Вы находитесь на странице: 1из 32

Split System

Heat Pump
Product Data

XE 1000
TWR012-060

1 – 5 Tons

PUB. NO. 22-1624-05-0199 (EN)


General
Features

Split System Heat Pump Manufacturing Control


Trane’s exclusive control over the design
Units . . . Designed With and manufacturing of all major
Your Needs In Mind. components is unique in the industry.
This approach assures us total control
TWR split systems represent a new
over both the quality and reliability of
approach to designing products for The
these components. It also allows us to
Trane Company. The design team’s
custom match components to deliver the
mission is “. . . to bring a system to the
best in split system performance.
marketplace that will meet your job
requirements every time” . . . And at a Designing the Details
competitive price. Careful attention was given to designing
the details — from control wiring to the
Trane’s experienced design team used
access panels. Trane units feature time-
the newest computer technology and an
saving color coded wiring and removable
entirely new manufacturing process to
panels which allow complete access to
develop a new standard in split systems.
all major components and controls. All
Couple the Trane reputation for quality
outdoor units feature external high and
and reliability in split system heat pumps
low pressure gauge ports for easy
with improvements in efficiency, flexibility
diagnosing and servicing of the unit.
and installation ease . . . and you have
systems that prove “It’s Hard to Stop a UL Listed
Trane.” Trane meets or exceeds all nationally
recognized agency safety and design
standards. Each unit is UL designed,
approved, and labeled in accordance to
UL Standards 1995, including approval
for use in Canada. Each unit is rated in
accordance with ARI Standard 210/240
and 270.

© American Standard Inc. 1999 2 Pub. No. 22-1624-05-0199 (EN)


Contents

Feature Summary 2
Features and Benefits 4
Optional Equipment
Low Outdoor Ambient Cooling
Standard Capacity Rating Conditions
Selection Procedure 6
Model Number Nomenclature
General Data 7
TWR012C100A
TWR018C100A
TWR024C100A
TWR030C100A
TWR036C100A
TWR042C100B
TWR048D100A
TWR060D100A
Ratings With Auxiliary Devices 22
Electrical Data 28
Dimensions 31
Mechanical Specification Options 32

Pub. No. 22-1624-05-0199 (EN) 3


Features
and Benefits

• High efficiency Climatuff® compressor • Corrosion protection


• Spine Fin™ aluminum outdoor coil • Liquid line filter-drier
• Solid state electronic demand defrost • Single side service access
control • Low ambient cooling to 55°F as
• Braze refrigerant connections manufactured
• Multi-use service valves • Low ambient cooling to 40°F with EDC
• Steel cabinet, full coil protection accessory AY28X084

• Powder paint covers uniformly to resist • Low ambient cooling to 30°F with EDC
rust & corrosion accessory AY28X084 and TXV
• Attractive silver gray color • IPR/IOL motor overload protectors

• Top cover/motor mount/grille combined • 5-year limited warranty on


compressor & coil, 1 year on parts
• Fast draining base pan assembly
• Optional extended warranties
• Compressor heat provided (1-3½ tons)

4 Pub. No. 22-1624-05-0199 (EN)


Features
and Benefits

Optional Equipment
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [✓ ✓ ] indicates accessories included).
Indoor Thermostats — XT 501 Automatic Programmable Thermostat .................................................................... TAYSTAT501 [ ]
XT 500 Elec. Setback Thermostat ....................................................................................... TAYSTAT500 [ ]
Programmable 3Htg/2CIg Thermostat ............................................................................. BAYSTAT038A [ ]
Remote Temperature Sensor .......................................................................................... BAYSENS025A [ ]
Automatic Changeover Thermostat ..................................................................................... BAY28X138 [ ]
Manual Changeover Thermostat ..................................................................................... BAYSTAT239A [ ]
Manual Changeover Thermostat ..................................................................................... BAYSTAT240A [ ]
Outdoor Thermostat (Adjustable) ........................................................................................................................... TAYSTAT250A [ ]
Evaporator Defrost Control Kit ..................................................................................................................................... AY28X084 [ ]
Indoor Fan Delay Relay Kit ....................................................................................................................................... BAY24X045 [ ]
Quick Start Kit (TWR012-042C) ........................................................................................................................... BAYKSKT250A [ ]
Quick Start Kit (TWR048-060D) ........................................................................................................................... BAYKSKT252A [ ]
Crank Case Heater Kit (TWR048D) 2 ................................................................................................................ BAYCCHT200A [ ]
Crank Case Heater Kit (TWR060D) 2 ................................................................................................................ BAYCCHT201A [ ]
Line Insulation Kit ...................................................................................................................................................... BAYINS001 [ ]
5 Minute Delay Relay 1 ....................................................................................................................................... TAYASCT501A [ ]
Snow Legs ........................................................................................................................................................... BAYLEGS001A [ ]
Isolators (4) ............................................................................................................................................................... BAYISLT100 [ ]
Thermostat Cover 1 ................................................................................................................................................. BAY28X190 [ ]
1 Do not use with programmable thermostats
2 When inner connecting lines exceed the standard 60 linear ft. of length refer to the Application Guide 22-3238-02

BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)
5/8" ODM (90° bend, one end), 5/8" and 1/4" tubing ........................................................................................... TAYREFLN1__* [ ]
3/4" ODM (90° bend, one end), 3/4" and 5/16" tubing ......................................................................................... TAYREFLN2__* [ ]
7/8" ODM (90° bend, one end), 7/8" and 3/8" tubing ........................................................................................... TAYREFLN3__* [ ]
1-1/8" ODM (90° bend, one end), 7/8" and 3/8" tubing ........................................................................................ TAYREFLN4__* [ ]
* Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number.
Example: TAYREFLN220

Low Outdoor Ambient Cooling


Low Ambient As Evaporator
Cooling Manufactured Defrost Control
FCCV Accutron 55°F 40°F
Thermal Expansion Valve (TXV) 55°F 30°F

A.R.I. Standard Capacity Rating Conditions


A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air
entering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor
coil. (C) Low Temperature Heating 17°F. D.B., 15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Rated
indoor airflow for heating is the same as for cooling.
A.R.I. STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95°F. outdoor air.

Pub. No. 22-1624-05-0199 (EN) 5


Selection
Procedure

Model Number Nomenclature


1 2 3 4 5 6 7 8 9 10 11
T W R 0 4 2 C 1 0 0 B

PRODUCT TYPE
Split Cooling -
TTA, TTB, TTN, TTR, TTP, TTX, TTY, TTZ
Split Heat Pump -
TWA, TWN, TWP, TWR, TWX, TWY, TWZ MINOR DESIGN
Package Cooling - MODIFICATION
TCC, TCH, TCD, TCX, TCM, TCY
Package Heat Pump - DCY, WCC, WCD,
WCH, WCM, WCX, WCY, WCZ SECONDARY FUNCTIONS
Air Handler - TWV, TWH, TWE, TWG, TVF Gas/Electric - Gas Heating
Gas/Electric - YCC, YCD, YCH, YCX, YCY, YCZ Furnaces - Cooling Airflow
Coils - TXA, TXC, TXE, TXF, CCB, CUB Air Handlers - Flow Control

SPLIT SYSTEM COUPLING SYSTEMS POWER SUPPLY AND FUEL


1 - 5 TONS
0 - Brazed
MAJOR DESIGN MODIFICATION
PRIMARY CAPACITY
Example: 042 = 42 MBTUH = 3.5 Tons

6 Pub. No. 22-1624-05-0199 (EN)


General TWR012C100A
Data

OUTDOOR UNIT 12 TWR012C100A


NOISE RATING (DECIBELS) 2 78 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 200/230/01/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 11
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
15
15
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 8.0 - 45
BRCH. CIR. SELEC. CUR. AMPS 8.0
OUTDOOR FAN — TYPE PROPELLER
DIA. (IN.) - NO. USED 14 - 1
SPLIT SYSTEM
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 1084 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/15
MOTOR SPEED R.P.M. 1650
4 STANDARD AIR - DRY COIL - OUTDOOR
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 0.50 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 9.38 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 4 LB., 10 OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 5/8
LINE SIZE - IN. O.D. LIQ. 6 1/4
FCCV — RESTRICTOR ORIFICE SIZE 0.049
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 25 X 25-1/2 X 21-3/4
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 146
NET (LBS.) 139
OUTDOOR UNIT WITH AIR HANDLERS

TVF018A14 TVF025A14
EXPANSION TYPE FACT INS 49 CHG TO 49
RATINGS (COOLING) 1
BTUH (TOTAL) 15600 15800
BTUH (SENSIBLE) 11300 11400
INDOOR AIRFLOW (CFM) 550 550
SYSTEM POWER (KW) 1.64 1.75
SEER (BTU/WATT-HR.) 10.00 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 14700 14500
SYSTEM POWER (KW) 1.35 1.38
COP 3.20 3.08
HSPF (BTU/WATT-HR.) 6.80 6.80

See page 22 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 7


General TWR018C100A
Data

OUTDOOR UNIT 12 TWR018C100A


1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
NOISE RATING (DECIBELS) 2 78
POWER CONNS. — V/PH/HZ 200/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 11
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
15
15
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 8.0 - 45
BRCH. CIR. SELEC. CUR. AMPS 8.0
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 14 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 1084 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/15 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 1650
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 0.50 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 9.38 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 4 LBS., 13 OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 5/8
LINE SIZE - IN. O.D. LIQ. 6 1/4
FCCV — RESTRICTOR ORIFICE SIZE 0.049
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 25 X 25-1/2 X 21-3/4
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 146
NET (LBS.) 139
OUTDOOR UNIT WITH AIR HANDLERS

TVF018A14 TVF025A14 TWE018C14 TWE024C14 TWG018A14 TWG025A14


EXPANSION TYPE FACT INS 49 CHG TO 49 FACT INS 49 CHG TO 49 FACT INS 49 CHG TO 49
RATINGS (COOLING) 1
BTUH (TOTAL) 17300 17400 16800 16400 16500 16300
BTUH (SENSIBLE) 12900 13400 11600 11400 11600 11800
INDOOR AIRFLOW (CFM) 600 640 600 600 600 610
SYSTEM POWER (KW) 1.74 1.90 1.74 1.74 1.78 1.71
SEER (BTU/WATT-HR.) 10.00 10.10 10.30 10.00 10.00 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 16600 16500 15800 15900 15900 15800
SYSTEM POWER (KW) 1.45 1.47 1.48 1.50 1.52 1.46
COP 3.36 3.28 3.12 3.10 3.06 3.18
HSPF (BTU/WATT-HR.) 7.05 6.90 6.80 6.80 6.80 6.80
OUTDOOR UNIT WITH FURNACES & COILS
TDD080R9V3 TUD080R9V3 TUY080R9V3
+TXC031E5 +TXC031E5 +TXC031E5
EXPANSION TYPE TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 17900 17900 17900
BTUH (SENSIBLE) 13200 13200 13100
INDOOR AIRFLOW (CFM) 600 600 575
SYSTEM POWER (KW) 1.73 1.76 1.75
SEER (BTU/WATT-HR.) 10.90 10.90 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 16000 16100 16000
SYSTEM POWER (KW) 1.30 1.33 1.31
COP 3.62 3.56 3.58
HSPF (BTU/WATT-HR.) 7.50 7.35 7.35

See page 22 for combinations with Auxiliary Devices.

