Вы находитесь на странице: 1из 29

FlexiPacket Series -

FlexiPacket Hub 800(FPH800) Introduction

MWT Shanghai

FlexiPacket Series Products in Tail/Chain/Hub Site

Any BTS 2G, 3G, iHSPA, LTE, WiMAX

Tail / Chain
FlexiPacket Radio

Hub

Aggregation/Core hiT7xxx

Service Core Applications

FlexiPacket FirstMile 200

FlexiPacket Hub 800

Cisco/Tellabs

FlexiPacket Hub 800H

2007 Nokia Siemens Networks. All rights reserved.

Cost-effective Modularity Solution for Complicated Access Domain


Diversity of Services/Interfaces supported by Modularity Architecture
2G/3G/LTE

TDM Microwave MLPPP Microwave STM-1/4 SDH Copper FPH800 Fiber Fiber Copper GE Packet

BSC

Zero Footprint IDU

ATM IMA FE

RNC

FirstMile 200

S-GW

GE

Two Option Card Slots


4xGE optical 4xGE electronics 16xE1/T1 Power Injector (2 P+E) 2xSTM-1/STM-4 2xFlexiBus 2xFPMR

FlexiPacket Hub 800 Main Board


1U Height 4 copper GE (2 P+E) 2 SFP option for GE or STM-1 16xE1/T1 with 75/100/120ohm 1 OOB (out of band)/1 DCN 1 Alarm 1 USB 1 1PPS&ToD 2xDC Input (-48V) Pluggable FAN tray

2007 Nokia Siemens Networks. All rights reserved.

Diversity of Option Cards adapt for Complicated Access Domain


Any Option Cards on Any Slots, No Limitation!
2x Power Injector 4xGE(e)
4x10/100/1000BASE

16xE1
Multi-service: TDM PW, ML-PPP

2xSTM-1/4
Flexible configure to STM-1 or STM-4

IF E1 GE SFP
4x10/100/1000BASE Compliant to ex-siemens BTS

Max. Quantity per FPH800 48 10 12 6 8 4 4 6

4xGE(e) 2xFB

GE RJ45

2xFPMR
Flexible configure to STM-1 or STM-4

4xGE(o)
4x100/1000BASE-X

STM-1 STM-4 FB P+E FPMR

2007 Nokia Siemens Networks. All rights reserved.

Multi-service Supported by FPH800 & Relative Panels


FPH800 with 16xRJ48C Panel CC4(1.0/2.3) Panel: 1/2U Height

16xRJ48C Panel: 1/2U Height

BNC Panel: 1U Height

TDM E1/T1 PWE Supported (CESOP/SAToP) CESoP/SAToP based on RFC5086/4553 Flexible configuration based on 64K level Flexible packet encapsulation from 1xE1/T1 to 32xE1/T1 Flexible configuration for PWE packet header Adaptive clock recovery (ACR) supported Data clock recovery (DCR) supported
5

Multilink PPP (ML-PPP) Max 16xE1 per ML-PPP Group 64Kbps based Support ML-PPP protection Support UDP/IP Head compression Support static IP routing Max 2 16xE1 MLPPP cards supported per chassis

ATM/IMA PWE Nice to have Feature on R2.5

2007 Nokia Siemens Networks. All rights reserved.

Right Product on MWT Hub Site by Supporting more FlexiPacket Radio


Features about FlexiPacket Radio
Max 4 P+E ports supported by one FPH800
Up to 2 P+E ports supported by main board Up to 1 power injector card supported

FlexiPacket Radio Interfaces on FPH800 2 P+E supported by Mainboard


Ethernet 1 Ethernet 2 P+E 3 P+E 4

Max 12 Eth ports can be connected to FlexiPacket Radio P+E ports can be connected to FlexiPacket Radio
directly Other ports can be connected with FlexiPacket Radio through external power injector. P+E 1 P+E 2

1 Power Injector card supported

MWR Link protection via CCM


1+1 Hot Standby (HSBY) MWR ring protection supported

FPH800 with Four FlexiPacket Radio

FM200

FPH800 with External Power Injector


FPR
External Power Injector

1+1 HSBY

FPR

P+E 1 P+E 2

FM200

MWR Ring
FPR FPR

FPH800

Ethernet 1 Ethernet 2

LAG GE

Packet
FM200

2007 Nokia Siemens Networks. All rights reserved.

Capable for existing SDH aggregation networks


Features of STM-1/4 Interface
Support
Interfaces on Main Board and 2xSTM-1/4 Card 2xSFP can be Configured to STM-1

2xSTM-1 interfaces on Main Board


Combo port with GE SFP
Max.

support two STM-1/4 cards Support MSP 1+1 Support EoS (Ethernet over SDH) Following is supported protocol for EoS:
GFP (Generic Framing Protocol) VCAT (Virtual Concatenation) LCAS (Link Capacity Adjustment Scheme) Up

