HEAT REJECTION

HEAT REJECTION AND OPERATING DATA


MODEL L7042GSI WITH OR WITHOUT ESM
130 F INTERCOOLER WATER TEMPERATURE
STOICHIOMETRIC AIR/FUEL RATIO

POWER
(BHP)

BRAKE SPECIFIC
FUEL CONSUMPTION
(BTU/BHP-HR)

FUEL CONSUMPTION
(BTU/HR) X 1000

HEAT TO
JACKET WATER
(BTU/HR) X 1000

HEAT TO
LUBE OIL
(BTU/HR) X 1000

HEAT TO
INTERCOOLER
(BTU/HR) X 1000

ENGINE SPEED RPM

BMEP
(psi)

600

700

800

900

1000

1100

172

917

1070

1223

1376

1528

1681

1834

152

811

946

1081

1216

1351

1486

1621

138

739

862

985

1108

1232

1355

1478

125

667

778

889

1000

1111

1222

1333

100

533

622

711

800

889

978

1067

75

400

467

533

600

667

733

800

50

267

311

356

400

444

489

533

172

7123

7160

7197

7282

7366

7484

7602

152

7249

7285

7320

7401

7482

7603

7723

138

7355

7390

7424

7502

7581

7703

7824

125

7484

7517

7550

7625

7700

7824

7948

100

7815

7844

7873

7940

8006

8135

8265

75

8367

8389

8412

8464

8517

8655

8792

50

9471

9480

9489

9513

9538

9693

9848

172

6530

7665

8800

10030

11255

12600

13940

152

5875

6895

7915

9010

10110

11315

12520

138

5435

6370

7310

8320

9335

10445

11560

125

4990

5850

6710

7635

8555

9575

10595

100

4170

4885

5600

6360

7115

7965

8815

75

3345

3915

4485

5080

5680

6355

7035

50

2525

2950

3375

3805

4240

4745

5250

172

1760

2155

2550

2965

3380

3755

4125

152

1625

1980

2330

2700

3075

3410

3745

138

1530

1855

2185

2525

2865

3175

3490

125

1439

1735

2035

2345

2655

2945

3230

100

1267

1510

1760

2015

2270

2515

2755

75

1095

1289

1483

1685

1885

2080

2275

50

923

1065

1207

1354

1500

1650

1800

172

231

264

296

317

338

360

382

152

215

246

277

298

319

341

363

138

204

234

264

285

306

328

349

125

193

222

251

272

293

315

336

100

173

200

227

248

269

290

312

75

153

178

203

224

245

266

287

50

133

156

179

200

222

242

263

172

53

88

122

167

212

307

403

152

32

58

83

117

151

221

291

138

21

41

61

88

116

171

225

125

11

26

42

63

85

127

169

1200

100

-2

15

28

41

64

86

75

-8

-5

-1

13

23

33

50

-7

-7

-6

-3

10

Page 1 of 6

HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


130 F INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S
6124-57

HEAT REJECTION

13

HEAT REJECTION AND OPERATING DATA


MODEL L7042GSI WITH OR WITHOUT ESM
130 F INTERCOOLER WATER TEMPERATURE
STOICHIOMETRIC AIR/FUEL RATIO

HEAT TO
RADIATION
(BTU/HR) X 1000

TOTAL ENERGY
IN EXHAUST
(BTU/HR) X 1000

EXHAUST TEMP
AFTER TURBINE
( 50 F)

INDUCTION
AIR FLOW
(SCFM)

EXHAUST
GAS FLOW
(LBS/HR)

ENGINE SPEED RPM

BMEP
(psi)