8 Pub. No. 22-1624-05-0199 (EN)


General TWR024C100A
Data

OUTDOOR UNIT 12 TWR024C100A


NOISE RATING (DECIBELS) 2 78 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 200/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 16
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
25
20
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 10.0 - 67
BRCH. CIR. SELEC. CUR. AMPS 12.0
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 18 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 1804 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/8 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 825
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 0.90 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 12.22 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 4-LBS., 13-OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 3/4
LINE SIZE - IN. O.D. LIQ. 6 5/16
FCCV — RESTRICTOR ORIFICE SIZE 0.055
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 25 X 30 X 26-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 170
NET (LBS.) 162
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA025C4 TXA030C4 TXA031C4 TXA035C4 TXC025C4 TXC025D4 TXC030C4


EXPANSION TYPE CHG TO 55 CHG TO 55 CHG TO 55 CHG TO 55 CHG TO 55 CHG TO 55 CHG TO 55
RATINGS (COOLING) 1
BTUH (TOTAL) 23400 24000 24200 24000 23400 23400 24000
BTUH (SENSIBLE) 16200 16600 17600 16600 16200 16200 16600
INDOOR AIRFLOW (CFM) 800 890 890 890 800 800 890
SYSTEM POWER (KW) 2.50 2.58 2.59 2.58 2.50 2.50 2.58
SEER (BTU/WATT-HR.) 10.05 10.05 10.05 10.10 10.05 10.05 10.05
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 22200 22400 22600 22400 22200 22200 22400
SYSTEM POWER (KW) 2.10 2.13 2.10 2.13 2.10 2.10 2.13
COP 3.10 3.08 3.16 3.08 3.10 3.10 3.08
HSPF (BTU/WATT-HR.) 6.80 6.80 6.90 6.80 6.80 6.80 6.80

TXC030D4 TXC031C4 TXC031D4 TXC031E5 TXC035C4 TXC035D4 TXH025A4


EXPANSION TYPE CHG TO 55 CHG TO 55 CHG TO 55 TXV-B CHG TO 55 CHG TO 55 CHG TO 55
RATINGS (COOLING) 1
BTUH (TOTAL) 24000 24200 24200 24800 24000 24000 23200
BTUH (SENSIBLE) 16600 17600 17600 18200 16600 16600 15400
INDOOR AIRFLOW (CFM) 890 890 890 900 890 890 800
SYSTEM POWER (KW) 2.58 2.59 2.59 2.57 2.58 2.58 2.49
SEER (BTU/WATT-HR.) 10.05 10.05 10.05 10.50 10.10 10.10 10.10
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 22400 22600 22600 22800 22400 22400 21800
SYSTEM POWER (KW) 2.13 2.10 2.10 2.08 2.13 2.13 2.17
COP 3.08 3.16 3.16 3.22 3.08 3.08 2.94
HSPF (BTU/WATT-HR.) 6.80 6.90 6.90 7.00 6.80 6.80 6.80

See pages 22 and 23 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 9


General TWR024C100A
Data

OUTDOOR UNIT W/HEAT PUMP COILS OUTDOOR UNIT WITH AIR HANDLERS

TXH033A4 TVF018A14 TVF024A14 TVF025A14 TVF030A14 TVF036A14


EXPANSION TYPE CHG TO 55 CHG TO 55 FACT INS 55 FACT INS 55 CHG TO 55 CHG TO 55
RATINGS (COOLING) 1
BTUH (TOTAL) 24400 23400 24000 23600 24800 25000
BTUH (SENSIBLE) 17600 15800 17100 16900 18700 18900
INDOOR AIRFLOW (CFM) 900 675 800 800 900 900
SYSTEM POWER (KW) 2.61 2.49 2.57 2.51 2.61 2.69
SEER (BTU/WATT-HR.) 10.15 10.30 10.00 10.00 10.45 10.15
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 22600 22000 22200 22600 22600 23000
SYSTEM POWER (KW) 2.10 2.12 2.10 2.07 2.06 2.11
COP 3.16 3.04 3.10 3.20 3.22 3.20
HSPF (BTU/WATT-HR.) 6.85 6.80 6.80 6.95 7.00 6.90
OUTDOOR UNIT WITH AIR HANDLERS

TWE024C14 TWE030C14 TWE036C14 TWG025A14 TWG030A14


EXPANSION TYPE FACT INS 55 CHG TO 55 CHG TO 55 FACT INS 55 CHG TO 55
RATINGS (COOLING) 1
BTUH (TOTAL) 22600 23800 24400 22500 23600
BTUH (SENSIBLE) 15100 17100 17500 15400 16600
INDOOR AIRFLOW (CFM) 800 875 900 800 875
SYSTEM POWER (KW) 2.44 2.57 2.62 2.37 2.55
SEER (BTU/WATT-HR.) 10.15 10.15 10.20 10.00 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 21600 22200 22600 21400 22000
SYSTEM POWER (KW) 2.17 2.11 2.12 2.06 2.14
COP 2.92 3.08 3.12 3.04 3.02
HSPF (BTU/WATT-HR.) 6.80 6.80 6.80 6.80 6.80
OUTDOOR UNIT WITH FURNACES & COILS
TDD080R9V3 TDD080R9V3 TDD100R9V5 TUD080R9V3 TUD080R9V3 TUD100R9V5 TUY080R9V3
+TXC031E5 +TXC036E5 +TXC037E5 +TXC031E5 +TXC036E5 +TXC037E5 +TXC031E5
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 24800 25400 25600 24800 25600 25600 24800
BTUH (SENSIBLE) 17400 18000 18400 17500 18400 18400 17500
INDOOR AIRFLOW (CFM) 775 775 800 800 825 800 800
SYSTEM POWER (KW) 2.33 2.34 2.34 2.36 2.38 2.34 2.35
SEER (BTU/WATT-HR.) 11.80 11.80 11.90 11.80 11.80 11.90 10.70
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 21800 22000 22000 22000 22200 22000 22000
SYSTEM POWER (KW) 1.90 1.84 1.83 1.93 1.87 1.83 1.93
COP 3.36 3.50 3.52 3.34 3.48 3.52 3.34
HSPF (BTU/WATT-HR.) 7.25 7.50 7.50 7.20 7.35 7.50 7.20

TUY080R9V3
+TXC036E5
EXPANSION TYPE TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 25400
BTUH (SENSIBLE) 18200
INDOOR AIRFLOW (CFM) 800
SYSTEM POWER (KW) 2.36
SEER (BTU/WATT-HR.) 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 22200
SYSTEM POWER (KW) 1.87
COP 3.48
HSPF (BTU/WATT-HR.) 7.35

See pages 22 and 23 for combinations with Auxiliary Devices.

10 Pub. No. 22-1624-05-0199 (EN)


General TWR030C100A
Data

OUTDOOR UNIT 12 TWR030C100A


NOISE RATING (DECIBELS) 2 80 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 200/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 18
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
30
30
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 13.0 - 79
BRCH. CIR. SELEC. CUR. AMPS 13.0
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 18 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 2379 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/4 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 1075
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 1.50 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 16.84 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 5 LBS, 5 OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 3/4
LINE SIZE - IN. O.D. LIQ. 6 5/16
FCCV — RESTRICTOR ORIFICE SIZE 0.069
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 33-1/4 X 30 X 26-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 187
NET (LBS.) 178
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA036C4 TXA037C4 TXC031E5 TXC036C4 TXC036D4 TXC036E5 TXC037C4


EXPANSION TYPE CHG TO 69 CHG TO 69 TXV-B CHG TO 69 CHG TO 69 TXV-B CHG TO 69
RATINGS (COOLING) 1
BTUH (TOTAL) 31200 31200 31200 31200 31200 32400 31200
BTUH (SENSIBLE) 22300 22300 21300 22300 22300 23300 22300
INDOOR AIRFLOW (CFM) 1125 1125 1000 1125 1125 1125 1125
SYSTEM POWER (KW) 3.39 3.39 3.34 3.39 3.39 3.45 3.39
SEER (BTU/WATT-HR.) 10.00 10.00 10.25 10.00 10.00 10.30 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 30000 30000 29600 30000 30000 30400 30000
SYSTEM POWER (KW) 2.73 2.73 2.73 2.73 2.73 2.68 2.73
COP 3.22 3.22 3.18 3.22 3.22 3.32 3.22
HSPF (BTU/WATT-HR.) 7.10 7.10 7.00 7.10 7.10 7.20 7.10

TXC037E5 TXH033A4
EXPANSION TYPE TXV-B CHG TO 69
RATINGS (COOLING) 1
BTUH (TOTAL) 32400 30200
BTUH (SENSIBLE) 23300 20600
INDOOR AIRFLOW (CFM) 1125 1000
SYSTEM POWER (KW) 3.45 3.32
SEER (BTU/WATT-HR.) 10.30 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 30400 29400
SYSTEM POWER (KW) 2.68 2.85
COP 3.32 3.02
HSPF (BTU/WATT-HR.) 7.20 6.90

See pages 23, 24, and 25 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 11


General TWR030C100A
Data

OUTDOOR UNIT WITH AIR HANDLERS

TVF025A14 TVF030A14 TVF036A14 TWE030C14 TWE036C14 TWE042C14 TWG025A14


EXPANSION TYPE CHG TO 69 CHG TO 69 CHG TO 69 CHG TO 69 CHG TO 69 CHG TO 69 CHG TO 69
RATINGS (COOLING) 1
BTUH (TOTAL) 29600 29600 31600 29000 30800 31000 28200
BTUH (SENSIBLE) 20100 20900 23300 19400 21500 22200 18400
INDOOR AIRFLOW (CFM) 900 1000 1125 950 1125 1125 875
SYSTEM POWER (KW) 3.29 3.22 3.47 3.22 3.38 3.41 3.10
SEER (BTU/WATT-HR.) 10.05 10.00 10.10 10.05 10.10 10.10 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 29000 30200 30400 28800 29800 30000 28200
SYSTEM POWER (KW) 2.81 2.75 2.77 2.81 2.82 2.76 2.89
COP 3.02 3.22 3.22 3.00 3.10 3.18 2.86
HSPF (BTU/WATT-HR.) 6.80 7.10 7.00 6.80 6.80 7.00 6.80

