Attenuation and Average Power Ratings
Description

Type No.

Cable Ordering Information


Standard and Fire Retardant Cables
5/8" Standard Cable, Standard Jacket
5/8" Fire Retardant Jacket (CATVR)
Low VSWR and Specialized Cables
5/8" Low VSWR, specify operating band
Cable for Cellular, standard jacket
824-960 MHz, 1.20 VSWR, max.
880-960 MHz, 1.10 VSWR, max.

HJ4.5-50
HJ4.5RN-50
HJ4.5P-50-(**)
HJ4.5P-50-1
HJ4.5P-50-2

** Insert suffix number from Low VSWR Specifications table.

Characteristics
Electrical
Impedance, ohms
Maximum Frequency, GHz
Velocity, percent
Peak Power Rating, kW
dc Resistance, ohms/1000 ft (1000 m)
Inner
Outer
dc Breakdown, volts
Jacket Spark, volts RMS
Capacitance, pF/ft (m)
Inductance, H/ft (m)
Mechanical
Outer Conductor
Inner Conductor
Diameter over Jacket, in (mm)
Diameter over Copper Outer Conductor, in (mm)
Diameter Inner Conductor, in (mm)
Nominal Inside Transverse Dimensions (cm)
Minimum Bending Radius, in (mm)
Number of Bends, minimum (typical)
Bending Moment, lb-ft (Nm)
Cable Weight, lb/ft (kg/m)
Tensile Strength, lb (kg)
Flat Plate Crush Strength, lb/in (kg/mm)

552

50 1
6.6
92
40
0.41 (1.35)
0.23 (0.75)
4000
5500
22.3 (73.2)
0.056 (0.182)
Copper
Copper
0.875 (22.2)
0.775 (19.7)
0.272 (6.9)
1.51
7 (180)
15 (20)
16 (21.7)
0.40 (0.59)
750 (340)
250 (4.5)

Frequency
MHz

Attenuation
dB/100 ft

Attenuation
dB/100 m

Average
Power, kW

0.5
1
1.5
2
10
20
30
50
88
100
108
150
200
300
400
450
500
600
700
800
824
894
960
1000
1250
1500
2000
3000
4000*
5000
6000
6600

0.034
0.048
0.058
0.067
0.152
0.215
0.264
0.343
0.457
0.488
0.508
0.602
0.699
0.863
1.00
1.07
1.13
1.24
1.35
1.45
1.47
1.54
1.60
1.64
1.85
2.04
2.40
3.01
3.55
4.04
4.49
4.75

0.110
0.156
0.192
0.221
0.497
0.706
0.867
1.12
1.50
1.60
1.67
1.98
2.29
2.83
3.29
3.51
3.71
4.09
4.43
4.76
4.85
5.05
5.25
5.37
6.07
6.70
7.86
9.89
11.6
13.3
14.8
15.6

40.0
40.0
40.0
35.30
15.64
10.98
8.94
6.90
5.17
4.84
4.65
3.92
3.38
2.73
2.35
2.20
2.09
1.89
1.74
1.62
1.59
1.52
1.47
1.43
1.27
1.16
0.986
0.784
0.665
0.585
0.525
0.496

Standard Conditions:
For Attenuation. VSWR 1.0 ambient temperature 20C (68F),
atmospheric pressure, dry air.
For Average Power. VSWR 1.0, inner temperature 100C (212F), ambient
temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
* Operation of this cable in the 4250-4400 MHz band is not recommended
because of VSWR spikes produced by the dielectric spacing.

Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479

Вам также может понравиться