600

700

800

900

1000

1100

172

548

568

588

600

611

646

681

152

480

509

539

562

584

622

660

138

446

479

511

538

566

605

645

125

420

453

487

517

546

588

631

100

385

417

448

479

509

555

601

75

359

386

413

441

469

517

566

50

330

353

376

400

425

473

521

1200

172

1670

1940

2210

2545

2880

3290

3705

152

1393

1660

1925

2240

2550

2945

3335

138

1242

1496

1750

2040

2335

2710

3085

125

1112

1347

1585

1850

2120

2475

2825

100

900

1093

1286

1505

1725

2030

2335

75

702

847

993

1162

1331

1580

1825

50

495

597

699

814

930

1111

1292

172

1054

1070

1086

1091

1096

1121

1145

152

980

1007

1035

1053

1072

1104

1135

138

942

974

1006

1030

1055

1090

1125

125

911

946

980

1009

1037

1075

1113

100

867

903

938

969

1000

1042

1085

75

829

862

895

926

956

1003

1049

50

783

814

845

875

905

955

1005

172

1240

1460

1675

1905

2140

2395

2650

152

1110

1300

1495

1700

1910

2135

2365

138

1020

1195

1375

1565

1750

1960

2170

125

930

1095

1255

1425

1600

1790

1980

100

770

905

1035

1175

1315

1475

1630

75

615

715

820

930

1040

1165

1290

50

460

535

610

690

770

860

950

172

5655

6635

7620

8685

9745

10910

12070

152

5050

5925

6800

7745

8690

9730

10765

138

4650

5450

6255

7120

7985

8935

9890

125

4245

4980

5715

6500

7285

8150

9020

100

3515

4120

4720

5360

6005

6720

7435

75

2795

3275

3750

4245

4745

5310

5880

50

2090

2440

2795

3150

3510

3930

4350

Page 2 of 6

HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


130 F INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S
6124-57

HEAT REJECTION
NOTES:
1.

2.

3.
4.

All data are based on standard conditions of 29.54 inches Hg. barometric pressure, 77 F ambient and induction air
temperature, 30% relative humidity (0.3 inches Hg. water vapor pressure) and 180 F engine jacket water outlet
temperature.
Data are average values at the standard conditions and will vary for individual engines and with operating and ambient
conditions. An adequate reserve should be used for cooling system or heat recovery calculations. See also Cooling
System Guidelines S6699-7.
For heat rejection changes due to engine jacket water outlet temperature different from standard (Note 1), refer to
S7613-3.
Exhaust flow at nominal 29.54 inches Hg. atmospheric pressure:
Flow rate:

5.
6.

ACFM =

o
o
(Exh. Flow, lb/hr) x (Exh. Temp. F + 460 )
2250

Stoichiometric, Lambda = 1.0, air/fuel ratio.


Reference C278-J.

Page 3 of 6

HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


130 F INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S
6124-57

HEAT REJECTION

13

METRIC
HEAT REJECTION AND OPERATING DATA
MODEL L7042GSI WITH OR WITHOUT ESM
54 C INTERCOOLER WATER TEMPERATURE
STOICHIOMETRIC AIR/FUEL RATIO

POWER
(kW)

BRAKE SPECIFIC
FUEL CONSUMPTION
(kJ/kWh)

FUEL
CONSUMPTION
(kW)

HEAT TO
JACKET WATER
(kW)

HEAT TO
LUBE OIL
(kW)

HEAT TO
INTERCOOLER
(kW)

ENGINE SPEED RPM

BMEP
(bar)