TWG030A14 TWG036A14 TWG037A14


EXPANSION TYPE FACT INS 69 CHG TO 69 CHG TO 69
RATINGS (COOLING) 1
BTUH (TOTAL) 28800 30400 30400
BTUH (SENSIBLE) 19200 21200 21100
INDOOR AIRFLOW (CFM) 1000 1125 1120
SYSTEM POWER (KW) 3.20 3.36 3.36
SEER (BTU/WATT-HR.) 10.00 10.00 10.10
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 28800 29600 29400
SYSTEM POWER (KW) 2.95 2.91 2.89
COP 2.86 2.98 2.98
HSPF (BTU/WATT-HR.) 6.80 6.80 6.80
OUTDOOR UNIT WITH FURNACES & COILS
TDD080R9V3 TDD080R9V3 TDD100R9V5 TDD100R9V5 TUD080R9V3 TUD080R9V3 TUD100R9V5
+TXC031E5 +TXC036E5 +TXC037E5 +TXC054E5 +TXC031E5 +TXC036E5 +TXC037E5
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 31400 32200 32400 32400 31600 32400 32600
BTUH (SENSIBLE) 21300 22100 22500 22700 21700 22500 22700
INDOOR AIRFLOW (CFM) 950 950 975 975 975 1000 1000
SYSTEM POWER (KW) 3.16 3.17 3.16 3.16 3.19 3.22 3.20
SEER (BTU/WATT-HR.) 11.20 11.50 11.60 11.50 11.20 11.35 11.55
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 28800 29200 29200 29400 29000 29400 29200
SYSTEM POWER (KW) 2.67 2.61 2.59 2.58 2.69 2.63 2.59
COP 3.16 3.28 3.30 3.34 3.16 3.28 3.30
HSPF (BTU/WATT-HR.) 7.15 7.35 7.40 7.50 7.20 7.35 7.40

TUD100R9V5 TUY080R9V3 TUY080R9V3 TUY100R9V4


+TXC054E5 +TXC031E5 +TXC036E5 +TXC037E5
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 32400 31600 32400 32600
BTUH (SENSIBLE) 22800 21800 22500 22700
INDOOR AIRFLOW (CFM) 1000 1000 1000 1000
SYSTEM POWER (KW) 3.21 3.22 3.26 3.20
SEER (BTU/WATT-HR.) 11.50 10.75 10.80 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 29400 29200 29400 29200
SYSTEM POWER (KW) 2.58 2.73 2.64 2.59
COP 3.34 3.14 3.26 3.30
HSPF (BTU/WATT-HR.) 7.50 7.15 7.30 7.40

See pages 23, 24, and 25 for combinations with Auxiliary Devices.

12 Pub. No. 22-1624-05-0199 (EN)


General TWR036C100A
Data

OUTDOOR UNIT 12 TWR036C100A


NOISE RATING (DECIBELS) 2 80 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 200/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 25
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
40
40
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 16.0 - 92
BRCH. CIR. SELEC. CUR. AMPS 19.0
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 18 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 2368 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/4 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 1075
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 1.50 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 16.84 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 6-LBS., 9-OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 7/8
LINE SIZE - IN. O.D. LIQ. 6 3/8
FCCV — RESTRICTOR ORIFICE SIZE 0.071
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 33-1/4 X 30 X 26-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 214
NET (LBS.) 205
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA036C4 TXA037C4 TXA042C4 TXA043C4 TXA050C4 TXC031E5 TXC036C4


EXPANSION TYPE FACT INS 71 FACT INS 71 CHG TO 71 CHG TO 71 CHG TO 71 TXV-B FACT INS 71
RATINGS (COOLING) 1
BTUH (TOTAL) 35400 35400 35800 36200 36800 35600 35400
BTUH (SENSIBLE) 24400 24400 25200 26100 26800 23900 24400
INDOOR AIRFLOW (CFM) 1200 1200 1250 1335 1350 1100 1200
SYSTEM POWER (KW) 3.85 3.85 3.87 3.93 3.96 3.79 3.85
SEER (BTU/WATT-HR.) 10.15 10.15 10.15 10.15 10.20 10.35 10.15
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 33000 33000 33400 33600 33800 32800 33000
SYSTEM POWER (KW) 3.18 3.18 3.18 3.16 3.15 3.18 3.18
COP 3.04 3.04 3.08 3.12 3.14 3.02 3.04
HSPF (BTU/WATT-HR.) 7.05 7.05 7.10 7.10 7.20 7.00 7.05

TXC036D4 TXC036E5 TXC037C4 TXC037E5 TXC042C4 TXC043C4 TXC050C4


EXPANSION TYPE FACT INS 71 TXV-B FACT INS 71 TXV-B CHG TO 71 CHG TO 71 CHG TO 71
RATINGS (COOLING) 1
BTUH (TOTAL) 35400 36600 35400 36600 35800 36200 36800
BTUH (SENSIBLE) 24400 25500 24400 25500 25200 26100 26800
INDOOR AIRFLOW (CFM) 1200 1200 1200 1200 1250 1335 1350
SYSTEM POWER (KW) 3.85 3.87 3.85 3.87 3.87 3.93 3.96
SEER (BTU/WATT-HR.) 10.15 10.40 10.15 10.40 10.15 10.15 10.20
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 33000 33400 33000 33400 33400 33600 33800
SYSTEM POWER (KW) 3.18 3.12 3.18 3.12 3.18 3.16 3.15
COP 3.04 3.14 3.04 3.14 3.08 3.12 3.14
HSPF (BTU/WATT-HR.) 7.05 7.20 7.05 7.20 7.10 7.10 7.20

See pages 25 and 26 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 13


General TWR036C100A
Data

OUTDOOR UNIT WITH HEAT PUMP COILS OUTDOOR UNIT WITH AIR HANDLERS

TXC054E5 TXH033A4 TXH041A4 TVF030A14 TVF036A14 TWE030C14 TWE036C14


EXPANSION TYPE TXV-B CHG TO 71 CHG TO 71 CHG TO 71 FACT INS 71 CHG TO 71 FACT INS 71
RATINGS (COOLING) 1
BTUH (TOTAL) 36800 34200 36800 34800 36200 32600 35200
BTUH (SENSIBLE) 27000 23000 26400 24100 25700 21100 23800
INDOOR AIRFLOW (CFM) 1350 1125 1350 1125 1200 950 1200
SYSTEM POWER (KW) 3.94 3.76 3.96 3.85 3.96 3.60 3.85
SEER (BTU/WATT-HR.) 10.25 10.10 10.25 10.20 10.00 10.15 10.30
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 33800 32400 33600 32800 34000 31200 32600
SYSTEM POWER (KW) 3.12 3.21 3.16 3.25 3.21 3.29 3.27
COP 3.18 2.96 3.12 2.96 3.10 2.78 2.92
HSPF (BTU/WATT-HR.) 7.25 6.85 7.10 7.00 7.10 6.80 6.90
OUTDOOR UNIT WITH AIR HANDLERS

TWE042C14 TWG030A14 TWG036A14 TWG037A14 TWG042A14


EXPANSION TYPE CHG TO 71 CHG TO 71 FACT INS 71 FACT INS 71 CHG TO 71
RATINGS (COOLING) 1
BTUH (TOTAL) 35200 32400 34000 34400 34800
BTUH (SENSIBLE) 24200 21200 22600 23100 24400
INDOOR AIRFLOW (CFM) 1200 1100 1150 1200 1280
SYSTEM POWER (KW) 3.87 3.58 3.84 3.78 3.85
SEER (BTU/WATT-HR.) 10.25 10.00 10.00 10.00 10.25
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 33000 31000 32400 32200 33600
SYSTEM POWER (KW) 3.22 3.29 3.37 3.30 3.24
COP 3.00 2.76 2.82 2.86 3.04
HSPF (BTU/WATT-HR.) 7.00 6.80 6.80 6.80 7.60
OUTDOOR UNIT WITH FURNACES & COILS
TDD080R9V3 TDD080R9V3 TDD100R9V5 TDD100R9V5 TUD080R9V3 TUD080R9V3 TUD100R9V5
+TXC031E5 +TXC036E5 +TXC037E5 +TXC054E5 +TXC031E5 +TXC036E5 +TXC037E5
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 35800 36800 37200 36800 36000 36800 37200
BTUH (SENSIBLE) 24200 25300 26000 26000 24800 25700 26100
INDOOR AIRFLOW (CFM) 1100 1125 1175 1175 1200 1200 1200
SYSTEM POWER (KW) 3.67 3.72 3.67 3.63 3.78 3.81 3.70
SEER (BTU/WATT-HR.) 10.80 10.90 10.90 10.90 10.80 10.90 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 32200 32600 32600 32800 32800 33000 32800
SYSTEM POWER (KW) 3.08 3.00 2.95 2.95 3.14 3.08 2.99
COP 3.06 3.18 3.24 3.26 3.06 3.14 3.22
HSPF (BTU/WATT-HR.) 7.10 7.30 7.40 7.50 7.10 7.25 7.40

TUD100R9V5 TUY080R9V3 TUY080R9V3 TUY100R9V4 TUY100R9V4


+TXC054E5 +TXC031E5 +TXC036E5 +TXC037E5 +TXC054E5
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 36800 35800 36600 37000 36800
BTUH (SENSIBLE) 26100 24400 25200 25800 26000
INDOOR AIRFLOW (CFM) 1200 1150 1150 1175 1175
SYSTEM POWER (KW) 3.68 3.75 3.77 3.68 3.66
SEER (BTU/WATT-HR.) 10.90 10.80 10.90 10.90 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 32800 32600 33000 32600 32800
SYSTEM POWER (KW) 2.95 3.14 3.08 2.97 2.95
COP 3.26 3.04 3.14 3.22 3.26
HSPF (BTU/WATT-HR.) 7.50 7.05 7.25 7.40 7.50

See pages 25 and 26 for combinations with Auxiliary Devices.

