AS per clause 2.1.4,; 8.

1 of SP 43 (S & T) : 1987 HANDBOOK ON STRUCTURES WITH i REINFORCED CONCRETE PORTAL FRAMES (WITHOUT CRANES) It has been found that because of the low rise of the buildings considered, forces in the members, even due to the lowest basic wind pressure of 1.0 kN/m were more than those due to the most severe earthquake zone forces. & Seismic load is generally not of significance for low rise buildings It is further stared that earthquake forces do not govern the design as per clause 2.2 of SP-47(S&T) 1988 & clause no 2.1 of SP 38(S&T) 1987. However, Seismic Strengthening Arrangements of masonry buildings could have been adopted as per Clause no 8.4.1. All masonry buildings shall be strengthened by the methods, as specified for various building categories (A to D ) for maximum four storyes as per IS 4326 : 1993 (Reaffirmed 1998) Edition 3.2 (2002-04) EARTHQUAKE RESISTANT DESIGN AND CONSTRUCTION OF BUILDINGS CODE OF PRACTICE. In view of the above facts there is no need to do analysis for earthquake forces being low rise framed building. The load combinations as per IS codes have been considers in design analysis. In case any modification/ correction is required, the same may be incorporates in the drawing.