600

700

800

900

1000

1100

1200

11.86

684

798

912

1026

1139

1254

1368

10.48

605

705

806

907

1008

1108

1209

9.55

551

643

735

826

919

1010

1102

8.62

497

580

663

746

829

911

994

6.90

398

464

530

597

663

729

795

5.17

298

348

398

447

497

547

597

3.45

199

232

265

298

331

365

398

11.86

10078

10138

10183

10316

10421

10604

10756

10.48

10256

10314

10357

10485

10587

10772

10927

9.55

10407

10462

10504

10627

10726

10914

11070

8.62

10589

10642

10682

10800

10895

11086

11245

6.90

11058

11104

11139

11244

11328

11527

11693

5.17

11838

11874

11901

11984

12050

12263

12440

3.45

13400

13414

13425

13464

13495

13734

13934

11.86

1914

2246

2579

2939

3299

3692

4086

10.48

1722

2021

2319

2641

2963

3316

3670

9.55

1592

1868

2143

2439

2735

3061

3388

8.62

1462

1715

1967

2237

2507

2807

3106

6.90

1222

1431

1641

1863

2086

2335

2584

5.17

981

1148

1315

1489

1664

1863

2061

3.45

740

864

989

1116

1242

1391

1539

11.86

516

632

748

869

991

1100

1209

10.48

476

580

683

792

901

999

1098

9.55

449

544

640

740

840

931

1022

8.62

422

509

596

687

779

863

947

6.90

371

443

515

590

666

736

807

5.17

321

378

434

494

553

610

667
528

3.45

271

312

354

397

440

484

11.86

68

77

87

93

99

105

112

10.48

63

72

81

87

93

100

106

9.55

60

69

77

84

90

96

102

8.62

57

65

74

80

84

92

98

6.90

51

59

67

73

79

85

91

5.17

45

52

60

66

72

78

84

3.45

39

46

53

59

65

71

77

11.86

16

26

36

49

62

90

118

10.48

10

17

24

34

44

65

85

9.55

12

18

26

34

50

66

8.62

12

19

25

37

49

6.90

-1

12

19

25

5.17

-2

-1

10

3.45

-2

-2

-2

-1

3
Page 4 of 6

METRIC
HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


54 C INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S
6124-57

HEAT REJECTION

METRIC
HEAT REJECTION AND OPERATING DATA
MODEL L7042GSI WITH OR WITHOUT ESM
54 C INTERCOOLER WATER TEMPERATURE
STOICHIOMETRIC AIR/FUEL RATIO

HEAT TO
RADIATION
(kW)

TOTAL ENERGY
IN EXHAUST
(kW)

EXHAUST TEMP
AFTER TURBINE
( 30 C)

INDUCTION
AIR FLOW
3
(nm /h)

EXHAUST
GAS FLOW
(kg/h)

ENGINE SPEED RPM

BMEP
(bar)

600

700

800

900

1000

1100

1200

11.86

161

166

172

176

179

189

200

10.48

141

149

158

165

171

182

193

9.55

131

140

150

158

166

177

189

8.62

123

133

143

151

160

172

185

6.90

113

122

131

140

149

163

176

5.17

105

113

121

129

137

152

166

3.45

97

103

110

117

125

139

153
1086

11.86

489

569

648

746

844

965

10.48

408

486

564

656

748

863

978

9.55

364

438

513

599

684

794

904

8.62

326

395

464

543

621

725

828

6.90

264

320

377

441

506

595

684

5.17

206

248

291

341

390

462

535

3.45

145

175

205

239

272

325

379

11.86

568

577

585

588

591

605

618

10.48

527

542

557

567

578

595

613

9.55

505

523

541

555

568

588

607

8.62

488

508

527

543

558

579

601

6.90

464

484

503

520

538

561

585

5.17

443

461

479

496

513

539

565

3.45

417

434

452

468

485

513

541

11.86

1871

2196

2520

2872

3224

3609

3993

10.48

1670

1960

2249

2561

2874

3216

3559

9.55

1536

1802

2068

2353

2639

2954

3269

8.62

1403

1646

1888

2147

2407

2694

2981

6.90

1161

1360

1560

1771

1982

2219

2456

5.17

923

1080

1237

1402

1566

1753

1940

3.45

690

805

921

1039

1158

1296

1434

11.86

2565

3011

3456

3938

4421

4948

5475

10.48

2292

2689

3085

3514

3942

4412

4883

9.55

2108

2473

2837

3229

3621

4053

4485

8.62

1927

2259

2591

2947

3304

3698

4092

6.90

1595

1868

2142

2432

2723

3048

3373

5.17

1269

1485

1700

1926

2152

2409

2666

3.45

948

1108

1267

1429

1592

1782

1972

Page 5 of 6
METRIC
HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


54 C INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S
6124-57

HEAT REJECTION
NOTES:
1.
2.

3.
4.

All data are based on standard conditions of 100 kPa barometric pressure, 25 C ambient and induction air
temperature, 30% relative humidity (1 kPa water vapor pressure) and 82 C engine jacket water outlet temperature.
Data are average values at the standard conditions and will vary for individual engines and with operating and ambient
conditions. An adequate reserve should be used for cooling system or heat recovery calculations. See also Cooling
System Guidelines S6699-7.
For heat rejection changes due to engine jacket water outlet temperature different from standard (Note 1), refer to
S7613-3.
Exhaust flow at nominal 100 kPa atmospheric pressure:

Flow rate:
5.
6.

13

m3 /hr =

o
o
(Exh. Flow, kg/hr) x (Exh. Temp. C + 273 )

332.96

Stoichiometric, Lambda = 1.0, air/fuel ratio.


Reference C278-J.

Page 6 of 6
METRIC
HEAT REJECTION AND OPERATING DATA

MODEL L7042GSI WITH OR WITHOUT ESM


54 C INTERCOOLER WATER TEMPERATURE

EN:

142568

DATE:

7/08

Ref.
S