14 Pub. No. 22-1624-05-0199 (EN)


General TWR042C100B
Data

OUTDOOR UNIT 12 TWR042C100B


NOISE RATING (DECIBELS) 2 80 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 200/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 28
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
45
40
COMPRESSOR CLIMATUFF®
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 200/230/1/60
R.L. AMPS - L.R. AMPS 19.0 - 105
BRCH. CIR. SELEC. CUR. AMPS 21.0
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 22 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 3297 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/4 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 825
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 1.90 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 80 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 23.11 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 8 LBS., 2 OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 7/8
LINE SIZE - IN. O.D. LIQ. 6 3/8
FCCV — RESTRICTOR ORIFICE SIZE 0.080
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 37-1/2 X 34-3/4 X 30-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 252
NET (LBS.) 238
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA042C4 TXA043C4 TXA048C4 TXA049C4 TXA050C4 TXC036E5 TXC037E5


EXPANSION TYPE FACT INS 80 FACT INS 80 CHG TO 80 CHG TO 80 CHG TO 80 TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 42500 43000 43500 44500 44500 44000 44500
BTUH (SENSIBLE) 28000 29000 29300 31300 31300 29200 29800
INDOOR AIRFLOW (CFM) 1250 1400 1350 1575 1575 1275 1350
SYSTEM POWER (KW) 4.62 4.67 4.70 4.84 4.84 4.71 4.76
SEER (BTU/WATT-HR.) 10.10 10.10 10.15 10.10 10.10 10.35 10.35
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 41000 41500 41500 42500 42500 41500 41500
SYSTEM POWER (KW) 4.01 4.00 3.92 3.97 3.97 3.95 3.92
COP 3.00 3.04 3.10 3.14 3.14 3.08 3.10
HSPF (BTU/WATT-HR.) 7.40 7.50 7.55 7.60 7.60 7.50 7.55

TXC042C4 TXC043C4 TXC048C4 TXC049C4 TXC050C4 TXC054E5 TXH041A4


EXPANSION TYPE FACT INS 80 FACT INS 80 CHG TO 80 CHG TO 80 CHG TO 80 TXV-B CHG TO 80
RATINGS (COOLING) 1
BTUH (TOTAL) 42500 43000 43500 44500 44500 45000 44000
BTUH (SENSIBLE) 28000 29000 29300 31300 31300 31900 29500
INDOOR AIRFLOW (CFM) 1250 1400 1350 1575 1575 1575 1400
SYSTEM POWER (KW) 4.62 4.67 4.70 4.84 4.84 4.86 4.73
SEER (BTU/WATT-HR.) 10.10 10.10 10.15 10.10 10.10 10.25 10.20
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 41000 41500 41500 42500 42500 42500 41500
SYSTEM POWER (KW) 4.01 4.00 3.92 3.97 3.97 3.94 4.00
COP 3.00 3.04 3.10 3.14 3.14 3.16 3.04
HSPF (BTU/WATT-HR.) 7.40 7.50 7.55 7.60 7.60 7.65 7.50

See pages 26 and 27 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 15


General TWR042C100B
Data

OUTDOOR UNIT WITH HEAT PUMP COILS

TXH054A4
EXPANSION TYPE CHG TO 80
RATINGS (COOLING) 1
BTUH (TOTAL) 47000
BTUH (SENSIBLE) 33800
INDOOR AIRFLOW (CFM) 1575
SYSTEM POWER (KW) 4.97
SEER (BTU/WATT-HR.) 10.40
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 42500
SYSTEM POWER (KW) 3.92
COP 3.18
HSPF (BTU/WATT-HR.) 7.70
OUTDOOR UNIT WITH AIR HANDLERS

TVF036A14 TWE042C14-B TWE048C14-B TWE060A TWG042A14 TWG048A14


EXPANSION TYPE CHG TO 80 FACT INS 80 CHG TO 80 TXV-B FACT INS 80 CHG TO 80
RATINGS (COOLING) 1
BTUH (TOTAL) 43000 42500 44000 44500 41500 45000
BTUH (SENSIBLE) 29300 28200 30600 31200 27600 31100
INDOOR AIRFLOW (CFM) 1350 1400 1575 1575 1400 1575
SYSTEM POWER (KW) 4.83 4.59 4.84 4.78 4.66 4.86
SEER (BTU/WATT-HR.) 10.00 10.15 10.20 10.20 10.00 10.20
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 42000 42000 42500 42000 41000 42000
SYSTEM POWER (KW) 4.16 4.10 4.07 3.97 4.17 4.02
COP 2.96 3.00 3.06 3.10 2.88 3.06
HSPF (BTU/WATT-HR.) 7.40 7.50 7.55 7.55 7.30 7.55
OUTDOOR UNIT WITH FURNACES & COILS
TDD080R9V3 TDD100R9V5 TDD100R9V5 TUD080R9V3 TUD100R9V5 TUD100R9V5 TUD100R9V5
+TXC036E5 +TXC037E5 +TXC054E5 +TXC036E5 +TXC037E5 +TXC054E5 +TXC065S3
EXPANSION TYPE TXV-B TXV-B TXV-B TXV-B TXV-B TXV-B TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 44500 45000 44500 44500 44500 44500 46000
BTUH (SENSIBLE) 29800 30500 30500 30000 30100 30600 31900
INDOOR AIRFLOW (CFM) 1325 1400 1400 1400 1400 1400 1450
SYSTEM POWER (KW) 4.66 4.64 4.61 4.76 4.68 4.68 4.67
SEER (BTU/WATT-HR.) 10.85 10.85 10.90 10.60 10.85 10.85 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 41500 41500 41500 41500 41500 41500 42000
SYSTEM POWER (KW) 3.95 3.87 3.82 3.95 3.92 3.87 3.78
COP 3.08 3.14 3.18 3.08 3.10 3.14 3.26
HSPF (BTU/WATT-HR.) 7.65 7.75 7.85 7.60 7.65 7.75 7.95

TUD140R9V5 TUY100R9V4 TUY100R9V4 TUY120R9V5


+TXC065S3 +TXC037E5 +TXC054E5 +TXC065S3
EXPANSION TYPE TXV-NB TXV-B TXV-B TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 46000 45000 44500 46000
BTUH (SENSIBLE) 31500 30400 30400 31700
INDOOR AIRFLOW (CFM) 1375 1375 1375 1400
SYSTEM POWER (KW) 4.60 4.64 4.61 4.67
SEER (BTU/WATT-HR.) 10.90 10.80 10.90 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 41500 41000 41500 41500
SYSTEM POWER (KW) 3.73 3.83 3.85 3.75
COP 3.26 3.14 3.16 3.24
HSPF (BTU/WATT-HR.) 8.00 7.75 7.80 7.95

See pages 26 and 27 for combinations with Auxiliary Devices.

16 Pub. No. 22-1624-05-0199 (EN)


General TWR048D100A
Data

OUTDOOR UNIT 12 TWR048D100A


NOISE RATING (DECIBELS) 2 78 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 208/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 30/29
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
50
40
COMPRESSOR CLIMATUFF® - SCROLL
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 208/230/1/60
R.L. AMPS - L.R. AMPS 22.7 - 131
BRCH. CIR. SELEC. CUR. AMPS 22.7
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 22 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 3286 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/4 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 825
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 1.9 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 60 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 19.96 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 7-LBS., 10-OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 1 1/8
LINE SIZE - IN. O.D. LIQ. 6 3/8
FCCV — RESTRICTOR ORIFICE SIZE 0.083
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 33-1/4 X 34-3/4 X 30-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 240
NET (LBS.) 228
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA042C4 TXA043C4 TXA048C4 TXA049C4 TXA050C4 TXA060C5 TXA061C5


EXPANSION TYPE CHG TO 83 CHG TO 83 FACT INS 83 FACT INS 83 FACT INS 83 TXV-B TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 43500 45000 45000 46000 46000 47000 48000
BTUH (SENSIBLE) 28400 31000 30100 32100 32100 33700 34900
INDOOR AIRFLOW (CFM) 1250 1575 1350 1600 1600 1700 1760
SYSTEM POWER (KW) 4.78 4.97 4.92 5.05 5.05 5.14 5.22
SEER (BTU/WATT-HR.) 10.10 10.05 10.15 10.10 10.10 10.15 10.20
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 44000 44000 44000 44500 44500 44500 44500
SYSTEM POWER (KW) 4.30 4.11 4.11 4.08 4.08 4.00 4.00
COP 3.00 3.14 3.14 3.20 3.20 3.26 3.26
HSPF (BTU/WATT-HR.) 7.60 7.80 7.80 7.90 7.90 8.00 8.00

TXC042C4 TXC043C4 TXC048C4 TXC049C4 TXC050C4 TXC054E5 TXC054S3


EXPANSION TYPE CHG TO 83 CHG TO 83 FACT INS 83 FACT INS 83 FACT INS 83 TXV-B TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 43500 45000 45000 46000 46000 47000 47000
BTUH (SENSIBLE) 28400 31000 30100 32100 32100 33700 33700
INDOOR AIRFLOW (CFM) 1250 1575 1350 1600 1600 1700 1700
SYSTEM POWER (KW) 4.78 4.97 4.92 5.05 5.05 5.14 5.14
SEER (BTU/WATT-HR.) 10.10 10.05 10.15 10.10 10.10 10.15 10.55
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 44000 44000 44000 44500 44500 44500 44500
SYSTEM POWER (KW) 4.30 4.11 4.11 4.08 4.08 4.00 4.00
COP 3.00 3.14 3.14 3.20 3.20 3.26 3.26
HSPF (BTU/WATT-HR.) 7.60 7.80 7.80 7.90 7.90 8.00 8.00

See page 27 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 17


General TWR048D100A
Data

OUTDOOR UNIT WITH HEAT PUMP COILS

TXC060C5 TXC061C5 TXC065S3 TXH041A4 TXH054A4 TXH063P3


EXPANSION TYPE TXV-B TXV-B TXV-NB CHG TO 83 FACT INS 83 TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 47000 48000 48000 46000 48000 49000
BTUH (SENSIBLE) 33700 34900 35400 31500 34300 37200
INDOOR AIRFLOW (CFM) 1700 1760 1775 1575 1600 1800
SYSTEM POWER (KW) 5.14 5.22 5.19 5.03 5.11 5.21
SEER (BTU/WATT-HR.) 10.15 10.20 10.65 10.20 10.40 10.85
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 44500 44500 44500 44000 44500 44500
SYSTEM POWER (KW) 4.00 4.00 3.93 4.11 3.98 3.86
COP 3.26 3.26 3.32 3.14 3.28 3.38
HSPF (BTU/WATT-HR.) 8.00 8.00 8.05 7.80 8.05 8.20
OUTDOOR UNIT WITH AIR HANDLERS

