OVERSEAS TECHNICAL ENGINEERING AND CONSTRUCTION PTE LTD. DOC. NO. : DESIGN SHEET SHEET NO.

BQ1114 I BILL OF QUANTITY LOCATION : Tank Pit (Foundations) GRADE- C 35 (SCRUBBER FOUNDATION)

1) SUBSTRUCTURE 1.1) CONCRETE

LENGTH OF FOUNDATION WIDTH OF FOUNDATION HEIGHT OF FOUNDATION NOS. OF FOUNDATION REQUIRED CONC. VOLUME REQUIRED LEAN CONC. REQUIRED 1.2) REINFORCEMENT A) LONGITUDINAL BENDING REINFORCEMENT REBAR LENGTH QTY. REBAR SIZE REBAR SPACING UNIT WEIGHT OF REBAR WEIGHT OF REBAR B) TRANSVERSE BENDING REINFORCEMENT REBAR LENGTH QTY. REBAR SIZE REBAR SPACING UNIT WEIGHT OF REBAR WEIGHT OF REBAR D) TOTAL REBAR WEIGHT REQUIRED 2) EXCAVATION WORK ESTIMATED EXCAVATION DEPTH ESTIMATED EXCAVATION VOLUME 3) FORMWORKS AREA REQUIRED

= = = = = =

1.10 0.60 0.50 1.00 0.33 0.03

m m m nos. 3 m m3 fy = 460 N/mm


2

= = = T 13 = = =

1.60 m 8 nos. Bar 200 mm 1.042 kg/m 0.01 Tons.

= = = T 13 = = = =

1.10 m 13 nos. Bar 200 mm 1.042 kg/m 0.01 Tons. 0.03 Tons.

= =

0.25 m 3 0.21 m

2 1.7 m

II

BQ SUMMARY TOTAL NOS. OF PUMP SUBSTRUCTURE TOTAL CONC. VOLUME REQUIRED TOTAL LEAN CONC. REQUIRED TOTAL REBAR WEIGHT TOTAL ESTIMATED EXCAVATION VOLUME TOTAL FORMWORKS AREA REQUIRED = = = = = = 1 nos. 0.33 0.03 0.03 0.21 1.70 m3 m3 Tons. m3 m2

Note: 1) Foundation Type shall be consider as spread footing type.