Two 2xSTM-1/4 card can be supported FPH800 connected with existing SDH networks SDH
MSP 1+1

STM-1/4

to 63xE1 can be mapped on each STM-1/4 interface on 2xSTM1/4 card. Support VC4/VC12 crossconnection Support up to 8 VCG
7

FPR

E1

Eth

E1

Eth

2007 Nokia Siemens Networks. All rights reserved.

Compliant to Diversity of Legacy Interfaces


2xFlexiBus (FB) Card
Compliant FPH800 with ex-Nokia Base Station Up to two 2xFB cards supported

to ex-Nokia FB

interface
Max. two 2xFB card is supported No power feeding on 2xFB card Up

to 16xE1 encapsulated per each FB except the bandwidth for Ethernet 2xFlexiPacket MultiRadio (FPMR) Card
Compliant to Hybrid FPMR ODU. Max. two 2xFPMR card is supported Standardized GE RJ45 interface External power injector or Power injector card can provide power to ODU

FB

FPH800 connected with FPH800H 2xFPMR card Power Injector Card

FPH800 FPMR 1+1

Native E1 and Native Ethernet are included on FPMR interface Up to 75xE1 encapsulated per FPMR interface.
8

FPH800H/FPH220H

2007 Nokia Siemens Networks. All rights reserved.

CET E-Line/E-LAN Traffic Supported by FPH800


Point to Point(P2P) P2P EVC for E-Line Each service includes two ports Max 480 services Traffic from one port forward to another directly Multipoint to Multipoint(MP2MP) MP2MP EVC for E-LAN Each service includes multiple ports Max 480 services Each service has separate MAC address table, and MAC address learning Forward packet based on MAC address
9

E-Line Network Scenario

UNI CE

P2P EVC

UNI CE

CET Network

E-LAN Network Scenario


CE UNI

CET Network
UNI

Multi-point to multi-point EVC

CE

2007 Nokia Siemens Networks. All rights reserved.

Multiple QOS Mechanisms


Multi QoS Mechanisms Ingress rate limit per port Unknown unicast/multicast/broadcast storm control per port sRED dropping mechanism Queue schedule algorithms as below:
SP WRR WDRR

Egress shaping
Per port shaping Per queue shaping

FlexiPacket Hub800 QoS Model


Discard Ingress Discard Token Egress

Ingress rate limit Storm restraint

sRED

SP WRR WDRR

Egress shaping

Receive frame

Token bucket

Congestion detection/avoidance
10

In queue

Out queue

2007 Nokia Siemens Networks. All rights reserved.

Bandwidth Guarantee
Bandwidth Guarantee Support below SLA (Service Level Agreement) types UNI port
Service Certain classification rule in service

SLA parameters
CIR CBS PIR PBS

FlexiPacket Hub800 SLA Flow Process

Mark

Packet Classification Mark Shaping/drop

11

2007 Nokia Siemens Networks. All rights reserved.

Ethernet OAM Mechanism


2G/3G RNC/BSC

802.3ah

Ethernet service OAM: IEEE 802.1ag / ITU-T1731

802.3ah

Ethernet Service OAM

Connectivity Fault Management Performance Management


Connectivity check: Hardware based; Max 256 3.3ms/10ms flows supported

Loss Measurement
Delay Measurement

Loopback / Linktrace AIS/RDI APS: automatic protection switch


IEEE 802.1ag ITU-T Y.1731

Throughput Measurement

IEEE 802.1ag

Ethernet Link OAM

Ethernet Link in FirstMile


Discovery Remote Loopback

Remote failure indication

Threshold crossing alarms


IEEE 802.3ah

12

2007 Nokia Siemens Networks. All rights reserved.

Dual IDU Protection: Equipment Protection


Main Features of Dual IDU Protection
Dual IDU protection supported for connected interfaces with the following three solutions: Y-Cable: SFP/RJ45 GE can be protected Protection Panel: SFP/RJ45 GE, E1 can be protected Power Injector: RJ45 GE or 1+0 ODU can be protected
Y-Cable Cable solution for SFP/RJ45 GE Fiber Y-Cable RJ45 Y-Cable

Dual IDU Outlook

Dual IDU protection supported for connected interfaces with the right three solutions
1+0 ODU LPG LPG

Panel Solution for RJ45/SFP GE, E1

Local Interface

Box Solution for 1+0 ODU, RJ45 GE


13 2007 Nokia Siemens Networks. All rights reserved.