TWE040E13 TWE042C14-B TWE042P13 TWE048C14-B TWE048P13 TWE060A-B TWE063P13


EXPANSION TYPE TXV-NB CHG TO 83 TXV-NB FACT INS 83 TXV-NB TXV-B TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 47500 45000 46000 47000 48500 47000 49000
BTUH (SENSIBLE) 33100 30400 31500 32400 35000 33600 37500
INDOOR AIRFLOW (CFM) 1425 1575 1575 1600 1600 1725 1800
SYSTEM POWER (KW) 4.87 5.11 5.11 5.11 5.19 5.03 5.44
SEER (BTU/WATT-HR.) 10.80 10.00 10.25 10.00 10.70 10.35 10.25
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 43500 44500 44500 45500 44500 44000 45500
SYSTEM POWER (KW) 3.84 4.38 4.21 4.19 3.93 4.00 4.04
COP 3.32 2.98 3.10 3.18 3.32 3.22 3.30
HSPF (BTU/WATT-HR.) 8.15 7.60 7.65 8.00 8.00 8.00 8.00

TWE065E13 TWG042A14 TWG048A14 TWG060A15


EXPANSION TYPE TXV-NB CHG TO 83 FACT INS 83 TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 49000 43000 46000 47500
BTUH (SENSIBLE) 34000 28600 31500 33900
INDOOR AIRFLOW (CFM) 1375 1475 1600 1740
SYSTEM POWER (KW) 4.85 4.91 5.11 5.28
SEER (BTU/WATT-HR.) 10.90 10.00 10.25 10.20
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 43500 44000 44500 45000
SYSTEM POWER (KW) 3.66 4.51 4.23 4.17
COP 3.48 2.86 3.08 3.16
HSPF (BTU/WATT-HR.) 8.35 7.50 7.50 7.90
OUTDOOR UNIT WITH FURNACES & COILS
TDD100R9V5 TDD100R9V5 TDD120R9V5 TDY100R9V4 TDY100R9V4 TUD100R9V5 TUD100R9V5
+TXC054S3 +TXH063P3 +TXH063P3 +TXC054E5 +TXC054S3 +TXC054S3 +TXC065S3
EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-B TXV-NB TXV-NB TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 47000 49000 49500 46000 46000 46500 47500
BTUH (SENSIBLE) 33200 35500 36200 32300 32300 33200 32300
INDOOR AIRFLOW (CFM) 1625 1600 1625 1625 1625 1675 1400
SYSTEM POWER (KW) 5.03 5.03 5.00 5.17 5.17 5.05 4.82
SEER (BTU/WATT-HR.) 10.70 10.90 10.90 10.10 10.10 10.50 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 44000 44000 44000 44500 44500 44500 43500
SYSTEM POWER (KW) 3.96 3.79 3.73 4.15 4.15 4.05 3.82
COP 3.26 3.40 3.46 3.14 3.14 3.22 3.34
HSPF (BTU/WATT-HR.) 8.20 8.50 8.55 7.90 7.90 8.05 8.35

See page 27 for combinations with Auxiliary Devices.

18 Pub. No. 22-1624-05-0199 (EN)


General TWR048D100A
Data

OUTDOOR UNIT WITH FURNACES & COILS


TUD100R9V5H TUD140R9V5 TUD140R9V5H TUY100R9V4 TUY120R9V5
+TXH063P3 +TXC065S3 +TXH063P3 +TXC054S3 +TXC065S3
EXPANSION TYPE TXV-NB TXV-NB TXV-NB TXV-NB TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 49000 46000 48000 46500 47500
BTUH (SENSIBLE) 35500 29900 34200 32600 33400
INDOOR AIRFLOW (CFM) 1600 1125 1550 1600 1600
SYSTEM POWER (KW) 5.13 4.65 5.19 5.03 5.08
SEER (BTU/WATT-HR.) 10.90 10.90 10.55 10.55 10.70
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 44000 43000 44500 44000 44500
SYSTEM POWER (KW) 3.84 3.89 3.98 4.00 3.98
COP 3.36 3.24 3.28 3.22 3.28
HSPF (BTU/WATT-HR.) 8.10 8.20 8.00 8.05 8.15

See page 27 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 19


General TWR060D100A
Data

OUTDOOR UNIT 12 TWR060D100A


NOISE RATING (DECIBELS) 2 78 1 CERTIFIED IN ACCORDANCE WITH A.R.I. STANDARD 210/240.
POWER CONNS. — V/PH/HZ 208/230/1/60 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270.
MIN. BRCH. CIR. AMPACITY 3 39
BR. CIR.
PROT. RTG. } MAX. (AMPS)
RECMD. (AMPS)
60
50
COMPRESSOR CLIMATUFF® - SCROLL
NO. USED - NO. SPEEDS 1-1
VOLTS/PH/HZ 208/230/1/60
R.L. AMPS - L.R. AMPS 30.1 - 175
BRCH. CIR. SELEC. CUR. AMPS 22.7
OUTDOOR FAN — TYPE PROPELLER SPLIT SYSTEM
DIA. (IN.) - NO. USED 26 - 1
TYPE DRIVE - NO. SPEEDS DIRECT - 1 3 CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE.
CFM @ 0.0 IN. W.G. 4 3770 SUITABLE FOR USE WITH HACR CIRCUIT BREAKERS OR FUSES.
NO. MOTORS - HP 1 - 1/4 4 STANDARD AIR - DRY COIL - OUTDOOR
MOTOR SPEED R.P.M. 825
VOLTS/PH/HZ 200/230/1/60 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE
F.L. AMPS 1.90 UNIT NAMEPLATE AND SERVICE INSTRUCTION.
OUTDOOR COIL — TYPE SPINE FIN™ 6 MAX. LINEAR LENGTH 60 FT; MAX. LIFT - SUCTION 60 FT; MAX.
ROWS - F.P.I. 1 - 24 LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO
FACE AREA (SQ. FT.) 28.46 REFRIGERANT PIPING MANUAL PUB. NO. 22-3238-02.
TUBE SIZE (IN.) 3/8
REFRIGERANT CONTROL EXPANSION VALVE
REFRIGERANT
LBS. — R-22 (O.D. UNIT) 5 9-LBS., 14-OZ.
FACTORY SUPPLIED YES
LINE SIZE - IN. O.D. GAS 6 1 1/8
LINE SIZE - IN. O.D. LIQ. 6 3/8
FCCV — RESTRICTOR ORIFICE SIZE 0.095
DIMENSIONS H X W X D
OUTDOOR UNIT - CRATED (IN.) 37-1/2 X 40-3/4 X 36-1/2
UNCRATED SEE OUTLINE DWG.
WEIGHT
SHIPPING (LBS.) 301
NET (LBS.) 286
OUTDOOR UNIT WITH HEAT PUMP COILS

TXA049C4 TXA050C4 TXA060C5 TXA061C5 TXC050C4 TXC054E5 TXC054S3


EXPANSION TYPE CHG TO 95 CHG TO 95 TXV-B TXV-B CHG TO 95 TXV-B TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 56500 56500 58000 59500 56500 57500 57500
BTUH (SENSIBLE) 37000 37000 38100 40600 37000 37900 37900
INDOOR AIRFLOW (CFM) 1675 1675 1700 2000 1675 1700 1700
SYSTEM POWER (KW) 6.01 6.01 6.11 6.26 6.01 6.08 6.08
SEER (BTU/WATT-HR.) 10.40 10.40 10.50 10.50 10.40 10.50 10.85
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 60500 60500 60500 61000 60500 60500 60500
SYSTEM POWER (KW) 5.76 5.76 5.65 5.52 5.76 5.65 5.65
COP 3.08 3.08 3.14 3.24 3.08 3.14 3.14
HSPF (BTU/WATT-HR.) 8.05 8.05 8.15 8.30 8.05 8.15 8.15
OUTDOOR UNIT WITH HEAT PUMP COILS

TXC060C5 TXC061C5 TXC065S3 TXH054A4 TXH063P3


EXPANSION TYPE TXV-B TXV-B TXV-NB CHG TO 95 TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 58000 59500 61000 60000 62500
BTUH (SENSIBLE) 38100 40600 41700 39900 44000
INDOOR AIRFLOW (CFM) 1700 2000 2000 1700 2000
SYSTEM POWER (KW) 6.11 6.26 6.32 6.12 6.35
SEER (BTU/WATT-HR.) 10.50 10.50 10.90 10.80 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 60500 61000 61000 60500 61000
SYSTEM POWER (KW) 5.65 5.52 5.38 5.54 5.26
COP 3.14 3.24 3.32 3.20 3.40
HSPF (BTU/WATT-HR.) 8.15 8.30 8.50 8.25 8.55

See page 27 for combinations with Auxiliary Devices.

20 Pub. No. 22-1624-05-0199 (EN)


General TWR060D100A
Data

OUTDOOR UNIT WITH AIR HANDLERS


TWE060C15-C
TWE048C14-B TWE048P13 TWE060A-B TWE060D15-A TWE060P13 TWE063P13 TWE065E13
EXPANSION TYPE CHG TO 95 TXV-NB TXV-B TXV-B TXV-NB TXV-NB TXV-NB
RATINGS (COOLING) 1
BTUH (TOTAL) 57500 58000 59000 57500 61500 61500 63000
BTUH (SENSIBLE) 37600 39500 39900 38800 41900 42100 43900
INDOOR AIRFLOW (CFM) 1800 1800 2000 2000 1800 1825 1875
SYSTEM POWER (KW) 6.22 5.92 6.11 6.53 6.28 6.47 6.24
SEER (BTU/WATT-HR.) 10.50 10.80 10.65 10.00 10.90 10.80 10.90
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 61000 61000 60500 62500 61000 61500 60500
SYSTEM POWER (KW) 5.96 5.42 5.65 5.72 5.42 5.46 5.12
COP 3.00 3.30 3.14 3.20 3.30 3.30 3.46
HSPF (BTU/WATT-HR.) 8.00 8.40 8.15 8.40 8.40 8.35 8.65

TWE090A-B TWG048A14 TWG060A15


EXPANSION TYPE TXV-NB CHG TO 95 TXV-B
RATINGS (COOLING) 1
BTUH (TOTAL) 63000 56500 57500
BTUH (SENSIBLE) 45400 36300 38600
INDOOR AIRFLOW (CFM) 2250 1625 2000
SYSTEM POWER (KW) 6.15 6.04 6.18
SEER (BTU/WATT-HR.) 10.90 10.60 10.00
RATINGS (HEATING) 1
(HIGH TEMP.) BTUH 60500 60500 61500
SYSTEM POWER (KW) 5.07 6.16 5.74
COP 3.50 2.88 3.14
HSPF (BTU/WATT-HR.) 8.80 7.80 8.25

See page 27 for combinations with Auxiliary Devices.

