsInformation/UsefulScriptsAndHack s#exceptiontools http://newtran01.au.ao.ericsson.se/~econkel/tools/ 139. How to use Flowfox cat ./RSG011E_130906_0115_cipher_d.txt | ~/decoder/decoder.pl --w12b | ~/decoder /flowfox.pl | tee ./RSG011E_130906_0115_cipher_followfox.html 140. dbc: cannot run in amos download CV by cvget and database check by: dbc <db.dat>|<cv.zip> 141. dBm to W (http://www.rapidtables.com/convert/power/dBm_to_Watt.htm): Pw=1/1 000* 10^(Pdbm/10) 142. pmr & pmx command pmr -m 7 -r 12-16 | grep -i 'ldda24\|ldbl11' ==> cannot run yet pmr -s 20131016.0145 -e 20131016.0300 -r 14-22,37-41,71 | grep -i ptpt39 pmxh -s 20131016.0145 -e 20131016.0300 utrancell.*ptpt39 pmNoSystemRabReleaseSpe ech|pmNoNormalRabReleaseSpeech 143. Find IP of all node in OSS: /opt/ericsson/ddc/util/bin/listme 144. all the processes running on OSS system: ps elf prstat: same ps but continually updates the display of information on your scree n vmstat provides a convenient summary of system activity as well 145. C windowns drive path: /cygdrive/c/