Dual IDU Protection: Protection Panel for local interfaces


Protection Panel: 8xGE RJ45+2xSFP RJ45+16xE1

Dual IDU with Protection Panel

LPG

Height: 1U

E1/SFP GE/RJ45 GE BTS/Node B

IDU#1 8xGE RJ45 Connectors

IDU#1 2xSFP

IDU#1 16xE1

1 2 34 1 23 4

5 6 7 8 1 2 34 56 7 8 5 6 7 8

1 1

2 2

1 2

IDU#2 8xGE RJ45 Connectors

User IDU#2 8xRJ45 2xSFP


14

IDU#2 16xE1

User 16xE1

User 8xRJ45

2007 Nokia Siemens Networks. All rights reserved.

Dual IDU Protection: Power Injector Panel for ODU connection


Power Injector Panel: 4xGE(P+E or no power)

Dual IDU with Power Injector

LPG

Height: 1/2U

1+0 ODU

RJ45 GE BTS/Node B

User 4xGE (ODU or local ports)

Alarm Port For Dual IDU

15

2007 Nokia Siemens Networks. All rights reserved.

Interface Protection on Single & Dual IDU


1+1 Hot-Standby Protection On Single IDU 1+1 Hot-Standby Protection On Different IDU

LAG Protection on Single IDU

LAG Protection on Different IDU

16

2007 Nokia Siemens Networks. All rights reserved.

Network Protection: <50ms Line Protection and Ring Protection


Linear Protection
Compliant to G.8031 1:1 linear APS protection Support revertive/non-revertive switch Up to 128 protection services supported <50ms traffic protection while CCM interval is 3.3ms Supported on both single IDU and Dual IDU

Linear Protection Network Scenario


RNC/BSC

Networ k

<50ms traffic protection

Ring Protection
Compliant to G.8032 Support revertive/non-revertive switch <50ms traffic protection while CCM interval is 3.3ms Supported on both single IDU and Dual IDU

Ring Protection Network Scenario

RNC/BSC

Netw ork

2G/3G

<50ms traffic protection

17

2007 Nokia Siemens Networks. All rights reserved.

Spanning Tree Protocol: RSTP/MSTP


RSTP/MSTP Features Supported Comply with 802.1W, compliant with STP/RSTP It can be used if CFM is not supported Switching time within one second level

RSTP/MSTP Protection Network Scenario

2G/3G

RNC/BSC

18

2007 Nokia Siemens Networks. All rights reserved.

Diversity of Synchronization Technologies Supported


Features of Sync Ethernet
Compatible with G.8261/G.8262 Support SSM technology Compatible with legacy equipment
not supporting SSM Support regenerator of recovery clock by Sync E

Sync Ethernet Network Scenario


2M

1G 10G

RNC

E1/T1
Each E1/T1 ports can
be configured as sync clock input or output

Features of IEEE1588
Support IEEE1588 v2 Mode supported
Slave clock mode Boundary clock
mode

IEEE1588 Network Scenario


2M RNC site node

Packet
RNC

1PPS&ToD

Provide both the frequency sync and time sync to base station

Support BMC

Timing packets (unicast) 1588 2MHz Flexi WCDMA master /2Mbps GPS
BTS

These technologies are not exclusive and can be used flexibility according to real network
19 2007 Nokia Siemens Networks. All rights reserved.

All-Outdoor Case Solution with FlexiOutdoor Case


Features of FlexiOutdoor Case Suitable for IDU installed on nonweather protected environment. FOC contains four fans for hot radiate. FOC contains heating elements for preheater. Temperature range can be extended to (-40C, +55C) in FOC from (-5C, +50C) Support two FPH800 in FOC. Two FPH800 Capable per FOC

Minimum Space with FOC


Outlook of FlexiOutdoor Case

20

2007 Nokia Siemens Networks. All rights reserved.

USB Key makes equipment replacement conveniently


Features of USB Key
Small size, convenient to carry. The load/configuration of IDU and ODU can be backup onto the USB key by NMS or WebLCT manually The load/configuration of IDU and ODU can be easily updated to the new replacement when one of them failed. USB key is not mandatory and the equipment can work normally without USB key.

Convenient and Quick Maintenance with USB Key


1
Fault

Pull USB Key out

3
Plug in USB Key
OK!

Old system configuration is copied to new equipment by USB Key, So the equipment can be restored very quickly!