Pub. No. 22-1624-05-0199 (EN) 21


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR012C100A Y TVF018A14 - N 550 10.00 15600 14700 7.00 3.20
TWR012C100A Y TVF025A14 - N 550 10.00 15800 14500 7.00 3.08
TWR012C100A Y TXA024C4 Y N 550 10.20 15200 14200 6.80 2.94
TWR012C100A N TXA025C4 Y N 550 10.30 15500 14400 6.80 3.08
TWR012C100A Y TXA025C4 Y N 550 10.30 15500 14400 7.00 3.08
TWR012C100A Y TXC024C4 Y N 550 10.20 15200 14200 6.80 2.94
TWR012C100A Y TXC024D4 Y N 550 10.20 15200 14200 6.80 2.94
TWR012C100A N TXC025C4 Y N 550 10.30 15500 14400 6.80 3.08
TWR012C100A Y TXC025C4 Y N 550 10.30 15500 14400 7.00 3.08
TWR012C100A N TXC025D4 Y N 550 10.30 15500 14400 6.80 3.08
TWR012C100A Y TXC025D4 Y N 550 10.30 15500 14400 7.00 3.08
TWR012C100A Y TXH025A4 Y N 555 10.15 14900 14600 6.80 2.94
TWR018C100A Y TUD080R9V3 - N 600 10.90 17900 16100 7.50 3.56
+TXC031E5
TWR018C100A Y TVF018A14 - N 600 10.00 17300 16600 7.20 3.36
TWR018C100A Y TVF025A14 - N 640 10.10 17400 16500 7.00 3.28
TWR018C100A * N TWE018P13 N N 600 10.10 17200 16300 6.85 3.24
TWR018C100A * N TWE024P13 N N 640 10.20 17400 16500 6.90 3.28
TWR018C100A * N TWE030P13 N N 625 10.15 17300 16500 6.80 3.22
TWR018C100A * N TWE030P13 N N 625 10.15 17300 16500 7.00 3.22
TWR018C100A * N TWE031E13 N N 650 10.90 17800 16000 7.25 3.40
TWR018C100A Y TXA018C4 Y N 600 10.05 16300 15800 6.80 2.98
TWR018C100A N TXA024C4 Y N 615 10.15 16700 16100 6.80 3.10
TWR018C100A Y TXA024C4 Y N 615 10.15 16700 16100 7.00 3.10
TWR018C100A N TXA025C4 Y N 625 10.25 17000 16400 6.85 3.22
TWR018C100A Y TXA025C4 Y N 625 10.25 17000 16400 7.00 3.22
TWR018C100A Y TXC018C4 Y N 600 10.05 16300 15800 6.80 2.98
TWR018C100A N TXC024C4 Y N 615 10.15 16700 16100 6.80 3.10
TWR018C100A Y TXC024C4 Y N 615 10.15 16700 16100 7.00 3.10
TWR018C100A N TXC024D4 Y N 615 10.15 16700 16100 6.80 3.10
TWR018C100A Y TXC024D4 Y N 615 10.15 16700 16100 7.00 3.10
TWR018C100A N TXC025C4 Y N 625 10.25 17000 16400 6.85 3.22
TWR018C100A Y TXC025C4 Y N 625 10.25 17000 16400 7.00 3.22
TWR018C100A N TXC025D4 Y N 625 10.25 17000 16400 6.85 3.22
TWR018C100A Y TXC025D4 Y N 625 10.25 17000 16400 7.00 3.22
TWR018C100A N TXH025A4 Y N 615 10.15 16800 16100 6.80 3.12
TWR024C100A * N TDD080R9V3 - N 775 10.90 24800 21800 7.25 3.36
+TXC031S3
TWR024C100A * N TUD080R9V3 - N 800 10.80 24800 22000 7.20 3.34
+TXC031S3
TWR024C100A Y TUD080R9V3 - N 825 11.80 25600 22200 7.50 3.48
+TXC036E5
TWR024C100A Y TVF018A14 - N 675 10.30 23400 22000 7.00 3.04
TWR024C100A Y TVF024A14 - N 800 10.25 24000 22200 7.20 3.10
TWR024C100A N TVF024A14 - Y 800 10.50 22200 22200 6.80 3.10
TWR024C100A * N TVF024A14 - Y 800 10.50 22200 22200 6.80 3.10
TWR024C100A Y TVF025A14 - N 800 10.40 23600 22600 7.20 3.20
TWR024C100A N TVF025A14 - Y 800 10.55 22600 22600 6.95 3.20
TWR024C100A * N TVF025A14 - Y 800 10.55 22600 22600 6.95 3.20

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

22 Pub. No. 22-1624-05-0199 (EN)


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR024C100A Y TVF030A14 - N 900 10.45 24800 22600 7.20 3.22
TWR024C100A Y TVF036A14 - N 900 10.15 25000 23000 7.00 3.20
TWR024C100A * N TWE018P13 N N 675 10.35 23400 21800 6.80 3.06
TWR024C100A * N TWE024P13 N N 800 10.50 24000 22200 6.80 3.14
TWR024C100A Y TWE030C14 - N 875 10.15 23800 22200 7.00 3.08
TWR024C100A * N TWE030P13 N N 895 10.75 24400 22400 6.85 3.14
TWR024C100A * N TWE030P13 N N 895 10.75 24400 22400 7.00 3.14
TWR024C100A * N TWE031E13 N N 825 10.90 24600 21800 7.15 3.30
TWR024C100A Y TWE036C14 - N 900 10.20 24400 22600 7.00 3.12
TWR024C100A * N TWE036P13 N N 900 10.60 24600 22800 6.85 3.16
TWR024C100A * N TWE036P13 N N 900 10.60 24600 22800 7.00 3.16
TWR024C100A * N TWE062E13 N N 1650 10.90 48000 44500 7.75 3.24
TWR024C100A Y TXA024C4 N N 800 10.05 23000 21600 6.80 2.94
TWR024C100A Y TXA024C4 Y N 800 10.40 23000 21600 6.80 2.94
TWR024C100A N TXA025C4 Y N 800 10.45 23400 22200 6.80 3.10
TWR024C100A Y TXA025C4 Y N 800 10.45 23400 22200 7.00 3.10
TWR024C100A N TXA030C4 Y N 890 10.45 24000 22400 6.80 3.08
TWR024C100A Y TXA030C4 Y N 890 10.45 24000 22400 7.00 3.08
TWR024C100A N TXA031C4 Y N 890 10.45 24200 22600 6.90 3.16
TWR024C100A Y TXA031C4 Y N 890 10.45 24200 22600 7.00 3.16
TWR024C100A N TXA035C4 Y N 890 10.50 24000 22400 6.80 3.08
TWR024C100A Y TXC024C4 N N 800 10.05 23000 21600 6.80 2.94
TWR024C100A Y TXC024C4 Y N 800 10.40 23000 21600 6.80 2.94
TWR024C100A Y TXC024D4 N N 800 10.05 23000 21600 6.80 2.94
TWR024C100A Y TXC024D4 Y N 800 10.40 23000 21600 6.80 2.94
TWR024C100A N TXC025C4 Y N 800 10.45 23400 22200 6.80 3.10
TWR024C100A Y TXC025C4 Y N 800 10.45 23400 22200 7.00 3.10
TWR024C100A N TXC025D4 Y N 800 10.45 23400 22200 6.80 3.10
TWR024C100A Y TXC025D4 Y N 800 10.45 23400 22200 7.00 3.10
TWR024C100A N TXC030C4 Y N 890 10.45 24000 22400 6.80 3.08
TWR024C100A Y TXC030C4 Y N 890 10.45 24000 22400 7.00 3.08
TWR024C100A N TXC030D4 Y N 890 10.45 24000 22400 6.80 3.08
TWR024C100A Y TXC030D4 Y N 890 10.45 24000 22400 7.00 3.08
TWR024C100A N TXC031C4 Y N 890 10.45 24200 22600 6.90 3.16
TWR024C100A Y TXC031C4 Y N 890 10.45 24200 22600 7.00 3.16
TWR024C100A N TXC031D4 Y N 890 10.45 24200 22600 6.90 3.16
TWR024C100A Y TXC031D4 Y N 890 10.45 24200 22600 7.00 3.16
TWR024C100A N TXC031E5 Y N 900 10.90 24800 22800 7.00 3.22
TWR024C100A * N TXC031S3 N N 900 10.80 24800 22800 7.00 3.22
TWR024C100A N TXC035C4 Y N 890 10.50 24000 22400 6.80 3.08
TWR024C100A N TXC035D4 Y N 890 10.50 24000 22400 6.80 3.08
TWR024C100A N TXH025A4 Y N 800 10.50 23200 21800 6.80 2.94
TWR024C100A N TXH033A4 Y N 900 10.55 24400 22600 6.85 3.16
TWR030C100A * N TDD080R9V3 - N 950 10.90 31400 28800 7.20 3.16
+TXC031S3
TWR030C100A Y TDD080R9V3 - N 950 11.50 32200 29200 7.50 3.28
+TXC036E5
TWR030C100A * N TDD080R9V3 - N 950 10.90 32200 29200 7.40 3.28
+TXC036S3

