CALCULO INSTALACIN SOLAR FOTOVOLTAICA AISLADA DE RED USO ESPECIFICADO EN TABLA CONSUMOS
CONSUMOS DAS DE USO (1-7) POTENCIA W a 230 V UNIDADES ENERGIA (Ah/da) ENERGIA (Wh/da)

RECEPTOR SALN COMEDOR COCINA DORMITORIO ALUMBRADO EXTERIOR ILUMINACIN BAO PASILLOS

SIMULTANEIDAD

HORAS

100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00%

3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 7.00 3.00 3.00

18 18 11 9 11 11 58 1110 80 15 120 400 800 80 150 375

2 1 4 4 1 0 2 0 1 0 0 0 0 1 0 1

2.00 2.00 0.25 0.25 1.00 0.25 1.00 2.00 4.00 4.00 0.30 0.40 0.25 12.00 14.00 2.00 Nu (10-25%) N'u

1.29 0.64 0.20 0.16 0.20 0.00 2.07 0.00 5.71 0.00 0.00 0.00 0.00 40.00 0.00 13.39 63.66 Ah/da 15.00% 73.21 Ah/da

30.86 15.43 4.71 3.86 4.71 0.00 49.71 0.00 137.14 0.00 0.00 0.00 0.00 960.00 0.00 321.43 1527.86 Wh/da 15.00% 1757.04 Wh/da

TELEVISOR COLOR ELECTRODOMESTICOS Y OTROS RADIO BATIDORA LAVADORA MICROONDAS FRIGORIFICO CONGELADOR EXTRACTOR HUMOS

100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00% 100.00%

NECESIDADES DIARIAS USUARIO PORCENTAJE DE SEGURIDAD NECESIDADES DIARIAS USUARIO CORREGIDAS

COEFICIENTE DE PERDIDAS TOTALES DE LA INSTALACIN K T


KA AUTODESCARGA DE LA BATERIA A 20C KB RENDIMIENTO DE LA BATERIA A 20C KC RENDIMIENTO DEL CONVERTIDOR Vcc/Vca KR RENDIMIENTO DEL REGULADOR DE CARGA KX OTRAS PERDIDAS, JOULE, U, ETC.. DAUT DAS DE AUTONOMA Pd PROFUNDIDAD DESCARGA BATERIA KT 0.005 0.05 0.05 0.01 0.05 3.00 0.50 0.81

CONSUMO MAXIMO A PROPORCIONAR POR PANELES FOTOVOLTAICOS C max


NECESIDADES DIARIAS USUARIO CORREGIDAS COEFICIENTE PERDIDAS TOTALES INSTALACIN TENSIN Vcc BATERIA N'u KT Vcc Cmax Cmax 1757.04 Wh/da 0.81 24.00 Vcc 2156.40 Wh/da 89.85 Ah/da

Podeis contactarnos a travs de: ramirezcuevascb@gmail.com o en nuestra web: www.ramirezcuevas.es

Telfonos: 647703894 647703895

www.ramirezcuevas.es

Pgina 2 de 4

ENERGIA PANEL FOTOVOLTAICO Ep MDULO SOLARIA S5M185


POTENCIA MXIMA DEL PANEL FOTOVOLTAICO (W p) HORAS PICO SOLAR APROVECHABLES DA (HPS) RENDIMIENTO DEL PANEL p TENSIN MXIMA DEL PANEL FOTOVOLTAICO (Vp) Ep Ep 185.00 Wp 3.30 90.00% 36.00 Vcc 549.45 Wh/da 15.26 Ah/da

CAMPO SOLAR FOTOVOLTAICO NMERO DE PANELES FOTOVOLTICOS NECESARIOS PANELES A INSTALAR ELEGIDOS DISEADOR
POTENCIA DEL CAMPO SOLAR (Wp)

4.00 UD 4.00 UD
30.84 A U (%) < 3% 2.87%

740.00 Wp
INTENSIDAD (A)

AMPERAJE CAMPO SOLAR (A)

CLCULO CADA DE TENSIN CONDUCTORES CAMPO SOLAR-REGULADOR U (%)


LONGITUD (m): TIPO CONDUCTOR 10.00 m 56 30.84 A 16.00 mm

SECCIN CONDUCTOR (mm)

REGULADOR DE CARGA AMPERAJE MNIMO DEL REGULADOR DE CARGA ELEGIR REGULADOR DE CARGA

31.00 A 60.00 A
60.00 A 25.00 mm

REGULADOR SOLAR DE CARGA PWM 12-24 Vcc 35 A, XANTREX. REF.: 2414C35

AMPERAJE ELEGIDO PARA EL REGULADOR DE CARGA CLCULO CADA DE TENSIN CONDUCTORES REGULADOR-BATERIAS U (%)
LONGITUD (m): TIPO CONDUCTOR 2.00 m 56 INTENSIDAD (A) SECCIN CONDUCTOR (mm)

U (%) < 1% 0.71%

INVERSOR ELEGIR INVERSOR W PUNTA MXIMO CONSUMO: FACTOR UTILIZACIN MXIMO:


INVERSOR ONDA SENOIDAL PURA VICTRON ENERGY PHOENIX 12 V/ 3000 VA.

796.00 W 376.88%

W NOMINAL INVERSOR: AMPERAJE NOMINAL MXIMA INVERSOR:

3000.00 W 125.00 A

CLCULO CADA DE TENSIN CONDUCTORES REGULADOR BATERIAS-INVERSOR U (%)


LONGITUD (m): TIPO CONDUCTOR 2.00 m 56 INTENSIDAD (A) SECCIN CONDUCTOR (mm) 125.00 A 25.00 mm

U (%) < 1% 1.49%

CAPACIDAD DEL ACUMULADOR CBAT


CONSUMO MAXIMO A PROPORCIONAR PANELES FOTOVOLTAICOS Cmax DAUT DAS DE AUTONOMA Pd PROFUNDIDAD DESCARGA BATERIA CBAT CBAT ACUMULADOR ELEGIDO (C10 C20) CBAT ELEGIDA 2156.40 Wh/da 3.00 0.50 12938.41 Wh/da 539.10 Ah/da 600.00 Ah

PRUEBA DE LA DESCARGA DIARIA


CONSUMO MAXIMO A PROPORCIONAR PANELES FOTOVOLTAICOS Cmax CAPACIDAD DEL ACUMULADOR CBAT PROFUNDIDAD DE DESCARGA DISEO PD DESCARGA DIARIA PROFUNDIDAD DE DESCARGA PD USO 89.85 Ah/da 600.00 Ah/da 50.00% 14.98% 44.93%

Podeis contactarnos a travs de: ramirezcuevascb@gmail.com o en nuestra web: www.ramirezcuevas.es

Telfonos: 647703894 647703895

www.ramirezcuevas.es

Pag.: 3 de 4

AWG 18 17 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0

mm 0.75 1.00 1.50 2.50 4.00 6.00 10.00 16.00 25.00 35.00 50.00 55.00 70.00 95.00

CAIDAS DE TENSIN ELEMENTOS MXIMA PANELES-REGULADOR 3.00 REGULADOR-ACUMULADOR 1.00 ACUMULADOR-INVERSOR 1.00 LINEA ILUMINACIN 3.00 OTROS EQUIPOS 5.00

Podeis encontrarnos en: Bailn 6, Local (13500) Puertollano CIUDAD REAL

Telfonos: 647703894 647703895

www.ramirezcuevas.es

Pag.: 4 de 4

CAIDAS DE TENSIN RECOMENDADA 1.00 0.50 1.00 3.00 3.00