21

2007 Nokia Siemens Networks. All rights reserved.

Convenient Web LCT for easy Installation & Troubleshooting


Features of Web LCT
Navigation function, convenient to configure Alarm and event monitor and report Support software upgrade Remote ODU management No software install needed Automatically synchronize with NE

Outlook of FlexiPacket Hub 800 Web LCT

Navigation Function

Web LCT Environment

Internet

22

2007 Nokia Siemens Networks. All rights reserved.

Commission Tool makes firstly Equipment Installation easier


Features of Commission Tool
Easy equipment installation Friendly user interface, easy to operate No need frequently configure the IP addr. of serial port and NM port during installation Support navigation function

Outlook of FPH800 Commission Tool

FPH800 Commission Tool Use Environment


ODU main ODU main

ODU Stand-By ODU Stand-By

23

2007 Nokia Siemens Networks. All rights reserved.

NetAct/NetViewer Transport Network Management


NetAct / NetViewer Feature Highlight
NetViewer manages MWR network: ODU + IDU Path management/planning E2E service provisioning Fault management/performance management NetAct manages whole transport network Access Aggregation Core

MBH E2E Management

NetAct Transport

NAT Connectivity

Ax200 FPH800

FM200 FPR

Cisco 7600 A-2200 A-4100 Juniper A-8100 MX/BX/EX

MWR2941 Access layer

Juniper M-/T-Series Cisco 7600

NAT/NV Transport Release Plan

Aggregation layer

Core layer

2010
Hub800
R2.0 4/11

2011
R2.5 10/11

Commissioning Tool
NV NAT
R10.1 Q1/10

R1.0 Q2/10

R1.1 7/10

R1.2 9/10

R1.3 Q1/11

R1.4 Q2/11

R10.1 EP1 PT 7/10

R10.1 EP1 12/10

R10.2 PT 2/11

R10.2 4/11
R6.0 EP3 4/11 R7.0 7/11

R10.3 Q3/11

10.4 Q4/11 R7.0 EP2 Q4/11

R6.0 EP1 R6.0 EP2 1/11 1/11

24

2007 Nokia Siemens Networks. All rights reserved.

FlexiPacket Hub800 Program Roadmap


2010
Low cost tail/chain site
FlexiPacket FirstMile 200

2011
Complete MW Access

2012

Hub configurations Optimized MW config.


R2.0 R2.5 R2.5

R1.0

R3.0 R3.0

R3.5 R3.5

L2
FlexiPacket Hub 800

R2.0

FirstMile 200 and FPH 800

FlexiPacketHub 800

FlexiPacketHub 800

E-LINE and E-LAN Services Advanced QoS (policing,WRED,shaping) L2 security UNI port shutdown on service failure RSTP/MSTP (*) Eth OAM: CFM and PM (Y.1731,802.1ag) Security pack: SNMPv3, SSH, SFTP SATOP
(*) early availability under study

FlexiPacket Radio support MainBoard: 16xE1 CES, 4xGbE, 2xGbE/STM1 Line Cards: 16xE1 / 4xGbE / 2xPower Injector / 2xFlexBus Synch Eth 1588 slave CESOP WebLCT
FirstMile 200
Nodal Nx (1+0)+Mx(1+1) Power to ODU (up to 4)

1+1 IDU protection

Line card: STM-1/4 PIU w/ EoS ML-PPP ATM IMA* 1+1 IDU protection IEEE1588 boundary clock Eth OAM enhancement IEEE802.1ag FM Y.1731 PM Protection G.8031 G.8032
MLPPP EoS 1588TC/BC

Advanced L2 Eth 2.0 1.0 Tail / chain Access Hub 1stAggr 2Aggr Controller

L2 Eth (Provider Bridge)

Services: E-Line/ELAN SynchE, 1588 Slave OAM Netw Protection TDMPWE

Major release, Pilot available (CP) Available Contract Planned Study Item
25

Minor release , Pilot available (CP)


2007 Nokia Siemens Networks. All rights reserved.

Application in Hybrid mode

Product description

FlexiPacket Hub 800H Main Feature



Switch SW/FM to full packet mode. E1 over STM1 Ring Protection (SNCP, xSTP) 1+1 HSB 4ODU (Flexi Packet MultiRadio 2.51) support ACM supported

Two card slots can support



16xE1/T1 interface card 4xGE interface card Power injector 2xFlexBus card (future) STM-1/4 interface card (future)

Product Positioning and Customer Usecase


Ring topology, India market mainly
BTS E1

NB NB
BTS E1 Eth

Eth

Ring Node

SDH CET Aggregation/backbone

BTS E1

NB

Eth

Ring Site 2G+3G BTS Nb


E1 Eth

Ring Node Site


Nb
E1 Eth

E1

Eth STM-1

FlexiPacketHub 220H

FPH 220H ring sites,


FPH 800H in Node (STM-1+GE)

Product Positioning and Customer Usecase (2)


BTS E1

NB

NB

BTS E1

Eth

Eth

MWR hub
BTS E1

MWR hub

SDH CET Aggregation/backbone

NB

Eth

Tail Site 2G+3G


BTS

Nb
E1 E1 Eth

Chain Site 2G+3G BTS Nb


E1 E1 Eth

Hub Site Nb
E1 Eth

Edge Site

Eth STM-1

FlexiPacketHub 220H FlexiPacketHub 220H

FPH 220H in tail and chain sites 16xE1+GE interfaces

FPH 800H Hub: nodal site Edge: STM-1+GE