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

Pub. No. 22-1624-05-0199 (EN) 23


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR030C100A * N TDD100R9V5 - N 975 10.90 32400 29200 7.45 3.30
+TXC037S3
TWR030C100A * N TUD080R9V3 - N 975 10.90 31600 29000 7.20 3.16
+TXC031S3
TWR030C100A Y TUD080R9V3 - N 1000 11.35 32400 29400 7.50 3.28
+TXC036E5
TWR030C100A * N TUD080R9V3 - N 1000 10.90 32400 29400 7.40 3.28
+TXC036S3
TWR030C100A * N TUD100R9V5 - N 1000 10.90 32600 29200 7.45 3.30
+TXC037S3
TWR030C100A Y TVF025A14 - N 900 10.05 29600 29000 7.00 3.02
TWR030C100A Y TVF030A14 - N 1000 10.00 29600 30200 7.20 3.24
TWR030C100A Y TVF036A14 - N 1125 10.10 31600 30400 7.20 3.22
TWR030C100A * N TWE024P13 N N 900 10.15 30000 29000 6.80 2.92
TWR030C100A Y TWE030C14 - N 950 10.05 29000 28800 7.00 3.00
TWR030C100A * N TWE030P13 N N 950 10.50 30400 29000 6.85 2.98
TWR030C100A * N TWE030P13 N N 950 10.50 30400 29000 7.00 2.98
TWR030C100A * N TWE031E13 N N 1025 10.90 31200 28800 7.10 3.16
TWR030C100A Y TWE036C14 - N 1125 10.10 30800 29800 7.00 3.10
TWR030C100A * N TWE036P13 N N 1125 10.25 31400 30000 7.00 3.06
TWR030C100A Y TWE042C14 - N 1125 10.10 31000 30000 7.20 3.18
TWR030C100A * N TWE042P13 N N 1125 10.35 32000 30400 7.10 3.14
TWR030C100A * N TWE062E13 N N 2050 10.60 60000 59500 7.80 3.04
TWR030C100A N TXA030C4 Y N 1000 10.25 29800 29000 6.80 2.98
TWR030C100A Y TXA030C4 Y N 1000 10.25 29800 29000 7.00 2.98
TWR030C100A N TXA031C4 Y N 1000 10.30 30000 29400 6.90 3.12
TWR030C100A Y TXA031C4 Y N 1000 10.30 30000 29400 7.00 3.12
TWR030C100A N TXA035C4 Y N 1100 10.20 30200 29400 6.80 2.94
TWR030C100A N TXA036C4 Y N 1125 10.35 31200 30000 7.10 3.22
TWR030C100A Y TXA036C4 Y N 1125 10.35 31200 30000 7.20 3.22
TWR030C100A N TXA037C4 Y N 1125 10.35 31200 30000 7.10 3.22
TWR030C100A Y TXA037C4 Y N 1125 10.35 31200 30000 7.20 3.22
TWR030C100A N TXC030C4 Y N 1000 10.25 29800 29000 6.80 2.98
TWR030C100A Y TXC030C4 Y N 1000 10.25 29800 29000 7.00 2.98
TWR030C100A N TXC030D4 Y N 1000 10.25 29800 29000 6.80 2.98
TWR030C100A Y TXC030D4 Y N 1000 10.25 29800 29000 7.00 2.98
TWR030C100A N TXC031C4 Y N 1000 10.30 30000 29400 6.90 3.12
TWR030C100A Y TXC031C4 Y N 1000 10.30 30000 29400 7.00 3.12
TWR030C100A N TXC031D4 Y N 1000 10.30 30000 29400 6.90 3.12
TWR030C100A Y TXC031D4 Y N 1000 10.30 30000 29400 7.00 3.12
TWR030C100A N TXC031E5 Y N 1000 10.65 31200 29600 7.00 3.18
TWR030C100A Y TXC031E5 Y N 1000 10.65 31200 29600 7.20 3.18
TWR030C100A * N TXC031S3 N N 1000 10.60 31200 29600 7.05 3.10
TWR030C100A N TXC035C4 Y N 1100 10.20 30200 29400 6.80 2.94
TWR030C100A N TXC035D4 Y N 1100 10.20 30200 29400 6.80 2.94
TWR030C100A N TXC036C4 Y N 1125 10.35 31200 30000 7.10 3.22
TWR030C100A Y TXC036C4 Y N 1125 10.35 31200 30000 7.20 3.22
TWR030C100A N TXC036D4 Y N 1125 10.35 31200 30000 7.10 3.22
TWR030C100A Y TXC036D4 Y N 1125 10.35 31200 30000 7.20 3.22

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

24 Pub. No. 22-1624-05-0199 (EN)


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR030C100A N TXC036E5 Y N 1125 10.75 32400 30400 7.20 3.32
TWR030C100A * N TXC036S3 N N 1125 10.70 32400 30400 7.25 3.20
TWR030C100A N TXC037C4 Y N 1125 10.35 31200 30000 7.10 3.22
TWR030C100A Y TXC037C4 Y N 1125 10.35 31200 30000 7.20 3.22
TWR030C100A N TXC037E5 Y N 1125 10.75 32400 30400 7.20 3.32
TWR030C100A * N TXC037S3 N N 1125 10.70 32400 30400 7.25 3.20
TWR030C100A N TXH025A4 Y N 900 10.05 28600 28200 6.80 2.76
TWR030C100A N TXH033A4 Y N 1000 10.35 30200 29400 6.90 3.02
TWR036C100A * N TDD080R9V3 - N 1125 10.90 36000 32400 7.15 3.06
+TXC031S3
TWR036C100A Y TDD080R9V3 - N 1125 10.90 36800 32600 7.50 3.18
+TXC036E5
TWR036C100A * N TDD080R9V3 - N 1125 10.90 36800 32600 7.35 3.18
+TXC036S3
TWR036C100A * N TDD100R9V5 - N 1175 10.90 37200 32600 7.45 3.24
+TXC037S3
TWR036C100A * N TDD100R9V5 - N 1175 10.90 37000 32600 7.55 3.28
+TXC054S3
TWR036C100A * N TUD080R9V3 - N 1200 10.75 36000 32800 7.10 3.06
+TXC031S3
TWR036C100A Y TUD080R9V3 - N 1200 10.90 36800 33000 7.50 3.14
+TXC036E5
TWR036C100A * N TUD080R9V3 - N 1200 10.90 36800 33000 7.25 3.14
+TXC036S3
TWR036C100A * N TUD080R9V3 - N 1175 10.90 36600 33000 7.40 3.22
+TXC054S3
TWR036C100A * N TUD100R9V5 - N 1200 10.90 37200 32800 7.40 3.22
+TXC037S3
TWR036C100A * N TUD100R9V5 - N 1200 10.90 36800 32800 7.45 3.26
+TXC054S3
TWR036C100A Y TVF030A14 - N 1125 10.20 34800 32800 7.20 2.96
TWR036C100A Y TVF036A14 - N 1200 10.25 36200 34000 7.20 3.10
TWR036C100A Y TWE030C14 - N 950 10.15 32600 31200 7.00 2.78
TWR036C100A * N TWE030P13 N N 950 10.50 33600 31600 6.80 2.86
TWR036C100A Y TWE036C14 - N 1200 10.30 35200 32600 7.00 2.92
TWR036C100A * N TWE036P13 N N 1200 10.50 35600 33000 7.00 2.98
TWR036C100A * N TWE037E13 N N 1200 10.85 36200 32200 7.15 3.12
TWR036C100A * N TWE040E13 N N 1275 10.90 38500 33000 7.67 3.38
TWR036C100A Y TWE042C14 - N 1200 10.25 35200 33000 7.20 3.00
TWR036C100A * N TWE042P13 N N 1350 10.50 36800 33600 7.15 3.10
TWR036C100A * N TWE048P13 N N 1350 10.80 37400 33800 7.30 3.18
TWR036C100A N TXA036C4 Y N 1200 10.55 35400 33000 7.10 3.04
TWR036C100A Y TXA036C4 Y N 1200 10.55 35400 33000 7.20 3.04
TWR036C100A N TXA037C4 Y N 1200 10.55 35400 33000 7.10 3.04
TWR036C100A Y TXA037C4 Y N 1200 10.55 35400 33000 7.20 3.04
TWR036C100A N TXA042C4 Y N 1250 10.55 35800 33400 7.20 3.08
TWR036C100A N TXA043C4 Y N 1335 10.50 36200 33600 7.20 3.12
TWR036C100A N TXA050C4 Y N 1350 10.60 36800 33800 7.25 3.14
TWR036C100A N TXC031E5 Y N 1100 10.75 35600 32800 7.05 3.02
TWR036C100A Y TXC031E5 Y N 1100 10.75 35600 32800 7.20 3.02
TWR036C100A * N TXC031S3 N N 1100 10.65 35600 32800 7.05 3.02

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

Pub. No. 22-1624-05-0199 (EN) 25


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR036C100A N TXC036C4 Y N 1200 10.55 35400 33000 7.10 3.04
TWR036C100A Y TXC036C4 Y N 1200 10.55 35400 33000 7.20 3.04
TWR036C100A N TXC036D4 Y N 1200 10.55 35400 33000 7.10 3.04
TWR036C100A Y TXC036D4 Y N 1200 10.55 35400 33000 7.20 3.04
TWR036C100A N TXC036E5 Y N 1200 10.85 36600 33400 7.25 3.14
TWR036C100A * N TXC036S3 N N 1200 10.80 36600 33400 7.25 3.14
TWR036C100A N TXC037C4 Y N 1200 10.55 35400 33000 7.10 3.04
TWR036C100A Y TXC037C4 Y N 1200 10.55 35400 33000 7.20 3.04
TWR036C100A N TXC037E5 Y N 1200 10.85 36600 33400 7.25 3.14
TWR036C100A * N TXC037S3 N N 1200 10.80 36600 33400 7.25 3.14
TWR036C100A N TXC042C4 Y N 1250 10.55 35800 33400 7.20 3.08
TWR036C100A N TXC043C4 Y N 1335 10.50 36200 33600 7.20 3.12
TWR036C100A N TXC050C4 Y N 1350 10.60 36800 33800 7.25 3.14
TWR036C100A N TXC054E5 Y N 1350 10.70 36800 33800 7.35 3.18
TWR036C100A * N TXC054S3 N N 1350 10.70 36800 33800 7.35 3.18
TWR036C100A N TXH033A4 Y N 1125 10.50 34200 32400 7.00 2.96
TWR036C100A N TXH041A4 Y N 1350 10.65 36800 33600 7.20 3.12
TWR042C100B * N TDD080R9V3 - N 1325 10.85 44500 41500 7.65 3.08
+TXC036S3
TWR042C100B * N TDD100R9V5 - N 1400 10.85 45000 41500 7.75 3.14
+TXC037S3
TWR042C100B Y TDD100R9V5 - N 1400 10.90 44500 41500 8.00 3.18
+TXC054E5
TWR042C100B * N TDD100R9V5 - N 1400 10.90 44500 41500 7.85 3.18
+TXC054S3
TWR042C100B * N TUD080R9V3 - N 1400 10.60 44500 41500 7.60 3.08
+TXC036S3
TWR042C100B * N TUD100R9V5 - N 1400 10.85 44500 41500 7.65 3.10
+TXC037S3
TWR042C100B Y TUD100R9V5 - N 1400 10.85 44500 41500 8.00 3.14
+TXC054E5
TWR042C100B * N TUD100R9V5 - N 1400 10.85 44500 41500 7.75 3.14
+TXC054S3
TWR042C100B * N TUY100R9V4 - N 1375 10.80 45000 41000 7.75 3.14
+TXC037S3
TWR042C100B * N TUY100R9V4 - N 1375 10.90 44500 41500 7.80 3.16
+TXC054S3
TWR042C100B Y TVF036A14 - N 1350 10.00 43000 42000 7.50 2.96
TWR042C100B * N TWE036P13 N N 1350 10.15 42500 41000 7.20 2.90
TWR042C100B * N TWE037E13 N N 1400 10.70 43500 41000 7.40 3.02
TWR042C100B * N TWE040E13 N N 1225 10.80 45500 41000 7.85 3.22
TWR042C100B * N TWE040E13 N N 1225 10.80 45500 41000 8.00 3.22
TWR042C100B * N TWE042P13 N N 1400 10.50 44000 41500 7.40 3.04
TWR042C100B * N TWE042P13 N N 1400 10.50 44000 41500 7.50 3.04
TWR042C100B * N TWE048P13-B N N 1575 10.65 45500 42500 7.60 3.14
TWR042C100B * N TWE060P13 N N 1575 10.75 47000 43000 7.70 3.22
TWR042C100B * N TWE063P13 N N 1575 10.50 47000 43500 7.65 3.18
TWR042C100B * N TWE065E13 N N 1375 10.90 47500 42000 8.10 3.38
TWR042C100B * N TWE120B-B N N 3150 9.25# 88000 82000 7.65 3.10
TWR042C100B N TXA042C4 Y N 1250 10.50 42500 41000 7.50 3.00
TWR042C100B N TXA043C4 Y N 1400 10.50 43000 41500 7.55 3.04

