Вы находитесь на странице: 1из 3

M

O
D
.
E
L
E
.
L
T
G
.
0
0
4
/
4
S
h
.
1
/
3
DATA SHHET FOR FLOODLIGHTING MASTS
ELECTRICAL
FEEDER
DEVICE
MOUVEMENT
Dumper device :
Fixed
RACK
FLOODLIGHTS
QUANTITY N. CODE REFERENCE DOCUMENT
DESIGN DATA
PREP'D CHK'D APPR'D DATE DESCRIPTION REV.
0
MAST Manual Hydraulic
Electric
Manual
Portable Semiportable Fix
Reference :
FLOODLIGHTS
Protection degree : IP
Cable feeder : mm - Type:
-
Cable feeder to floodlight : mm
DISTRIBUTION
HOUSING BOX
FOR FLOODLIGHTS
FEEDER
BOARD WITH
FLOODLIGHTS
ELECTRICAL UNIT
IP
mm
-
QUANTITY N.
mm
SURFACE
PROTECTION
Galvanizing Undercoat antioxidizer cycle
Voltage : V - Frequency : Hz
mm - Type:
Wiring diagram : Fig. P Fig. Q -
Inside the mast in locked housing slot
In suitable feeder board outside the mast
IP Safety execution
Hubs : With cable glands Threaded only
Threaded type :
CIRCUIT
NOTES:
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
- Type:
- Type:
- Type:
Protection degree :
Cable feeder :
Cable feeder to floodlight :
Cable feeder :
Protection degree :
































































M
O
D
.
E
L
E
.
L
T
G
.
0
0
4
/
4
S
h
.
2
/
3
DATA SHEET FOR FLOODLIGHTING MASTS
This document is Company property. The Company lawfully reserves all rights.
Dept.
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
DESIGN DATA
NOTES:
CODE OR REFERENCE OF THE MAST ORIENTATION OF THE MAST
FLOODLIGHT FLOODLIGHT ORIENTATION
POS.
CODE
OR
REFERENCE
HORIZONTAL VERTICAL
'a' 'b' 'c'
rad. rad. rad.
ORIENTATION OF THE FLOODLIGHTS
1,59 rad
(90)
3,18 rad
(180)
4,77 rad
(270)
0
'a'
HORIZONTAL
ROUNDED
RACK
1,59 rad
(90)
3,18 rad
(180)
4,77 rad
(270)
0
'b'
HORIZONTAL
ON FIX PLATFORM
OR CROSS-RACK
1,59 rad
(90)
4,77 rad
(270)
0
'c'
VERTICAL
ON MOUVABLE



















































































M
O
D
.
E
L
E
.
L
T
G
.
0
0
4
/
4
S
h
.
1
/
3
DATA SHHET FOR FLOODLIGHTING MASTS
This document is Company property. The Company lawfully reserves all rights.
Dept.
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job.
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
AT THE MAST
FEEDER
CONSTRUCTION DATA
MAST
RACK
DISTRIBUTION
HOUSING BOX FOR
FLOODLIGHTS
BOARD WITH
ELECTRICAL UNITS
FEEDER
BOARD
BASE
NOTES:
Costruction data :
Out-foundation height : H = mm
Foundation dimension : h = mm
Mouvable rounded-rack diameter : Z = mm
Material :
FLOODLIGHTS
Base diameter : D = mm
MANUFACTURER
REFERENCE
Anchoring plate dimensions : R x S, o =
Platform dimensions : mm
Dimensions (height x width x depth) : mm
Hubs and cable glands quantity : N =
Cable gland costruction type :
Cable glands materials :
Terminal block construction type :
mm
N =
Electrical units quantity : N =
mm
Threaded hubs quantity : N =
TOTAL MASS : Kg
TOTAL SURFACE EXPOSED TO WIND : m
FLOODLIGHTS
FEEDER
Costruction data :
L x W x Y =
Material :
Dimensions (height x width x depth) :
Costruction data :
Hubs and cable glands quantity :
Cable gland costruction type :
Cable glands materials :
Dimensions (height x width x depth) :
Costruction data :
Cable gland costruction type :
Cable glands materials :