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

26 Pub. No. 22-1624-05-0199 (EN)


Ratings with
Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT AND/OR INSULATION KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay kit and/or
TXV kit may increase the system SEER. The addition of a BAYINS001 kit on the outdoor unit may increase the system HSPF. See charts below for ratings.
FAN
OUTDOOR INS INDOOR DELAY TXV COOLING HI-TEMP HI-TEMP
MODEL KIT MODEL KIT KIT CFM SEER CAPACITY HEATING HSPF COP
TWR042C100B N TXA048C4 Y N 1350 10.55 43500 41500 7.65 3.10
TWR042C100B N TXA049C4 Y N 1575 10.50 44500 42500 7.70 3.14
TWR042C100B N TXA050C4 Y N 1575 10.50 44500 42500 7.70 3.14
TWR042C100B N TXC036E5 Y N 1275 10.75 44000 41500 7.65 3.08
TWR042C100B * N TXC036S3 N N 1275 10.70 44000 41500 7.50 3.08
TWR042C100B N TXC037E5 Y N 1350 10.75 44500 41500 7.65 3.10
TWR042C100B * N TXC037S3 N N 1350 10.70 44500 41500 7.55 3.10
TWR042C100B N TXC042C4 Y N 1250 10.50 42500 41000 7.50 3.00
TWR042C100B N TXC043C4 Y N 1400 10.50 43000 41500 7.55 3.04
TWR042C100B N TXC048C4 Y N 1350 10.55 43500 41500 7.65 3.10
TWR042C100B N TXC049C4 Y N 1575 10.50 44500 42500 7.70 3.14
TWR042C100B N TXC050C4 Y N 1575 10.50 44500 42500 7.70 3.14
TWR042C100B N TXC054E5 Y N 1575 10.65 45000 42500 7.80 3.16
TWR042C100B * N TXC054S3 N N 1575 10.60 45000 42500 7.65 3.16
TWR042C100B N TXH033A4 Y N 1125 10.15 39500 40000 7.25 2.84
TWR042C100B N TXH041A4 Y N 1400 10.60 44000 41500 7.55 3.04
TWR042C100B N TXH054A4 Y N 1575 10.80 47000 42500 7.85 3.18
TWR048D100A N TWE048C14-B - Y 1600 10.50 47000 45500 8.00 3.18
TWR048D100A N TXA042C4 Y N 1250 10.50 43500 44000 7.75 3.00
TWR048D100A N TXA043C4 Y N 1575 10.50 45000 44000 7.90 3.14
TWR048D100A N TXA048C4 Y N 1350 10.55 45000 44000 8.00 3.14
TWR048D100A N TXA049C4 Y N 1600 10.50 46000 44500 8.00 3.20
TWR048D100A N TXA050C4 Y N 1600 10.50 46000 44500 8.00 3.20
TWR048D100A N TXA060C5 Y N 1700 10.60 47000 44500 8.10 3.26
TWR048D100A N TXA061C5 Y N 1760 10.65 48000 44500 8.15 3.26
TWR048D100A N TXC042C4 Y N 1250 10.50 43500 44000 7.80 3.00
TWR048D100A N TXC043C4 Y N 1575 10.50 45000 44000 7.90 3.14
TWR048D100A N TXC048C4 Y N 1350 10.55 45000 44000 8.00 3.14
TWR048D100A N TXC049C4 Y N 1600 10.50 46000 44500 8.00 3.20
TWR048D100A N TXC050C4 Y N 1600 10.50 46000 44500 8.00 3.20
TWR048D100A N TXC054E5 Y N 1700 10.55 47000 44500 8.10 3.26
TWR048D100A N TXC060C5 Y N 1700 10.60 47000 44500 8.10 3.26
TWR048D100A N TXC061C5 Y N 1760 10.65 48000 44500 8.15 3.26
TWR048D100A N TXH041A4 Y N 1575 10.60 46000 44000 7.90 3.14
TWR048D100A N TXH054A4 Y N 1600 10.80 48000 44500 8.15 3.28
TWR060D100A N TXA049C4 Y N 1675 10.80 56500 60500 8.20 3.08
TWR060D100A N TXA050C4 Y N 1675 10.80 56500 60500 8.20 3.08
TWR060D100A N TXA060C5 Y N 1700 10.95 58000 60500 8.30 3.14
TWR060D100A N TXA061C5 Y N 2000 10.90 59500 61000 8.50 3.24
TWR060D100A N TXC050C4 Y N 1675 10.80 56500 60500 8.20 3.08
TWR060D100A N TXC054E5 Y N 1700 10.90 57500 60500 8.30 3.14
TWR060D100A N TXC060C5 Y N 1700 10.95 58000 60500 8.30 3.14
TWR060D100A N TXC061C5 Y N 2000 10.90 59500 61000 8.50 3.24
TWR060D100A N TXH054A4 Y N 1700 10.90 60000 60500 8.50 3.20

* START KIT REQUIRED


# FOR CAPACITIES 65,000 BTU AND ABOVE THE EFF. RATING IS EER, NOT SEER

Pub. No. 22-1624-05-0199 (EN) 27


Electrical
Data

SCHEMATIC DIAGRAMS
(SEE LEGEND)

TWR012-018C100A TWR024-036C100A
TWR042C100B

From Dwg. 21D151300 P01 From Dwg. 21D149100 P03

28 Pub. No. 22-1624-05-0199 (EN)


Electrical
Data

SCHEMATIC DIAGRAMS
(SEE LEGEND)

TWR048D100A TWR060D100A

From Dwg. 21D151744 P02 From Dwg. 21D151730 P02

Pub. No. 22-1624-05-0199 (EN) 29


Electrical
Data

SCHEMATIC DIAGRAMS

LEGEND

SYMBOL

30 Pub. No. 22-1624-05-0199 (EN)


Dimensions

TWR012-060 OUTLINE DRAWING


NOTE: ALL DIMENSIONS ARE IN MM (INCHES)

MODELS FIG. A B C D E
619 600 508
TWR012C 1 5/8 1/4
(24-3/8) (23-5/8) (20)
619 600 508
TWR018C 1 (24-3/8) (23-5/8) (20) 5/8 1/4

619 718 625


TWR024C 1 3/4 5/16
(24-3/8) (28-1/4) (24-5/8)
832 718 625
TWR030C 1 3/4 5/16
(32-3/4) (28-1/4) (24-5/8)
832 718 625
TWR036C 1 7/8 3/8
(32-3/4) (28-1/4) (24-5/8)
940 835 730
TWR042C 2 7/8 3/8
(37) (32-7/8) (28-3/4)
832 835 730
TWR048D 2 1-1/8 3/8
(32-3/4) (32-7/8) (28-3/4)
940 987 883
TWR060D 2 1-1/8 3/8
(37) (38-7/8) (34-3/4)
From Dwg. 21D147562 Rev. 6

Pub. No. 22-1624-05-0199 (EN) 31


Mechanical
Specification Options

General Condenser Coil


This unit is fully charged from the factory The outdoor coil provides low airflow
for up to 15 feet of piping. This unit is resistance and efficient heat transfer. The
designed to operate at outdoor ambient coil is protected on all four sides by
temperatures as high as 115°F. Cooling louvered panels and has a 5 year limited
capacities are matched with a wide warranty.
selection of air handlers and furnace Low Ambient Cooling
coils that are A.R.I. certified. The unit is As manufactured, this unit has a cooling
UL listed. Exterior is designed for capability to 55°F. The addition of an
outdoor application. evaporator defrost control permits
Casing operation to 40° F. The addition of an
Unit casing is constructed of heavy evaporator defrost control with TXV
gauge, galvanized steel and painted with permits low ambient cooling to 30° F.
a weather-resistant powder paint. Accessories
Refrigerant Controls Thermostats — Cooling only and heat/
Refrigeration system controls include cooling (manual and automatic
condenser fan and compressor changeover). Sub-base to match
contactor. High and low pressure controls thermostat and locking thermostat cover.
are inherent to the compressor. A factory Evaporator Defrost Control — See Low
installed liquid line drier is standard. Ambient Cooling.
Compressor
The Climatuff® compressor features a 5
year limited warranty, internal over
temperature and pressure protection,
total dipped hermetic motor windings,
and thermostatically controlled sump
heater. Other features include: roto lock
suction and discharge refrigerant
connections, centrifugal oil pump, and
low vibration and noise.

P.I.
The Trane Company
Unitary Products Group
6200 Troup Highway
Tyler, TX 75707
Since The Trane Company has a policy of continuous product improvement, it reserves the right to change
An American-Standard Company design and specifications without notice.

Вам также может понравиться